313 resultados para intraocular prosthesis
Resumo:
Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.
Resumo:
L'évaluation des résultats des arthroplasties totales du genou demande une évaluation du geste thérapeutique ou clinique, mais doit également tenir compte de l'impact de ce geste sur l'état de santé global du patient (somatique, psychologique, social) et intégrer son degré de satisfaction. La complexité croissante des instruments de mesure du suivi a de quoi décourager le chirurgien praticien déjà surchargé par son activité clinique quotidienne. L'apparition des scores, des études prospectives et des analyses statistiques, telles les courbes de survie, ont certainement permis une appréciation plus objective de nos résultats, tout en accroissant nos connaissances et en améliorant notre pratique quotidienne. La question aujourd'hui n'est plus de savoir si un suivi clinique de nos patients est utile, mais plutôt de choisir les bons instruments et de définir les buts de l'analyse tout en cherchant comment implanter cette démarche de manière réaliste dans nos pratiques. Les scores classiques, aussi imparfaits soient-ils, restent pour l'instant utiles. Largement diffusés à travers le monde, appliqués de manière prospective, ces outils de suivi orientés vers la clinique et la radiologie sont le fondement du suivi prospectif des implants. Au quotidien, ils permettent un suivi en temps réel des implants d'un service ou d'une institution. Cependant, leur faiblesse intrinsèque résidant dans l'inaptitude à saisir le point de vue du patient, il semble inéluctable d'y adjoindre des instruments psychométriques. Dans l'avenir, la recherche devrait se concentrer vers le développement d'outils adaptés, capables de cerner avec une plus grande précision l'attente des patients et de technologies accessibles à chaque praticien pour mesurer objectivement les capacités fonctionnelles de leurs patients avec plus d'acuité. Le développement de systèmes permettant une évaluation objective de la fonction quotidienne du patient revêt un intérêt tout particulier. Parallèlement, un effort doit être fait au niveau des sociétés spécialisées nationales et internationales pour harmoniser leurs protocoles de suivi.
New formulation of vasoactive intestinal peptide using liposomes in hyaluronic acid gel for uveitis.
Resumo:
We evaluated the benefits of a novel formulation of vasoactive intestinal peptide (VIP) based on the incorporation of VIP-loaded rhodamine-conjugated liposomes (VIP-Rh-Lip) within hyaluronic acid (HA) gel (Gel-VIP-Rh-Lip) for the treatment of endotoxin-induced uveitis (EIU) in comparison with VIP-Rh-Lip alone. In vitro release study and rheological analysis showed that interactions between HA chains and liposomes resulted in increased viscosity and reinforced elasticity of the gel. In vivo a single intravitreal injection of Gel-VIP-Rh-Lip was performed in rats 7 days prior to uveitis induction by subcutaneous lipopolysaccharide injection. The maximal ocular inflammation occurs within 16-24 h in controls (VIP-Rh-Lip, unloaded-Rh-Lip). Whereas intraocular injection of VIP-Rh-Lip had no effect on EIU severity compared with controls, Gel-VIP-Rh-Lip reduced significantly the clinical score and number of inflammatory cells infiltrating the eye. The fate of liposomes, VIP and HA in the eyes, regional and inguinal lymph nodes and spleen was analyzed by immunostaining and fluorescence microscopy. Retention of liposomes by HA gel was observed in vitro and in vivo. Inflammation severity seemed to impact on system stability resulting in the delayed release of VIP. Thus, HA gel containing VIP-Rh-Lip is an efficient strategy to obtain a sustained delivery of VIP in ocular and lymph node tissues.
Resumo:
BACKGROUND: The aim of this communication is to describe an unusual and serious complication of retrobulbar anaesthesia for cataract surgery. HISTORY AND SIGNS: A 78-year-old female was referred for visual loss (light perception) 24 hours after apparently uneventful cataract surgery with retrobulbar anaesthesia in her left eye. Fundus examination revealed multiple arterial emboli and a localised retinal detachment. MRI revealed a retrobulbar hypersignal of the optic nerve associated with perineuritis. The cardiovascular examination was normal. We assumed this condition resulted from injection of the anaesthetic mixture into the optic nerve. THERAPY AND OUTCOME: In order to improve retinal circulation and oxygenation, the intraocular pressure was maximally lowered and anticalcic therapy administered, expecting optimal arterial dilatation. Methylprednisolone (1 g/day 3 days i. v., then rapidly tapered) was also added. The retina slowly reattached but visual acuity remained unchanged. CONCLUSIONS: Retrobulbar anaesthesia is routinely used for ocular surgery. Serious complications may still happen, however. This case adds to the previously reported spectrum of complications from retrobulbar anaesthesia.
