12 resultados para bandwidth 2.0 GHz to 2.45 GHz
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
We investigated the rheological properties of living human airway smooth muscle cells in culture and monitored the changes in rheological properties induced by exogenous stimuli. We oscillated small magnetic microbeads bound specifically to integrin receptors and computed the storage modulus (G') and loss modulus (G") from the applied torque and the resulting rotational motion of the beads as determined from their remanent magnetic field. Under baseline conditions, G' increased weakly with frequency, whereas G" was independent of the frequency. The cell was predominantly elastic, with the ratio of G" to G' (defined as eta) being ~0.35 at all frequencies. G' and G" increased together after contractile activation and decreased together after deactivation, whereas eta remained unaltered in each case. Thus elastic and dissipative stresses were coupled during changes in contractile activation. G' and G" decreased with disruption of the actin fibers by cytochalasin D, but eta increased. These results imply that the mechanisms for frictional energy loss and elastic energy storage in the living cell are coupled and reside within the cytoskeleton.
Resumo:
En aquest treball s’ha dissenyat i fabricat una antena monopol en estructura planar capaç de treballar correctament a les freqüències WLAN de 2,45-2,5 GHz (802.11b/g) i 4,9-5,875 GHz (802.11a/h/j). Per arribar a aquest objectiu primer s’ha presentat el model de línia de transmissió acabada en circuit obert per simular el comportament d’una antena. S’han comparat i verificat els resultats amb el model d’antena de fil. Seguidament, s’ha estudiat el comportament que introdueix el fet de carregar l’antena amb un ressonador LC. Finalment, s’ha passat del model d’antena de fil a una estructura planar. Aquesta geometria ha permès la realització del trap LC de forma distribuïda a través d’un ressonador CLL. El principi de disseny de l’antena està basat en la introducció d’aquest ressonador CLL amb freqüència de ressonància situada entre les dos bandes de treball i que junt amb l’ajust dels diversos paràmetres que defineixen l’antena han permès obtenir més 1 GHz d’ample de banda a la freqüència de 5 GHz.
Resumo:
El propósito de esta comunicación es analizar el estado actual de los periódicos digitales, prestandoespecial atención a la adaptación de éstos al entorno de la Web 2.0. Para llevar a cabo este trabajo sehan estudiado, entre otras, las siguientes variables: el tipo de herramientas propias de la Web 2.0que los periódicos digitales han incorporado a sus sitios web, la forma en que éstas ha cambiado elproceso de creación de los productos periodísticos, la respuesta que los periódicos digitales hanrecibido por parte de la audiencia y el nuevo tipo de interacción creado con los usuarios.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
El concepto web 2.0 se utiliza para denominar a un conjunto de aplicaciones que están siempre en evolución de acuerdo a los requerimientos que los usuarios van realizando. En la red podemos encontrar muchas herramientas desarrolladas en la línea de la web 2.0: blogs, wikis, herramientas para compartir marcadores, para compartir archivos, etc. Consideramos que el sistema educativo no puede estar al margen de esta evolución tecnológica y necesita adaptarse a todos los niveles. Las universidades también se encuentran en la necesidad de adecuarse a estos nuevos tiempos, y cada vez encontramos más experiencias formativas de trabajo colaborativo en red para favorecer el aprendizaje de los estudiantes. El trabajo que presentamos es un análisis de herramientas web 2.0 y de una recopilación de buenas prácticas docentes universitarias de desarrollo de metodologías colaborativas utilizando las TIC. Además, ofrecemos recomendaciones del uso de estas herramientas en los procesos de enseñanza y aprendizaje universitario.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
By exciting at 788 nm, we have characterized the near infrared emissions of trivalent thulium ions in monoclinic KGd(WO4)2 single crystals at 1.48 and 1.84 mm as a function of dopant concentration from 0.1% to 10% and temperature from 10 K to room temperature. We used the reciprocity method to calculate the maximum emission cross-section of 3.0310220 cm2 at 1.838 mm for the polarization parallel to the Nm principal optical direction. These results agrees well with the experimental data. Experimental decay times of the 3H4!3F4 and 3F4!3H6 transitions have been measured as a function of thulium concentration.
Resumo:
It has been long stated that there are profound analogies between fracture experiments and earthquakes; however, few works attempt a complete characterization of the parallelisms between these so separate phenomena. We study the Acoustic Emission events produced during the compression of Vycor (SiO&sub&2&/sub&). The Gutenberg-Richter law, the modified Omori's law, and the law of aftershock productivity hold for a minimum of 5 decades, are independent of the compression rate, and keep stationary for all the duration of the experiments. The waiting-time distribution fulfills a unified scaling law with a power-law exponent close to 2.45 for long times, which is explained in terms of the temporal variations of the activity rate.
