101 resultados para Tear film stability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogenated microcrystalline silicon films obtained at low temperature (150-280°C) by hot wire chemical vapour deposition at two different process pressures were measured by Raman spectroscopy, X-ray diffraction (XRD) spectroscopy and photothermal deflection spectroscopy (PDS). A crystalline fraction >90% with a subgap optical absortion 10 cm -1 at 0.8 eV were obtained in films deposited at growth rates >0.8 nm/s. These films were incorporated in n-channel thin film transistors and their electrical properties were measured. The saturation mobility was 0.72 ± 0.05 cm 2/ V s and the threshold voltage around 0.2 eV. The dependence of their conductance activation energies on gate voltages were related to the properties of the material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen vacancies in metal oxides are known to determine their chemistry and physics. The properties of neutral oxygen vacancies in metal oxides of increasing complexity (MgO, CaO, alpha-Al2O3, and ZnO) have been studied using density functional theory. Vacancy formation energies, vacancy-vacancy interaction, and the barriers for vacancy migration are determined and rationalized in terms of the ionicity, the Madelung potential, and lattice relaxation. It is found that the Madelung potential controls the oxygen vacancy properties of highly ionic oxides whereas a more complex picture arises for covalent ZnO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Personalized medicine is a challenging research area in paediatric treatments. Elaborating new paediatric formulations when no commercial forms are available is a common practice in pharmacy laboratories; among these, oral liquid formulations are the most common. But due to the lack of specialized equipment, frequently studies to assure the efficiency and safety of the final medicine cannot be carried out. Thus the purpose of this work was the development, characterization and stability evaluation of two oral formulations of sildenafil for the treatment of neonatal persistent pulmonary hypertension. After the establishment of a standard operating procedure (SOP) and elaboration, the physicochemical stability parameters appearance, pH, particle size, rheological behaviour and drug content of formulations were evaluated at three different temperatures for 90 days. Equally, prediction of long term stability, as well as, microbiological stability was performed. Formulations resulted in a suspension and a solution slightly coloured exhibiting fruity odour. Formulation I (suspension) exhibited the best physicochemical properties including Newtonian behaviour and uniformity of API content above 90% to assure an exact dosification process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissolution studies have become of great significance because, in most cases, drug dissolution is the rate-limiting step in the absorption process. As occurs with solid oral dosage forms, heterogeneous disperse systems (suspensions) could also have some problems with their in vitro dissolution. The objective of this study was to evaluate influence of the excipients on the release of spironolactone from four alcohol free suspensions (pharmaceutical compounding) of spironolactone 5 mg/mL suitable for pediatric use. Also the comparison of the physical and chemical stability of the suspensions stored at 4, 25 and 40 ºC over a 60- day period has been studied. Rheological behavior, particle size, a prediction of long-term physical stability, pH and assay of spironolactone by HPLC were assessed at prefixed times. The dissolution profile of each suspension was determined and compared with that of the commercial tablets. A microbiological study of the best formula was also performed. Chemically, the four spironolactone suspensions were stable for 60 days stored at three temperatures; Suspension IV had optimum pH values and the highest recovery percentage. In terms of physical stability, sedimentation occurred in Suspension IV and flotation of spironolactone in Suspensions I, II and III. Suspension III had the highest viscosity and the slowest drug release. Suspension IV was also microbiologically stable for 60 days. In conclusion, Suspension IV had the best properties and the least suitable form was Suspension III, as its high viscosity made it difficult to achieve homogeneous redispersion, and it had the slowest dissolution profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation argues that the Government of the People’s Republic of China, when it made the decision to import a quota of Hollywood films in 1994 to revive the failing domestic film industry, had different possible criteria in mind. This project has studied four of them: first, importing films that gave a negative image of the United States; second, importing films that featured Chinese talent or themes; third, importing films that were box office hits in the United States; and fourth, importing films with a strong technological innovation ingredient. In order to find out the most important criteria for the Chinese Government, this dissertation offers a dataset that analyzes a population of 262 Hollywood films released in the PRC between 1994 and 2010. For each unit, a method has been developed to compile data that will determine whether the film reflects any of the four criteria, and findings in the form of yearly percentages have been drawn. Results show that, out of the four studied criteria, the two predominant reasons for China to import films were technological innovation and box office hits. This tells us that, at this point, the Chinese Government shows more interest in obtaining big revenues and learning