206 resultados para prosthesis pigmentation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eumelanin and pheomelanin are the main endogenous pigments in animals and melanin-based coloration has multiple functions. Melanization is associated with major life-history traits, including immune and stress response, possibly because of pleiotropic effects of genes that control melanogenesis. The net effects on pheo- versus eumelanization and other life-history traits may depend on the antagonistic effects of the genes that trigger the biosynthesis of either melanin form. Covariation between melanin-based pigmentation and fitness traits enforced by pleiotropic genes has major evolutionary implications particularly for socio-sexual communication. However, evidence from non-model organisms in the wild is limited to very few species. Here, we tested the hypothesis that melanin-based coloration of barn swallow (Hirundo rustica) throat and belly feathers covaries with acquired immunity and activation of the hypothalamic-pituitary-adrenal (HPA) axis, as gauged by corticosterone plasma levels. Individuals of both sexes with darker brownish belly feathers had weaker humoral immune response, while darker males had higher circulating corticosterone levels only when parental workload was experimentally reduced. Because color of belly feathers depends on both eu- and pheomelanin, and its darkness decreases with an increase in the concentration of eu- relative to pheomelanin, these results are consistent with our expectation that relatively more eu- than pheomelanized individuals have better immune response and smaller activation of the HPA-axis. Covariation of immune and stress response arose for belly but not throat feather color, suggesting that any function of color as a signal of individual quality or of alternative life-history strategies depends on plumage region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Articular surfaces reconstruction is essential in total shoulder arthroplasty. Because of the limited glenoid bone support, thin glenoid component could improve anatomical reconstruction, but adverse mechanical effects might appear. METHODS: With a numerical musculoskeletal shoulder model, we analysed and compared three values of thickness of a typical all-polyethylene glenoid component: 2, 4 (reference) and 6mm. A loaded movement of abduction in the scapular plane was simulated. We evaluated the humeral head translation, the muscle moment arms, the joint force, the articular contact pattern, and the polyethylene and cement stress. Findings Decreasing polyethylene thickness from 6 to 2mm slightly increased humeral head translation and muscle moment arms. This induced a small decreased of the joint reaction force, but important increase of stress within the polyethylene and the cement mantel. Interpretation The reference thickness of 4mm seems a good compromise to avoid stress concentration and joint stuffing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Polyethylene wear is a recurrent problem in joint arthroplasty. Small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living. Material and Methods: A numerical musculoskeletal model of the glenohumeral joint was used for this comparative study. The reversed (RP) and anatomic (AP) Aequalis prostheses were positioned in the numerical model. Eight levels of abduction were considered. Their daily frequency was estimated from in-vivo recorded data on healthy volunteers during activities of daily living. One year of use was simulated to predict the linear and volumetric wear. The volumetric wear was the difference of volume between the original and worn component. Results: With the AP, the contact pattern on the glenoid surface moved rapidly from the inferior to the superior side during the first 30 degrees of abduction, and then went back to the inferior side. With the RP, the contact pattern on the humeral cup surface remained at the inferior side. Contact pressure was 20 times lower with the RP than with the AP. One year of use produced a maximum linear wear of 0.2 mm with the AP, and 0.13 mm with the RP. However, the volumetric wear was 8.4 mm3 with the AP, but reached 44.6 mm3 with the RP. Conclusion: Polyethylene particles are a matter of concern with AP. Infiltration of these particles within the bone-implant interface can induce a implant loosening. This problem should not be underestimated with RP. It might be associated to a higher level of humeral stem loosening reported with RP. The long term survival of RP might be improved by using a highly cross-linked polyethylene, which has a better abrasion resistance but lower plastic resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This systematic review aims to assess the risks (both thromboembolic and bleeding) of an oral anticoagulation therapy (OAT) patient undergoing implant therapy and to provide a management protocol to patients under OAT undergoing implant therapy. MATERIAL AND METHODS: Medline, Cochrane Data Base of Systematic Reviews, the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. This search was completed by a hand research accessing the references cited in all identified publications. RESULTS: