258 resultados para free pulse
Resumo:
The debate about Free Will has been in the human mind for centuries, but has become even more intense with the recent scientific findings adding new lights on the problem. This interdisciplinary explosion of interest for the topic has brought many insightful knowledge, but also a great deal of epistemological problems. We think that those epistemological problems are deeply related to the very definition of Free Will and how this definition interacts with the interpretations of experimental results. We will thus outline a few of these problems and then propose a definition of Free Will which takes into account those epistemological pitfalls.
Resumo:
Caprine and ovine IgA were identified by cross-reaction with anti-human and anti-bovine IgA sera in colostrum, mature milk, saliva, urine and serum. Secretory component (SC) was shown in the free form and associated with polymeric serum IgA in secretions. Mean molecular weights were determined for the IgA and the free secretory components. The high IgA content of saliva suggested that it was a major secretory immunoglobulin in these species. Traces of secretory IgA were also found in normal sera but most of the serum IgA had no secretory determinant. Secretory IgA, serum IgA and free secretory component were purified. Levels of the sheep and goat immunoglobulins were measured in various fluids.
Resumo:
Background: The anti-angiogenic drug, bevacizumab (Bv), is currently used in the treatment of different malignancies including breast cancer. Many angiogenesis-associated molecules are found in the circulation of cancer patients. Until now, there are no prognostic or predictive factors identified in breast cancer patients treated with Bv. We present here the first results of the prospective monitoring of 6 angiogenesis-related molecules in the peripheral blood of breast cancer patients treated with a combination of Bv and PLD in the phase II trial, SAKK 24/06. Methods: Patients were treated with PLD (20 mg/m2) and Bv (10 mg/kg) on days 1 and 15 of each 4-week cycle for a maximum of 6 cycles, followed by Bv monotherapy maintenance (10 mg/m2 q2 weeks) until progression or severe toxicity. Plasma and serum samples were collected at baseline, after 2 months of therapy, then every 3 months and at treatment discontinuation. Enzyme-linked immunosorbent assays (Quantikine, R&D Systems and Reliatech) were used to measure the expression levels of human vascular endothelial growth factor (hVEGF), placental growth factor (hPlGF), matrix metalloproteinase 9 (hMMP9) and soluble VEGF receptors hsVEGFR-1, hsVEGFR-2 and hsVEGFR-3. The log-transformed data (to reduce the skewness) for each marker was analyzed using an analysis of variance (ANOVA) model to determine if there was a difference between the mean of the subgroups of interest (where α = 0.05). The untransformed data was also analyzed in the same manner as a "sensitivity" check. Results: 132 blood samples were collected in 41 out of 43 enrolled patients. Baseline levels of the molecules were compared to disease status according to RECIST. There was a statistically significant difference in the mean of the log-transformed levels of hMMP9 between responders [CR+PR] versus the mean in patients with PD (p-value=0.0004, log fold change=0.7536), and between patients with disease control [CR+PR+SD] and those with PD (p-value=<0.0001, log fold change=0.81559), with the log-transformed level of hMMP9 being higher for the responder group. The mean of the log-transformed levels of hsVEGFR-1 was statistically significantly different between patients with disease control [CR+PR+SD] and those with PD (p-value=0.0068, log fold change=-0.6089), where the log-transformed level of hsVEGFR-1 was lower for the responder group. The log-transformed level of hMMP9 at baseline was identified as a significant prognostic factor in terms of progression free survival (PFS): p-value=0.0417, hazard ratio (HR)=0.574 with a corresponding 95% confidence interval (0.336 - 0.979)). No strong correlation was shown either between the log-transformed levels of hsVEGF, hPlGF, hsVEGFR-2 or hsVEGFR-3 and clinical response or the occurrence of severe toxicity, or between the levels of the different molecules. Conclusions: Our results suggest that baseline plasma level of the matrix metalloproteinase, hMMP9, could predict tumor response and PFS in patients treated with a combination of Bv and PLD. These data justify further investigation in breast cancer patients treated with anti-angiogenic therapy.
