8 resultados para extraction methods
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Antioxidant enzymes are involved in important processes of cell detoxification during oxidative stress and have, therefore, been used as biomarkers in algae. Nevertheless, their limited use in fluvial biofilms may be due to the complexity of such communities. Here, a comparison between different extraction methods was performed to obtain a reliable method for catalase extraction from fluvial biofilms. Homogenization followed by glass bead disruption appeared to be the best compromise for catalase extraction. This method was then applied to a field study in a metal-polluted stream (Riou Mort, France). The most polluted sites were characterized by a catalase activity 4–6 times lower than in the low-polluted site. Results of the comparison process and its application are promising for the use of catalase activity as an early warning biomarker of toxicity using biofilms in the laboratory and in the field
Resumo:
In general terms key sectors analysis aims at identifying the role, or impact, that the existence of a productive sector has in the economy. Quite a few measures, indicators and methodologies of varied complexity have been proposed in the literature, from multiplier sums to extraction methods, but not without debate about their properties and their information content. All of them, to our knowledge, focus exclusively on the interdependence effects that result from the input-output structure of the economy. By so doing the simple input-output approach misses critical links beyond the interindustry ones. A productive sector’s role is that of producing but also that of generating and distributing income among primary factors as a result of production. Thus when measuring a sector’s role, the income generating process cannot and should not be omitted if we want to better elucidate the sector’ economic role. A simple way to make the missing income link explicit is to use the SAM (Soci
L'explotació de recursos forestals en el nord i en el sud des del punt de vista de la sostenibilitat
Resumo:
El present projecte té com a objectiu l’estudi de la sostenibilitat de l’explotació forestal que es realitza en l’hemisferi nord i en el sud. Per això, s’han escollit quatre països que disposen, dins de les seves fronteres, de grans extensions boscoses, cada un d’ells amb un tipus de bosc diferent: Brasil (Selva Amazònica), República Democràtica del Congo (Selva Equatorial), Canadà (Bosc Boreal) i Espanya (Bosc Mediterrani). Amb aquests països s’ha realitzat una comparativa tant de forma qualitativa com quantitativa. Pel que fa a l’anàlisi qualitatiu, s’han recollit dades del PIB per càpita dels diferents països de l’any 2010 i les principals metodologies d’explotació forestal que aquests realitzen. Així, els països amb més PIB per càpita eren també els països que utilitzaven mètodes d’explotació menys agressius i es consideren, per tant, els països amb una extracció dels seus recursos més sostenible. En quant a l’anàlisi quantitatiu, s’han utilitzat les dades de PIB per càpita, taxa de desforestació (ha/any) i taxa de creixement del bosc (ha/any) de cada tipus de bosc. Amb aquestes dades s’ha construït un índex, l’índex de sostenibilitat d’extracció, que pretén ser una eina d’estandardització per a la comparativa entre països i/o boscos diferents. El resultat ha estat el mateix en les dues anàlisis.
Resumo:
Two concentration methods for fast and routine determination of caffeine (using HPLC-UV detection) in surface, and wastewater are evaluated. Both methods are based on solid-phase extraction (SPE) concentration with octadecyl silica sorbents. A common “offline” SPE procedure shows that quantitative recovery of caffeine is obtained with 2 mL of an elution mixture solvent methanol-water containing at least 60% methanol. The method detection limit is 0.1 μg L−1 when percolating 1 L samples through the cartridge. The development of an “online” SPE method based on a mini-SPE column, containing 100 mg of the same sorbent, directly connected to the HPLC system allows the method detection limit to be decreased to 10 ng L−1 with a sample volume of 100 mL. The “offline” SPE method is applied to the analysis of caffeine in wastewater samples, whereas the “on-line” method is used for analysis in natural waters from streams receiving significant water intakes from local wastewater treatment plants
Resumo:
Estudi elaborat a partir d’una estada a Xerox Research Centre Europe a Grenoble, França,entre juny i desembre del 2006. El projecte tradueïx termes tècnics anglesos a noruec. És asimètric perquè no tenim recursos lingüístics per a la llengua noruega, però solament per a l'anglès. S’ha desenvolupat i posat en pràctica mètodes que comprovaven contigüitat ("local reordering" i permutació selectiva) per a millorar el funcionament d’una eina anterior. Contigüitat és quan una paraula es traduïx en paraules múltiples, aquestes paraules han de ser adjacents en l'oració. A més, s’ha construït una taula de les operacions de recerca per als termes tècnics i s’ha integrat aquesta taula en un programa de demostració.
Resumo:
The two main alternative methods used to identify key sectors within the input-output approach, the Classical Multiplier method (CMM) and the Hypothetical Extraction method (HEM), are formally and empirically compared in this paper. Our findings indicate that the main distinction between the two approaches stems from the role of the internal effects. These internal effects are quantified under the CMM while under the HEM only external impacts are considered. In our comparison, we find, however that CMM backward measures are more influenced by within-block effects than the proposed forward indices under this approach. The conclusions of this comparison allow us to develop a hybrid proposal that combines these two existing approaches. This hybrid model has the advantage of making it possible to distinguish and disaggregate external effects from those that a purely internal. This proposal has also an additional interest in terms of policy implications. Indeed, the hybrid approach may provide useful information for the design of ''second best'' stimulus policies that aim at a more balanced perspective between overall economy-wide impacts and their sectoral distribution.
Resumo:
Monetary policy is conducted in an environment of uncertainty. This paper sets upa model where the central bank uses real-time data from the bond market togetherwith standard macroeconomic indicators to estimate the current state of theeconomy more efficiently, while taking into account that its own actions influencewhat it observes. The timeliness of bond market data allows for quicker responsesof monetary policy to disturbances compared to the case when the central bankhas to rely solely on collected aggregate data. The information content of theterm structure creates a link between the bond market and the macroeconomythat is novel to the literature. To quantify the importance of the bond market asa source of information, the model is estimated on data for the United Statesand Australia using Bayesian methods. The empirical exercise suggests that thereis some information in the US term structure that helps the Federal Reserve toidentify shocks to the economy on a timely basis. Australian bond prices seemto be less informative than their US counterparts, perhaps because Australia is arelatively small and open economy.
Resumo:
This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).