Nineteen studies were identified reporting outcomes after oral surgery procedures (mostly dental extractions in patients on OAT following different management protocols and haemostatic therapies). Five studies were randomized-controlled trials (RCTs), 11 were controlled clinical trials (CCTs) and three were prospective case series. The OAT management strategies as well as the protocols during and after surgery were different. This heterogeneity prevented any possible data aggregation and synthesis. The results from these studies are very homogeneous, reporting minor bleeding in very few patients, without a significant difference between the OAT patients who continue with the vitamin K antagonists vs. the patients who stopped this medication before surgery. These post-operative bleeding events were controlled only with local haemostatic measures: tranexamic acid mouthwashes, gelatine sponges and cellulose gauzes's application were effective. Post-operative bleeding did not correlate with the international normalised ratio (INR) status. In none of the studies was a thromboembolic event reported. CONCLUSIONS: OAT patients (INR 2-4) who do not discontinue the AC medication do not have a significantly higher risk of post-operative bleeding than non-OAT patients and they also do not have a higher risk of post-operative bleeding than OAT patients who discontinue the medication. In patients with OAT (INR 2-4) without discontinuation, topical haemostatic agents were effective in preventing post-operative bleeding. OAT discontinuation is not recommended for minor oral surgery, such as single tooth extraction or implant placement, provided that this does not involve autogenous bone grafts, extensive flaps or osteotomy preparations extending outside the bony envelope. Evidence does not support that dental implant placement in patients on OAT is contraindicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:Coats' disease is a non-hereditary condition characterized by idiopathic retinal telangiectasia, and exudative retinopathy. Although the exudation often spreads from the main areas of telangiectasia, there is a preferential accumulation of exudation in the macular area in Coats' disease. A subfoveal nodule has usually been described in the context of resolution of macular exudates after treatment of peripheral retinal telangiectasis. Nevertheless, a recent reports stressed out an uncommon prominent subfoveal nodule with peripheral exudates as initial presentation of Coats'disease. The purpose of this study was to report the prevalence of this presentation in a cohort of patients. Methods:All consecutive patients with Coats' disease referred to the Jules Gonin Eye Hospital between January 1979 and July 2006 were included. All charts were screened for a clear cut subfoveal circular lesion on fundus photographies at initial presentation. Results:95 patients suffering of Coat's disease were enrolled. 33 out of 95 patients had subtotal or total exudative retinal detachment, which impeded macular examination. 14 out of 62 (22.6%) resting patients presented with a clear cut prominent circular subfoveal lesion at initial presentation. All patients had unilateral disease. Mean age was 5.6 ± 3.5 year old at initial presentation. There were 4 females and 10 males. Pigmentation and size of the nodule were not homogenous. Mean diameter was 1.1 ± 0.5 optic disc diameter. Conclusions:The present study shows that subfoveal nodule is not such a rare primary presentation of Coats' disease in contrast to what it has been previously reported in the literature. Thus the initial finding of prominent subfoveal nodule associated with peripheral retinal findings made the diagnosis of Coats' disease highly likely.Physicians should be aware that a proeminent subfoveal nodule is a common initial presentation of Coats' disease as it can be confused clinically with Retinoblastoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antibiotic prophylaxis is commonly prescribed to patients with total arthroplasties before a dental intervention. This attitude is not evidence-based for several reasons: 1) the usual pathogens of prosthetic joint infections are not of oral origin; 2) even if given, systemic antibiotic do not completely suppress the occult bacteraemia occurring during dental intervention and 3) humans may have up to twelve episodes of occult bacteraemia of dental origin per day. Routine antibiotic prophylaxis should be clearly distinguished from the antibiotic treatment required in case of established oral cavity infection. A constant optimal oral and dental hygiene is more important in terms of prevention and should be routinely recommended to every patient carrying a joint arthroplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hypothesis that ornaments can honestly signal quality only if their expression is condition-dependent has dominated the study of the evolution and function of colour traits. Much less interest has been devoted to the adaptive function of colour traits for which the expression is not, or is to a low extent, sensitive to body condition and the environment in which individuals live. The aim of the present paper is to review the