245 resultados para Inter-operator variability


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The site of pharmacological activity of raltegravir is intracellular. Our aim was to determine the extent of raltegravir cellular penetration and whether raltegravir total plasma concentration (C(tot)) predicts cellular concentration (C(cell)). Methods Open-label, prospective, pharmacokinetic study on HIV-infected patients on a stable raltegravir-containing regimen. Plasma and peripheral blood mononuclear cells were simultaneously collected during a 12 h dosing interval after drug intake. C(tot) and C(cell) of raltegravir, darunavir, etravirine, maraviroc and ritonavir were measured by liquid chromatography coupled to tandem mass spectrometry after protein precipitation. Longitudinal mixed effects analysis was applied to the C(cell)/C(tot) ratio. Results Ten HIV-infected patients were included. The geometric mean (GM) raltegravir total plasma maximum concentration (C(max)), minimum concentration (C(min)) and area under the time-concentration curve from 0-12 h (AUC(0-12)) were 1068 ng/mL, 51.1 ng/mL and 4171 ng·h/mL, respectively. GM raltegravir cellular C(max), C(min) and AUC(0-12) were 27.5 ng/mL, 2.9 ng/mL and 165 ng·h/mL, respectively. Raltegravir C(cell) corresponded to 5.3% of C(tot) measured simultaneously. Both concentrations fluctuate in parallel, with C(cell)/C(tot) ratios remaining fairly constant for each patient without a significant time-related trend over the dosing interval. The AUC(cell)/AUC(tot) GM ratios for raltegravir, darunavir and etravirine were 0.039, 0.14 and 1.55, respectively. Conclusions Raltegravir C(cell) correlated with C(tot) (r = 0.86). Raltegravir penetration into cells is low overall (∼5% of plasma levels), with distinct raltegravir cellular penetration varying by as much as 15-fold between patients. The importance of this finding in the context of development of resistance to integrase inhibitors needs to be further investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether the need for retreatment after an initial phase of 3 monthly intravitreal injections of ranibizumab shows an intra-individual regular rhythm and to what degree it varies between different patients. Methods: Prospective study with 42 patients with exudative AMD, treatment naïve. Loading dose of 3 monthly doses of ranibizumab (0,5 mg), followed by a 12 months pro re nata (PRN) regimen according to early exudative signs on HD-OCT Cirrus, Zeiss. The follow-up visits were intensified (week 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, etc after each injection) in order to detect recurrences early, and injection followed within 3 days in cases of subretinal fluid, cysts, or central thickness increase of>50microns. Intervals were calculated between injections for the 12 month follow-up with PRN treatment. Variability was expressed as standard deviation (SD). Results: Visual acuity (VA) improved from a mean ETDRS score of 61.6 (SD 10.8) at baseline to 68.0 (SD 10.2) at month 3 and to 74.7(SD 9.0) at month 12. The 15 patients who have already completed the study showed maintenance of the VA improvement. Central foveal thickness improved from a mean value of 366 microns (baseline) to 253 microns (month 3), well maintained thereafter. Mean number of injections was 8.8 (SD 3.5,range 0-12) per 12 months of follow-up (after 3 doses), with mean individual treatment-recurrence (TR) intervals ranging from 28->365 days (mean 58). Intraindividual variability of TR intervals (SD) was 7.1 days as a mean value (range 1.7¡V22.6). It ranged within 20% of the mean intra-individual interval for 30 (91%) and within 15% for 21 patients (64%). The first interval was within 1 week of the mean intra-individual interval in 64% and within 2 weeks in 89% of patients. Conclusions: The majority of AMD patients showed a relatively stable rhythm for PRN injections of ranibizumab after initial loading phase, associated with excellent functional/anatomical results. The initial interval last loading dose-first recurrence may have a predictive value for further need of treatment, potentially facilitating follow-up and patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE:To determine whether the need for retreatment after an initial loading phase of 3 monthly intravitreal injections of ranibizumab shows an intra-individual regular rhythm and to what degree it varies between different patients.SETTING:Prospective mono-centre cohort study.METHODS:Prospective study with 42 patients with exudative age-related macular degeneration (AMD), treatment na?ve, giving informed consent. Loading dose of 3 monthly doses of ranibizumab (0,5mg), followed by a 12 months pro re nata (PRN) regimen according to early exudative signs on spectral domain optical coherence tomography (HD-OCT Cirrus Zeiss?, cube 512x126). The follow-up visits were intensified (week 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, 24, etc after each injection) in order to detect exudative recurrences early, and injection followed within 3 days in cases of subretinal