Resumo:
A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.
Resumo:
Non-Hodgkin's lymphoma (NHL) comprises both indolent forms, including follicular lymphoma (FL) and marginal zone lymphoma (MZL), and aggressive forms, including diffuse large B-cell lymphoma (DLBCL) and mantle cell lymphoma (MCL). FL and DLBCL are the most common subtypes of indolent and aggressive NHL, respectively. Although these lymphomas exhibit different clinical behaviors and outcomes, the prognosis is negatively affected in both DLBCL and FL by the lack of a complete response (CR) with standard treatment options. The aim of therapy should therefore be achievement of a CR, which is not only associated with longer progression-free survival (PFS) and overall survival times, but is also a prerequisite for a cure, particularly in DLBCL. Consolidation treatment with radioimmunotherapy (RIT) is an innovative treatment approach to increase CR rates. Phase II studies have indicated promising results with yttrium-90 ((90)Y)-ibritumomab tiuxetan and iodine-131 ((131)I)-tositumomab as consolidation following induction therapy for previously untreated patients with advanced FL. More recently, investigators reported a marked increase in CR rates and significant improvements in PFS using standard chemotherapy regimens followed by (90)Y-ibritumomab tiuxetan in a phase III randomized trial in patients with previously untreated FL. Data also suggest that RIT may play a role in the treatment of high-risk DLBCL, with encouraging PFS results from a phase II trial of (90)Y-ibritumomab tiuxetan consolidation following induction with rituximab plus chemotherapy in elderly patients with previously untreated DLBCL. With the higher CR rates and longer PFS times observed in patients with FL and DLBCL, as well as encouraging early data from MZL and MCL consolidation trials, RIT appears to have an important role in the treatment of patients with NHL.
Resumo:
The action of individual type II DNA topoisomerases has been followed in real time by observing the elastic response of single DNA molecules to sequential strand passage events. Micromanipulation methods provide a complementary approach to biochemical studies for investigating the mechanism of DNA topoisomerases.
Resumo:
Two-dimensional (2D)-breath-hold coronary magnetic resonance angiography (MRA) has been shown to be a fast and reliable method to depict the proximal coronary arteries. Recent developments, however, allow for free-breathing navigator gated and navigator corrected three-dimensional (3D) coronary MRA. These 3D approaches have potential for improved signal-to-noise ratio (SNR) and allow for the acquisition of adjacent thin slices without the misregistration problems known from 2D approaches. Still, a major impediment of a 3D acquisition is the increased scan time. The purpose of this study was the implementation of a free-breathing navigator gated and corrected ultra-fast 3D coronary MRA technique, which allows for scan times of less than 5 minutes. Twelve healthy adult subjects were examined in the supine position using a navigator gated and corrected ECG triggered ultra-fast 3D interleaved gradient echo planar imaging sequence (TFE-EPI). A 3D slab, consisting of 20 slices with a reconstructed slice thickness of 1.5 mm, was acquired with free-breathing. The diastolic TFE-EPI acquisition block was preceded by a T2prep pre-pulse, a diaphragmatic navigator pulse, and a fat suppression pre-pulse. With a TR of 19 ms and an effective TE of 5.4 ms, the duration of the data acquisition window duration was 38 ms. The in-plane spatial resolution was 1.0-1.3 mm*1.5-1.9 mm. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and right coronary artery (RCA) could be visualized with an average scan time for the entire 3D-volume data set of 2:57 +/- 0:51 minutes. Average contiguous vessel length visualized was 53 +/- 11 mm (range: 42 to 75 mm) for the LAD and 84 +/- 14 mm (range: 62 to 112 mm) for the RCA. Contrast-to-noise between coronary blood and myocardium was 5.0 +/- 2.3 for the LM/LAD and 8.0 +/- 2.9 for the RCA, resulting in an excellent suppression of myocardium. We present a new approach for free-breathing 3D coronary MRA, which allows for scan times superior to corresponding 2D coronary MRA approaches, and which takes advantage of the enhanced SNR of 3D acquisitions and the post-processing benefits of thin adjacent slices. The robust image quality and the short average scanning time suggest that this approach may be useful for screening the major coronary arteries or identification of anomalous coronary arteries. J. Magn. Reson. Imaging 1999;10:821-825.
