254 resultados para Blood Pressure Determination


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The calcium channel blocker isradipine has become recently available in a form with delayed release (isradipine SRO). The anti-hypertensive efficacy and tolerance of this preparation at a single daily dose of 5 mg was studied in 40 patients with uncomplicated essential hypertension over a period of 6 weeks. Blood pressure during office visits decreased under Isradipine SRO from 164/105 +/- 16/7 to 144/93 +/- 12/7 mmHg (mean +/- 1 standard deviation p < 0.001). Using ambulatory blood pressure recording we could show that antihypertensive efficacy of the new galenic form persisted over 24 hours. During the day the blood pressure dropped from 150/95 +/- 13/7 to 141/91 +/- 13/7 mmHg (p < 0.001), during the night from 131/85 +/- 13/3 to 121/81 +/- 15/9 mmHg (p < 0.001). Heart-rate was not changed by treatment and the drug was well tolerated. Isradipine SRO at a single dose is thus well suited for antihypertensive treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambulatory blood pressure profiles were obtained with the portable semi-automatic blood pressure recorder Remler M2000 in groups of 20 adolescents, 20 young and 20 middle-aged adults and 20 elderly untreated patients, all considered by their physician to be hypertensive. It was found that adolescents who are hypertensive when seeing their physician are more often normotensive outside the physician's office than adult and elderly patients under similar conditions. The increased heart rate variability which was detected in adolescents was not associated with an enhanced blood pressure variability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little information exists regarding the effect of several obesity markers on blood pressure (BP) levels in youth. Transverse study including 2494 boys and 2589 girls. Height, weight and waist were measured according to the international criteria and body fat (BF) by bioimpedance. BP was measured by an automated device. Hypertension was defined using sex-specific, age-specific and height-specific observation-points. Body mass index (BMI) and waist were positively related with systolic blood pressure (SBP) and diastolic blood pressure (DBP) and heart rate in both sexes, whereas the relationships with BF were less consistent. Stepwise linear regression analysis showed that BMI was positively related with SBP and DBP in both sexes, whereas BF was negatively related with SBP in both sexes and with heart rate in boys only; finally, waist was positively related with SBP in boys and heart rate in girls. Age and heart rate-adjusted values of SBP and DBP increased with BMI: for SBP, 117+/-1, 123+/-1 and 124+/-1 mmHg in normal, overweight and obese boys, respectively; corresponding values for girls were 111+/-1, 114+/-1 and 116+/-2 mmHg (mean+/-SE, P<0.001). Overweight and obese boys had an odds ratio for being hypertensive of 2.26 (95% confidence interval: 1.79-2.86) and 3.36 (2.32-4.87), respectively; corresponding values for girls were 1.58 (confidence interval 1.25-1.99) and 2.31 (1.53-3.50). BMI, not BF or waist, is consistently and independently related to BP levels in children; overweight and obesity considerably increase the risk of hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambulatory blood pressure (BP) was recorded in hypertensive patients whose physicians had been asked to reduce diastolic pressure measured in the office to 90 mm Hg or less. 34 hypertensive patients with a diastolic pressure measured by their physician of 95 mm Hg or more despite antihypertensive therapy had their treatment changed with the aim of achieving this pre-set goal within 3 months. At the beginning and the end of the study, ambulatory BP was monitored during the daytime with a portable non-invasive recorder. The results of the ambulatory recordings were not made available to the physicians until completion of the study. In half the patients the ambulatory diastolic pressure was already 90 mm Hg or less at the start. In these patients, treatment adjustment did not further decrease ambulatory BP. In contrast, patients who initially had an ambulatory diastolic pressure above 90 mm Hg had a significantly decreased ambulatory BP at the end of the study. Intensifying the therapy of hypertensive patients who have a normal ambulatory BP may result in overtreatment without any real gain in BP control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood pressures measured casually by a doctor often differ considerably from those recorded during everyday activities away from the medical environment. In the present study, we compared office and ambulatory recorded pressures in 475 consecutive untreated patients diagnosed hypertensive by physicians. Blood pressure monitored non-invasively during the day was, on average 15/7 mmHg lower than the corresponding office pressures. The difference between office and ambulatory recorded pressure tended to be greatest in those patients with the highest office blood pressure levels, although the relationship between the two types of measurement was too weak (r = 0.50 and 0.38 for systolic and diastolic pressure, respectively) to have any predictive value in the individual patient. Office blood pressures were at least 10 mmHg higher than ambulatory pressures in 