149 resultados para CALIBRATION
Resumo:
Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.
Resumo:
In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.
Resumo:
Oceans, or other wide expanses of inhospitable environment, interrupt present day distributions of many plant groups. Using molecular dating techniques, generally incorporating fossil evidence, we can estimate when such distributions originated. Numerous dating analyses have recently precipitated a paradigm shift in the general explanations for the phenomenon, away from older geological causes, such as continental drift, in favour of more recent, long-distance dispersal (LDD). For example, the 'Gondwanan vicariance' scenario has been dismissed in various studies of Indian Ocean disjunct distributions. We used the gentian tribe Exaceae to reassess this scenario using molecular dating with minimum (fossil), maximum (geological), secondary (from wider analyses) and hypothesis-driven age constraints. Our results indicate that ancient vicariance cannot be ruled out as an explanation for the early origins of Exaceae across Africa, Madagascar and the Indian subcontinent unless a strong assumption is made about the maximum age of Gentianales. However, both the Gondwanan scenario and the available evidence suggest that there were also several, more recent, intercontinental dispersals during the diversification of the group.
Resumo:
Accurate prediction of mortality following burns is useful as an audit tool, and for providing treatment plan and resource allocation criteria. Common burn formulae (Ryan Score, Abbreviated Burn Severity Index (ABSI), classic and revised Baux) have not been compared with the standard Acute Physiology and Chronic Health Evaluation II (APACHEII) or re-validated in a severely (≥20% total burn surface area) burned population. Furthermore, the revised Baux (R-Baux) has been externally validated thoroughly only once and the pediatric Baux (P-Baux) has yet to be. Using 522 severely burned patients, we show that burn formulae (ABSI, Baux, revised Baux) outperform APACHEII among adults (AUROC increase p<0.001 adults; p>0.5 children). The Ryan Score performs well especially among the most at-risk populations (estimated mortality [90% CI] original versus current study: 33% [26-41%] versus 30.18% [24.25-36.86%] for Ryan Score 2; 87% [78-93%] versus 66.48% [51.31-78.87%] for Ryan Score 3). The R-Baux shows accurate discrimination (AUROC 0.908 [0.869-0.947]) and is well-calibrated. However, the ABSI and P-Baux, although showing high measures of discrimination (AUROC 0.826 [0.737-0.916] and 0.848 [0.758-0.938]) in children), exceedingly overestimates mortality, indicating poor calibration. We highlight challenges in designing and employing scores that are applicable to a wide range of populations.
Resumo:
Le cancer testiculaire, bien que peu fréquent, revêt une importance particulière en oncologie ; il représente actuellement un modèle pour optimiser un suivi radiologique tout en essayant de diminuer l'apparition de tumeurs radio-induites.En effet, cette pathologie présente un taux très élevé de survie nécessitant, au vu du jeune âge des patients, des bilans radiologiques à long terme, auxquels pourront être liés des effets secondaires, en particulier les tumeurs secondaires.Afin de diminuer cela, les recommandations de prise en charge ont évolué et les protocoles de radiologie s'améliorent afin d'exposer à moins de rayonnements ionisants pour un résultat identique.Il est donc devenu primordial de maintenir un suivi optimal tout en essayant d'en minimiser la toxicité. Despite being rare cancers, testicular seminoma and non-seminoma play an important role in oncology: they represent a model on how to optimize radiological follow-up, aiming at a lowest possible radiation exposure and secondary cancer risk. Males diagnosed with testicular cancer undergo frequently prolonged follow-up with CT-scans with potential toxic side effects, in particular secondary cancers. To reduce the risks linked to ionizing radiation, precise follow-up protocols have been developed. The number of recommended CT-scanners has been significantly reduced over the last 10 years. The CT scanners have evolved technically and new acquisition protocols have the potential to reduce the radiation exposure further.
Resumo:
To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30ng/mL and 21ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.
Resumo:
The microbiota plays a pivotal role in the development and calibration of host immunity. Over many millennia, finely balanced interactions between the microbiota and host tissue compartments have evolved, imparting metabolic advantages and protection against pathogens, while restricting deleterious immune responses against innocuous antigens. Perturbations in host-microbiota crosstalk at critical developmental windows in early life may underlie allergy and chronic inflammation. Although the microbiota's of the gut and skin have been extensively characterized, the lung microbiota has also, in recent years, received considerable attention. This ever-expanding field is pushing the boundaries of pulmonary research, with potential implications for novel strategies in the treatment and prevention of chronic lung diseases. In this article, we provide a summary of the development of the microbiota in early life, and describe the evidence from human and murine studies of how microbial dysbiosis in early life can alter the trajectory of immune development and provide the setting for allergic disorders in later life.
Resumo:
To determine the feasibility of data transfer, an interlaboratory comparison was conducted on colon carcinoma cell line (DLD-1) proteins resolved by two-dimensional polyacrylamide gel electrophoresis either on small (6 x 7 cm) or large (16x18 cm) gels. The gels were silver-stained and scanned by laser densitometry, and the image obtained was analyzed using Melanie software. The number of spots detected was 1337+/-161 vs. 2382+/-176 for small vs. large format gels, respectively. After gel calibration using landmarks determined using pl and Mr markers, large- and small-format gels were matched and 712+/-36 proteins were found on both types of gels. Having performed accurate gel matching it was possible to acquire additional information after accessing a 2-D PAGE reference database (http://www.expasy.ch/ cgibin/map2/def?DLD1_HUMAN). Thus, the difference in gel size is not an obstacle for data transfer. This will facilitate exchanges between laboratories or consultation concerning existing databases.
