Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture. Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths- while only two fractured implants were supporting overdentures instead of fixed prostheses. The great majority of fractured implants (80.9%) were located in the molar and premolar regions, and most fractured within 3-4 years after loading. It is important to know and apply the measures required to prevent implant fracture, and to seek the best individualized solution for each case - though complete implant removal is usually the treatment of choice

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Assess the main problems referred by the patients and observed by the professionals after the bucodental rehabilitation with an implant-supported hybrid prothesis. Patients and Methods: A retrospective study was carried out in which there were 43 patients included who were visited in the Department of Oral Surgery and Orofacial Implantology of University of Barcelona Dental School for one year. An oral rehabilitation with an implant-supported hybrid prosthesis was made to those patients. The following variables were registered: age, gender, number of inserted implants, type of implant and principal problems produced by the hybrid prosthesis. Results: The rehabilitation with an implant supported hybrid prosthesis was only performed in 43 of 116 cases treated in one year (January, 2006 to January, 2007). They were 26 men and 17 women of ages between 37 and 74 years, being the rate age of 56,5 years. The main complication recorded was the mucositis, associated frequently with a difficulty to carry a correct oral hygiene and to an overextention of the tail of resin of the prosthesis. Other observed problems were the peri-implantitis, the break of the acrylic teeth and the loss of some of the prosthetic screws. Conclusions: The most frequent complication after the laying of an implant supported hybrid prosthesis was the mucositis, associated mainly with a prosthetic tail too long and to the consequent difficulty of carrying a correct oral hygiene. In spite of the high prevalence of observed complications, most of them were mild and resolved on subsequent visits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Zygomatic implants are a good rehabilitation alternative for upper maxilla with severe bone reabsorption. These implants reduce the need for onlay-type bone grafting in the posterior sectors and for maxillary sinus lift procedures - limiting the use of bone grafts to the anterior zone of the upper jaw in those cases where grafting is considered necessary. Objective: To evaluate the survival of 101 zygomatic implants placed in upper maxilla presenting important bone reabsorption, with a follow-up of 1-72 months. Patients and methods: A retrospective study was made of 101 Zygoma® implants (Nobel Biocare, Göteborg, Sweden) placed in 54 patients with totally edentulous and atrophic upper maxilla, in the period between 1998-2004. There were 35 women and 19 men, subjected to rehabilitation in the form of fixed prostheses and overdentures using 1-2 zygomatic implants and 2-7 implants in the anterior maxillary zone. The principal study variables were smoking, a history of sinusitis, the degree of bone reabsorption, and peri-implant bone loss, among others. Results: The descriptive analysis of the 101 zygomatic implants placed in 54 patients with a mean age of 56 years (range 38-75) yielded a percentage survival of 96.04%, with four failed implants that were removed (two before and two after prosthetic loading). Nine patients were smokers, and none of the 54 subjects reported a history of sinus disorders. Discussion and conclusions: Zygomatic implants are designed for use in compromised upper maxilla. They allow the clinician to shorten the treatment time, affording an interesting alternative for fixed prosthetic rehabilitation. This study confirms that zygomatic bone offers predictable anchorage and acceptable support function for prostheses in atrophic jaws. However, these implants are not without complications. Longer-term evaluations are needed of zygomatic implant survival in order to establish a correct clinical prognosis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La aparición de cáncer bucal está vinculada a múltiples factores de riesgo. En este artículo queremos exponer como uno de ellos la úlcera crónica producida por las prótesis dentales removibles o fijas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La estomatitis protésica es una inflamación crónica de la mucosa oral debida al contacto con una prótesis extraible. Es un proceso difícil de controlar en los pacientes portadores de este tipo de prótesis. La patología involucra diferentes factores predisponentes, y el más importante de ellos es la presencia de Candida. En el presente artículo se describe el manejo del paciente y las dificultades de los tratamientos actuales para eliminar de las prótesis y de la mucosa oral los residuos fúngicos. Se concluye que los hábitos de higiene oral y personal en pacientes portadores de prótesis extraible son los métodos principales para evitar la aparición de la patología. Una vez instaurada, podemos controlar al paciente con medidas higiénicas y agentes antifúngicos, pero debemos ser conscientes de las limitaciones terapéuticas ante los depósitos de Candidade las prótesis. En algunos casos puede estar indicada la sustitución de la prótesis por una nueva.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La prótesis maxilofacial comprende aquellos dispositivos artificiales que restauran una parte ausente de la cara, debido a tumores, traumatismos, o como resultado de una anomalía congénita. El objetivo de este artículo es la exposición de un caso clínico que precisaba la confección de una prótesis óculo-palpebral tras sufrir una pérdida de sustancia por causa oncológica. Este tipo de prótesis son de las más difíciles de elaborar con buenos resultados pues intentan reconstruir un órgano móvil con una prótesis estática. La prótesis maxilofacial tiene la finalidad de aumentar la calidad de vida del paciente y ayudar a la seguridad emocional de los mismos, quedando así rehabilitados para poder integrarse nuevamente en la sociedad.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The overeruption of upper molars due to the premature loss of antagonist teeth can be treated with the help of miniscrews. The aim of this study was to evaluate the movement of a typodont molar according to the biomechanical approach used with miniscrews. Study design: The study was conducted with four plaster models filled with typodont wax. In each model we used one absolute anchorage on the palatal side and another on the buccal side in different positions, thus generating four different biomechanical systems. A force of 150 g was applied to each side of the resin tooth. Periapical radiographs were taken preintrusion and immediately after completion of the intrusion. Photographs were taken in both the sagittal and occlusal planes every 3 min. The radiographic films and photographs were measured and compared. Results: A vertical movement of the molar was observed in all the models, with system 4 showing the greatest movement. Rotation in the occlusal plane only occurred in system 2, while in system 1 there was a change in the axial axis of 37 degrees. Conclusions: The anchorage site and the combination of forces applied may determine the resulting tooth movement

