28 resultados para sensors mota
Resumo:
Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.
Resumo:
Treball de recerca realitzat per alumnes d’ensenyament secundari i guardonat amb un Premi CIRIT per fomentar l'esperit científic del Jovent l’any 2010. L’objectiu principal d'aquest treball és analitzar i quantificar la relació i influència que podria existir entre alguns paràmetres que defineixen les condicions meteorològiques i l'estat de maduració del raïm en les setmanes prèvies a la verema. En la part introductòria s'estableixen els fonaments biològics i tecnològics, per donar pas a la secció on es duu a terme la implantació tecnològica, i s'explica la metodologia experimental i analítica seguides, per donar lloc a l'anàlisi, estudi i valoració dels resultats obtinguts. En el fons, i al llarg de tot el treball de recerca, es pretén que el lector encuriosit es vegi motivat per extreure les seves pròpies deduccions, conclusions i formular els seus propis dubtes sobre els procediments que es descriuen, així com els resultats finals. S'ha pogut establir a partir dels resultats empírics una equació matemàtica entre l'increment de la concentració dels sucres del raïm (factor principal en la seva maduració) i el nombre d'hores de Sol acumulades.
Resumo:
This poster shows how to efficiently observe high-frequency figures of merit in RF circuits by measuring DC temperature with CMOS-compatible built-in sensors.
Resumo:
L’Slot, conegut per tots amb el nom d’Scalextric, s’ha implantat com a una forma d’oci habitual, la pràctica del qual no queda restringida als més petits, sinó que cada vegada crea més afició entre els grans. El fet que l’Slot s’hagi extès entre els adults n’ha revolucionat la pràctica. L’entrada al mercat de l’Slot de gent adulta, i amb poder adquisitiu molt superior als adolescents, ha provocat que les marques especialitzades vagin evolucionant els seus productes cada vegada més. Totes les marques s’han vist obligades a desenvolupar vehicles més competitius i alhora treure al mercat accessoris que augmentin la realitat del joc. Una de les necessitats que s’ha creat és la de competir entre jugadors. Aquesta competició tan pot ser en forma de carrera entre diversos participants, com de forma individual, cronometrant el temps de cada participant en un circuit. L’objectiu principal del projecte és crear un sistema capaç de realitzar cronometratges en temps real mitjançant sensors digitals ja existents en el mercat de l’Slot i poder controlar i visualitzar la informació des d’un PC. Per a poder captar els senyals dels sensors s’ha utilitzat un sistema microcontrolat, que garanteix gran velocitat d’adquisició, processament de dades i transmissió. La comunicació del Microcontrolador amb el PC s’ha realizat mitjançant el bus USB. El PC serà el controlador del sistema i donarà les ordres al Microcontrolador, podent així tenir control total sobre el funcionament del programa. També serà el PC el que tractarà els crocometratges enregistrats i els mostrarà per pantalla
Resumo:
Amb el present projecte es proposa fer un estudi de la web semàntica aplicada a la descripció i modelització de la instrumentació marina operada en el context de campanyes d'investigació oceanogràfica.
Resumo:
Nanocrystalline TiO2 modified with Nb has been produced through the sol-gel technique. Nanopowders have been obtained by means of the hydrolysis of pure alkoxides with deionized water and peptization of the resulting hydrolysate with diluted acid nitric at 100 C. The addition of Nb stabilizes the anatase phase to higher temperatures. XRD spectra of the undoped and the Nb-doped samples show that the undoped sample has been almost totally converted to rutile at 600 C, meanwhile the doped samples present still a low percentage of rutile phase. Nanocrystalline powders stabilized at 600 C with grain sizes of about 17 nm have successfully been synthesized by the addition of Nb with a concentration of 2% at., which appears to be an adequate additive concentration to improve the gas sensor performances, such as it is suggested by the catalytic conversion efficiency experiments performed from FTIR measurements. FTIR absorbance spectra show that catalytic conversion of CO occurs at lower temperatures when niobium is introduced. The electrical response of the films to different concentrations of CO and ethanol has been monitored in dry and wet environments in order to test the influence of humidity in the sensor response. The addition of Nb decreases the working temperature and increases the stability of the layers. Also, large enhancement of the response time is obtained even with lower working temperatures. Moreover, humidity effects on the gas sensor response toward CO and ethanol are less important in Nb-doped samples than in the undoped ones.
Resumo:
Nanocrystalline TiO2 modified with Nb has been produced through the sol-gel technique. Nanopowders have been obtained by means of the hydrolysis of pure alkoxides with deionized water and peptization of the resulting hydrolysate with diluted acid nitric at 100 C. The addition of Nb stabilizes the anatase phase to higher temperatures. XRD spectra of the undoped and the Nb-doped samples show that the undoped sample has been almost totally converted to rutile at 600 C, meanwhile the doped samples present still a low percentage of rutile phase. Nanocrystalline powders stabilized at 600 C with grain sizes of about 17 nm have successfully been synthesized by the addition of Nb with a concentration of 2% at., which appears to be an adequate additive concentration to improve the gas sensor performances, such as it is suggested by the catalytic conversion efficiency experiments performed from FTIR measurements. FTIR absorbance spectra show that catalytic conversion of CO occurs at lower temperatures when niobium is introduced. The electrical response of the films to different concentrations of CO and ethanol has been monitored in dry and wet environments in order to test the influence of humidity in the sensor response. The addition of Nb decreases the working temperature and increases the stability of the layers. Also, large enhancement of the response time is obtained even with lower working temperatures. Moreover, humidity effects on the gas sensor response toward CO and ethanol are less important in Nb-doped samples than in the undoped ones.
