13 resultados para Cobalt, Zinc

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Projecte de recerca elaborat a partir duna estada a la universitat d'Udine, Itlia, entre setembre i desembre del 2006.S'han caracteritzat mitjanant la reducci a temperatura programada i tests cataltics catalitzadors en pols basats en cobalt i supostats en xid de zinc i monlits cermics funcionaliltzats tamb amb cobalt i xid de zinc. L'addici de promotors (mangans, crom i ferro ) als catalitzadors en pols, preparats per impregnaci i precipitaci, no afecta significativament ni la temperatura a la qual t lloc la reducci ni al percentatge global de reducci. En els cicles de reducci-oxidaci s que s'observen diferncies entre el primer perfil de reducci i els segents, especialment en el cas de la mostra que t ferro com a promotor, on les diferncies s'accentuen en cicles successius (fins al quart). S'ha evaluat l'activitat d'aquests catalitzadors en la reacci de desplaament de gas d'aigua, obtenint uns resultats satisfactoris. Finalment s'han realitzat reduccions a temperatura programada i tests cataltics en la reacci de desplaament de gas d'aigua amb monlits funcionalitzats amb cobalt i xid de zinc (en cap d'ells s'ha introdut promotors). El nivell de conversi assolit s menor que en el cas de catalitzadors en pols, fet que s'associa a la geometria d'aquests sistemes cataltics, per la relaci CH4/CO2 s ms favorable que en els catalitzadors en pols, el que els converteix en sistemes molt selectius.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lobjectiu daquest projecte s sintetitzar i caracteritzar nanopartcules dxid de cobalt. Ens interessa estudiar diferents isomorfes de monxid de cobalt (CoO) ja que sn materials nous i sen desconeixen les propietats; en algunes investigacions sintueix un comportament antiferromagntic la qual cosa les fa especialment interessants per aplicacions magntiques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis of spinel ferrites with composition Zn1-2xNaxFe2+xO4has been performed and the composition range in which single phase samples are obtained has been defined. The characterization of the samples has been carried out from atomic absorption and X-ray fluorescence analyses, X-ray diffraction patterns, Mssbauer spectroscopy and thermomagnetic measurements. It is show that significant loss of Na does exist when the synthesis is performed at high temperatures. When the Na volatilization is avoided spinel oxides with Na content up to 0.25 atoms per unit formula can be obtained. In this case the increase of the interatomic distances leads to differing fundamental magnetic properties as compared to the equivalent lithium-zinc ferrites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, zinc indium tin oxide layers with different compositions are used as the active layer of thin film transistors. This multicomponent transparent conductive oxide is gaining great interest due to its reduced content of the scarce indium element. Experimental data indicate that the incorporation of zinc promotes the creation of oxygen vacancies. In thin-film transistors this effect leads to a higher threshold voltage values. The field-effect mobility is also strongly degraded, probably due to coulomb scattering by ionized defects. A post deposition annealing in air reduces the density of oxygen vacancies and improves the fieldeffect mobility by orders of magnitude. Finally, the electrical characteristics of the fabricated thin-film transistors have been analyzed to estimate the density of states in the gap of the active layers. These measurements reveal a clear peak located at 0.3 eV from the conduction band edge that could be attributed to oxygen vacancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the alterations in plasma, liver, and meat oxidative stability and R-tocopherol content when moderately oxidized sunflower oils were added to feeds and when feeds were supplemented with R-tocopheryl acetate (100 mg/kg) and Zn (200 mg/kg). The effects of cooking the meat and its subsequent refrigeration were also studied. When the content of primary oxidation compounds of the oil was high, rabbit plasma, liver, and meat R-tocopherol content was reduced and meat susceptibility to oxidation increased. The addition of oil with a high content of secondary oxidation compounds (oil heated at 140 'C, 31 h) to feed also led to an increase in meat susceptibi- lity to oxidation, although it presented an R-tocopherol content similar to that of nonheated oil. Feed supplementation with R-tocopheryl acetate increased tissue R-tocopherol content and improved the oxidative stability of liver and meat. However, in the latter, it was less effective when oil heated at 55 'C was added.