Resumo:
The objective of this study was to investigate the relationship between the physical activity (PA) and its related variables under confinement and in free-living conditions in Asian individuals, where no such information presently exists. The subjects consisted of eighty-six Japanese individuals with a mean age of 38+/-12 years. Under confinement in a large respiratory chamber, the energy expenditure (EE) was measured for 24h. In addition, two moderate walking exercises of 30 min each on a horizontal treadmill were assigned. Free-living measurements of 7 days were also performed using a validated accelerometer. The PA level in the chamber (1.47+/-0.11), expressed as a multiple of the basal EE, was lower than that in free-living conditions (1.53+/-0.12) (p<0.001). However, the two values were closely correlated (r=0.744, p<0.001). Conversely, a residual analysis showed a wide variation in the mean difference for both conditions and revealed a significant systematic error (r=-0.548, p<0.001), thus indicating an increased gap with increasing PA levels in free-living conditions. Similar results were obtained following the exclusion of the imposed exercise sessions. In contrast, the daily step counts under both conditions did not show any correlation. The PA level in the chamber (including and excluding imposed walking exercises) is compatible with the PA level in free-living conditions at the group level, although the daily step counts are unrelated. Thus, the PA level in the chamber may provide valuable information to help us achieve a better understanding of human PA in daily life as it is related to behavioral research.
Resumo:
RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.
Resumo:
PURPOSE: To describe methods and outcomes of excisional revision of a filtering bleb (bleb revision) using free conjunctival autologous graft either for bleb repair or for bleb reduction after trabeculectomy and deep sclerectomy with an implant. METHODS: Retrospective medical records were reviewed for a consecutive non-comparative case series comprising patients who underwent excisional revision of a filtering bleb between May 1998-January 2001. Excisional revision using free conjunctival autologous graft (bleb revision) was performed either for bleb repair, to treat early and late leaks and hypotony with maculopathy, or for bleb reduction, to improve ocular pain, discomfort, burning, foreign body sensation, tearing, and fluctuations of visual acuity. The revision consisted of bleb excision and free conjunctival autologous graft. The bleb histopathology was analyzed in patients who underwent bleb repair. RESULTS: Sixteen patients were included in the study, consisting of nine patients who had a trabeculectomy and seven patients who had a deep sclerectomy with an implant. Bleb revision was necessary in 14 patients due to leaking filtering bleb (bleb repair), and in 2 patients due to bleb dysesthesia (bleb reduction). After a follow-up of 15.1 +/- 8.4 months, the mean intraocular pressure (IOP) rose from 7.8 +/- 6.3 mm Hg to 14.3 +/- 6.5 mm Hg, and the visual acuity from 0.4 +/- 0.3 to 0.7 +/- 0.3, with a P value of 0.008 and 0.03, respectively. The complete success rate at 32 months, according to the Kaplan-Meier survival curve, was 38.3%, and the qualified success rate was 83.3%. Four patients (25%) required additional suturing for persistent bleb leak. To control IOP, antiglaucoma medical therapy was needed for six patients (37.5%) and repeated glaucoma surgery was needed for one patient. CONCLUSION: Free conjunctival autologous graft is a safe and successful procedure for bleb repair and bleb reduction. However, patients should be aware of the postoperative possibility of requiring medical or surgical intervention for IOP control after revision.