current theoretical and empirical knowledge of the evolution, maintenance and adaptive function of colour plumage traits for which the expression is mainly under genetic control. The finding that in many bird species the inheritance of colour morphs follows the laws of Mendel indicates that genetic colour polymorphism is frequent. Polymorphism may have evolved or be maintained because each colour morph facilitates the exploitation of alternative ecological niches as suggested by the observation that individuals are not randomly distributed among habitats with respect to coloration. Consistent with the hypothesis that different colour morphs are linked to alternative strategies is the finding that in a majority of species polymorphism is associated with reproductive parameters, and behavioural, life-history and physiological traits. Experimental studies showed that such covariations can have a genetic basis. These observations suggest that colour polymorphism has an adaptive function. Aviary and field experiments demonstrated that colour polymorphism is used as a criterion in mate-choice decisions and dominance interactions confirming the claim that conspecifics assess each other's colour morphs. The factors favouring the evolution and maintenance of genetic variation in coloration are reviewed, but empirical data are virtually lacking to assess their importance. Although current theory predicts that only condition-dependent traits can signal quality, the present review shows that genetically inherited morphs can reveal the same qualities. The study of genetic colour polymorphism will provide important and original insights on the adaptive function of conspicuous traits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy. DESIGN: A retrospective study over a 20-month period from a single centre. PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included. METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage. RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation. CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the safety and efficacy of stenting in upper airway reconstructions for benign laryngotracheal stenosis (LTS) with a newly designed prosthesis, the LT-Mold?. The LT-Mold and its proper use during open surgery and endoscopy are described, and the experience gathered from a prospectively collected database on 65 patients treated for complex LTS or severe aspiration is reported. This series is compared to the results of other stenting methods. All patients were available for evaluation. In all but one case, the prosthesis was removed at the end of the study. The new prosthesis did not induce any stent-related trauma to the supraglottis, glottis and subglottis. Before adding a distal round-shaped silicone cap to the LT-Mold, granulation tissue was usually seen at the stent-mucosal interface at the tracheostoma level. In 14 cases, there has been a spontaneous extrusion of the prosthesis through the mouth; this problem was solved by fixing the prosthesis through the reinforced portion of the prosthesis at the cap level and by adding one fixation stitch in the supraglottis. We have to document the loss of the silicone cap in three cases. This problem was resolved by designing a new prototype with an integrated cap, glued with a slow hardening silicone glue. Fifty-four (83 %) of 65 patients were decannulated after a mean duration of stenting of 3 months (range 1-12 months). The mean follow-up after decannulation was 23 months (range 1 month to 10 years). The experience gathered with the LT-Mold shows that long-term stenting for complex LTS is safely achieved when the prosthesis is used with its distal integrated silicone cap. The softness and smoothness of the prosthesis with a round-shaped configuration of both extremities help avoid ulceration and granulation tissue formation in the reconstructed airway. Adequate fixation is mandatory to avoid extrusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Aortoplasty has been advocated for moderate dilatation of the ascending aorta associated with aortic valve disease. We report our results with this conservative approach. METHODS: Seventeen consecutive patients with unsupported aortoplasty were reviewed. Twelve patients had aortic valve regurgitation and 5 had stenosis. The aortic wall was analyzed histologically in 14 patients. Follow-up was complete, with a mean time of 6 years (range, 2.3 to 10.5 years). RESULTS: Two patients among the 15 hospital survivors died during follow-up of causes unrelated to aortic pathology. Survival at 7 years was 86.7% (+/- 8.8%). Recurring aortic aneurysms developed in 4 patients after a mean time of 63 months, with an event-free survival at 7 years of 41% (+/- 21%). All of these 4 patients had aortic valve regurgitation and cystic medial necrosis. CONCLUSIONS: The recurrence rate of aneurysms after unsupported aortoplasty and aortic valve replacement is high in patients with aortic regurgitation. This strongly suggests that in these patients, the aortic dilatation is related to an underlying wall deficiency, associated with the aortic valve pathology, rather than to the hemodynamic stress imposed by the aortic valve disease.