Resumo:
Elbow arthroplasty is increasingly performed in patients with rheumatic and post-traumatic arthritis. Data on elbow periprosthetic joint infection (PJI) are limited. We investigated the characteristics and outcome of elbow PJI in a 14-year cohort of total elbow arthroplasties in a single centre. Elbow prosthesis, which were implanted between 1994 and 2007 at Schulthess Clinic in Zurich, were retrospectively screened for infection. PJI was defined as periprosthetic purulence, the presence of sinus tract or microbial growth. A Kaplan-Meier survival method and Cox proportional hazard analysis were performed. Of 358 elbow prostheses, PJI was identified in 27 (7.5%). The median patient age (range) was 61 (39-82) years; 63% were females. Seventeen patients (63%) had a rheumatic disorder and ten (37%) had osteoarthritis. Debridement and implant retention was performed in 78%, followed by exchange or removal of the prosthesis (15%) or no surgery (7%).The relapse-free survival (95% CI) was 79% (63-95%) after 1 year and 65% (45-85%) after 2 years. The outcome after 2 years was significantly better when patients were treated according to the algorithm compared to patients who were not (100% vs. 33%, p <0.05). In 21 patients treated with debridement and retention, the cure rate was also higher when the algorithm was followed (100% vs. 11%, p <0.05). The findings of the present study suggest that the treatment algorithm developed for hip and knee PJI can be applied to elbow PJI. With proper patient selection and antimicrobial therapy, debridement and retention of the elbow prosthesis is associated with good treatment outcome.
Resumo:
For successful treatment of prosthetic joint infection, the identification of the infecting microorganism is crucial. Cultures of synovial fluid and intraoperative periprosthetic tissue represent the standard method for diagnosing prosthetic joint infection. Rapid and accurate diagnostic tools which can detect a broad range of causing microorganisms and their antimicrobial resistance are increasingly needed. With newer diagnostic techniques, such as sonication of removed implants, microcalorimetry, molecular methods and mass spectrometry, the sensitivity has been significantly increased. In this article, we describe the conventional and newer diagnostic techniques with their advantages and potential future applications.
Resumo:
Stents have a long history in traditional valve surgery as both, porcine biological valves as well as pericardial valves are mounted on stents prior to implantation. Recently stent-mounted biological devices have been compressed up to the point, where they can be passed through a catheter. Various routes can be distinguished for implantation: open access, the trans-vascular route in antegrade or retrograde fashion, as well as direct trans-apical or trans-atrial access. Direct access has the potentialforvideo-endoscopic valve replacement. In theory, as well as in the experimental setting, valved stents have been implanted in tricuspid and caval position respectively, as well as in pulmonary, mitral and aortic locations. The largest clinical experience has been achieved in pulmonary position whereas current efforts target the aortic position.
Resumo:
BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
PURPOSE: To evaluate the long-term success rate and complications of nonpenetrating deep sclerectomy with collagen implant in open-angle glaucoma. PATIENTS AND METHODS: Clinical, prospective, monocentric, nonrandomized, unmasked study on 105 patients with medically uncontrolled glaucoma. A standard procedure deep sclerectomy with collagen implant was performed. Complete examinations were performed before surgery and postoperatively at 1 and 7 days; 1, 2, 3, 6, 9, and 12 months and then every 6 months during the 10 following years. RESULTS: The mean follow-up was 101.5+/-43.1 (3 to 144) months [mean+/-SD, (range)]. The preoperative intraocular pressure (IOP) was 26.8+/-7.7 (14 to 52) mm Hg and the best-corrected visual acuity 0.71+/-0.33 (0.02 to 1.5). Ten years after surgery IOP was 12.2+/-4.7 (6 to 20) mm Hg and best-corrected visual acuity 0.63+/-0.34 (0.01 to 1.2) (number of remaining patients=52). The mean number of medications per patient went from 2.3+/-0.7 (1 to 4) down to 1.3+/-1.1 (0 to 3). An IOP <or=21 mm Hg without medication was achieved in 47.7% patients and in 89% with or without treatment. One major complication was reported. Goniopuncture was performed in 61 eyes (59.8%), 5-fluorouracil treatment given to 25 patients postoperatively and included needling (n=5). CONCLUSIONS: On the basis of a 10-year follow-up deep sclerectomy with collagen implant demonstrated its efficacy in controlling IOP with few postoperative complications.
