27 resultados para Titanium impurities
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
The nature of the chemical bond in three titanium oxides of different crystal structure and different formal oxidation state has been studied by means of the ab initio cluster-model approach. The covalent and ionic contributions to the bond have been measured from different theoretical techniques. All the analysis is consistent with an increasing of covalence in the TiO, Ti2O3, and TiO2 series as expected from chemical intuition. Moreover, the use of the ab initio cluster-model approach combined with different theoretical techniques has permitted us to quantify the degree of ionic character, showing that while TiO can approximately be described as an ionic compound, TiO2 is better viewed as a rather covalent oxide.
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
Es presenten els resultats experimentals obtinguts durant l’estudi sistemàtic realitzat de la preparació electroquímica de puntes de tungstè per al Microscopi d’Efecte Túnel (STM), fent servir dos electròlits: KOH i NaOH. L’estudi sobre la morfologia, longitud de la punta i radi de curvatura de la punta en funció del voltatge aplicat i les concentracions de l’electròlit es descriu al capítol 3. La caracterització de les puntes es va dur a terme, per una part, mitjançant un microscòpic electrònic de rastreig (SEM) i per l’altre banda, amb el ús de les puntes obtingudes al STM. En resumen, els resultats mostren que ambdós electròlits permeten obtenir puntes que es poden fer servir amb èxit per l’obtenció d’imatges amb l’STM. Les millors puntes són aquelles que s’obtenen dins de rangs de concentracions d’electròlit baixes, entre valor de 10 a 15% en pes pel NaOH i entre 10 i 20% pel KOH i rangs de voltatge entre 3 a 7 V pel NaOH i 4 a 8 V pel KOH. S’observa que es requereixen temps d’atac electroquímic menors fent servir com a electròlit NaOH. S’estudia, en el capítol 4, el tractament que requereix la punta per tal d’eliminar les impureses de la seva superfície. Es realitzen diferents proves amb tres mètodes de neteja: (1) tractament químic, (2) bombardeig iònic i (3) tractament tèrmic de recuit. En el capítol 5 del projecte s’analitzen les imatges d’una mostra d’or, Au(110), d’estructura coneguda, amb el microscopi d’efecte túnel STM) del laboratori fent servir les puntes obtingudes sota les condicions considerades òptimes. El resultat confirma el bon comportament de les puntes obtingudes sota les condicions descrites en els capítols anteriors i establert una pauta a seguir per obtenir puntes d’una manera senzilla i reproduïble.
Resumo:
Natural Orifice Transluminal Endoscopic Surgery (NOTES) is a novel, potentially less invasive alternative to laparoscopic surgery. However, the problems of transluminal access and closure represent significant obstacles to its successful introduction in humans. Objective: to evaluate the feasibility and safety of a novel device designed for transluminal access and closure in a survival porcine model. Subjects: Four adult female Yorkshire pigs were used in the study. Interventions: While under general anesthesia, the animals were prepared with multiple tap water enemas followed by instillation of an antibiotic suspension and povidone-iodine lavage. At a distance of 15 to 20 cm from the anus, the prototype device (LSI Solutions, Victor, NY, USA) deployed a circumscribing purse-string suture around the planned incision site and subsequently used a blade mechanism to create a 2.5-cm linear incision. The transcolonic incision was then closed by cinching and securing the purse-string suture with a titanium knot by use of a separate hand-activated suture-locking device. Main Outcome Measurements: The animals were monitored daily for signs of peritonitis and sepsis and were survived for 14 days. The peritoneal cavity was examined for peritonitis, and the colonic incision site was examined for wound dehiscence, pericolic abscess formation, and gross adhesions. Tissue samples from both incisional and random peritoneal sites were obtained for histologic examination. Results: Transcolonic incision and closure were successful in all 4 animals. The device performed in a rapid and reproducible fashion. All animals recovered without septic complications. At necropsy, there was no evidence of peritonitis, abscesses, or wound dehiscence. Salpingocolonic and colovesicular adhesions were noted in 3 of 4 animals. Histologic examination revealed microabscesses at the incision site in all animals. Conclusions: The prototype incision and closure device represents a promising solution to the problems of transluminal access for NOTES. The presence of incision-related adhesions and microabscesses signal the need for further refinement in aseptic technique.
Resumo:
L'objectiu d'aquest projecte és aprofundir en les noves tecnologies que permeten desenvolupar aplicacions multiplataforma per a dispositius mòbils i fer un estudi comparatiu entre algunes d'elles. També es realitza un estudi comparatiu entre les aplicacions generades amb aquestes tecnologies multiplataforma i les generades amb codi natiu del propi sistema.
