406 resultados para glaucoma surgery
Resumo:
BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.
Resumo:
The purpose of this study was to design microspheres combining sustained delivery and enhanced intracellular penetration for ocular administration of antisense oligonucleotides. Nanosized complexes of antisense TGF-beta2 phosphorothioate oligonucleotides (PS-ODN) with polyethylenimine (PEI), and naked PS-ODN were encapsulated into poly(lactide-co-glycolide) microspheres prepared by the double-emulsion solvent evaporation method. The PS-ODN was introduced either naked or complexed in the inner aqueous phase of the first emulsion. We observed a marked influence of microsphere composition on porosity, size distribution and PS-ODN encapsulation efficiency. Mainly, the presence of PEI induced the formation of large pores observed onto microsphere surface. Introduction of NaCl in the outer aqueous phase increased the encapsulation efficiency and reduced microsphere porosity. In vitro release kinetic of PS-ODN was also investigated. Clearly, the higher the porosity, the faster was the release and the higher was the burst effect. Using an analytical solution of Fick's second law of diffusion, it was shown that the early phase of PS-ODN and PS-ODN-PEI complex release was primarily controlled by pure diffusion, irrespectively of the type of microsphere. Finally, microspheres containing antisense TGF-beta2 nanosized complexes were shown, after subconjunctival administration to rabbit, to significantly increase intracellular penetration of ODN in conjunctival cells and subsequently to improve bleb survival in a rabbit experimental model of filtering surgery. These results open up interesting prospective for the local controlled delivery of genetic material into the eye.
Resumo:
PURPOSE: To evaluate subconjunctival mitomycin C (MMC) injection efficacy and safety in patients with failing glaucoma non-penetrating filtering blebs. METHODS: Twenty-eight eyes were consecutively recruited for this study. Only one eye for each patient was randomly selected. All the recruited patients had glaucoma and uncontrolled intraocular pressure after a non-penetrating filtering glaucoma surgery and/or a pathological aspect of the filtering bleb (i.e., vascularized and/or encysted). One or more MMC injections were performed under the conjunctiva closed to the bleb to improve filtration. Local effects and complications of subconjunctival MMC injections were analyzed. RESULTS: Out of the 28 patients, 21 (75%) had MMC also applied intraoperatively. The mean postoperative IOP before MMC injections was 17 +/- 6.6 mmHg. The final IOP after MMC injections was 13.9 +/- 2.9 mmHg after a mean follow-up of 6 months. A total of 67 subconjunctival MMC injections were performed with a mean of 2.9 (ranging from 1 to 5) injections per patient. The only complication found to be possibly related to MMC injections was two cases of corneal Dellen. CONCLUSION: From these preliminary results, subconjunctival MMC injections in selected cases appear to be not only safe but also effective in promoting further the postoperative IOP drop.
Resumo:
PURPOSE: To evaluate the antimitotic and toxic effects of 5-chlorouracil (5-CU) and 5-fluorouracil (5-FU) and study their potential to delay filtering bleb closure in the rabbit eye when released by poly(ortho esters) (POE). METHODS: Rabbit Tenon fibroblasts and human conjunctival cells were incubated with various 5-CU and 5-FU concentrations. Antiproliferative effects and toxicity were evaluated at 24 and 72 hours by monotetrazolium, neutral red, and Hoechst tests and cell counting. Mechanisms of cell death were evaluated using TUNEL assay, annexin V binding, immunohistochemistry for anti-apoptosis-inducing factor (AIF) and LEI/L-DNase II. Trabeculectomy was performed in pigmented rabbits. Two hundred microliters of POE loaded with 1% wt/wt 5-FU or 5-CU was injected into the subconjunctival space after surgery. Intraocular pressure (IOP) and bleb persistence were monitored for 150 days. RESULTS: In vitro, 5-FU showed a higher antiproliferative effect and a more toxic effect than 5-CU. 5-FU induced cell necrosis, whereas 5-CU induced mostly apoptosis. The apoptosis induced by 5-CU was driven through a non-caspase-dependent pathway involving AIF and LEI/L-DNase II. In vivo, at 34 days after surgery, the mean IOP in the POE/5-CU-treated group was 83% of the baseline level and only 40% in the POE/5-FU-treated group. At 100 days after surgery, IOP was still decreased in the POE/5-CU group when compared with the controls and still inferior to the preoperative value. The mean long-term IOP, with all time points considered, was significantly (P < 0.0001) decreased in the POE/5-CU-treated group (6.0 +/- 2.4 mm Hg) when compared with both control groups, the trabeculectomy alone group (7.6 +/- 2.9 mm Hg), and the POE alone group (7.5 +/- 2.6 mm Hg). Histologic analysis showed evidence of functioning blebs in the POE-5-CU-treated eyes along with a preserved structure of the conjunctiva epithelium. CONCLUSIONS: The slow release of 5-CU from POE has a longstanding effect on the decrease of IOP after glaucoma-filtering surgery in the rabbit eye. Thus, the slow release of POE/5-CU may be beneficial for the prevention of bleb closure in patients who undergo complicated trabeculectomy.