fluid, or intraretinal cysts, or central thickness increase of >50?m. Intervals were calculated between injections and the following recurrence was calculated for the 12 month follow-up with PRN treatment. Variability was expressed as standard deviation (SD). RESULTS Visual acuity (VA) improved from a mean ETDRS letter score of 61.6 (SD 10.8) at baseline to 68.0 (SD 10.2, +6.4 letters) at month 3 and increased further to 74.7 (SD 9.0, +13.1 letters from baseline) at month 12. The 15 patients who have completed the study by October 2010 showed maintenance of the VA improvement. Retinal thickness of the central foveal subfield improved from a mean value of 366?m(baseline) to 253?m(month 3), well maintained thereafter. Mean number of injections was 8.8 (SD 3.5) per 12 months of follow-up (after 3 loading doses), ranging from 0 to 12, with mean individual treatment-recurrence intervals ranging from 28 to >365 days (mean 58 days). Intraindividual variability of treatment-recurrence intervals, measured as SD of the individual intervals, was 7.1days as a mean value(range 1.7 ? 22.6 days) for the 33 patients with more than 1 injection during follow-up. SD was higher for longer intervals of an individual patient. It ranged within 20% of the mean intra-individual interval for 30 patients(91%) and within 15% for 21 patients(64%). The first interval was within 1 week of the mean intra-individual interval in 64% of patients and within 2 weeks in 89% of patients.CONCLUSIONS:The majority of AMD patients showed a relatively stable rhythm for PRN injections of intravitreal ranibizumab after initial loading phase, associated with excellent functional and anatomical results. The initial interval between last loading dose and first recurrence may have a predictive value for further need of treatment, therefore potentially facilitating follow-up and patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Front crawl is an alternating swimming stroke technique in which different phases of arm movement induce changes in acceleration of limbs and body. This study proposes a new approach to use inertial body worn sensors to estimate main temporal phases of front crawl. Distinctive features in kinematic signals are used to detect the temporal phases. These temporal phases are key information sources of qualitative and quantitative evaluation of swimming coordination, which have been assessed previously by video analysis. The present method has been evaluated upon a wide range of coordination and showed a difference of 4.9% with video based system. The results are in line with video analysis inter-operator variability yet offering an easy-to-use system for trainers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is established that the ratio between step length (SL) and step frequency (SF) is constant over a large range of walking speed. However, few data are available about the spontaneous variability of this ratio during unconstrained outdoor walking, in particular over a sufficient number of steps. The purpose of the present study was to assess the inter- and intra-subject variability of spatio-temporal gait characteristics [SL, SF and walk ratio (WR=SL/SF)] while walking at different freely selected speeds. Twelve healthy subjects walked three times along a 100-m athletic track at: (1). a slower than preferred speed, (2). preferred speed and (3). a faster than preferred speed. Two professional GPS receivers providing 3D positions assessed the walking speed and SF with high precision (less than 0.5% error). Intra-subject variability was calculated as the variation among eight consecutive 5-s samples. WR was found to be constant at preferred and fast speeds [0.41 (0.04) m.s and 0.41 (0.05) m.s respectively] but was higher at slow speeds [0.44 (0.05) m.s]. In other words, between slow and preferred speed, the speed increase was mediated more by a change in SF than SL. The intra-subject variability of WR was low under preferred [CV, coefficient of variation = 1.9 (0.6)%] and fast [CV=1.8 (0.5)%] speed conditions, but higher under low speed condition [CV=4.1 (1.5)%]. On the other hand, the inter-subject variability of WR was 11%, 10% and 12% at slow, preferred and fast walking speeds respectively. It is concluded that the GPS method is able to capture basic gait parameters over a short period of time (5 s). A specific gait pattern for slow walking was observed. Furthermore, it seems that the walking patterns in free-living conditions exhibit low intra-individual variability, but that there is substantial variability between subjects.