Resumo:
ABSTRACT : Background : The aim of this study was to evaluate the midterm biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. Methods : Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. [OP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. Results : For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. Conclusions : The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.
Resumo:
Introduction: Several methods have already been proposed to improve the mobility of reversed prostheses (lateral or inferior displacement, increase of the glenosphere size). However, the effect of these design changes have only been evaluated on the maximal range of motion and were not related to activities of daily living (ADL). Our aim was thus to measure the effect of these design changes and to relate it to 4 typical ADL. Methods: CT data were used to reconstruct a accurate geometric model of the scapula and humerus. The Aequalis reversed prosthesis (Tornier) was used. The mobility of a healthy shoulder was compared to the mobility of 4 different reversed designs: 36 and 42 mm glenospheres diameters, inferior (4 mm) and lateral (3.2 mm) glenospheres displacements. The complete mobility map of the prosthesis was compared to kinematics measurement on healthy subjects for 4 ADL: 1) hand to contra lateral shoulder, 2) hand to mouth, 3) combing hair, 4) hand to back pocket. The results are presented as percentage of the allowed movement of the prosthestic shouder relative to the healthy shoulder, considered as the control group. Results: None of the tested designs allowed to recover a full mobility. The differences of allowed range of motion among each prosthetic designs appeared mainly in two of the 4 movements: hand to back pocket and hand to contra lateral shoulder. For the hand to back pocket, the 36 had the lowest mobility range, particularly for the last third of the movement. The 42 appeared to be a good compromise for all ADL activities. Conclusion: Reverse shoulder prostheses does not allow to recover a full range of motion compared to healthy shoulders, even for ADL. The present study allowed to obtain a complete 3D mobility map for several glenosphere positions and sizes, and to relate it to typical ADL. We mainly observed an improved mobility with inferior displacement and increased glenosphere size. We would suggest to use larger glenosphere, whenever it is possible.
Resumo:
A 56-year-old patient admitted to hospital for the suspicion of an acute coronary syndrome underwent coronary angiography without detection of significant lesions. Seven days later the echocardiography showed acute severe aortic valve insufficiency. Intraoperatively we found a perforated leaflet probably due to lesion during transcatheter procedure.
Resumo:
Purpose: To compare the performance Glaucoma Quality of Life-15 (GQL-15) Questionnaire, intraocular pressure measurement (IOP Goldmann tonometry) and a measure of visual field loss using Moorfields Motion Displacement Test (MDT) in detecting glaucomatous eyes from a self referred population. Methods: The GQL-15 has been suggested to correlate with visual disability and psychophysical measures of visual function in glaucoma patients. The Moorfields MDT is a multi location perimetry test with 32 white line stimuli presented on a grey background on a standard laptop computer. Each stimulus is displaced between computer frames to give the illusion of "apparent motion". Participants (N=312, 90% older than 45 years; 20.5% family history of glaucoma) self referred to an advertised World Glaucoma Day (March 2009) Jules Gonin Eye Hospital, Lausanne Switzerland. Participants underwent a clinical exam (IOP, slit lamp, angle and disc examination by a general ophthalmologist), 90% completed a GQL-15 questionnaire and over 50% completed a MDT test in both eyes. Those who were classified as abnormal on one or more of the following (IOP >21 mmHg/ GQL-15 score >20/ MDT score >2/ clinical exam) underwent a follow up clinical examination by a glaucoma specialist including imaging and threshold perimetry. After the second examination subjects were classified as "healthy"(H), "glaucoma suspect" (GS) (ocular hypertension and/or suspicious disc, angle closure with SD) or "glaucomatous" (G). Results: One hundred and ten subjects completed all 4 initial examinations; of these 69 were referred to complete the 2nd examination and were classified as; 8 G, 24 GS, and 37 H. MDT detected 7/8 G, and 7/24 GS, with false referral rate of 3.8%. IOP detected 2/8 G and 8/24 GS, with false referral rate of 8.9%. GQL-15 detected 4/8 G, 16/24 GS with a false referral rate of 42%. Conclusions: In this sample of participants attending a self referral glaucoma detection event, the MDT performed significantly better than the GQL-15 and IOP in discriminating glaucomatous patients from healthy subjects. Further studies are required to assess the potential of the MDT as a glaucoma screening tool.