Resumo:
Résumé : Ce travail porte sur l'étude rétrospective d'une série de jeunes patients opérés de glaucomes pédiatriques. Le but est d'évaluer le résultat au long cours d'une intervention chirurgicale combinant une sclérectomie profonde et une trabéculectomie (sclérectomie profonde pénétrante). Durant la période de mars 1997 à octobre 2006, 28 patients on été suivis pour évaluer le résultat de cette chirurgie effectuées sur 35 yeux. Un examen ophtalmologique complet a été pratiqué avant la chirurgie, 1 et 7 jours, puis 1, 2, 3, 4, 6, 9, 12 mois, enfin tous les 6 mois après l'opération. Les critères d'évaluation du résultat postopératoire sont : les changements de pression intraoculaire, le traitement antiglaucomateux adjuvant, le taux de complication, le nombre de reprises chirurgicales,- l'erreur de réfraction, la meilleure acuité visuelle corrigée, l'état et le diamètre de la cornée. L'âge moyen est de 3.6 ± 4.5 ans et le suivi moyen de 3.6 ± 2.9 ans. La pression intraoculaire préopératoire de 31.9 ± 11.5 mmHg baisse de 58.3% (p<0.005) à la fin du suivi. Sur les 14 patients dont l'acuité visuelle a pu être mesurée, 8 (57.1 %) ont une acuité égale ou supérieure à 5/10e, 3 (21.4%) une acuité de 2/10e après intervention. Le taux de succès cumulatif complet à 9 ans est de 52.3%, le succès relatif 70.6%. Les complications menaçant la vision (8.6%) ont été plus fréquentes dans les cas de glaucome réfractaire. Pour conclure la sclérectomie profonde combinée à une trabéculectomie est une technique chirurgicale développée afin de contrôler la pression intraoculaire dans les cas de glaucomes congénitaux, juvéniles et secondaires. Les résultats intermédiaires sont encourageants et prometteurs. Les cas préalablement opérés avant cette nouvelle technique ont cependant un pronostic moins favorable. Le nombre de complications menaçant la vision est essentiellement lié à la sévérité du glaucome et au nombre d'interventions préalables. Abstract : Purpose : To evaluate the outcomes of combined deep sclerectomy and trabeculectomy (penetrating deep sclerectomy) in pediatric glaucoma. Design : Retrospective, non-consecutive, non-comparative, interventional case series. Participants : Children suffering from pediatric glaucoma who underwent surgery between March 1997 and October 2006 were included in this study. Methods : A primary combined deep sclerectomy and trabeculectomy was performed in 35 eyes of 28 patients. Complete examinations were performed before surgery, postoperatively at 1 and 7 days, at 1, 2, 3, 4, 6, 9, 12 months and then every 6 months after surgery. Main Outcome Measures : Surgical outcome was assessed in terms of intraocular pressure (IOP) change, additional glaucoma medication, complication rate, need for surgical revision, as well as refractive errors, best corrected visual acuity (BCVA), and corneal clarity and diameters. Results : The mean age before surgery was 3.6 ± 4.5 years, and the mean follow-up was 3.5 ± 2.9 years. The mean preoperative IOP was 31.9 ± 11.5 mmHg. At the end of follow-up, the mean IOP decreased by 58.3% (p<0.005), and from 14 patients with available BCVA 8 patients (57.1 %) achieved. 0.5 (20/40) or better, 3 (21.4%) 0.2 (20/100), and 2 (14.3%) 0.1 (20/200) in their better eye. The mean refractive error (spherical equivalent) at final follow-up visits was +0.83 ± 5.4. Six patients (43%) were affected by myopia. The complete and qualified success rates, based on a cumulative survival curve, after- 9 years were 52.3% and 70.6%, respectively (p<0.05). Sight threatening complications were more common (8.6%) in refractory glaucomas. Conclusions : Combined deep sclerectomy and trabeculectomy is a surgical technique developed to control IOP in congenital, secondary and juvenile glaucomas. The intermediate results are satisfactory and promising. Previous classic glaucoma surgeries performed before this new technique had less favourable results. The number of sight threatening complications is related to the severity of glaucoma and number of previous surgeries.
