13 resultados para Trust unit
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação.
Resumo:
ABSTRACT: Tobacco use remains the most significant modifiable cause of disability, death and illness1. In Portugal, 19,6% of the population aged ten years or more smoke3. A Cochrane review of 20087 concluded that a brief advice intervention (compared to usual care) can increase the likelihood of a smoker to quit and remain nonsmoker 12 months later by a further 1 to 3 %. Several studies have shown that Primary Care Physicians can play a key role in these interventions8,9,10. However we did not find studies about the effectiveness of brief interventions in routine consultations of Family Doctors in Portugal. For this reason we designed a Cohort Study to make an exploratory study about the effectiveness of brief interventions of less than three minutes in comparison with usual care in routine consultations. The study will be implemented in a Family Healthcare Unit in Beja, during six months. Family Doctors of the intervention group should be submitted for an educational and training program before the study begin. Quit smoking sustained rates will be estimated one year after the first intervention in each smoker. If, as we expect, quit smoking rates will be higher in the intervention group than in the control group, this may change Portuguese Family Doctors attitudes and increase the provision of brief interventions in routine consultations in Primary Healthcare Centers.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Química e Bioquímica
Resumo:
In this work, a volumetric unit previously assembled by the research group was upgraded. This unit revamping was necessary due to the malfunction of the solenoid valves employed in the original experimental setup, which were not sealing the gas properly leading to erroneous adsorption equilibrium measurements. Therefore, the solenoid valves were substituted by manual ball valves. After the volumetric unit improvement its operation was validated. For this purpose, the adsorption equilibrium of carbon dioxide (CO2) at 323K and 0 - 20 bar was measured on two different activated carbon samples, in the of extrudates (ANG6) and of a honeycomb monolith (ACHM). The adsorption equilibrium results were compared with data previously measured by the research group, using a high-pressure microbalance from Rubotherm GmbH (Germany) – gravimetric. The results obtained using both apparatuses are coincident thus validating the good operation of the volumetric unit upgraded in this work. Furthermore, the adsorption equilibrium of CO2 at 303K and 0 - 10 bar on Metal-Organic Frameworks (MOFs) Cu-BTC and Fe-BTC was also studied. The CO2 adsorption equilibrium results for both MOFs were compared with the literature results showing good agreement, which confirms the good quality of the experimental results obtained in the new volumetric unit. Cu-BTC sample showed significantly higher CO2 adsorption capacity when compared with the Fe-BTC sample. The revamping of the volumetric unit included a new valve configuration in order to allow testing an alternative method for the measurement of adsorption equilibrium. This new method was employed to measure the adsorption equilibrium of CO2 on ANG6 and ACHM at 303, 323 and 353K within 0-10 bar. The good quality of the obtained experimental data was testified by comparison with data previously obtained by the research group in a gravimetric apparatus.
Resumo:
A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
In the fields of marketing and general management, many are the contributions of literature relating trust and e‐commerce. Trust is perceived as an issue that concerns the consumers’ intention to purchase. As so, in this research, a path model is empirically tested in order to develop solutions for Internet vendors on how to deal with consumers and increase their trust. The path model measures how the dimensions of trust, named as competence, integrity and benevolence positively influence the overall trust of the consumers and at the same time how the sources of trust – consumer characteristics, firm characteristics, website infrastructure and interactions influence those dimensions. The data used to test the model was collected in Portugal, through 365 valid cases. Findings revealed that consumers, which have high level of overall trust, are more likely to intent to purchase online.
Resumo:
Strategic alliances represent a key driver for internationalization and growth, being the purpose of this work project to better understand the intertwined relationship between trust and the existence of an alliance management position. Previous research supports the positive impact of such position in stock market returns. However, little attention has been given to the impact of such position on the level of trust in the collaborative arrangement, which is deemed to be a key driver for alliance success. A qualitative comparative case-study of three Portuguese SMEs is used to draw conclusions from the literature to real life business cases and it demonstrates the positive impact of an alliance management position on trust.
Resumo:
RESUMO - Introdução: Os critérios de adequação (Appropriate Use Criteria - AUC) em Ecocardiografia Transtorácica (ETT) foram publicados com o intuito de permitir o uso racional da ecocardiografia, de influenciar decisões clinicas, prestar cuidados de saúde de elevada qualidade e melhorar o outcome dos pacientes. A relação entre a adequação destes e o seu impacto clinico ainda não se encontra largamente estudada. Objectivo: Neste estudo pretendeu-se avaliar o grau de adesão aos AUC em ETT, em diferentes contextos de atendimento e de acordo com diferentes especialidades, bem como o impacto clínico do exame no outcome do paciente, num hospital público terciário no Reino Unido. Metodologia: 859 ETTs realizados consecutivamente no mês de Janeiro de 2014, foram revistos por forma a avaliar a sua adequação e foram classificados como adequados, incertos ou inadequados de acordo com as guidelines de 2011. De seguida os registos dos pacientes foram revistos com o intuito de avaliar o impacto clinico dos ETTs e foram classificados de acordo com uma das 3 seguintes categorias: (1) alteração ativa dos cuidados – por continuação ou descontinuação dos cuidados como resultado do ETT, (2) continuação dos cuidados – sem continuação ou descontinuação dos cuidados, mas comunicação ao paciente dos resultados do ETT, (3) sem alteração dos cuidados – os cuidados ao paciente já estavam a ser aplicados previamente ao resultado do ETT, causa de sintomas já estabelecida no momento da requisição para exame, exame prévio explicativo dos sintomas e sem indicação aguda para novo ETT, terapêutica não alterada ou inexistência de documentação relativa aos achados ecocardiográficos. Pacientes cujos registos não se encontravam disponíveis foram excluídos (259). Todas as classificações foram avaliadas por uma cardiologista independente, sem relação direta com o estudo. Resultados: A nossa amostra apresentou uma média de idades de 63 ± 17 anos, com uma equilíbrio de géneros. A maioria dos exames foi solicitada em contexto de ambulatório (81,4%), pela Cardiologia (50,3%) e pela Medicina Geral e Familiar (13,4%). Relativamente aos achados ecocardiográficos dos exames, 7,6% demonstraram disfunção sistólica do ventrículo esquerdo moderada a grave, 4,0% revelaram doença valvular grave e 5,1% hipertensão pulmonar significativa. Em relação à adequação dos pedidos para ETTs, 76,5% foram adequados, 7,1% inadequados e 12,6% incertos. Relativamente ao impacto clínico dos ETTs, 42,7% dos exames revelaram uma alteração ativa nos cuidados, 15,6% mostraram uma continuação dos cuidados e 11,5% demonstraram não haver alteração nos cuidados. A idade (P=0,05), o contexto de atendimento (P<0,01) e o pedido realizado pela especialidade medicina geral e familiar (MGF) (P=0,02) foram os preditores mais importantes de uma alteração ativa nos cuidados. Numa perspectiva de prestação de cuidados a uma população mais idosa, o contexto de atendimento, a presença de achados ecocardiográficos significativos e a não alteração dos cuidados apresentam uma relação significativa com a idade. Conclusões: Os dados demonstram que quase 8 em cada 10 ETTs foram considerados adequados e que 4 em cada 10 exames não apresentaram alteração ativa dos cuidados.