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, zinc indium tin oxide layers with different compositions are used as the active layer of thin film transistors. This multicomponent transparent conductive oxide is gaining great interest due to its reduced content of the scarce indium element. Experimental data indicate that the incorporation of zinc promotes the creation of oxygen vacancies. In thin-film transistors this effect leads to a higher threshold voltage values. The field-effect mobility is also strongly degraded, probably due to coulomb scattering by ionized defects. A post deposition annealing in air reduces the density of oxygen vacancies and improves the fieldeffect mobility by orders of magnitude. Finally, the electrical characteristics of the fabricated thin-film transistors have been analyzed to estimate the density of states in the gap of the active layers. These measurements reveal a clear peak located at 0.3 eV from the conduction band edge that could be attributed to oxygen vacancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural and optical properties of three different kinds of GaAs nanowires with 100% zinc-blende structure and with an average of 30% and 70% wurtzite are presented. A variety of shorter and longer segments of zinc-blende or wurtzite crystal phases are observed by transmission electron microscopy in the nanowires. Sharp photoluminescence lines are observed with emission energies tuned from 1.515 eV down to 1.43 eV when the percentage of wurtzite is increased. The downward shift of the emission peaks can be understood by carrier confinement at the interfaces, in quantum wells and in random short period superlattices existent in these nanowires, assuming a staggered band offset between wurtzite and zinc-blende GaAs. The latter is confirmed also by time-resolved measurements. The extremely local nature of these optical transitions is evidenced also by cathodoluminescence measurements. Raman spectroscopy on single wires shows different strain conditions, depending on the wurtzite content which affects also the band alignments. Finally, the occurrence of the two crystallographic phases is discussed in thermodynamic terms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the addition of heated oils to feeds (3%, w/w) and the dietary supplementation with a-tocopheryl acetate (TA; 100 mg/kg) and Zn (200 mg/kg) on rabbit tissue fatty acid (FA) composition and on the Zn, Cu, Fe and Se content in meat were assessed. Heating unrened sunower oil (SO) at 558C for 245 h increased its content in primary oxidation products and reduced its a-tocopherol content. However, this did not signicantly affect tissue FA composition. Heating SO at 1408C for 31 h increased its content in secondary oxidation products and in some FA isomers asc9,t11-CLA and di-trans CLA. This led to increases in di-trans CLA in liver and in t9,c12-18:2 in meat. The c9,t11-CLA was the most incorporated CLA isomer in tissues. The dietary supplementation with a-TA did not affect the FA composition of plasma, liver or meat. The cooking of vacuum-packed rabbit meat at 788C for 5 min reduced signicantly but slightly its polyunsaturated FA content. The dietary supplementation with Zn did not modify the content of Zn, Fe or Se in meat, but it reduced its Cu content. On the other hand, it increased the content of some FAs in meat when SO heated at 1408C for 31 h was added to feeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zinc indium tin oxide (ZITO) transparent conductive oxide layers were deposited via radio frequency (RF) magnetron co-sputtering at room temperature. A series of samples with gradually varying zinc content was investigated. The samples were characterized with x-ray and ultraviolet photoemission spectroscopy (XPS, UPS) to determine the electronic structure of the surface. Valence and conduction bands maxima (VBM, CBM), and work function were determined. The experiments indicate that increasing Zn content results in films with a higher defect rate at the surface leading to the formation of a degenerately doped surface layer if the Zn content surpasses 50%. Furthermore, the experiments demonstrate that ZITO is susceptible to ultraviolet light induced work function reduction, similar to what was earlier observed on ITO and TiO2 films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se presenta un nuevo caso de Acrodermatitis Enteroptica en un lactante de 2,5 meses de vida, fruto de embarazo gemelar bivitelino pretrmino (36 S), de aparicin gradual desde los 15 das de vida. Haba seguido lactancia artificial exclusivamente desde su nacimiento, al igual que su hermano gemelo que no present la enfermedad. Entre los exmenes complementarios destacaba una importante hipozincemia, fosfatasas alcalinas descendidas, alteraciones en la inmunidad celular, rasgos de inmadurez cerebral en el EEG y discreta atrofia vellositaria en la muestra bipsica intestinal. El Tratamiento con sulfato de Zinc a la dosis de 10 mg/Kg/da hizo remitir el cuadro clnico y analtico en pocos das. A los 4 meses de edad abandon el tratamiento, reapareciendo a los 22 das los sntomas digestivos y cutneos; la zincemia en ese momento era elevada (175 mcg/dl). Esta falta de relacin entre la zincemia y la clnica sugiere que en la Acrodermatitis Enteroptica el defecto de transporte del Zn afecta no slo al enterocito sino tambin a otras clulas del organismo y que el criterio para mantener el tratamiento y fijar la dosis debe ser clnico y no analtico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.