Resumo:
PURPOSE: To describe methods and outcomes of excisional revision of a filtering bleb (bleb revision) using free conjunctival autologous graft either for bleb repair or for bleb reduction after trabeculectomy and deep sclerectomy with an implant. METHODS: Retrospective medical records were reviewed for a consecutive non-comparative case series comprising patients who underwent excisional revision of a filtering bleb between May 1998-January 2001. Excisional revision using free conjunctival autologous graft (bleb revision) was performed either for bleb repair, to treat early and late leaks and hypotony with maculopathy, or for bleb reduction, to improve ocular pain, discomfort, burning, foreign body sensation, tearing, and fluctuations of visual acuity. The revision consisted of bleb excision and free conjunctival autologous graft. The bleb histopathology was analyzed in patients who underwent bleb repair. RESULTS: Sixteen patients were included in the study, consisting of nine patients who had a trabeculectomy and seven patients who had a deep sclerectomy with an implant. Bleb revision was necessary in 14 patients due to leaking filtering bleb (bleb repair), and in 2 patients due to bleb dysesthesia (bleb reduction). After a follow-up of 15.1 +/- 8.4 months, the mean intraocular pressure (IOP) rose from 7.8 +/- 6.3 mm Hg to 14.3 +/- 6.5 mm Hg, and the visual acuity from 0.4 +/- 0.3 to 0.7 +/- 0.3, with a P value of 0.008 and 0.03, respectively. The complete success rate at 32 months, according to the Kaplan-Meier survival curve, was 38.3%, and the qualified success rate was 83.3%. Four patients (25%) required additional suturing for persistent bleb leak. To control IOP, antiglaucoma medical therapy was needed for six patients (37.5%) and repeated glaucoma surgery was needed for one patient. CONCLUSION: Free conjunctival autologous graft is a safe and successful procedure for bleb repair and bleb reduction. However, patients should be aware of the postoperative possibility of requiring medical or surgical intervention for IOP control after revision.
Resumo:
Purpose: To compare the efficacy and safety of a slowly resorbable glaucoma implant, Healaflow (HF) and Healon 5 (H5) as spacers injected into failing filtration blebs at the time of bleb needlings, augmented with MMC Methods: Eighty-four glaucoma patients with filtration bleb failure following glaucoma surgery (deep sclerectomy/ trabeculectomy) underwent bleb needling using either HF (n=44) or H5 (n=40) as an intrableb viscoelastic spacer. All needlings were augmented by MMC and performed in the operating room, by a single surgeon. The choice between HF and H5 was randomised. Postoperative data for IOP, number of glaucoma medications (GMs), antimetabolite injections (AMIs), bleb morphology and all complications were recorded at day 1 (D1), weeks 1 (W1), 4 (W4), month 6 (M6) and last visit. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline Results: Age was comparable between groups (HF vs H5; 66 vs 72 years; p=0.13*). There were no differences in mean postoperative IOP or GMs at any time point between groups (mean IOP = HF vs H5; prior to needling=19.8mmHg vs 18.7mmHg, p=0.48*; D1=10.4mmHg vs 10.2mmHg, p=0.85*; W1=12.3mmHg vs 13.8mmHg, p=0.33*; W4=15.7mmHg vs 15.1mmHg, p=0.69*; M6=14.3mmHg vs 13.8mmHg, p=0.69*. Mean GMs= HF vs H5; prior to needling=1.7 vs 1.7, p=0.96*; M6=0.9 vs 1.1, p=0.66*). Success rates were comparable between HF and H5 groups (74% vs 71%). Requirements for AMIs were similar between groups; post filtration surgery and prior to needling (mean AMIs 1.54 vs 1.65 p=0.82*) and within the first six months following needling ( 0.77 vs 0.65 p=0.70*). Complication rates were infrequent in both groups (9%, HF; 3%, H5) * two-sample t-test Conclusions: The early to mid-term success rates of needlings using intrableb spacers were high. However there were no differences observed between the use of crosslinked and high molecular weight sodium hyaluronate
Resumo:
