59 resultados para Height Velocity
Resumo:
OBJECTIVES: Growth retardation is a frequent complication of paediatric inflammatory bowel disease (IBD). Only a few studies report the final height of these patients, with controversial results. We compared adult height of patients with paediatric IBD with that of patients with adult-onset disease. METHODS: Height data of 675 women 19-44 years of age and 454 men 23-44 years of age obtained at inclusion in the Swiss IBD cohort study registry were grouped according to the age at diagnosis: (a) prepubertal (men≤13, women≤11 years), (b) pubertal (men 13-22, women 11-18 years) and (c) adult (men>22, women>18 years of age), and compared with each other and with healthy controls. RESULTS: Male patients with prepubertal onset of Crohn's disease (CD) had significantly lower final height (mean 172±6 cm, range 161-182) compared with men with pubertal (179±6 cm, 161-192) or adult (178±7 cm, 162-200) age at onset and the general population (178±7 cm, 142-204). Height z-scores standardized against heights of the normal population were significantly lower in all patients with a prepubertal diagnosis of CD (-0.8±0.9) compared with the other patient groups (-0.1±0.8, P<0.001). Prepubertal onset of CD emerged as a risk factor for reduced final height in patients with prepubertal CD. No difference for final height was found between patients with ulcerative or unclassified IBD diagnosed at prepubertal, pubertal or adult age. CONCLUSION: Prepubertal onset of CD is a risk for lower final height, independent of the initial disease location and the necessity for surgical interventions.
Resumo:
OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).
Resumo:
BACKGROUND: Pulse wave velocity (PWV), an index of arterial wall stiffness, is modulated by blood pressure (BP). Whether heart rate (HR) is also a modulator of PWV is controversial. Recent research involving mainly patients with high aortic PWV have found either no change or a positive correlation between the two. Given that PWV is increasingly being measured in cardiovascular studies, the relationship between HR and PWV should be known in patients with preserved arterial wall elasticity. OBJECTIVE: The aim of this study was to evaluate the importance of HR as a determinant of the variability in PWV in patients with a low degree of atherosclerosis. DESIGN AND METHODS: Fourteen patients (five female, nine male; aged 68 +/- 8 years) were evaluated post pacemaker implantation due to sick sinus or carotid hypersensitivity syndromes. Carotid-femoral PWV was measured at rest and during atrial pacing at 80, 90 and 100 bpm (paced HR). Arterial femoral blood flow (AFBF) was measured by echodoppler. RESULTS: PWV increased from 6.2 +/- 1.5 m/s (mean +/- SD) during resting sinus rhythm (HR 62 +/- 8 bpm; mean +/- SD) to 6.8 +/- 1.0, 7.0 +/- 0.9, and 7.6 +/- 1.1 m/s at pacing rates of 80, 90 and 100 bpm, respectively (P < 0.0001). Systolic (SBP) and mean blood pressure (MBP) remained constant at all HR levels, whereas AFBF increased in a linear fashion. CONCLUSIONS: These results demonstrate that even in patients with a low degree of atherosclerosis, HR is a potential modulator of carotid-femoral PWV.
Resumo:
We compared cerebral blood flow velocity during anesthesia with sevoflurane and halothane in 23 children admitted for elective surgery (age, 0.4-9.7 yr; median age, 1.9 yr; ASA physical status I-II). Inhaled induction was performed in a randomized sequence with sevoflurane or halothane. Under steady-state conditions, cerebral blood flow velocity (systolic [V(s)], mean [V(mn)], and diastolic [VD]) were measured by a blinded investigator using transcranial pulsed Doppler ultrasonography. The anesthetic was then changed. CBFV measurements were repeated after washout of the first anesthetic and after steady-state of the second (equivalent minimal alveolar concentration to first anesthetic). The resistance index was calculated. VD and V(mn) were significantly lower during sevoflurane (V(mn) 1.35 m/s) than during halothane (V(mn) 1.50 m/s; P = 0.001), whereas V(s) was unchanged. The resistance index was lower during halothane (P < 0.001). Our results indicate lower vessel resistance and higher mean velocity during halothane than during sevoflurane. IMPLICATIONS: The mean cerebral blood flow velocity is significantly decreased in children during inhaled anesthesia with sevoflurane than during halothane. This might be relevant for the choice of anesthetic in children with risk of increased intracranial pressure, neurosurgery, or craniofacial osteotomies.