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Imatinib (Glivec®) has transformed the treatment and short-term prognosis of chronic myeloid leukemia (CML) and gastrointestinal stromal tumor (GIST). However, the treatment must be taken indefinitely, it is not devoid of inconvenience and toxicity. Moreover, resistance or escape from disease control occurs in a significant number of patients. Imatinib is a substrate of the cytochromes P450 CYP3A4/5 and of the multidrug transporter P-glycoprotein (product of the MDR1 gene). Considering the large inter-individual differences in the expression and function of those systems, the disposition and clinical activity of imatinib can be expected to vary widely among patients, calling for dosage individualization. The aim of this exploratory study was to determine the average pharmacokinetic parameters characterizing the disposition of imatinib in the target population, to assess their inter-individual variability, and to identify influential factors affecting them. A total of 321 plasma concentrations, taken at various sampling times after the latest dose, were measured in 59 patients receiving Glivec at diverse regimens, using a validated HPLC-UV method developed for this study. The results were analyzed by non-linear mixed effect modeling (NONMEM). A one-compartment model with first-order absorption appeared appropriate to describe the data, with an average apparent clearance of 12.4 l/h, a distribution volume of 268 l and an absorption constant of 0.47 h-1. The clearance was affected by body weight, age and sex. No influences of interacting drugs were found. DNA samples were used for pharmacogenetic explorations. At present, only the MDR1 polymorphism has been assessed and seems to affect the pharmacokinetic parameters of imatinib. Large inter-individual variability remained unexplained by the demographic covariates considered, both on clearance (40 %) and distribution volume (71 %). Together with intra-patient variability (34 %), this translates into an 8-fold width of the 90 %-prediction interval of plasma concentrations expected under a fixed dosing regimen. This is a strong argument to further investigate the possible usefulness of a therapeutic drug monitoring program for imatinib. It may help to individualize the dosing regimen before overt disease progression or observation of treatment toxicity, thus improving both the long-term therapeutic effectiveness and tolerability of this drug.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To assess the inter/intraobserver variability of apparent diffusion coefficient (ADC) measurements in treated hepatic lesions and to compare ADC measurements in the whole lesion and in the area with the most restricted diffusion (MRDA). MATERIALS AND METHODS: Twenty-five patients with treated malignant liver lesions were examined on a 3.0T machine. After agreeing on the best ADC image, two readers independently measured the ADC values in the whole lesion and in the MRDA. These measurements were repeated 1 month later. The Bland-Altman method, Spearman correlation coefficients, and the Wilcoxon signed-rank test were used to evaluate the measurements. RESULTS: Interobserver variability for ADC measurements in the whole lesion and in the MRDA was 0.17 x 10(-3) mm(2)/s [-0.17, +0.17] and 0.43 x 10(-3) mm(2)/s [-0.45, +0.41], respectively. Intraobserver limits of agreement could be as low as [-0.10, +0.12] 10(-3) mm(2)/s and [-0.20, +0.33] 10(-3) mm(2)/s for measurements in the whole lesion and in the MRDA, respectively. CONCLUSION: A limited variability in ADC measurements does exist, and it should be considered when interpreting ADC values of hepatic malignancies. This is especially true for the measurements of the minimal ADC.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Imatinib has revolutionized the treatment of chronic myeloid leukemia (CML) and gastrointestinal stromal tumors (GIST). Considering the large inter-individual differences in the function of the systems involved in its disposition, exposure to imatinib can be expected to vary widely among patients. This observational study aimed at describing imatinib pharmacokinetic variability and its relationship with various biological covariates, especially plasma alpha1-acid glycoprotein (AGP), and at exploring the concentration-response relationship in patients. Methods: A population pharmacokinetic model (NONMEM) including 321 plasma samples from 59 patients was built up and used to derive individual post-hoc Bayesian estimates of drug exposure (AUC; area under curve). Associations between AUC and therapeutic response or tolerability were explored by ordered logistic regression. Influence of the target genotype (i.e. KIT mutation profile) on response was also assessed in GIST patients. Results: A one-compartment model with first-order absorption appropriately described the data, with an average oral clearance of 14.3 L/h (CL) and volume of distribution of 347 L (Vd). A large inter-individual variability remained unexplained, both on CL (36%) and Vd (63%), but AGP levels proved to have a marked impact on total imatinib disposition. Moreover, both total and free AUC correlated with the occurrence and number of side effects (e.g. OR 2.9±0.6 for a 2-fold free AUC increase; p<0.001). Furthermore, in GIST patients, higher free AUC predicted a higher probability of therapeutic response (OR 1.9±0.5; p<0.05), notably in patients with tumor harboring an exon 9 mutation or wild-type KIT, known to decrease tumor sensitivity towards imatinib. Conclusion: The large pharmacokinetic variability, associated to the pharmacokinetic-pharmacodynamic relationship uncovered are arguments to further investigate the usefulness of individualizing imatinib prescription based on TDM. For this type of drug, it should ideally take into consideration either circulating AGP concentrations or free drug levels, as well as KIT genotype for GIST.