318 resultados para Slope Mass Rating
Resumo:
OBJECTIVES: The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. DESIGN AND METHODS: Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. RESULTS: Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma.
Resumo:
Mass spectrometry (MS) is currently the most sensitive and selective analytical technique for routine peptide and protein structure analysis. Top-down proteomics is based on tandem mass spectrometry (MS/ MS) of intact proteins, where multiply charged precursor ions are fragmented in the gas phase, typically by electron transfer or electron capture dissociation, to yield sequence-specific fragment ions. This approach is primarily used for the study of protein isoforms, including localization of post-translational modifications and identification of splice variants. Bottom-up proteomics is utilized for routine high-throughput protein identification and quantitation from complex biological samples. The proteins are first enzymatically digested into small (usually less than ca. 3 kDa) peptides, these are identified by MS or MS/MS, usually employing collisional activation techniques. To overcome the limitations of these approaches while combining their benefits, middle-down proteomics has recently emerged. Here, the proteins are digested into long (3-15 kDa) peptides via restricted proteolysis followed by the MS/MS analysis of the obtained digest. With advancements of high-resolution MS and allied techniques, routine implementation of the middle-down approach has been made possible. Herein, we present the liquid chromatography (LC)-MS/MS-based experimental design of our middle-down proteomic workflow coupled with post-LC supercharging.
Resumo:
Candidate gene and genome-wide association studies have not identified common variants, which are reliably associated with depression. The recent identification of obesity predisposing genes that are highly expressed in the brain raises the possibility of their genetic contribution to depression. As variation in the intron 1 of the fat mass- and obesity-associated (FTO) gene contributes to polygenic obesity, we assessed the possibility that FTO gene may contribute to depression in a cross-sectional multi-ethnic sample of 6561 depression cases and 21 932 controls selected from the EpiDREAM, INTERHEART, DeCC (depression case-control study) and Cohorte Lausannoise (CoLaus) studies. Major depression was defined according to DSM IV diagnostic criteria. Association analyses were performed under the additive genetic model. A meta-analysis of the four studies showed a significant inverse association between the obesity risk FTO rs9939609 A variant and depression (odds ratio=0.92 (0.89, 0.97), P=3 × 10(-4)) adjusted for age, sex, ethnicity/population structure and body-mass index (BMI) with no significant between-study heterogeneity (I(2)=0%, P=0.63). The FTO rs9939609 A variant was also associated with increased BMI in the four studies (β 0.30 (0.08, 0.51), P=0.0064) adjusted for age, sex and ethnicity/population structure. In conclusion, we provide the first evidence that the FTO rs9939609 A variant may be associated with a lower risk of depression independently of its effect on BMI. This study highlights the potential importance of obesity predisposing genes on depression.
Resumo:
Recent studies show that the composition of fingerprint residue varies significantly from the same donor as well as between donors. This variability is a major drawback in latent print dating issues. This study aimed, therefore, at the definition of a parameter that is less variable from print to print, using a ratio of peak area of a target compound degrading over time divided by the summed area of peaks of more stable compounds also found in latent print residues.Gas chromatography-mass spectrometry (GC/MS) analysis of the initial lipid composition of latent prints identifies four main classes of compounds that can be used in the definition of an aging parameter: fatty acids, sterols, sterol precursors, and wax esters (WEs). Although the entities composing the first three groups are quite well known, those composing WEs are poorly reported. Therefore, the first step of the present work was to identify WE compounds present in latent print residues deposited by different donors. Of 29 WEs recorded in the chromatograms, seven were observed in the majority of samples.The identified WE compounds were subsequently used in the definition of ratios in combination with squalene and cholesterol to reduce the variability of the initial composition between latent print residues from different persons and more particularly from the same person. Finally, the influence of a latent print enhancement process on the initial composition was studied by analyzing traces after treatment with magnetic powder, 1,2-indanedione, and cyanoacrylate.
Resumo:
Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).
Resumo:
Background: The ratio of the rates of non-synonymous and synonymous substitution (d(N)/d(S)) is commonly used to estimate selection in coding sequences. It is often suggested that, all else being equal, d(N)/d(S) should be lower in populations with large effective size (Ne) due to increased efficacy of purifying selection. As N-e is difficult to measure directly, life history traits such as body mass, which is typically negatively associated with population size, have commonly been used as proxies in empirical tests of this hypothesis. However, evidence of whether the expected positive correlation between body mass and d(N)/d(S) is consistently observed is conflicting. Results: Employing whole genome sequence data from 48 avian species, we assess the relationship between rates of molecular evolution and life history in birds. We find a negative correlation between dN/dS and body mass, contrary to nearly neutral expectation. This raises the question whether the correlation might be a method artefact. We therefore in turn consider non-stationary base composition, divergence time and saturation as possible explanations, but find no clear patterns. However, in striking contrast to d(N)/d(S), the ratio of radical to conservative amino acid substitutions (K-r/K-c) correlates positively with body mass. Conclusions: Our results in principle accord with the notion that non-synonymous substitutions causing radical amino acid changes are more efficiently removed by selection in large populations, consistent with nearly neutral theory. These findings have implications for the use of d(N)/d(S) and suggest that caution is warranted when drawing conclusions about lineage-specific modes of protein evolution using this metric.