Resumo:
BACKGROUND: Existing prediction models for mortality in chronic obstructive pulmonary disease (COPD) patients have not yet been validated in primary care, which is where the majority of patients receive care. OBJECTIVES: Our aim was to validate the ADO (age, dyspnoea, airflow obstruction) index as a predictor of 2-year mortality in 2 general practice-based COPD cohorts. METHODS: Six hundred and forty-six patients with COPD with GOLD (Global Initiative for Chronic Obstructive Lung Disease) stages I-IV were enrolled by their general practitioners and followed for 2 years. The ADO regression equation was used to predict a 2-year risk of all-cause mortality in each patient and this risk was compared with the observed 2-year mortality. Discrimination and calibration were assessed as well as the strength of association between the 15-point ADO score and the observed 2-year all-cause mortality. RESULTS: Fifty-two (8.1%) patients died during the 2-year follow-up period. Discrimination with the ADO index was excellent with an area under the curve of 0.78 [95% confidence interval (CI) 0.71-0.84]. Overall, the predicted and observed risks matched well and visual inspection revealed no important differences between them across 10 risk classes (p = 0.68). The odds ratio for death per point increase according to the ADO index was 1.50 (95% CI 1.31-1.71). CONCLUSIONS: The ADO index showed excellent prediction properties in an out-of-population validation carried out in COPD patients from primary care settings. © 2014 S. Karger AG, Basel.
Resumo:
In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.
Resumo:
This chapter presents possible uses and examples of Monte Carlo methods for the evaluation of uncertainties in the field of radionuclide metrology. The method is already well documented in GUM supplement 1, but here we present a more restrictive approach, where the quantities of interest calculated by the Monte Carlo method are estimators of the expectation and standard deviation of the measurand, and the Monte Carlo method is used to propagate the uncertainties of the input parameters through the measurement model. This approach is illustrated by an example of the activity calibration of a 103Pd source by liquid scintillation counting and the calculation of a linear regression on experimental data points. An electronic supplement presents some algorithms which may be used to generate random numbers with various statistical distributions, for the implementation of this Monte Carlo calculation method.
Resumo:
The biological uptake of plutonium (Pu) in aquatic ecosystems is of particular concern since it is an alpha-particle emitter with long half-life which can potentially contribute to the exposure of biota and humans. The diffusive gradients in thin films technique is introduced here for in-situ measurements of Pu bioavailability and speciation. A diffusion cell constructed for laboratory experiments with Pu and the newly developed protocol make it possible to simulate the environmental behavior of Pu in model solutions of various chemical compositions. Adjustment of the oxidation states to Pu(IV) and Pu(V) described in this protocol is essential in order to investigate the complex redox chemistry of plutonium in the environment. The calibration of this technique and the results obtained in the laboratory experiments enable to develop a specific DGT device for in-situ Pu measurements in freshwaters. Accelerator-based mass-spectrometry measurements of Pu accumulated by DGTs in a karst spring allowed determining the bioavailability of Pu in a mineral freshwater environment. Application of this protocol for Pu measurements using DGT devices has a large potential to improve our understanding of the speciation and the biological transfer of Pu in aquatic ecosystems.
Resumo:
Pressurized re-entrant (or 4 pi) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields of metrology and nuclear medicine. As a secondary method, these instruments need to be calibrated with appropriate activity standards from primary or direct standardization. The use of these instruments over 50 years has been well described in numerous publications, such as the Monographie BIPM-4 and the special issue of Metrologia on radionuclide metrology (Ratel 2007 Metrologia 44 S7-16, Schrader1997 Activity Measurements With Ionization Chambers (Monographie BIPM-4) Schrader 2007 Metrologia 44 S53-66, Cox et al 2007 Measurement Modelling of the International Reference System (SIR) for Gamma-Emitting Radionuclides (Monographie BIPM-7)). The present work describes the principles of activity measurements, calibrations, and impurity corrections using pressurized ionization chambers in the first part and the uncertainty analysis illustrated with example uncertainty budgets from routine source-calibration as well as from an international reference system (SIR) measurement in the second part.
Resumo:
BACKGROUND: Many publications report the prevalence of chronic kidney disease (CKD) in the general population. Comparisons across studies are hampered as CKD prevalence estimations are influenced by study population characteristics and laboratory methods. METHODS: For this systematic review, two researchers independently searched PubMed, MEDLINE and EMBASE to identify all original research articles that were published between 1 January 2003 and 1 November 2014 reporting the prevalence of CKD in the European adult general population. Data on study methodology and reporting of CKD prevalence results were independently extracted by two researchers. RESULTS: We identified 82 eligible publications and included 48 publications of individual studies for the data extraction. There was considerable variation in population sample selection. The majority of studies did not report the sampling frame used, and the response ranged from 10 to 87%. With regard to the assessment of kidney function, 67% used a Jaffe assay, whereas 13% used the enzymatic assay for creatinine determination. Isotope dilution mass spectrometry calibration was used in 29%. The CKD-EPI (52%) and MDRD (75%) equations were most often used to estimate glomerular filtration rate (GFR). CKD was defined as estimated GFR (eGFR) <60 mL/min/1.73 m(2) in 92% of studies. Urinary markers of CKD were assessed in 60% of the studies. CKD prevalence was reported by sex and age strata in 54 and 50% of the studies, respectively. In publications with a primary objective of reporting CKD prevalence, 39% reported a 95% confidence interval. CONCLUSIONS: The findings from this systematic review showed considerable variation in methods for sampling the general population and assessment of kidney function across studies reporting CKD prevalence. These results are utilized to provide recommendations to help optimize both the design and the reporting of future CKD prevalence studies, which will enhance comparability of study results.