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The increase of apparent diffusion coefficient (ADC) in treated hepatic malignancies compared to pre-therapeutic values has been interpreted as treatment success; however, the variability of ADC measurements remains unknown. Furthermore, ADC has been usually measured in the whole lesion, while measurements should be probably centered on the area with the most restricted diffusion (MRDA) as it represents potential tumoral residue. Our objective was to compare the inter/intraobserver variability of ADC measurements in the whole lesion and in MRDA. Material and methods: Forty patients previously treated with chemoembolization or radiofrequency were evaluated (20 on 1.5T and 20 on 3.0T). After consensual agreement on the best ADC image, two readers measured the ADC values using separate regions of interest that included the whole lesion and the whole MRDA without exceeding their borders. The same measurements were repeated two weeks later. Spearman test and the Bland-Altman method were used. Results: Interobserver correlation in ADC measurements in the whole lesion and MRDA was as follows: 0.962 and 0.884. Intraobserver correlation was, respectively, 0.992 and 0.979. Interobserver limits of variability (mm2/sec*10-3) were between -0.25/+0.28 in the whole lesion and between -0.51/+0.46 in MRDA. Intraobserver limits of variability were, respectively: -0.25/+0.24 and -0.43/+0.47. Conclusion: We observed a good inter/intraobserver correlation in ADC measurements. Nevertheless, a limited variability does exist, and it should be considered when interpreting ADC values of hepatic malignancies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: (1) To quantify wear of two different denture tooth materials in vivo with two study designs, (2) to relate tooth variables to vertical loss. METHODS: Two different denture tooth materials had been used (experimental material=test; DCL=control). In study 1 (split-mouth, 6 test centers) 60 subjects received complete dentures, in study 2 (two-arm, 1 test center) 29 subjects. In study 1 the mandibular dentures were supported by implants in 33% of the subjects, in study 2 only in 3% of the subjects. Impressions of the dentures were taken and poured with improved stone at baseline and after 6, 12, 18 and 24 months. Each operator evaluated the wear subjectively. Wear analysis was carried out with a laser scanning device. Maximal vertical loss of the attrition zones was calculated for each tooth cusp and tooth. A mixed linear model was used to statistically analyse the logarithmically transformed wear data. RESULTS: Due to drop-outs and unmatchable casts, only 47 subjects of study 1 and 14 of study 2 completed the 2-year recall. Overall, 75% of all teeth present could be analysed. There was no statistically difference in the overall wear between the test and control material for either study 1 or study 2. The relative increase in wear over time was similar in both study designs. However, a strong subject effect and center effect were observed. The fixed factors included in the model (time, tooth, center, etc.) accounted for 43% of the variability, whereas the random subject effect accounted for another 30% of the variability, leaving about 28% of unexplained variability. More wear was consistently recorded in the maxillary teeth compared to the mandibular teeth and in the first molar teeth compared to the premolar teeth and the second molars. Likewise, the supporting cusps showed more wear than the non-supporting cusps. The amount of wear did not depend on whether or not the lower dentures were supported by implants. The subjective wear was correct in about 67% of the cases if it is postulated that a wear difference of 100μm should be subjectively detectable. SIGNIFICANCE: The clinical wear of denture teeth is highly variable with a strong patient effect. More wear can be expected in maxillary denture teeth compared to mandibular teeth, first molars compared to premolars and supported cusps compared to non-supported cusps. Laboratory data on the wear of denture tooth materials may not be confirmed in well-structured clinical trials probably due to the large inter-individual variability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Non-invasive brain imaging techniques often contrast experimental conditions across a cohort of participants, obfuscating distinctions in individual performance and brain mechanisms that are better characterised by the inter-trial variability. To overcome such limitations, we developed topographic analysis methods for single-trial EEG data [1]. So far this was typically based on time-frequency analysis of single-electrode data or single