from technically innovative American films than in delivering underlying political messages. This dissertation contributes to the existing literature by analyzing the content of all the films imported by China between 1994 and 2010, while integrating in the analysis variables based on the existing knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to define a new statistic, PVL, based on the relative distance between the likelihood associated with the simulation replications and the likelihood of the conceptual model. Our results coming from several simulation experiments of a clinical trial show that the PVL statistic range can be a good measure of stability to establish when a computational model verifies the underlying conceptual model. PVL improves also the analysis of simulation replications because only one statistic is associated with all the simulation replications. As well it presents several verification scenarios, obtained by altering the simulation model, that show the usefulness of PVL. Further simulation experiments suggest that a 0 to 20 % range may define adequate limits for the verification problem, if considered from the viewpoint of an equivalence test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The degradation of the filaments is usually studied by checking the silicidation or carbonization status of the refractory metal used as catalysts, and their effects on the structural stability of the filaments. In this paper, it will be shown that the catalytic stability of a filament heated at high temperature is much shorter than its structural lifetime. The electrical resistance of a thin tungsten filament and the deposition rate of the deposited thin film have been monitored during the filament aging. It has been found that the deposition rate drops drastically once the quantity of dissolved silicon in the tungsten reaches the solubility limit and the silicides start precipitating. This manuscript concludes that the catalytic stability is only guaranteed for a short time and that for sufficiently thick filaments it does not depend on the filament radius.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Personalized medicine is a challenging research area in paediatric treatments. Elaborating new paediatric formulations when no commercial forms are available is a common practice in pharmacy laboratories; among these, oral liquid formulations are the most common. But due to the lack of specialized equipment, frequently studies to assure the efficiency and safety of the final medicine cannot be carried out. Thus the purpose of this work was the development, characterization and stability evaluation of two oral formulations of sildenafil for the treatment of neonatal persistent pulmonary hypertension. After the establishment of a standard operating procedure (SOP) and elaboration, the physicochemical stability parameters appearance, pH, particle size, rheological behaviour and drug content of formulations were evaluated at three different temperatures for 90 days. Equally, prediction of long term stability, as well as, microbiological stability was performed. Formulations resulted in a suspension and a solution slightly coloured exhibiting fruity odour. Formulation I (suspension) exhibited the best physicochemical properties including Newtonian behaviour and uniformity of API content above 90% to assure an exact dosification process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article contributes to the study of cinema audiences in Europe by analyzing theactual behavior of Spanish moviegoers and their level of satisfaction. We modeledmoviegoers’ choice of film by country of origin (U.S.A., Spain, and other countries)according to a set of determinants: (1) consumers’ interpretation of several sources of information, (2) motivations and (3) choice rules. We found three clear consumerstereotypes related to each type of film: (1) U.S.A. films were preferred by almost everyone (especially families and younger audiences); (2) Spanish films had audiences composed of middle-age and middle-class moviegoers; and (3) European productions were preferred by a social or intellectual elite. U.S.A. films dominate the Spanish market for the reason that they provide most of what moviegoers prefer, namely, familiar, reliable entertainment in Spanish; three characteristics that are not satisfied by Spanish and European films. Additionally, we discuss the implications for the European cultural policy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of ionic liquid analogues as solvents has increased in order to substitute the aqueous solvents in some applications in which the side reactions are undesirable. However these solvents prepared from the mixture in the eutectic proportion of species establishing hydrogen bonds are susceptible of electrochemical reactions. The study of platinum deposition on vitreous carbon in an ionic liquid analogue (2 urea: choli ne chloride) is presented; the electrochemical study has permitted to interpret the sequence of the metal deposition process and simultaneously to analyze the behavior of the ionic liquid analogue along the process. Reduction reactions of the solvent relat ed both to the electronation of choline and hydrogen formation have been detected. Different substrata have been used in order to test the possibility and the extent of these reactions depending on the nature of material. The results indicate that the feas ible electrochemical window of the substrate/solvent is highly dependent of the kind of substrate; the negative limit is tied by the massive hydrogen reaction, reaction enhanced by the electrocatalytic character of the substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method