Resumo:
La rigidité anormalement haute des artères à grande conductance est un marqueur de l'augmentation du risque cardiovasculaire et est typiquement retrouvée chez les patients diabétiques ou hypertendus. Ces vaisseaux deviennent plus rigides avec l'âge, expliquant la haute prévalence d'hypertension systolique chez les personnes âgées. Cette rigidification agit sur la pression sanguine de plusieurs façons. Notamment la fonction windkessel est gênée, menant à l'augmentation de la pression systolique et de la pression puisée, la diminution de la pression diastolique, et ainsi à l'augmentation de la postcharge ventriculaire gauche associée à une probable diminution de la perfusion coronarienne. De plus, la propagation des ondes de pression le long de l'arbre vasculaire est accélérée, de sorte que les ondes réfléchies générées au site de décalage d'impédance atteignent l'aorte ascendante plus tôt par rapport au début de l'éjection ventriculaire, aboutissant à une augmentation de la pression systolique centrale, ce qui n'arriverait pas en présence de vaisseaux moins rigides. Dans ce cas, au contraire, les ondes de pression antérogrades et réfléchies voyages plus lentement, de sorte que les ondes de réflexion tendent à atteindre l'aorte centrale une fois l'éjection terminée, augmentant la pression diastolique et contribuant à la perfusion coronarienne. La tonométrie d'applanation est une méthode non invasive permettant l'évaluation de la forme de l'onde de pression au niveau l'aorte ascendante, basée sur l'enregistrement du pouls périphérique, au niveau radial dans notre étude. Nous pouvons dériver à partir de cette méthode un index d'augmentation systolique (sAIX) qui révèle quel pourcentage de la pression centrale est du aux ondes réfléchies. Plusieurs études ont montré que cet index est corrélé à d'autres mesures de la rigidité artérielle comme la vitesse de l'onde de pouls, qu'il augmente avec l'âge et avec les facteurs de risques cardiovasculaires, et qu'il est capable de préciser le pronostic cardiovasculaire. En revanche, peu d'attention a été portée à l'augmentation de la pression centrale diastolique due aux ondes réfléchies (dAIX). Nous proposons donc de mesurer cet index par un procédé d'analyse développé dans notre laboratoire, et ce dans la même unité que l'index systolique. Etant donné que les modifications de la paroi artérielle modulent d'une part la vitesse de l'onde de pouls (PWV) et d'autre part le temps de voyage aller-retour des ondes de pression réfléchies aux sites de réflexion, toute augmentation de la quantité d'énergie réfléchie atteignant l'aorte pendant la systole devrait être associée à une diminution de l'énergie arrivant au même point pendant la diastole. Notre étude propose de mesurer ces deux index, ainsi que d'étudier la relation de l'index d'augmentation diastolique (dAIX) avec la vitesse de propagation de l'onde de pouls (PWV) et avec le rythme cardiaque (HR), ce dernier étant connu pour influencer l'index d'augmentation systolique (sAIX) . L'influence de la position couchée et assise est aussi étudiée. Les mesures de la PWV et des sAIX et dAIX est réalisée chez 48 hommes et 45 femmes âgées de 18 à 70 ans, classés en 3 groupes d'âges. Les résultats montrent qu'en fonction de l'âge, le genre et la position du corps, il y a une relation inverse entre sAIX et dAIX. Lorsque PWV et HR sont ajoutés comme covariables à un modèle de prédiction comprenant l'âge, le genre et la position du corps comme facteurs principaux, sAIX est directement lié à PWV (p<0.0001) et inversement lié à HR (p<0.0001). Avec la même analyse, dAIX est inversement lié à PWV (p<0.0001) et indépendant du rythme cardiaque (p=0.52). En conclusion, l'index d'augmentation diastolique est lié à la rigidité vasculaire au même degré que l'index d'augmentation systolique, alors qu'il est affranchi de l'effet confondant du rythme cardiaque. La quantification de l'augmentation de la pression aortique diastolique due aux ondes réfléchies pourrait être une partie utile de l'analyse de l'onde de pouls.