independent components. The method's efficacy is demonstrated for event-related responses to environmental sounds, hitherto studied at an average event-related potential (ERP) level. Methods: Nine healthy subjects participated to the experiment. Auditory meaningful sounds of common objects were used for a target detection task [2]. On each block, subjects were asked to discriminate target sounds, which were living or man-made auditory objects. Continuous 64-channel EEG was acquired during the task. Two datasets were considered for each subject including single-trial of the two conditions, living and man-made. The analysis comprised two steps. In the first part, a mixture of Gaussians analysis [3] provided representative topographies for each subject. In the second step, conditional probabilities for each Gaussian provided statistical inference on the structure of these topographies across trials, time, and experimental conditions. Similar analysis was conducted at group-level. Results: Results show that the occurrence of each map is structured in time and consistent across trials both at the single-subject and at group level. Conducting separate analyses of ERPs at single-subject and group levels, we could quantify the consistency of identified topographies and their time course of activation within and across participants as well as experimental conditions. A general agreement was found with previous analysis at average ERP level. Conclusions: This novel approach to single-trial analysis promises to have impact on several domains. In clinical research, it gives the possibility to statistically evaluate single-subject data, an essential tool for analysing patients with specific deficits and impairments and their deviation from normative standards. In cognitive neuroscience, it provides a novel tool for understanding behaviour and brain activity interdependencies at both single-subject and at group levels. In basic neurophysiology, it provides a new representation of ERPs and promises to cast light on the mechanisms of its generation and inter-individual variability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CYP3A4, CYP3A5 and CYP3A7 are hepatic enzymes that metabolize about 50% of drugs on the market, with a large overlap in their specificities. We investigated the genetic bases that contribute to the variation of CYP3A activity. We phenotyped 251 individuals from two independent studies (182 patients treated with methadone and 69 patients with clozapine) for CYP3A activity using the midazolam phenotyping test and genotyped them for CYP3A4, CYP3A5, and CYP3A7 genetic variants, including the single nucleotide polymorphism (SNP) rs4646437C>T in intron 7 of CYP3A4. Owing to the fact that CYP enzymes require electron transfer through the P450 oxidoreductase (POR), and functional impairment has been shown for the POR*28 SNP, this polymorphism was also analysed. We show that CYP3A4, CYP3A5 and CYP3A7 genotypes, including the SNP rs4646437C>T, do not reflect the inter-individual variability of CYP3A activity (P>0.1). In contrast, POR*28 TT genotype presents a 1.6-fold increase in CYP3A activity compared with POR*28C carriers (n = 182, P = 0.004). This finding was replicated in the second independent dataset (n = 69, P = 0.04). The SNP POR*28 seems to be a better genetic marker of the variability of total CYP3A activity in vivo than CYP3A4, CYP3A5 and CYP3A7 genetic variants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les progrès de la thérapie antirétrovirale ont transformé l'infection par le VIH d'une condition inévitablement fatale à une maladie chronique. En dépit de ce succès, l'échec thérapeutique et la toxicité médicamenteuse restent fréquents. Une réponse inadéquate au traitement est clairement multifactorielle et une individualisation de la posologie des médicaments qui se baserait sur les facteurs démographiques et génétiques des patients et sur les taux sanguins totaux, libres et/ou cellulaires des médicaments pourrait améliorer à la fois l'efficacité et la tolérance de la thérapie, cette dernière étant certainement un enjeu majeur pour un traitement qui se prend à vie.L'objectif global de cette thèse était de mieux comprendre les facteurs pharmacocinétiques (PK) et pharmacogénétiques (PG) influençant l'exposition aux médicaments antirétroviraux (ARVs) nous offrant ainsi une base rationnelle pour l'optimisation du traitement antiviral et pour l'ajustement posologique des médicaments chez les patients VIH-positifs. Une thérapie antirétrovirale adaptée au patient est susceptible d'augmenter la probabilité d'efficacité et de tolérance à ce traitement, permettant ainsi une meilleure compliance à long terme, et réduisant le risque d'émergence de résistance et d'échec thérapeutique.A cet effet, des méthodes de quantification des concentrations plasmatiques totales, libres et cellulaires des ARVs ainsi que de certains de leurs métabolites ont été développées et validées en utilisant la chromatographie liquide coupée à la spectrométrie de masse en tandem. Ces méthodes ont été appliquées pour la