251 resultados para concept questions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aims of the study were to evaluate the prevalence of acute coronary syndrome (ACS) among patients presenting with atypical chest pain who are evaluated for acute aortic syndrome (AAS) or pulmonary embolism (PE) with computed tomoangiography (CTA) and discuss the rationale for the use of triple rule-out (TRO) protocol for triaging these patients. METHODS: This study is a retrospective analysis of patients presenting with atypical chest pain and evaluated with thoracic (CTA), for suspicion of AAS/PE. Two physicians reviewed patient files for demographic characteristics, initial CT and final clinical diagnosis. Patients were classified according to CTA finding into AAS, PE and other diagnoses and according to final clinical diagnosis into AAS, PE, ACS and other diagnoses. RESULTS: Four hundred and sixty-seven patients were evaluated: 396 (84.8%) patients for clinical suspicion of PE and 71 (15.2%) patients for suspicion of AAS. The prevalence of ACS and AAS was low among the PE patients: 5.5% and 0.5% respectively (P = 0.0001), while the prevalence of ACS and PE was 18.3% and 5.6% among AAS patients (P = 0.14 and P = 0.34 respectively). CONCLUSION: The prevalence of ACS and AAS among patients suspected clinically of having PE is limited while the prevalence of ACS and PE among patients suspected clinically of having AAS is significant. Accordingly patients suspected for PE could be evaluated with dedicated PE CTA while those suspected for AAS should still be triaged using TRO protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans un contexte en constante évolution, l'élaboration, la mise en oeuvre et l'évaluation des politiques publiques de biodiversité nécessitent d'anticiper les changements futurs possibles afin de pouvoir se préparer à temps. Or les informations concernant ces changements sont nombreuses et les enjeux qui pourraient s'avérer importants à l'avenir sont souvent peu visibles. Pour répondre à ce défi, une expertise multi-acteurs et multidisciplinaire s'inspirant des démarches d'horizon scanning et intitulée BioPIQue 2013 a permis d'identifier 25 questions émergentes, dont 10 questions stratégiques, pour les politiques publiques de biodiversité en France métropolitaine d'ici à 2020. Ces questions émergentes sont autant d'opportunités et de risques que l'ensemble es acteurs qui souhaitent avancer vers une plus grande prise en compte des enjeux de biodiversité peuvent saisir.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bandura (1986) developed the concept of moral disengagement to explain how individuals can engage in detrimental behavior while experiencing low levels of negative feelings such as guilt-feelings. Most of the research conducted on moral disengagement investigated this concept as a global concept (e.g., Bandura, Barbaranelli, Caprara, & Pastorelli, 1996; Moore, Detert, Klebe Treviño, Baker, & Mayer, 2012) while Bandura (1986, 1990) initially developed eight distinct mechanisms of moral disengagement grouped into four categories representing the various means through which moral disengagement can operate. In our work, we propose to develop measures of this concept based on its categories, namely rightness of actions, rejection of personal responsibility, distortion of negative consequences, and negative perception of the victims, and which is not specific a particular area of research. Through our measures, we aim at better understanding the cognitive process leading individuals to behave unethically by investigating which category plays a role in explaining unethical behavior depending on the situations in which individuals are. To this purpose, we conducted five studies to develop the measures and to test its predictive validity. Particularly, we assessed the ability of the newly developed measures to predict two types of unethical behaviors, i.e. discriminatory behavior and cheating behavior. Confirmatory Factor analyses demonstrated a good fit of the model and findings generally supported our predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Low-dose, Visudyne®-mediated photodynamic therapy (photo-induction) was shown to selectively enhance tumor vessel transport causing increased uptake of systemically administered chemotherapy in various tumor types grown on rodent lungs. The present experiments explore the efficacy of photo-induced vessel modulation combined to intravenous (IV) liposomal cisplatin (Lipoplatin®) on rodent lung tumors and the feasibility/toxicity of this approach in porcine chest cavities. MATERIAL AND METHODS: Three groups of Fischer rats underwent orthotopic sarcoma (n = 14), mesothelioma (n = 14), or adenocarcinoma (n = 12) implantation on the left lung. Half of the animals of each group had photo-induction (0.0625 mg/kg Visudyne®, 10 J/cm(2) ) followed by IV administration of Lipoplatin® (5 mg/kg) and the other half received Lipoplatin® without photo-induction. Then, two groups of minipigs underwent intrapleural thoracoscopic (VATS) photo-induction (0.0625 mg/kg Visudyne®; 30 J/cm(2) hilum; 10 J/cm(2) apex/diaphragm) with in situ light dosimetry in combination with IV Lipoplatin® administration (5 mg/kg). Protocol I (n = 6) received Lipoplatin® immediately after light delivery and Protocol II (n = 9) 90 minutes before light delivery. Three additional animals received Lipoplatin® and VATS pleural biopsies but no photo-induction (controls). Lipoplatin® concentrations were analyzed in blood and tissues before and at regular intervals after photo-induction using inductively coupled plasma mass spectrometry. RESULTS: Photo-induction selectively increased Lipoplatin® uptake in all orthotopic tumors. It significantly increased the ratio of tumor to lung Lipoplatin® concentration in sarcoma (P = 0.0008) and adenocarcinoma (P = 0.01) but not in mesothelioma, compared to IV drug application alone. In minipigs, intrapleural photo-induction combined to systemic Lipoplatin® was well tolerated with no toxicity at 7 days for both treatment protocols. The pleural Lipoplatin® concentrations were not significantly different at 10 and 30 J/cm(2) locations but they were significantly higher in protocol I compared to II (2.37 ± 0.7 vs. 1.37 ± 0.7 ng/mg, P  < 0.001). CONCLUSION: Visudyne®-mediated photo-induction selectively enhances the uptake of IV administered Lipoplatin® in rodent lung tumors. Intrapleural VATS photo-induction with identical treatment conditions combined to IV Lipoplatin chemotherapy is feasible and well tolerated in a porcine model. Lasers Surg. Med. 47:807-816, 2015. © 2015 Wiley Periodicals, Inc.