62% of patients for systolic and 42% for diastolic pressure. Blood pressure levels recorded during ambulatory monitoring were higher than in the doctor's office for 18% of patients for systolic and 22% for diastolic pressure. Among patients with systolic pressures of between 161 and 180 mmHg or diastolic pressures between 96 and 105 mmHg when facing a doctor, 27 and 37% respectively, showed markedly lower systolic (less than 140 mmHg) or diastolic (less than 90 mmHg) ambulatory recorded pressures. These data therefore indicate that ambulatory blood pressure monitoring may help to identify those truly hypertensive patients who are most likely to benefit from antihypertensive therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study we determine whether blood pressure readings using a cuff of fixed size systematically differed from readings made with a triple-bladder cuff (Tricuff) that automatically adjusts bladder width to arm circumference and assessed subsequent clinical and epidemiological effects. Blood pressure was measured with a standard cuff or a Tricuff in 454 patients visiting an outpatient clinic in the Seychelles (Indian Ocean). Overall means of within-individual standard cuff-Tricuff differences in systolic and diastolic blood pressures were examined in relation to arm circumference and sex. The standard cuff-Tricuff difference in systolic and diastolic blood pressures increased monotonically with circumference (from 4.7 +/- 0.8/3.2 +/- 0.7 mm Hg for arm circumference of 30 to 31 cm to 10.0 +/- 1.1/8.0 +/- 0.9 mm Hg for arm circumference &gt; or = 36 cm) and was larger in women than men. Multivariate linear regression indicated independent effects of arm circumference and sex. Forty percent of subjects with a diastolic blood pressure of &gt; or = 95 mm Hg measured with a standard cuff had values less than 95 mm Hg measured with a Tricuff. Extrapolation to the entire population of the Seychelles decreased the prevalence of blood pressure greater than or equal to 160/95 mm Hg by 11.5% and 24.0% in men and women, respectively, aged 35 to 64 years. The age-adjusted effect of body mass index on systolic and diastolic blood pressures decreased twofold using blood pressure readings made with a Tricuff instead of a standard cuff.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Because ambulatory blood pressure monitoring (ABPM) is not available everywhere, the objective of the study was to determine whether nurse-measured blood pressure could be an acceptable substitute to ABPM. METHODS: We analyzed the data of 2385 consecutive patients referred to our hypertension clinic for the performance of ABPM. Before ambulatory monitoring was performed, a nurse-measured BP was obtained three times using a Y-tube connecting the sphygmomanometer and the recorder. We compared the mean value of the three nurse-measured blood pressures with that of the 12h daytime ambulatory monitoring, considered as the reference. RESULTS: The difference between the nurse-measured and the ambulatory blood pressure was small but statistically significant, indicating that nurse-measured blood pressure tends to overestimate both diastolic and systolic blood pressure. The difference between the nurse blood pressure and ABPM was greater among treated hypertensive patients than untreated patients. To diagnose hypertension, defined as a blood pressure of over 140/90mmHg by ABPM, the positive predictive value of the nurse blood pressure was 0.81 and the negative predictive value 0.63. However, these predictive values could be improved with less stringent cut-off values of blood pressure. Thus, for a diastolic blood pressure above 100mmHg, the positive predictive value of nurse blood pressure was 0.55 and the negative predictive value 0.91. These figures were relatively similar for previously treated and untreated patients. CONCLUSION: Nurse blood pressure is less accurate than ABPM in diagnosing hypertension, defined as a blood pressure of over 140/90mmHg. It could, however, be an acceptable substitute, especially to exclude people who do not need to be treated, in situations where lower resources require a less rigorous definition of hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Children with elevated blood pressure are at risk of being hypertensive in adulthood and of developing complications such as ventricular hypertrophy. Obesity is a cause of hypertension. Because the prevalence of obesity is increasing, some authors argue that the systematic screening for hypertension in children and adolescents is justified for early prevention and treatment. Sex, age and height all influence children's blood pressure. When elevated blood pressure is identified, complementary investigations and treatment might be necessary. However, due to the difficulties of obtaining a valid estimate of blood pressure, to the moderate tracking of blood pressure from childhood to adulthood, and the rarity of hypertension cases in childhood, the usefulness of systematic screening of hypertension during childhood is still controversial. Un enfant dont la pression artérielle est élevée a un risque accru d'être hypertendu à l'âge adulte et de présenter des complications telles que l'hypertrophie ventriculaire gauche. L'augmentation de la prévalence de l'obésité justifierait selon certains auteurs le dépistage systématique de