surveillance des taux d'ARVs dans diverses populations de patients HIV-positifs. Une étude clinique a été initiée dans le cadre de l'étude VIH Suisse de cohorte mère-enfant afin de déterminer si la grossesse influence la cinétique des ARVs. Les concentrations totales et libres du lopînavir, de l'atazanavir et de la névirapine ont été déterminées chez les femmes enceintes suivies pendant leur grossesse, et celles-ci ont été trouvées non influencées de manière cliniquement significative par la grossesse. Un ajustement posologique de ces ARVs n'est donc pas nécessaire chez les femmes enceintes. Lors d'une petite étude chez des patients HIV- positifs expérimentés, la corrélation entre l'exposition cellulaire et plasmatique des nouveaux ARVs, notamment le raltégravir, a été déterminée. Une bonne corrélation a été obtenue entre taux plasmatiques et cellulaires de raltégravir, suggérant que la surveillance des taux totaux est un substitut satisfaisant. Cependant, une importante variabilité inter¬patient a été observée dans les ratios d'accumulation cellulaire du raltégravir, ce qui devrait encourager des investigations supplémentaires chez les patients en échec sous ce traitement. L'efficacité du suivi thérapeutique des médicaments (TDM) pour l'adaptation des taux d'efavirenz chez des patients avec des concentrations au-dessus de la cible thérapeutique recommandée a été évaluée lors d'une étude prospective. L'adaptation des doses d'efavirenz basée sur le TDM s'est montrée efficace et sûre, soutenant l'utilisation du TDM chez les patients avec concentrations hors cible thérapeutique. L'impact des polymorphismes génétiques des cytochromes P450 (CYP) 2B6, 2A6 et 3A4/5 sur la pharmacocinétique de l'efavirenz et de ces métabolites a été étudié : un modèle de PK de population intégrant les covariats génétiques et démographiques a été construit. Les variations génétiques fonctionnelles dans les voies de métabolisation principales (CYP2B6) et accessoires {CYP2A6et 3A4/S) de l'efavirenz ont un impact sur sa disposition, et peuvent mener à des expositions extrêmes au médicament. Un? ajustement des doses guidé par le TDM est donc recommandé chez ces patients, en accord avec les polymorphismes génétiques.Ainsi, nous avons démonté qu'en utilisant une approche globale tenant compte à la fois des facteurs PK et PG influençant l'exposition aux ARVs chez les patients infectés, il est possible, si nécessaire, d'individualiser la thérapie antirétrovirale dans des situations diverses. L'optimisation du traitement antirétroviral contribue vraisemblablement à une meilleure efficacité thérapeutique à iong terme tout en réduisant la survenue d'effets indésirables.Résumé grand publicOptimisation de la thérapie antirétrovirale: approches pharmacocinétiques et pharmacogénétiquesLes progrès effectués dans le traitement de l'infection par le virus de llmmunodéficienoe humaine acquise (VIH) ont permis de transformer une affection mortelle en une maladie chronique traitable avec des médicaments de plus en plus efficaces. Malgré ce succès, un certain nombre de patients ne répondent pas de façon optimale à leur traitement etyou souffrent d'effets indésirables médicamenteux entraînant de fréquentes modifications dans leur thérapie. Il a été possible de mettre en évidence que l'efficacité d'un traitement antirétroviral est dans la plupart des cas corrélée aux concentrations de médicaments mesurées dans le sang des patients. Cependant, le virus se réplique dans la cellule, et seule la fraction des médicaments non liée aux protéines du plasma sanguin peut entrer dans la cellule et exercer l'activité antirétrovirale au niveau cellulaire. Il existe par ailleurs une importante variabilité des concentrations sanguines de médicament chez des patients prenant pourtant la même dose de médicament. Cette variabilité peut être due à des facteurs démographiques et/ou génétiques susceptibles d'influencer la réponse au traitement antirétroviral.Cette thèse a eu pour objectif de mieux comprendre les facteurs pharmacologiques et génétiques influençant l'efficacité et ta toxicité des médicaments antirétroviraux, dans le but d'individualiser la thérapie antivirale et d'améliorer le suivi des patients HIV-positifs.A cet effet, des méthodes de dosage très sensibles ont été développées pour permettre la quantification des médicaments antirétroviraux dans le sang et les cellules. Ces méthodes analytiques ont été appliquées dans le cadre de diverses études cliniques réalisées avec des patients. Une des études cliniques a recherché s'il y avait un impact des changements physiologiques liés à la grossesse sur les concentrations des médicaments antirétroviraux. Nous avons ainsi pu démontrer que la grossesse n'influençait pas de façon cliniquement significative le devenir des médicaments antirétroviraux chez les femmes enceintes HIV- positives. La posologie de médicaments ne devrait donc pas être modifiée dans cette population de patientes. Par ailleurs, d'autres études ont portés sur les variations génétiques des patients influençant l'activité enzymatique des protéines impliquées