200 resultados para rotary instrumentation
Resumo:
Fibrin glue products and collagen patches are frequently used as a sealing product, preventing surgical side bleedings. This is especially true in the field of cardiovascular surgery, where increasing numbers of patients are being operated with antiplatelet and anticoagulation therapy. The aim of this report was, in an in vitro hemodynamic setting, to examine the sealant properties of the TachoSil (Nycomed Pharma, Linz, Austria) patch. Burst pressure and normal force of 15 TachoSil sealed defects were measured. This was determined in a closed hydraulic system. Mean burst pressure load for a 5-mm defect was 69+/-11.4 mmHg; for a 7-mm defect was 63+/-16 mmHg; and, 62+/-16 mmHg for the defect with a diameter of 10 mm (P>0.05). The mean calculated normal force was as follows: 0.91+/-0.15 N for the 5 mm defect, 6.5+/-1.6 N for the 7 mm, and 8.1+/-0.75 N for the 10 mm defect. The TachoSil patch has the capability to seal small defects. However, at the larger defects the seal character was significantly reduced. These results suggest that the device may be a good alternative for hemostasis for small defects. The capacity to curtail or stop hemorrhage at the larger defects is unlikely.
Resumo:
Since 2000 and the commercialisation of the Da Vinci robotic system, indications for robotic surgery are rapidly increasing. Recent publications proved superior functional outcomes with equal oncologic safety in comparison to conventional open surgery. Its field of application may extend to the nasopharynx and skull base surgery. The preliminary results are encouraging. This article reviews the current literature on the role of transoral robotic surgery in head and neck cancer.
Resumo:
Following the success of the first round table in 2001, the Swiss Proteomic Society has organized two additional specific events during its last two meetings: a proteomic application exercise in 2002 and a round table in 2003. Such events have as their main objective to bring together, around a challenging topic in mass spectrometry, two groups of specialists, those who develop and commercialize mass spectrometry equipment and software, and expert MS users for peptidomics and proteomics studies. The first round table (Geneva, 2001) entitled "Challenges in Mass Spectrometry" was supported by brief oral presentations that stressed critical questions in the field of MS development or applications (Stöcklin and Binz, Proteomics 2002, 2, 825-827). Topics such as (i) direct analysis of complex biological samples, (ii) status and perspectives for MS investigations of noncovalent peptide-ligant interactions; (iii) is it more appropriate to have complementary instruments rather than a universal equipment, (iv) standardization and improvement of the MS signals for protein identification, (v) what would be the new generation of equipment and finally (vi) how to keep hardware and software adapted to MS up-to-date and accessible to all. For the SPS'02 meeting (Lausanne, 2002), a full session alternative event "Proteomic Application Exercise" was proposed. Two different samples were prepared and sent to the different participants: 100 micro g of snake venom (a complex mixture of peptides and proteins) and 10-20 micro g of almost pure recombinant polypeptide derived from the shrimp Penaeus vannamei carrying an heterogeneous post-translational modification (PTM). Among the 15 participants that received the samples blind, eight returned results and most of them were asked to present their results emphasizing the strategy, the manpower and the instrumentation used during the congress (Binz et. al., Proteomics 2003, 3, 1562-1566). It appeared that for the snake venom extract, the quality of the results was not particularly dependant on the strategy used, as all approaches allowed Lication of identification of a certain number of protein families. The genus of the snake was identified in most cases, but the species was ambiguous. Surprisingly, the precise identification of the recombinant almost pure polypeptides appeared to be much more complicated than expected as only one group reported the full sequence. Finally the SPS'03 meeting reported here included a round table on the difficult and challenging task of "Quantification by Mass Spectrometry", a discussion sustained by four selected oral presentations on the use of stable isotopes, electrospray ionization versus matrix-assisted laser desorption/ionization approaches to quantify peptides and proteins in biological fluids, the handling of differential two-dimensional liquid chromatography tandem mass spectrometry data resulting from high throughput experiments, and the quantitative analysis of PTMs. During these three events at the SPS meetings, the impressive quality and quantity of exchanges between the developers and providers of mass spectrometry equipment and software, expert users and the audience, were a key element for the success of these fruitful events and will have definitively paved the way for future round tables and challenging exercises at SPS meetings.