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nous avons fait un examen clinique de 30 cas de contention postorthodontique avec attelle rigide en résine, de canine à canine sur les deux maxillaires. On décrit la fabrication de l'attelle, sa mise en place, les incidents possibles ou les problèmes cliniques apparus (mauvaise adhérence, gingivite ...) et les aspects psychologiques ou subjectifs du patient

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The attachment of Escherichia coli ATCC 25922 and Staphylococcus aureus ATCC 28213 onto six different materials used to manufacture dental implant abutments was quantitatively determined after 2 and 24 h of contact between the materials and the bacterial cultures. The materials were topographically characterized and their wettability determined, with both parameters subsequently related to bacterial adhesion. Atomic force microscopy, interferometry, and contact angle measurement were used to characterize the materials" surfaces. The results showed that neither roughness nor nano-roughness greatly influenced bacterial attachment whereas wettability strongly correlated with adhesion. After 2 h the degree of E. coli attachment markedly differed depending on the material whereas similar differences were not observed for S. aureus, which yielded consistently higher counts of adhered cells. Nevertheless, after 24 h the adhesion of the two species to the different test materials no longer significantly differed, although on all surfaces the numbers of finally adhered E. coli were higher than those of S. aureus

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. All cases were planned and operated upon with the guided surgery technique. Results: A total of 122 implants were placed in 14 males and 5 females. The intraoperative surgical complications comprised a lack of primary stability, while the postoperative complications consisted of infections and a lack of implant osteointegration. Ten implants failed. The prosthetic complications in turn comprised loosening of the provisional prosthesis screws, prosthesis tooth fracture, and a lack of passive fit of the immediate prosthesis. The degree of patient satisfaction was evaluated using a verbal scale. Conclusions: Implant restoration with the guided surgery technique and immediate functional loading is a predictable procedure, provided patient selection and the surgical technique are adequate, affording lesser postoperative morbidity and increased patient satisfaction thanks to the immediate restoration of esthetics and function

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. Study design: Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA)(impacted and threaded, respectively), a machined titanium surface implant (TI mach), a titanium plasma spray surface implant (TPS), and a sandblasted, acid-etched surface implant (SBAE). A 0.5-mm diameter bone defect was made in the implant apical zone, and a type-K thermocouple (Termopar)® was placed in contact with the implant. The implants were irradiated in the coronal zone of each implant with a CO2 (4 W continuous mode) and an ErCr:YSGG laser (1.5 W, pulsed mode) first without and then with refrigeration. The temperature variations at the implant apical surface were recorded. Results: An apical temperature increase was recorded in all cases during CO2 and ErCr:YSGG laser irradiation without refrigeration. However, when the ErCr:YSGG was used with a water spray, a decrease in temperature was observed in all implants. The acid-etched and sandblasted surfaces were those most affected by the thermal changes. Conclusions: The ErCr:YSGG laser with a water spray applied to the sealing cap or coronal zone of the implants does not generate thermal increments in the apical surface capable of adversely affecting osseointegration and the integrity of the peri-implant bone tissue

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Moebius syndrome is a rare congenital disorder characterized by unilateral or bilateral involvement of the sixth and seventh cranial nerves, resulting in a lack of facial expression and eye movements. These patients suffer a series of oral manifestations that may complicate their dental treatment, such as facial and tongue muscle weakness, uncontrolled salivation secondary to defi cient lip sealing, micrognathia, microstomia, bifi d uvula, gothic and fi ssured palate, fi ssured tongue, and glossoptosis. The underlying etiology remains unclear, though vascular problems during embryogenesis appear to be involved. Clinical case: We report the case of a woman with Moebius syndrome and total edentulism. Eight years ago she underwent complete oral rehabilitation with the placement of two implants in each dental arch. Discussion: Moebius syndrome has still an unknown etiology, although it is related to disorders during pregnancy. This kind of patient can be rehabilitated using oral implants.