dans le métabolisme des médicaments antirétroviraux. Nous avons également étudié l'utilité d'une surveillance des concentrations de médicament (suivi thérapeutique) dans le sang des patients pour l'individualisation des traitements antiviraux. Il a été possible de mettre en évidence des relations significatives entre l'exposition aux médicaments antirétroviraux et l'existence chez les patients de certaines variations génétiques. Nos analyses ont également permis d'étudier les relations entre les concentrations dans le sang des patients et les taux mesurés dans les cellules où le virus HIV se réplique. De plus, la mesure des taux sanguins de médicaments antirétroviraux et leur interprétation a permis d'ajuster la posologie de médicaments chez les patients de façon efficace et sûre.Ainsi, la complémentarité des connaissances pharmacologiques, génétiques et virales s'inscrit dans l'optique d'une stratégie globale de prise en charge du patient et vise à l'individualisation de la thérapie antirétrovirale en fonction des caractéristiques propres de chaque individu. Cette approche contribue ainsi à l'optimisation du traitement antirétroviral dans la perspective d'un succès du traitement à long terme tout en réduisant la probabilité des effets indésirables rencontrés. - The improvement in antirétroviral therapy has transformed HIV infection from an inevitably fatal condition to a chronic, manageable disease. However, treatment failure and drug toxicity are frequent. Inadequate response to treatment is clearly multifactorial and, therefore, dosage individualisation based on demographic factors, genetic markers and measurement of total, free and/or cellular drug level may increase both drug efficacy and tolerability. Drug tolerability is certainly a major issue for a treatment that must be taken indefinitely.The global objective of this thesis aimed at increasing our current understanding of pharmacokinetic (PK) and pharmacogenetic (PG) factors influencing the exposition to antirétroviral drugs (ARVs) in HIV-positive patients. In turn, this should provide us with a rational basis for antiviral treatment optimisation and drug dosage adjustment in HIV- positive patients. Patient's tailored antirétroviral regimen is likely to enhance treatment effectiveness and tolerability, enabling a better compliance over time, and hence reducing the probability of emergence of viral resistance and treatment failure.To that endeavour, analytical methods for the measurement of total plasma, free and cellular concentrations of ARVs and some of their metabolites have been developed and validated using liquid chromatography coupled with tandem mass spectrometry. These assays have been applied for the monitoring of ARVs levels in various populations of HIV- positive patients. A clinical study has been initiated within the frame of the Mother and Child Swiss HIV Cohort Study to determine whether pregnancy influences the exposition to ARVs. Free and total plasma concentrations of lopinavir, atazanavir and nevirapine have been determined in pregnant women followed during the course of pregnancy, and were found not influenced to a clinically significant extent by pregnancy. Dosage adjustment for these drugs is therefore not required in pregnant women. In a study in treatment- experienced HIV-positive patients, the correlation between cellular and total plasma exposure to new antirétroviral drugs, notably the HIV integrase inhibitor raltegravir, has been determined. A good correlation was obtained between total and cellular levels of raltegravir, suggesting that monitoring of total levels are a satisfactory. However, significant inter-patient variability was observed in raltegravir cell accumulation which should prompt further investigations in patients failing under an integrase inhibitor-based regimen. The effectiveness of therapeutic drug monitoring (TDM) to guide efavirenz dose reduction in patients having concentrations above the recommended therapeutic range was evaluated in a prospective study. TDM-guided dosage adjustment of efavirenz was found feasible and safe, supporting the use of TDM in patients with efavirenz concentrations above therapeutic target. The impact of genetic polymorphisms of cytochromes P450 (CYP) 2B6, 2A6 and 3A4/5 on the PK of efavirenz and its metabolites was studied: a population PK model was built integrating both genetic and demographic covariates. Functional genetic variations in main (CYP2B6) and accessory (2A6, 3A4/5) metabolic pathways of efavirenz have an impact on efavirenz disposition, and may lead to extreme drug exposures. Dosage adjustment guided by TDM is thus required in those patients, according to the pharmacogenetic polymorphism.Thus, we have demonstrated, using a comprehensive approach taking into account both PK and PG factors influencing ARVs exposure in HIV-infected patients, the feasibility of individualising antirétroviral therapy in various situations. Antiviral treatment optimisation is likely to increase long-term treatment success while reducing the occurrence of adverse drug reactions.