Resumo:
The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery
Resumo:
Cet article se veut être un condensé des bases nécessaires à la pratique d'une ponction et, ou infiltration articulaire, des indications principales aux complications potentielles en passant par la description de la procédure et de ses contre-indications. La ponction du genou fait l'objet d'une description plus détaillée. Les données permettant de justifier une façon particulière de procéder ont spécifiquement été recherchées dans la littérature (Cochrane et Medline, termes de recherche : arthrocentesis ; joint aspiration). Le détail de ces données, comme par exemple le résultat d'études, ne trouve pas sa place dans ce résumé mais fait l'objet d'une publication à part. What should be known in order to practice safely a joint aspiration and/or infiltration is summarized in the following article. This summary includes various aspects, such as the indications and contraindications, the procedure itself, and the possible complications. The arthrocentesis of the knee is described in more details. Data in support of a specific modus operandi have been searched for in Cochrane and Pubmed (key words: arthrocentesis, joint aspiration). Only the conclusions of this research are exposed in this summary. A more comprehensive article will be published
Resumo:
For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.
Resumo:
OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.
Resumo:
A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.
Resumo:
Coronary artery fistulae represent the most frequent congenital anomalies of the coronary arteries, but remain a relatively uncommon clinical problem. Moreover, multiple fistulae originating from both the left and the right coronary arteries and draining into the left ventricular chamber are a rare condition. Due to the low prevalence of these anomalies, the appropriate management of patients with symptomatic coronary artery fistulae is controversial. Transcatheter closure approaches have emerged as a less invasive strategy and are nowadays considered a valuable alternative to surgical correction with similar effectiveness, morbidity and mortality. The percutaneous management, however, is mainly limited by the individual anatomic features of the fistula and an appropriate patient's selection is considered as a key determining factor to achieve complete occlusion. Thus, success rates of transcatheter closure techniques reported in the literature are extremely variable and highly dependent upon the nature of the follow up, which, at present, is not standardized. The optimal management of symptomatic patients with multiple coronary artery fistulae still remains a challenging problem and has been traditionally considered as an indication for cardiac surgery. We report here the case of a patient with double bilateral congenital coronary artery fistulae arising from both the left and right coronary arteries and draining individually into the left ventricular chamber. This patient underwent successful transcatheter anterograde closure of both fistulae using a microcoil embolization technique.
Resumo:
The spatial resolution visualized with hydrological models and the conceptualized images of subsurface hydrological processes often exceed resolution of the data collected with classical instrumentation at the field scale. In recent years it was possible to increasingly diminish the inherent gap to information from point like field data through the application of hydrogeophysical methods at field-scale. With regards to all common geophysical exploration techniques, electric and electromagnetic methods have arguably to greatest sensitivity to hydrologically relevant parameters. Of particular interest in this context are induced polarisation (IP) measurements, which essentially constrain the capacity of a probed subsurface region to store an electrical charge. In the absence of metallic conductors the IP- response is largely driven by current conduction along the grain surfaces. This offers the perspective to link such measurements to the characteristics of the solid-fluid-interface and thus, at least in unconsolidated sediments, should allow for first-order estimates of the permeability structure.¦While the IP-effect is well explored through laboratory experiments and in part verified through field data for clay-rich environments, the applicability of IP-based characterizations to clay-poor aquifers is not clear. For example, polarization mechanisms like membrane polarization are not applicable in the rather wide pore-systems of clay free sands, and the direct transposition of Schwarz' theory relating polarization of spheres to the relaxation mechanism of polarized cells to complex natural sediments yields ambiguous results.