Resumo:
The paper analyses and compares infrasonic and seismic data from snow avalanches monitored at the Vallée de la Sionne test site in Switzerland from 2009 to 2010. Using a combination of seismic and infrasound sensors, it is possible not only to detect a snow avalanche but also to distinguish between the different flow regimes and to analyse duration, average speed (for sections of the avalanche path) and avalanche size. Different sensitiveness of the seismic and infrasound sensors to the avalanche regimes is shown. Furthermore, the high amplitudes observed in the infrasound signal for one avalanche were modelled assuming that the suspension layer of the avalanche acts as a moving turbulent sound source. Our results show reproducibility for similar avalanches on the same avalanche path.
Resumo:
Trabajo de final de carrera enfocado a la simulacion de una WSN (Wireless Sensors Networks) mediante el programa Contiki 2.7 y el SO Ubuntu. La idea global del proyecto es conseguir simular un entorno con nodos sensores, y a posteriori comprobar su correcto funcionamiento en motas reales. Comprobando los resultados obtenidos en ambos entornos. De esta manera se puede facilitar la puesta en marcha de este tipo de redes inalámbricas en una aplicación real.
Resumo:
Canopy characterization is a key factor to improve pesticide application methods in tree crops and vineyards. Development of quick, easy and efficient methods to determine the fundamental parameters used to characterize canopy structure is thus an important need. In this research the use of ultrasonic and LIDAR sensors have been compared with the traditional manual and destructive canopy measurement procedure. For both methods the values of key parameters such as crop height, crop width, crop volume or leaf area have been compared. Obtained results indicate that an ultrasonic sensor is an appropriate tool to determine the average canopy characteristics, while a LIDAR sensor provides more accuracy and detailed information about the canopy. Good correlations have been obtained between crop volume (CVU) values measured with ultrasonic sensors and leaf area index, LAI (R2 = 0.51). A good correlation has also been obtained between the canopy volume measured with ultrasonic and LIDAR sensors (R2 = 0.52). Laser measurements of crop height (CHL) allow one to accurately predict the canopy volume. The proposed new technologies seems very appropriate as complementary tools to improve the efficiency of pesticide applications, although further improvements are still needed.
Resumo:
En este trabajo se presenta un estudio químico y estructural de las capas metálicas de Pt y TaSix utilizadas como puerta catalítica en sensores de gas de alta temperatura basados en dispositivos MOS de SiC. Para ello se han depositado capas de diferentes espesores sobre substratos de Si. Los resultados muestran que con la reducción del espesor de Pt y con un recocido se consigue aumentar la rugosidad de las capas de puerta, lo que debería aumentar la sensibilidad y la velocidad de respuesta de los dispositivos que las incorporasen. Otro efecto del recocido es la transformación química del material de la puerta que, para capas delgadas de Pt con TaSix, produce la transformación total Pt en Pt2Ta, lo que podría afectar a las características catalíticas de la puerta. Los primeros resultados eléctricos indican que, a pesar de que las capas de Pt empleadas son gruesas y compactas, los diodos MOS túnel de SiC son sensibles a los gases CO y NO2, aunque presentan una velocidad de respuesta bastante lenta.
Resumo:
This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.
Resumo:
L’Slot, conegut per tots amb el nom d’Scalextric, s’ha implantat com a una forma d’oci habitual, la pràctica del qual no queda restringida als més petits, sinó que cada vegada crea més afició entre els grans. El fet que l’Slot s’hagi extès entre els adults n’ha revolucionat la pràctica. L’entrada al mercat de l’Slot de gent adulta, i amb poder adquisitiu molt superior als adolescents, ha provocat que les marques especialitzades vagin evolucionant els seus productes cada vegada més. Totes les marques s’han vist obligades a desenvolupar vehicles més competitius i alhora treure al mercat accessoris que augmentin la realitat del joc. Una de les necessitats que s’ha creat és la de competir entre jugadors. Aquesta competició tan pot ser en forma de carrera entre diversos participants, com de forma individual, cronometrant el temps de cada participant en un circuit. L’objectiu principal del projecte és crear un sistema capaç de realitzar cronometratges en temps real mitjançant sensors digitals ja existents en el mercat de l’Slot i poder controlar i visualitzar la informació des d’un PC. Per a poder captar els senyals dels sensors s’ha utilitzat un sistema microcontrolat, que garanteix gran velocitat d’adquisició, processament de dades i transmissió. La comunicació del Microcontrolador amb el PC s’ha realizat mitjançant el bus USB. El PC serà el controlador del sistema i donarà les ordres al Microcontrolador, podent així tenir control total sobre el funcionament del programa. També serà el PC el que tractarà els crocometratges enregistrats i els mostrarà per pantalla