PURPOSE: To evaluate the clinical outcome of patients who received a Baerveldt implant for refractory glaucoma and to identify factors which may influence the outcome. METHODS: Retrospective study including 51 eyes of 51 patients with medically uncontrolled glaucoma who underwent Baerveldt implant surgery between June 1994 and December 1998. Criteria for success were intraocular pressure (IOP) < or = 21 mmHg and > 6 mmHg, necessity of further antiglaucoma medications, absence of additional glaucoma surgery and no loss of light perception. RESULTS: Over a mean follow-up of 37.6 (SD: +/-18.8) months, the mean intraocular pressure decreased from 34.8 (+/-12.5) mmHg to 14.0 (+/-4.3) mmHg at month 60. Qualified success rate, achieved when IOP was below 21 mmHg and higher than 6 mmHg with medications was 25/48 (52%), complete success rate (same IOP limits without medication) was 14/48 (29%). Seven eyes had major complications or lost light perception. Postoperative visual acuity improved or remained within one Snellen line of the preoperative visual acuity in 35 patients (73%). Factors associated with a better prognosis were a preoperative visual acuity better than 20/400 and etiology of glaucoma. CONCLUSION: The Baerveldt implant is effective in lowering intraocular pressure in most patients with refractory glaucoma. Long-term results are promising with satisfactory IOP control.
Resumo:
BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.
Resumo:
The biocompatibility of a viscous, hydrophobic, bioerodible poly(ortho ester) (POE) intended for intraocular application was investigated. POE was evaluated as a blank carrier and as containing modulators of degradation. Each formulation was injected intracamerally and intravitreally in rabbit eyes, and clinical and histological examinations were performed postoperatively for 2 weeks. In the case of intracameral injections, polymer biocompatibility appeared to depend on the amount injected in the anterior chamber. When 50 microL was administered, the polymer degraded within 2 weeks, and clinical observations showed good biocompatibility of POE with no toxicity to the ocular tissues or increase in intraocular pressure. The injection of a larger volume, 100 microL, of POE, appeared inappropriate because of direct contact of polymeric material with the corneal endothelium, and triggered reversible edema and inflammation in the anterior chamber of the eye that regressed after a few days. After intravitreal administration, POE was well tolerated and no inflammatory reaction developed during the observation period. The polymer degraded slowly, appearing as a round whitish bubble in the vitreous cavity. The presence of modulators of degradation both improved POE biocompatibility and prolonged polymer lifetime in the eye. POE appears to be a promising biomaterial for clinical intraocular application.
Resumo:
Purpose: To study the filtering site using ultrasound biomicroscopy. (UBM) after posterior deep sclerectomy with Ex-PRESS? X-50 implant in patients undergoing filtering surgery.¦Methods: Twenty-six patients that participated in this prospective, non comparative study underwent a posterior deep sclerectomy and an Ex- PRESS? X-50 tube implantation. Clinical outcome factors recorded include: intraocular pressure, number of antiglaucoma medications, best corrected visual acuity (BCVA), frequency and types of complications. Six months postoperatively, an ultrasound biomicroscopy examination was performed.¦Results: Mean follow up was 12.0±3.4 months. Mean IOP decreased from 21 ±5.7 mmHg to 12.4±3 mmHg. At last follow-up examination, 65% of eyes had a complete success and 30% a qualified success. The mean number of antiglaucoma medications decreased from 2.5±1.2 preoperatively to 0.7±1 at the last follow-up postoperatively. BCVA was not changed. 27 complications were observed. On the UBM images, the mean intrascleral space volume was 0.25±0.27 mm3 and no relationship was found between volume and intraocular pressure reduction. We noted in 5/26 (19%) eyes a suprachoroïdal hypoechoic. Low-reflective blebs (L-type) were the most common: 15/26 (58%). No correlation between UBM findings and surgical success was evident.¦Conclusions: Deep sclerectomy with Ex-PRESS? X-50 tube implantation seems an efficient glaucoma surgery. It allows satisfactory IOP reduction with a low number of post operative complications. The advantages of deep sclerectomy with collagen implant are maintained with this modified technique. In both, the same reflective types of filtering blebs are present (high, low, encapsulated and flat). The UBM underlines the three mechanisms of aqueous humor resorption previously identified but no correlation with surgical success can be proved.¦-¦Ce travail de thèse est une analyse par ultrasonographic biomicroscopique (UBM) du site de filtration après sclérectomie profonde postérieure modifiée avec implantation d'un tube Ex- PRESS? X-50.¦Vingt six patients atteints d'un glaucome à angle ouvert, ont participé à cette étude prospective et non-comparative. Le critère d'inclusion est un glaucome à angle ouvert non contrôlé malgré un traitement topique maximal.