23 resultados para bio-optical


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Engenharia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Faculdade de Ciências e Tecnologia – Universidade Nova de Lisboa Departamento de Engenharia Electrotécnica Tese de mestrado

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnetostratigraphy of two sections in early Miocene marine deposits of the Tagus Basin is studied. Thermal demagnetization was used to isolate the primary component of magnetization for 45 samples from the Foz da Fonte section, and for 74 others from Trafaria section. The succession of the polarity zones found in these sections is tentatively correlated with the geomagnetic polarity time scale (GPTS) on the basis of the biostratigraphic data yielded by planktic Foraminifera. The planktic zones and magnetic polarities recognized in these sections can be adequately correlated with the part of the GPTS [table calibrated by BERGGRENET al. (1985)] corresponding to the Anomalies 6 and 5E (Foz da Fonte) and 5D (Trafaria). This correlations suggests ages between 19,35 and 18,14 Ma for Foz da Fonte section, and 17,90 to 16,98 Ma for Trafaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil de Engenharia Ecológica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do grau de Doutor em Biotecnologia pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia. A presente dissertação foi preparada no âmbito do protocolo de acordo bilateral de educação avançada (ERASMUS) entre a Universidade de Vigo e a Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Energia e Bioenergia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Instrumentação, Manutenção Industrial e Qualidade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Ambiente, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada à Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia, para obtenção do Grau de Mestre em Energia e Bioenergia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctorate in Biology, Specialty in Biotechnology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação foca-se em métodos inovadores para a bio-secagem do Combustível Derivado de Resíduos (CDR) produzido na linha de Tratamento Mecânico de Biológico (TMB), na VALNOR SA. O CDR representa 25 a 35% dos resíduos indiferenciados tratados numa unidade de TMB e que resulta do refugo e rejeitados retirados na linha de triagem mecânica e no processo de afinação do composto orgânico. O CDR pode ser utilizado como combustível alternativo ao combustível fóssil em centrais de co-geração e/ou cimenteiras. No caso da indústria cimenteira, a secagem do CDR é fundamental (a humidade média é de 40 a 50% e, terá de se reduzir para 20% ou inferior) de modo a aumentar o seu Poder Calorífico Inferior (PCI), para maior eficiência energética no processo produtivo nos fornos do clínquer e dar cumprimento à redução de utilização dos combustíveis fósseis que a União Europeia pretende. Com este trabalho, contribuiu-se com mais um passo no sentido de se viabilizarem as melhores opções técnico-ambientais e económicas para se cumprirem os objetivos prioritários no domínio da valorização dos resíduos passando a ser um recurso ou produto. Com efeito a substituição do combustível fóssil por um combustível alternativo do tipo do CDR não só se traduz em benefícios ambientais, nomeadamente a redução de deposição em aterro, a redução das emissões de Gases com Efeito de Estufa (GEE) e o cumprimento dos objetivos e metas do Plano Estratégico para os Resíduos Sólidos Urbanos (PERSU) 2020, como também enquadra evidentes vantagens económicas enquanto recurso alternativo e minimiza o valor do instrumento financeiro da Taxa de Gestão de Resíduos (TGR) que se prevê aumentar significativamente até 2020 no que respeita à deposição de resíduos/refugos/rejeitados em aterro.