Resumo:
Adult height is a model polygenic trait, but there has been limited success in identifying the genes underlying its normal variation. To identify genetic variants influencing adult human height, we used genome-wide association data from 13,665 individuals and genotyped 39 variants in an additional 16,482 samples. We identified 20 variants associated with adult height (P < 5 x 10(-7), with 10 reaching P < 1 x 10(-10)). Combined, the 20 SNPs explain approximately 3% of height variation, with a approximately 5 cm difference between the 6.2% of people with 17 or fewer 'tall' alleles compared to the 5.5% with 27 or more 'tall' alleles. The loci we identified implicate genes in Hedgehog signaling (IHH, HHIP, PTCH1), extracellular matrix (EFEMP1, ADAMTSL3, ACAN) and cancer (CDK6, HMGA2, DLEU7) pathways, and provide new insights into human growth and developmental processes. Finally, our results provide insights into the genetic architecture of a classic quantitative trait.
Resumo:
Background: Few data is available on long-term secular trends in height and weight in children in countries in transition. We assessed the secular trends in height and weight among representative samples of children and adolescents from the Seychelles (African region). Methods: Weight and height data from all students of all schools in four selected school grades (kindergarten, 4th, 7th and 10th years) were collected by cross-sectional surveys for periods 1998-9 (3,676 boys, 3,715 girls) and 2005-6 (4,867 boys, 4,846 girls). Data from 1956-7 was extracted from a previously published report. Results: Height increased, in boys, by 1.6 cm/decade for the period 1956-7 to 1998- 9, and 1.1 cm/decade for the period 1998-8 to 2005-6; in girls, the corresponding figures were 0.9 cm/decade and 1.8 cm/decade. At age 15.5 years, boys/girls were taller by 10/13 cm in 2005-6 than in 1956-7. Weight increased, in boys, by 1.4 kg/decade for the period 1956-7 to 1998-9, and by 2.2 kg/decade for the subsequent period; the corresponding figures in girls were 1.1 kg/decade and 2.5 kg/decade. Conclusion: Marked upward secular trends in body height and weight were documented in children and adolescents aged <16 years in the Seychelles, consistent with large changes in socio-economic and nutritional indicators in the considered 50- year interval. However, indirect evidence suggests that the secular height gain reflects accelerated growth during childhood over time with less than commensurate impact on adult height. Conversely, the largely steeper secular increase in weight than height is consistent with a pediatric obesity epidemic.
Resumo:
Using genome-wide data from 253,288 individuals, we identified 697 variants at genome-wide significance that together explained one-fifth of the heritability for adult height. By testing different numbers of variants in independent studies, we show that the most strongly associated ∼2,000, ∼3,700 and ∼9,500 SNPs explained ∼21%, ∼24% and ∼29% of phenotypic variance. Furthermore, all common variants together captured 60% of heritability. The 697 variants clustered in 423 loci were enriched for genes, pathways and tissue types known to be involved in growth and together implicated genes and pathways not highlighted in earlier efforts, such as signaling by fibroblast growth factors, WNT/β-catenin and chondroitin sulfate-related genes. We identified several genes and pathways not previously connected with human skeletal growth, including mTOR, osteoglycin and binding of hyaluronic acid. Our results indicate a genetic architecture for human height that is characterized by a very large but finite number (thousands) of causal variants.
Resumo:
Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.
Resumo:
This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.
Resumo:
A ubiquitous assessment of swimming velocity (main metric of the performance) is essential for the coach to provide a tailored feedback to the trainee. We present a probabilistic framework for the data-driven estimation of the swimming velocity at every cycle using a low-cost wearable inertial measurement unit (IMU). The statistical validation of the method on 15 swimmers shows that an average relative error of 0.1 ± 9.6% and high correlation with the tethered reference system (rX,Y=0.91 ) is achievable. Besides, a simple tool to analyze the influence of sacrum kinematics on the performance is provided.