Resumo:
Conventional methods are sometimes insufficient to identify human bacterial pathogens, and alternative techniques, often molecular, are required. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identified with a valid score 45.9% of 410 clinical isolates from 207 different difficult-to-identify species having required 16S rRNA gene sequencing. MALDI-TOF MS might represent an alternative to 16S rRNA gene sequencing.
Resumo:
The use of herbicides in agriculture may lead to environmental problems, such as surface water pollution, with a potential risk for aquatic organisms. The herbicide glyphosate is the most used active ingredient in the world and in Switzerland. In the Lavaux vineyards it is nearly the only molecule applied. This work aimed at studying its fate in soils and its transfer to surface waters, using a multi-scale approach: from molecular (10-9 m) and microscopic scales (10-6 m), to macroscopic (m) and landscape ones (103 m). First of all, an analytical method was developed for the trace level quantification of this widely used herbicide and its main by-product, aminomethylphosphonic acid (AMPA). Due to their polar nature, their derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was done prior to their concentration and purification by solid phase extraction. They were then analyzed by ultra performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS). The method was tested in different aqueous matrices with spiking tests and validated for the matrix effect correction in relevant environmental samples. Calibration curves established between 10 and 1000ng/l showed r2 values above 0.989, mean recoveries varied between 86 and 133% and limits of detection and quantification of the method were as low as 5 and 10ng/l respectively. At the parcel scale, two parcels of the Lavaux vineyard area, located near the Lutrive River at 6km to the east of Lausanne, were monitored to assess to which extent glyphosate and AMPA were retained in the soil or exported to surface waters. They were equipped at their bottom with porous ceramic cups and runoff collectors, which allowed retrieving water samples for the growing seasons 2010 and 2011. Results revealed that the mobility of glyphosate and AMPA in the unsaturated zone was likely driven by the precipitation regime and the soil characteristics, such as slope, porosity structure and layer permeability discrepancy. Elevated glyphosate and AMPA concentrations were measured at 60 and 80 cm depth at parcel bottoms, suggesting their infiltration in the upper parts of the parcels and the presence of preferential flow in the studied parcels. Indeed, the succession of rainy days induced the gradual saturation of the soil porosity, leading to rapid infiltration through macropores, as well as surface runoff formation. Furthermore, the presence of more impervious weathered marls at 100 cm depth induced throughflows, the importance of which for the lateral transport of the herbicide molecules was determined by the slope steepness. Important rainfall events (>10 mm/day) were clearly exporting molecules from the soil top layer, as indicated by important concentrations in runoff samples. A mass balance showed that total loss (10-20%) mainly occurred through surface runoff (96%) and, to a minor extent, by throughflows in soils (4%), with subsequent exfiltration to surface waters. Observations made in the Lutrive River revealed interesting details of glyphosate and AMPA dynamics in urbanized landscapes, such as the Lavaux vineyards. Indeed, besides their physical and chemical properties, herbicide dynamics at the catchment level strongly depend on application rates, precipitation regime, land use and also on the presence of drains or constructed channels. Elevated concentrations, up to 4970 ng/l, observed just after the application, confirmed the diffuse export of these compounds from the vineyard area by surface runoff during main rain events. From April to September 2011, a total load of 7.1 kg was calculated, with 85% coming from vineyards and minor urban sources and 15% from arable crops. Small vineyard surfaces could generate high concentrations of herbicides and contribute considerably to the total load calculated at the outlet, due to their steep slopes (~10%). The extrapolated total amount transferred yearly from the Lavaux vineyards to the Lake of Geneva was of 190kg. At the molecular scale, the possible involvement of dissolved organic matter (DOM) in glyphosate and copper transport was studied using UV/Vis fluorescence spectroscopy. Combined with parallel factor (PARAFAC) analysis, this technique allowed characterizing DOM of soil and surface water samples from the studied vineyard area. Glyphosate concentrations were linked to the fulvic-like spectroscopic signature of DOM in soil water samples, as well as to copper, suggesting the formation of ternary complexes. In surface water samples, its concentrations were also correlated to copper ones, but not in a significant way to the fulvic-like signature. Quenching experiments with standards confirmed field tendencies in the laboratory, with a stronger decrease in fluorescence intensity for fulvic-like fluorophore than for more aromatic ones. Lastly, based on maximum concentrations measured in the river, an environmental risk for these compounds was assessed, using laboratory tests and ecotoxicity data from the literature. In our case and with the methodology applied, the risk towards aquatic species was found negligible (RF<1).