¦In order to improve our understanding of the structural origins of IP-signals in such environments as well as their correlation with pertinent hydrological parameters, various laboratory measurements have been conducted. We consider saturated quartz samples with a grain size spectrum varying from fine sand to fine gravel, that is grain diameters between 0,09 and 5,6 mm, as well as corresponding pertinent mixtures which can be regarded as proxies for widespread alluvial deposits. The pore space characteristics are altered by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples, while keeping any electrochemical variability during the measurements as small as possible. The results do not follow simple assumptions on relationships to single parameters such as grain size. It was found that the complexity of natural occurring media is not yet sufficiently represented when modelling IP. At the same time simple correlation to permeability was found to be strong and consistent. Hence, adaptations with the aim of better representing the geo-structure of natural porous media were applied to the simplified model space used in Schwarz' IP-effect-theory. The resulting semi- empiric relationship was found to more accurately predict the IP-effect and its relation to the parameters grain size and permeability. If combined with recent findings about the effect of pore fluid electrochemistry together with advanced complex resistivity tomography, these results will allow us to picture diverse aspects of the subsurface with relative certainty. Within the framework of single measurement campaigns, hydrologiste can than collect data with information about the geo-structure and geo-chemistry of the subsurface. However, additional research efforts will be necessary to further improve the understanding of the physical origins of IP-effect and minimize the potential for false interpretations.¦-¦Dans l'étude des processus et caractéristiques hydrologiques des subsurfaces, la résolution spatiale donnée par les modèles hydrologiques dépasse souvent la résolution des données du terrain récoltées avec des méthodes classiques d'hydrologie. Récemment il est possible de réduire de plus en plus cet divergence spatiale entre modèles numériques et données du terrain par l'utilisation de méthodes géophysiques, notamment celles géoélectriques. Parmi les méthodes électriques, la polarisation provoquée (PP) permet de représenter la capacité des roches poreuses et des sols à stocker une charge électrique. En l'absence des métaux dans le sous-sol, cet effet est largement influencé par des caractéristiques de surface des matériaux. En conséquence les mesures PP offrent une information des interfaces entre solides et fluides dans les matériaux poreux que nous pouvons lier à la perméabilité également dirigée par ces mêmes paramètres. L'effet de la polarisation provoquée à été étudié dans différentes études de laboratoire, ainsi que sur le terrain. A cause d'une faible capacité de polarisation des matériaux sableux, comparé aux argiles, leur caractérisation par l'effet-PP reste difficile a interpréter d'une manière cohérente pour les environnements hétérogènes.¦Pour améliorer les connaissances sur l'importance de la structure du sous-sol sableux envers l'effet PP et des paramètres hydrologiques, nous avons fait des mesures de laboratoire variées. En détail, nous avons considéré des échantillons sableux de quartz avec des distributions de taille de grain entre sables fins et graviers fins, en diamètre cela fait entre 0,09 et 5,6 mm. Les caractéristiques de l'espace poreux sont changées en modifiant (i) la distribution de taille des grains, (ii) le degré de compaction, et (iii) le niveau d'hétérogénéité dans la distribution de taille de grains. En suite nous étudions comment ces changements influencent l'effet-PP, la perméabilité et la surface spécifique des échantillons. Les paramètres électrochimiques sont gardés à un minimum pendant les mesures. Les résultats ne montrent pas de relation simple entre les paramètres pétro-physiques comme par exemples la taille des grains. La complexité des media naturels n'est pas encore suffisamment représenté par les modèles des processus PP. Néanmoins, la simple corrélation entre effet PP et perméabilité est fort et consistant. En conséquence la théorie de Schwarz sur l'effet-PP a été adapté de manière semi-empirique pour mieux pouvoir estimer la relation entre les résultats de l'effet-PP et les paramètres taille de graines et perméabilité. Nos résultats concernant l'influence de la texture des matériaux et celles de l'effet de l'électrochimie des fluides dans les pores, permettront de visualiser des divers aspects du sous-sol. Avec des telles mesures géo-électriques, les hydrologues peuvent collectionner des données contenant des informations sur la structure et la chimie des fluides des sous-sols. Néanmoins, plus de recherches sur les origines physiques de l'effet-PP sont nécessaires afin de minimiser le risque potentiel d'une mauvaise interprétation des données.
Resumo:
PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.
Resumo:
The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
pH monitoring has been used as a diagnostic tool in gastro-oesophageal reflux disease (GERD) for many years. Recent studies have shown that wireless capsule pH monitoring is better tolerated and interferes less with daily activities as compared to traditional catheter-based pH monitoring. Moreover, prolonged recording time (48 h instead of 24 h) is possible with wireless pH monitoring. The main secondary effect of wireless capsule pH monitoring is induction of thoracic discomfort in 10-65% of the patients, which can vary from mild foreign body sensation to severe chest pain. Sensitivity and specificity of wireless capsule monitoring is comparable to that of traditional pH monitoring. It has not been proven yet that better tolerability and a longer recording time increases the diagnostic yield of wireless capsule monitoring in GERD.