Resumo:
Serum-free aggregating brain cell cultures are free-floating three-dimensional primary cell cultures able to reconstitute spontaneously a histotypic brain architecture to reproduce critical steps of brain development and to reach a high level of structural and functional maturity. This culture system offers, therefore, a unique model for neurotoxicity testing both during the development and at advanced cellular differentiation, and the high number of aggregates available combined with the excellent reproducibility of the cultures facilitates routine test procedures. This chapter presents a detailed description of the preparation, maintenance, and use of these cultures for neurotoxicity studies and a comparison of the developmental characteristics between cultures derived from the telencephalon and cultures derived from the whole brain. For culture preparation, mechanically dissociated embryonic brain tissue is used. The initial cell suspension, composed of neural stem cells, neural progenitor cells, immature postmitotic neurons, glioblasts, and microglial cells, is kept in a serum-free, chemically defined medium under continuous gyratory agitation. Spherical aggregates form spontaneously and are maintained in suspension culture for several weeks. Within the aggregates, the cells rearrange and mature, reproducing critical morphogenic events, such as migration, proliferation, differentiation, synaptogenesis, and myelination. For experimentation, replicate cultures are prepared by the randomization of aggregates from several original flasks. The high yield and reproducibility of the cultures enable multiparametric endpoint analyses, including "omics" approaches.
Resumo:
Rapport de synthèse Ce travail de thèse s'articule autour de l'importance de l'évaluation de la fonction vasculaire et des répercussions au niveau central, cardiaque, des perturbations du réseau vasculaire. Les maladies cardiovasculaires sont prédominantes dans notre société et causes de morbidité et mortalité importante. La mesure de la pression artérielle classique reste le moyen le plus utilisé pour suivre la santé des vaisseaux, mais ne reflète pas directement ce qui se passe au niveau du coeur. La tonométrie d'aplanation permet depuis quelques années de mesurer l'onde de pouls radial, et par le biais d'une fonction mathématique de transfert validée, il est possible d'en déduire la forme et Γ amplitude de l'onde de pouls central, donc de la pression aortique centrale. Cette dernière est un reflet bien plus direct de la post-charge cardiaque, et de nombreuses études cliniques actuelles s'intéressent à cette mesure pour stratifier le risque ou évaluer l'effet d'un traitement vasculaire. Toutefois, bien que cet outil soit de plus en plus utilisé, il est rarement précisé si la latéralité de la mesure joue un rôle, sachant que certaines propriétés des membres supérieurs peuvent être affectées par un usage préférentiel (masse musculaire, densité osseuse, diamètre des artères, capillarisation musculaire, et même fonction endothéliale). On a en effet observé que ces divers paramètre étaient tous augmentés sur un bras entraîné. Dès lors on peut se poser la question de l'influence de ces adaptations physiologiques sur la mesure indirecte effectuée par le biais du pouls radial. Nous avons investigué les deux membres supérieurs de sujets jeunes et sédentaires (SED), ainsi que ceux de sujets sportifs avec un développement fortement asymétrique des bras, soit des joueurs de tennis de haut niveau (TEN). Des mesures anthropométriques incluant la composition corporelle et la circonférence des bras et avant-bras ont montré que TEN présente une asymétrie hautement significative aux deux mesures entre le bras dominant (entraîné) et l'autre, ce qui est aussi présent pour la force de serrage (mesurée au dynamomètre de Jamar). L'analyse des courbes centrales de pouls ne montre aucune différence entre les deux membres dans chaque groupe, par contre on peut observer une différence entre SED et TEN, avec un index d'augmentation diastolique qui est 50 % plus élevé chez TEN. Les index d'augmentation systolique sont identiques dans les deux groupes. On peut retenir de cette étude la validité de la méthode de tonométrie d'aplanation quel que soit le bras utilisé (dominant ou non-dominant) et ce même si une asymétrie conséquente est présente. Ces données sont clairement nouvelles et permettent de s'affranchir de cette variable dans la mesure d'un paramètre cardiovasculaire dont l'importance est actuellement grandissante. Les différences d'index diastolique sont expliquées par la fréquence cardiaque et la vitesse de conduction de l'onde de pouls plus basses chez TEN, causant un retard diastolique du retour de l'onde au niveau central, phénomène précédemment bien décrit dans la littérature.