Resumo:
Background: Vorapaxar is a new oral protease-activatedreceptor 1 (PAR-1) antagonist that inhibits thrombin-induced platelet activation. Methods: In this multinational, double-blind, randomized trial, we compared vorapaxar with placebo in 12,944 patients who had acute coronary syndromes without ST-segment elevation. The primary end point was a composite of death from cardiovascular causes, myocardial infarction, stroke, recurrent ischemia with rehospitalization, or urgent coronary revascularization. RESULTS: Follow-up in the trial was terminated early after a safety review. After a median follow-up of 502 days (interquartile range, 349 to 667), the primary end point occurred in 1031 of 6473 patients receiving vorapaxar versus 1102 of 6471 patients receiving placebo (KaplanMeier 2-year rate, 18.5% vs. 19.9%; hazard ratio, 0.92; 95% confidence interval [CI], 0.85 to 1.01; P = 0.07). A composite of death from cardiovascular causes, myocardial infarction, or stroke occurred in 822 patients in the vorapaxar group versus 910 in the placebo group (14.7% and 16.4%, respectively; hazard ratio, 0.89; 95% CI, 0.81 to 0.98; P = 0.02). Rates of moderate and severe bleeding were 7.2% in the vorapaxar group and 5.2% in the placebo group (hazard ratio, 1.35; 95% CI, 1.16 to 1.58; P<0.001). Intracranial hemorrhage rates were 1.1% and 0.2%, respectively (hazard ratio, 3.39; 95% CI, 1.78 to 6.45; P<0.001). Rates of nonhemorrhagic adverse events were similar in the two groups. Conclusions: In patients with acute coronary syndromes, the addition of vorapaxar to standard therapy did not significantly reduce the primary composite end point but significantly increased the risk of major bleeding, including intracranial hemorrhage. (Funded by Merck; TRACER ClinicalTrials.gov number, NCT00527943.)
Resumo:
Background: Vorapaxar is a new oral protease-activated-receptor 1 (PAR-1) antagonist that inhibits thrombin-induced platelet activation. Methods: In this multinational, double-blind, randomized trial, we compared vorapaxar with placebo in 12,944 patients who had acute coronary syndromes without ST-segment elevation. The primary end point was a composite of death from cardiovascular causes, myocardial infarction, stroke, recurrent ischemia with rehospitalization, or urgent coronary revascularization. RESULTS: Follow-up in the trial was terminated early after a safety review. After a median follow-up of 502 days (interquartile range, 349 to 667), the primary end point occurred in 1031 of 6473 patients receiving vorapaxar versus 1102 of 6471 patients receiving placebo (Kaplan-Meier 2-year rate, 18.5% vs. 19.9%; hazard ratio, 0.92; 95% confidence interval [CI], 0.85 to 1.01; P = 0.07). A composite of death from cardiovascular causes, myocardial infarction, or stroke occurred in 822 patients in the vorapaxar group versus 910 in the placebo group (14.7% and 16.4%, respectively; hazard ratio, 0.89; 95% CI, 0.81 to 0.98; P = 0.02). Rates of moderate and severe bleeding were 7.2% in the vorapaxar group and 5.2% in the placebo group (hazard ratio, 1.35; 95% CI, 1.16 to 1.58; P<0.001). Intracranial hemorrhage rates were 1.1% and 0.2%, respectively (hazard ratio, 3.39; 95% CI, 1.78 to 6.45; P<0.001). Rates of nonhemorrhagic adverse events were similar in the two groups. Conclusions: In patients with acute coronary syndromes, the addition of vorapaxar to standard therapy did not significantly reduce the primary composite end point but significantly increased the risk of major bleeding, including intracranial hemorrhage. (Funded by Merck; TRACER ClinicalTrials.gov number, NCT00527943.)
Resumo:
Pain is defined as an unpleasant sensory or emotional experience, associated with tissue damage, that is a reality linked to the surgical procedure and the postoperative period. Objective: Knowing the degree of pain experienced by patients after cardiac surgery, depending on the type of intervention they underwent, over the post-operative period in an intensive care unit (ICU). Method: Descriptive observational study. Pain was assessed by the visual analog scale (VAS), going from 0 to 10, thereby obtaining the first VAS1 assessment at 2 h post-extubation and every 8 hours thereafter up to 48 hours or until discharge to floor VAS7. It included patients having undergone cardiac surgery [valve surgery, bypass, combined procedure (including valve surgery and bypass) and mediastinitis]. Data were processed using Spss.v 20. Results: 120 patients 70 years old on average (standard deviation (SD): 13.3 years old) were included, out of which 70% were male. 40.8% of them had underwent bypass coronary revascularization. Patients subjected to the bypass technique showed an VAS1 mean value of 4.35 (SD: 2.45), unlike those subjected to valve surgery, who showed a mean value of 2.89 (SD: 2.27), those subjected to the combined procedure, who showed a mean value of 3.87 (SD: 2.90), and those with mediastinitis, who showed a mean value of 3.33 (SD: 3.51); (p < 0.031). 28.5% of patients had underwent revascularization (n = 49 ) by an internal mam mary artery (IMA) graft. These patients showed a mean value for VAS1 of 5.4 (SD: 1.89), unlike those who had underwent a combined procedure [IMA and saphenous vein (SV)], who showed a mean value of 3.9 (SD: 2.6), and those who had underwent a SV procedure , who showed a mean value of 3.5 (SD: 2.1); (p < 0.045). Conclusions: Patients having underwent bypass and IMA procedures perceive more pain than in other cardiac surgery and graft interventions
Resumo:
A method to generate carbonylic compounds from alkynes under mild and neutral conditions, with excellent functional group compatibility and high yields, is described. Hydration takes place under catalytic conditions by using from 0.1 to 0.2 equivalents of the easily available and inexpensive mercury(II) p-toluensulfonamidate in a hydroalcoholic solution. After use the catalyst is iner tized and/or recycled ...