Resumo:
We show that, at high densities, fully variational solutions of solidlike types can be obtained from a density functional formalism originally designed for liquid 4He . Motivated by this finding, we propose an extension of the method that accurately describes the solid phase and the freezing transition of liquid 4He at zero temperature. The density profile of the interface between liquid and the (0001) surface of the 4He crystal is also investigated, and its surface energy evaluated. The interfacial tension is found to be in semiquantitative agreement with experiments and with other microscopic calculations. This opens the possibility to use unbiased density functional (DF) methods to study highly nonhomogeneous systems, like 4He interacting with strongly attractive impurities and/or substrates, or the nucleation of the solid phase in the metastable liquid.
Resumo:
We show that small amounts of 3He atoms, added to a 4He drop deposited on a flat cesium surface at zero temperature, populate bound states localized at the contact line. These edge states show up for drops large enough to develop well defined surface and bulk regions together with a contact line, and they are structurally different from the well-known Andreev states that appear at the free surface and at the liquid-solid interface of films. We illustrate the one-body density of 3He in a drop with 1000 4He atoms, and show that for a sufficiently large number of impurities the density profiles spread beyond the edge, coating both the curved drop surface and its flat base and eventually isolating it from the substrate.
Resumo:
We present static and dynamical properties of linear vortices in 4He droplets obtained from density functional calculations. By comparing the adsorption properties of different atomic impurities embedded in pure droplets and in droplets where a quantized vortex has been created, we suggest that Ca atoms should be the dopant of choice to detect vortices by means of spectroscopic experiments.
Resumo:
Laser-induced forward transfer (LIFT) is a laser direct-write technique that offers the possibility of printing patterns with a high spatial resolution from a wide range of materials in a solid or liquid state, such as conductors, dielectrics, and biomolecules in solution. This versatility has made LIFT a very promising alternative to lithography-based processes for the rapid prototyping of biomolecule microarrays. Here, we study the transfer process through the LIFT of droplets of a solution suitable for microarray preparation. The laser pulse energy and beam size were systematically varied, and the effect on the transferred droplets was evaluated. Controlled transfers in which the deposited droplets displayed optimal features could be obtained by varying these parameters. In addition, the transferred droplet volume displayed a linear dependence on the laser pulse energy. This dependence allowed determining a threshold energy density value, independent of the laser focusing conditions, which acted as necessary conditions for the transfer to occur. The corresponding sufficient condition was given by a different total energy threshold for each laser beam dimension. The threshold energy density was found to be the dimensional parameter that determined the amount of the transferred liquid per laser pulse, and there was no substantial loss of material due to liquid vaporization during the transfer.
Resumo:
The synthesis of magnetic nanoparticles with monodispere size distributions, their self assembly into ordered arrays and their magnetic behavior as a function of structural order (ferrofluids and 2D assemblies) are presented. Magnetic colloids of monodispersed, passivated, cobalt nanocrystals were produced by the rapid pyrolysis of cobalt carbonyl in solution. The size, size distribution (std. dev.< 5%) and the shape of the nanocrystals were controlled by varying the surfactant, its concentration, the reaction rate and the reaction temperature. The Co particles are defect-free single crystals with a complex cubic structure related to the beta phase of manganese (epsilon-Co). In the 2D assembly, a collective behavior was observed in the low-field susceptibility measurements where the magnetization of the zero field cooled process increases steadily and the magnetization of the field cooling process is independent the temperature. This was different from the observed behavior in a sample comprised of disordered interacting particles. A strong paramagnetic contribution appears at very low temperatures where the magnetization increases drastically after field cooling the sample. This has been attributed to the Co surfactant-particle interface since no magnetic atomic impurities are present in these samples.
Resumo:
En este trabajo se ha estudiado el proceso de gelificación desde un nuevo punto de vista: el seguimiento de la transición solgel mediante la evolución con el tiempo de la distribución de tiempos de relajación, que está directamente relacionada con la distribución de pesos moleculares. La técnica utilizada para la determinación de la distribución de tiempos de relajación es la reología. El proceso de gelificación se ha seguido de forma continua mediante dos ensayos reológicos distintos: (1) ensayos dinámicos u oscilatorios y (2) ensayos de retardo y recuperación, con el objetivo de caracterizar de forma completa la viscoelasticidad del sistema a lo largo de todo el proceso. El estudio ha abarcado todos los estadios de la gelificación: (a) el estadio pre-gel, (b) el propio estadio gel y (c) el estadio post-gel. Los procesos estudiados corresponden a soles poliméricos de titanio y de silicio. Los resultados obtenidos permiten evaluar la influencia de la composición de los soles, así como comparar los dos tipos de soles analizados. Además, permiten describir el tiempo de gelificación desde una nueva perspectiva, basada en la distribución de tiempos de relajación, ya que se observa que este momento corresponde a una distribución de polidispersidad máxima.