l'hypertension dès le plus jeune âge afin d'instaurer des mesures préventives ou curatives précoces. Les normes de pression dépendent du sexe, de l'âge et de la taille de l'enfant. En cas de pression élevée, des investigations complémentaires, voire un traitement, peuvent être indiqués. Au vu des difficultés pour obtenir une mesure fiable, des incertitudes entachant la valeur pronostique d'une pression artérielle élevée et de la rareté des cas d'hypertension, il n'y a pas de consensus sur l'utilité du dépistage systématique de l'hypertension durant l'enfance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to assess the effects of physical fitness on the relationships between body mass index (BMI) and body fat (BF) on blood pressure (BP) levels. Cross-sectional study conducted in 25 schools of Lisbon (Portugal), including 2041 boys and 1995 girls aged 10-18. BF was assessed by bioimpedance. Cardiovascular fitness was assessed by the 20-meter shuttle run and classified as fit/unfit. Obesity (BMI or BF defined) was defined according to international criteria. In both sexes, BMI was positively related with systolic and diastolic BP, while BF was only positively related with diastolic BP z-scores. No interaction was found between fitness and BMI categories regarding BP levels, while for BF a significant interaction was found. Being fit reduced the BF-induced increase in the Odds ratio (OR) of presenting with high BP: OR (95% confidence interval) 1.01 (0.73-1.40) and 0.99 (0.70-1.38) for overweight and obese fit boys, respectively, the corresponding values for unfit overweight and obese boys being 1.33 (0.94-1.90) and 1.75 (1.34-2.28), respectively. The values were 0.88 (0.57-1.35) and 1.66 (0.98-2.80) for overweight and obese fit girls, respectively, the corresponding values for unfit overweight and obese being 1.63 (1.12-2.37) and 1.90 (1.32-2.73) respectively. No interaction was found between fitness and BMI-defined overweight and obesity. Being fit reduces the negative impact of BF on BP levels and high BP status in adolescents. This protective effect was not found with BMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we assessed whether the white-coat effect (difference between office and daytime blood pressure (BP)) is associated with nondipping (absence of BP decrease at night). Data were available in 371 individuals of African descent from 74 families selected from a population-based hypertension register in the Seychelles Islands and in 295 Caucasian individuals randomly selected from a population-based study in Switzerland. We used standard multiple linear regression in the Swiss data and generalized estimating equations to account for familial correlations in the Seychelles data. The prevalence of systolic and diastolic nondipping (<10% nocturnal BP decrease) and white-coat hypertension (WCH) was respectively 51, 46, and 4% in blacks and 33, 37, and 7% in whites. When white coat effect and nocturnal dipping were taken as continuous variables (mm Hg), systolic (SBP) and diastolic BP (DBP) dipping were associated inversely and independently with white-coat effect (P < 0.05) in both populations. Analogously, the difference between office and daytime heart rate was inversely associated with the difference between daytime and night-time heart rate in the two populations. These results did not change after adjustment for potential confounders. The white-coat effect is associated with BP nondipping. The similar associations between office-daytime values and daytime-night-time values for both BP and heart rate suggest that the sympathetic nervous system might play a role. Our findings also further stress the interest, for clinicians, of assessing the presence of a white-coat effect as a means to further identify patients at increased cardiovascular risk and guide treatment accordingly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS: We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mannheim, Germany) in lean (n=15) and obese (n=11) patients. RESULTS: No difference was found in diastolic BP between the two groups, nor between the arm and the wrist. Systolic BP measured at the arm was, however, significantly lower in obese (99+/-9 mmHg, mean+/-SD) than in lean (107+/-14 mmHg; P<0.001) patients, whereas systolic BP determined at the wrist averaged 106 mmHg in both groups. CONCLUSION: The use of validated wrist BP measuring devices appears therefore particularly appealing in obese individuals with a large arm circumference

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of the blood pressure by the physician remains an essential step in the evaluation of cardiovascular risk. Ambulatory measurement and self-measurement of blood pressure are ways of counteracting the "white coat" effect which is the rise in blood pressure many patients experience in the presence of doctors. Thus, it is possible to define the cardiovascular risk of hypertension and identify the patients with the greatest chance of benefiting from antihypertensive therapy. However, it must be realised that normotensive subjects during their everyday activities and becoming hypertensive in the doctor's surgery, may become hypertensive with time, irrespective of the means used to measure blood pressure. These patients should be followed up regularly even if the decision to treat has been postponed.