6 resultados para design III
Resumo:
Overview and Aims: Female sterilization is increasingly requested as a contraceptive method. Hysteroscopic sterilization by transcervical placing of Essure® micro-inserts in the initial portion of the tubes is a recent alternative to laparoscopic sterilization. The objective of this study is to evaluate the safety and effectiveness of hysteroscopic versus laparoscopic sterilization. Study Design: Retrospective cohort study. Population: A total of 98 women undergoing sterilization in an outpatient clinic between July 2005 and July 2009. Methods: Patients’ age, associated diseases, anesthesic risk, procedure time, discomfort, adverse events and success rate were evaluated. Results: Mean age at surgery was 37.8 years (19-49), and there were no statistically significant differences between the groups regarding this parameter. Women in the hysteroscopic group had a significant number of associated diseases (98% versus 47%), obesity (31% versus 6%), and anesthesic risk (ASA III- 31% versus 0%). The mean duration of the procedure was the same for both techniques (laparoscopy 28 minutes and hysteroscopy 26 minutes). All laparoscopic sterilizations were successfully completed. In the hysteroscopic group 4% failed to complete the technique. There were no cases of severe pain. Women in the hysteroscopy group reported pain less frequently (40% versus 57%, χ2 p<0.05). Long term success rate was similar in both groups (96% for hysteroscopy and 98% for laparoscopy). Conclusions: In spite of a higher incidence of associated diseases, obesity and anesthetic risks in the hysteroscopy group, there were no significant differences in the duration of the procedure, adverse events and success rate. The hysteroscopic approach can therefore be considered an alternative to laparoscopy, eliminating the need for incisional surgery and for general anaesthesia. If women with high surgical risk and several associated diseases can safely undergo this procedure, it could well become the preferred method for women who want a permanent and irreversible contraceptive method.
Resumo:
OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.
Resumo:
Objective: To investigate the results of vaginal obliterate surgery in elderly women with pelvic organ prolapse. Design: observational retrospective study. Material and Methods: a total of 69 women with the diagnosis of pelvic prolapse were submitted to obliterative surgery in the urogynecology unit of a tertiary care hospital centre over the course of 8 years (2001 to 2008). The following data were collected from their clinical records: age, number of vaginal births, body mass index (BMI), hormone therapy, other existing diseases, type of prolapse and stage, anaesthetic risk score, duration of surgery, length of hospital stay, and short-term complications. Results: Of the 69 women studied, 31 were submitted to colpocleisis and the remaining 38 were managed by the LeFort technique. Mean age was 74.8 years with a standard deviation (sd) of 7.14 years. Average BMI was 26.2 (sd =3.76). Vaginal births were recorded in all patients. Only three patients were taking hormone therapy at the time of surgery. Sixty-three women were classified as having and anesthetic risk of II or III and 55 underwent local-regional anesthesia. Complications were reported in five cases, four of which in the first days after surgery. Nearly all were mild and resolved within the first 6 weeks. Conclusion: Complication rates appear to be low after obliterative surgery for pelvic organ prolapse in elderly women.
Resumo:
A deficiência congénita de anti-trombina III é considerada como um estado de hipercoagulabilidade primária. Os autores apresentam um caso de deficiência de anti-trombina III num jovem do sexo masculino, de 28 anos de idade, com doença valvular aórtica e múltiplos episódios de fenómenos tromboembólicos. Ao discutirem os seus aspectos diagnósticos e terapêuticos, procuram sensibilizar para a necessidade de se rastrear situações de trombofilia em doentes com fenómenos trombóticos recorrentes.
Resumo:
Objective To study the incidence, clinical presentation, risk factors, imaging diagnosis, and clinical outcome of perinatal stroke. Methods Data was retrospectively collected from full-term newborns admitted to the neonatal unit of a level III maternity in Lisbon with cerebral stroke, from January 2007 to December 2011. Results There were 11 cases of stroke: nine were arterial ischemic stroke and two were cerebral venous sinus thrombosis. We estimated an incidence of arterial ischemic stroke of 1.6/5,000 births and of cerebral venous sinus thrombosis of 7.2/100,000 births. There were two cases of recurrent stroke. Eight patients presented with symptoms while the remaining three were asymptomatic and incidentally diagnosed. The most frequently registered symptoms (8/11) were seizures; in that, generalized clonic (3/8) and focal clonic (5/8). Strokes were more commonly left-sided (9/11), and the most affected artery was the left middle cerebral artery (8/11). Transfontanelle ultrasound was positive in most of the patients (10/11), and stroke was confirmed by cerebral magnetic resonance in all patients. Electroencephalographic recordings were carried out in five patients and were abnormal in three (focal abnormalities n=2, burst-suppression pattern n=1). Eight patients had previously identified risk factors for neonatal stroke which included obstetric and neonatal causes. Ten patients were followed up at outpatients setting; four patients developed motor deficits and one presented with epilepsy. Conclusions Although a modest and heterogeneous sample, this study emphasizes the need for a high level of suspicion when it comes to neonatal stroke, primarily in the presence of risk factors. The prevalence of neurological sequelae in our series supports the need of long-term follow-up and early intervention strategies.
Resumo:
INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.