¦Différents types de chirurgie filtrante sont effectués dans la chirurgie du glaucome dont la trabéculectomie et la sclérectomie profonde.¦L'intervention chirurgicale pratiquée dans cette étude consiste en l'implantation d'un tube Ex-PRESS? X-50 de format défini (3 mm de longueur et 50 μπι de diamètre interne) dans la chambre antérieure,au niveau du trabeculum, sous un volet scléral, ce qui permet le drainage de l'humeur aqueuse vers les espaces sous-conjonctivaux, avec diminution de la pression intraoculaire.¦Cette technique implique uniquement une dissection d'un volet scléral superficiel , sans volet scléral profond comme d'une sclérectomie profonde classique.¦Les modes de fonctionnement de cette sclérectomie profonde modifiée sont explorés par UBM, qui donne des images à haute résolution, semblables à des coupes anatomiques. Le volume de l'espace intrascléral créé artificiellement peut en effet être mesuré et mis en corrélation avec la pression intraoculaire et donc avec le taux de succès. Les différents types d'échogénécité de la bulle de filtration sous-conjonctivale provoquée par la dérivation de l'humeur aqueuse sont également observés. La présence éventuelle d'une filtration supplémentaire au niveau choroïdien est aussi détectée.¦De février 2007 à juin 2008, nous avons suivi chez les vingt six yeux des vingt six patients le volume intrascléral, la filtration sous-conjonctivale et la filtration choroïdienne le cas échéant, de même que l'acuité visuelle, la pression intraoculaire, le nombre de traitement antihypertenseur topique et les complications.¦Les résultats démontrent une réduction de 41 % par rapport à la pression intraoculaire préopératoire, ce qui est statistiquement significatif (p<0.0005). En ce qui concerne l'acuité visuelle, les valeurs demeurent stables. Par ailleurs, le nombre de médicaments antiglaucomateux diminue de façon significative de 2.5 ± 1.2 en préopératoire à 0.7 ± 1.0 au dernier examen (p<0.0005). Le volume de l'espace intrascléral, apparaissant toujours en échographie d'aspect fusiforme, n'est pas corrélé de façon significative avec un meilleur succès chirurgical bien que l'on aperçoive une tendance à une corrélation entre un plus grand volume et une pression intraoculaire plus basse.¦La classification la bulle de filtration se fait selon les 4 catégories de bulle de filtration décrites dans la littérature. La répartition révèle une majorité de type L soit hypoéchogène: 15/26 (58%) et une proportion identique, soit, 4/26 (16%), de bulles hyperéchogènes (type H) et encapsulées (type E); les bulles de filtration plates et hyperéchogènes (type F) sont les moins nombreuses 3/26 (11 %).¦La ligne hyporéflective visible dans 19 % des cas entre la sclère et la choroïde représentant potentiellement un drainage suprachoroïdien, n'est pas associée statistiquement à une meilleure filtration et une pression intraoculaire plus basse mais demeure une troisième voie de filtration, en plus de la filtration sous-conjonctivale et intrasclérale.¦En conclusion, cette technique différente, offrant une plus grande sécurité et des résultats satisfaisants sur l'abaissement de la pression intraoculaire, peut être, dans certains cas, une alternative à la sclérectomie profonde classique ,dont elle partage les mécanismes de filtration objectivés par ultrasonographic biomicrioscopique.
Resumo:
ABSTRACT : Background : The aim of this study was to evaluate the midterm biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. Methods : Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. [OP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. Results : For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. Conclusions : The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.
Resumo:
Two cases of a benign form of optic disc edema after successful trabeculectomy are reported. In both patients, optic disc edema was noted 2 to 4 weeks after trabeculectomy. The edema occurred without loss of visual acuity or field. The absolute intraocular pressure and intracranial pressure were normal--that is, the edema was not a syndrome of hypotony or pseudotumor cerebri. However, both patients had intracranial pressure in the high-normal range. The decrease in intraocular pressure into the low normal range after trabeculectomy may have altered the intracranial pressure:intraocular pressure ratio at the lamina cribrosa enough to produce optic disc edema.
Resumo:
PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.