Resumo:
Components of daily energy expenditure were measured serially by whole-body calorimetry in Gambian women before pregnancy and at 6, 12, 18, 24, 30, and 36 wk gestation. Weight gain was (mean +/- SD) 6.8 +/- 2.8 kg, fat deposition was 2.0 +/- 2.5 kg and lean tissue deposition was 5.0 +/- 2.5 kg. Basal metabolic rate (BMR) was depressed during the first 18 wk of gestation, causing total cumulative maintenance costs by week 36 to be 8.4 MJ. Individual responses to pregnancy correlated with changes in body mass (36 wk: delta BMR vs delta weight; r = 0.60, P < 0.01 delta BMR vs delta LBM; r = 0.62, P < 0.01). There was no significant increase in the cost of treadmill exercise (0% slope: F = 0.71, P = 0.64; 5% slope: F = 1.97, P = 0.10), 24-h energy expenditure (F = 0.72, P = 0.64), activity or diet-induced thermogenesis (F = 1.02, P = 0.43), during pregnancy in spite of body weight gain. Total metabolic costs over 36 wk were 144 MJ (fetus 43 MJ, fat deposition 92 MJ, cumulative maintenance costs 8.4 MJ). These were far lower than reported for well-nourished Western populations.
Resumo:
Following the success of the first round table in 2001, the Swiss Proteomic Society has organized two additional specific events during its last two meetings: a proteomic application exercise in 2002 and a round table in 2003. Such events have as their main objective to bring together, around a challenging topic in mass spectrometry, two groups of specialists, those who develop and commercialize mass spectrometry equipment and software, and expert MS users for peptidomics and proteomics studies. The first round table (Geneva, 2001) entitled "Challenges in Mass Spectrometry" was supported by brief oral presentations that stressed critical questions in the field of MS development or applications (Stöcklin and Binz, Proteomics 2002, 2, 825-827). Topics such as (i) direct analysis of complex biological samples, (ii) status and perspectives for MS investigations of noncovalent peptide-ligant interactions; (iii) is it more appropriate to have complementary instruments rather than a universal equipment, (iv) standardization and improvement of the MS signals for protein identification, (v) what would be the new generation of equipment and finally (vi) how to keep hardware and software adapted to MS up-to-date and accessible to all. For the SPS'02 meeting (Lausanne, 2002), a full session alternative event "Proteomic Application Exercise" was proposed. Two different samples were prepared and sent to the different participants: 100 micro g of snake venom (a complex mixture of peptides and proteins) and 10-20 micro g of almost pure recombinant polypeptide derived from the shrimp Penaeus vannamei carrying an heterogeneous post-translational modification (PTM). Among the 15 participants that received the samples blind, eight returned results and most of them were asked to present their results emphasizing the strategy, the manpower and the instrumentation used during the congress (Binz et. al., Proteomics 2003, 3, 1562-1566). It appeared that for the snake venom extract, the quality of the results was not particularly dependant on the strategy used, as all approaches allowed Lication of identification of a certain number of protein families. The genus of the snake was identified in most cases, but the species was ambiguous. Surprisingly, the precise identification of the recombinant almost pure polypeptides appeared to be much more complicated than expected as only one group reported the full sequence. Finally the SPS'03 meeting reported here included a round table on the difficult and challenging task of "Quantification by Mass Spectrometry", a discussion sustained by four selected oral presentations on the use of stable isotopes, electrospray ionization versus matrix-assisted laser desorption/ionization approaches to quantify peptides and proteins in biological fluids, the handling of differential two-dimensional liquid chromatography tandem mass spectrometry data resulting from high throughput experiments, and the quantitative analysis of PTMs. During these three events at the SPS meetings, the impressive quality and quantity of exchanges between the developers and providers of mass spectrometry equipment and software, expert users and the audience, were a key element for the success of these fruitful events and will have definitively paved the way for future round tables and challenging exercises at SPS meetings.
Resumo:
The purpose of this study was to measure postabsorptive fat oxidation at rest and to assess the association between fat mass and fat oxidation rate in prepubertal children, who were assigned to two groups: 35 obese children (weight, 44.5 +/- 9.7 kg; fat mass; 31.7 +/- 5.4%) and 37 nonobese children (weight, 30.8 +/- 6.8 kg; fat mass, 17.5 +/- 6.7%). Postabsorptive fat oxidation expressed in absolute value was significantly higher in obese than in nonobese children (31.4 +/- 9.7 mg/min vs 21.9 +/- 10.2 mg/min; p < 0.001) but not when adjusted for fat-free mass by analysis of covariance with fat-free mass as the covariate (28.2 +/- 10.6 mg/min vs 24.9 +/- 10.5 mg/min). In obese children and in the total group, fat mass and fat oxidation were significantly correlated (r = 0.65; p < 0.001). The slope of the relationship indicated that for each 10 kg additional fat mass, resting fat oxidation increased by 18 gm/day. We conclude that obese prepubertal children have a higher postabsorptive rate of fat oxidation than nonobese children. This metabolic process may favor the achievement of a new equilibrium in fat balance, opposing further adipose tissue gain.
Resumo:
A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.
Resumo:
The capabilities of a high-resolution (HR), accurate mass spectrometer (Exactive-MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50,000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive-MS was compared with that of a triple quadrupole mass spectrometer (TQ-MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole-N-oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR-MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR-MS offers several benefits over TQ-MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR-MS delivers comparable results to TQ-MS in routine quantitative drug analyses. Considering the advantages of HR-MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed.