12 resultados para Ionizing radiation.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
In this thesis was investigated the radiation hardness of the building blocks of a future flexible X-ray sensor system. The characterized building blocks for the pixel addressing and signal amplification electronics are high mobility semiconducting oxide transistors (HMSO-TFTs) and organic transistors (OTFTs), whereas the photonic detection system is based on organic semiconducting single crystals (OSSCs). TFT parameters such as mobility, threshold voltage and subthreshold slope were measured as function of cumulative X-ray dose. Instead for OSSCs conductivity and X-ray sensitivity were analysed after various radiation steps. The results show that ionizing radiation does not lead to degradation in HMSO-TFTs. Instead OTFTs show instability in mobility which is reduced up to 73% for doses of 1 kGy. OSSC demonstrate stable detector properties for the tested total dose range. As conclusion, HMSO-TFTs and OSSCs can be readily employed in the X-ray detector system allowing operation for total doses exceeding 1 kGy of ionizing radiation.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro Área de especialização – Vidro
Resumo:
Resumo - O avanço tecnológico e científico no campo da Medicina tem favorecido a aplicação das radiações ionizantes nas áreas da Medicina Nuclear, Radiologia, Radioterapia e noutras especialidades relacionadas com a medicina de intervenção, como a Cardiologia. As Organizações de Saúde, com profissionais com risco de exposição a radiações ionizantes, são responsáveis, legislativamente, por assegurar a sua vigilância. Certificando a observação controlada das doses de exposição, os profissionais são monitorizados com dosímetros individuais e submetidos a vigilância médica. As leituras de dosímetria individual destes profissionais, originam por vezes, nos próprios, desconfianças e incertezas quanto aos valores medidos. Objectivo: avaliar o grau de confiança dos profissionais de saúde, expostos a radiações ionizantes, no sistema de monitorização individual. Metodologia: estudo observacional do tipo analítico- transversal, por questionário. Amostra de 190 Técnicos de Diagnóstico e Terapêutica de Cardiopneumologia, Medicina Nuclear, Radiologia, Radioterapia, expostos a radiações ionizantes, que exercem a sua actividade profissional em hospitais do concelho de Lisboa. Resultados: 51,1% dos Técnicos de Diagnóstico e Terapêutica não confiam nas leituras dos dosímetros, não se determinou uma relação estatisticamente significativa entre essa confiança, o tipo de dosímetro e a empresa que realiza as leituras. A confiança é maior nos que exercem em Organizações de Saúde públicas. 40,2% das Organizações de Saúde apresentam plano de vigilância médica, constatando-se uma falta de conformidade entre os Técnicos de Diagnóstico e Terapêutica, nalguns hospitais, relativamente à existência desse plano no respectivo hospital. A margem de erro associado ao estudo é de 5,09%, com um nível de confiança de 95%. -----------Abstract - The technological and scientific advances in the field of medicine has encouraged the application of ionizing radiation with a considerable positive contribution in the areas of Nuclear Medicine, Radiology, Radiotherapy and other specialties related to medical intervention like Cardiology. The Health Organizations that arise the risk of occupational exposure to ionizing radiation and is their responsibility to ensure monitoring, according the law. To ensure the monitoring of controlled doses of exposure, the exposed works use an individual dosimeter and undergo medical supervision. The individual dosimetry readings of health-care professionals, is sometimes questionable for themselves, arising distrust and uncertainty about the values measured. Objective: evaluate the degree of confidence of health professionals, exposed to radiation, on the system of individual monitoring. Methods: Observational study of cross-type analysis by questionnaire. Sample of 190 of technologists of Cardiopneumology, Nuclear Medicine, Radiology, Radiotherapy, exposed to ionizing radiation, which work in hospitals on the region of Lisbon. Results: 51.1% of technologists does not rely on the readings of their dosimeters, and wasn’t determined a statistically significant relationship between this trust, the type of dosimeter and the company that makes the readings(s) of their(s) dosimeter(s). The confidence in the readings is higher in public Health Organizations. 40.2% of the Health Organizations have medical monitoring plan and there is a disagreement between technologists, in some hospitals, relatively to the existence of this plan in their hospital. It was estimated that the u
Resumo:
Journal of Cultural Heritage, nº 9 (2008), p. 64-68
Resumo:
RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.
Resumo:
RESUMO: Este trabalho tentou contribuir para a caracterização da fisiopatologia da microcirculação coronária em diferentes formas de patologia com o auxílio da ecocardiografia transtorácica. Com a aplicação da ecocardiografia Doppler transtorácica foi efectuado o estudo da reserva coronária da artéria descendente anterior e com a ecocardiografia de contraste do miocárdio foram analisados parâmetros de perfusão do miocárdio como a velocidade da microcirculação coronária, o volume de sangue miocárdico e a reserva de fluxo miocárdico. Estas técnicas foram utilizadas em diferentes situações fisiopatológicas com particular interesse na hipertrofia ventricular esquerda de diferentes etiologias como a hipertensão arterial, estenose aórtica e cardiomiopatia hipertrófica. Também na diabetes mellitus tipo 2 e na doença coronária aterosclerótica, estudámos as alterações da microcirculação coronária. Com a mesma técnica de ecocardiografia de contraste do miocárdio foi analisada a perfusão do miocárdio num modelo experimental animal sujeito a uma dieta aterogénica. Além das conclusões específicas em relação a cada um dos trabalhos efectuados há a referir como conclusões gerais a sua fácil aplicabilidade e exequibilidade em âmbito clínico, a sua reprodutibilidade e precisão. Quando comparadas com técnicas consideradas de referência mostraram resultados com significativa correlação estatística. Em todos os doentes e nos grupos controle foi possível comprovar e quantificar o gradiente de perfusão transmural em repouso e durante a acção de stress vasodilatador, relevando a importância da perfusão sub-endocárdica na função do ventrículo esquerdo. O estudo da microcirculação coronária no grupo de doentes com hipertrofia ventricular esquerda revelou que no grupo com hipertensão arterial existe disfunção da microcirculação coronária ainda antes de se observar aumento de massa do ventrículo esquerdo, e que esta disfunção é diferente em função da geometria ventricular. Nos doentes com estenose aórtica foi demonstrado que além da disfunção da microcirculação coronária, explicada pelo fenómeno de hipertrofia, existe outro componente extrínseco que depois de corrigido através de cirurgia de substituição valvular, conduziu a uma parcial normalização dos valores de reserva coronária. Na cardiomiopatia hipertrófica observou-se uma grande heterogeneidade de perfusão transmural e foi documentado, em imagens de ecocardiografia de contraste do miocárdio e após análise paramétrica, a ausência de perfusão do miocárdio na região sub-endocárdica durante o stress vasodilatador de reserva coronária diminuídos em fases precoces de evolução da doença. Foi demonstrado que a reserva coronária na DM2 em fases mais avançadas estava significativamente diminuída. Descrevemos também em doentes com DM2 e sem doença coronária angiográfica a existência de disfunção da microcirculação coronária. Durante o stress vasodilatador, observámos e documentámos neste grupo de doentes, a existência de defeitos de perfusão transitórios ou de diminuição da velocidade da microcirculação coronária. No grupo de doentes com doença coronária confirmámos o interesse da avaliação da reserva coronária após intervenção percutânea na definição de prognóstico pós EAM, em termos de recuperação funcional do ventrículo esquerdo. Em doentes com BCRE e de difícil estratificação de risco, foi possível calcular o valor de reserva coronária e estratificar o risco de doença coronária. Num modelo experimental animal demonstrámos a exequibilidade da técnica de ECM, e verificámos que nessas condições experimentais, uma sobrecarga aterogénica na dieta, ao fim de 6 semanas, comprometia severamente a reserva coronária. Estes resultados foram parcialmente reversíveis quando à dieta foi adicionada uma estatina. Estas técnicas pela sua não invasibilidade, fácil acesso, repetibilidade e inocuidade perspectivam-se de grande utilidade na caracterização de doentes com disfunção da microcirculação coronária, nas diferentes áreas de diagnóstico, terapêutica e prevenção. A possibilidade de adaptar a técnica em modelos experimentais animais também nos parece poder vir a ter grande utilidade em investigação.----------------ABSTRACT: This work is intended to be a contribution to the study of coronary microcirculation applying new echocardiographic techniques as transthoracic Doppler echocardiography of coronary arteries and myocardial contrast echocardiography. Coronary flow reserve may be assessed by transthoracic Doppler echocardiography, and important functional microcirculation parameters as microcirculation flow velocity, myocardial blood volume and myocardial flow reserve may be evaluated through myocardial contrast echocardiography. Microcirculation was analysed in different pathophysiological settings. We addressed situations with increased left ventricular mass as systemic arterial hypertension, aortic stenosis and hypertrophic cardiomyopathy. Also coronary microcirculation was studied in type 2 Diabetes and in different clinical forms of atherosclerotic coronary artery disease. Specific and detailed conclusions were withdrawn from each experimental work. In the overall it was concluded that these two techniques were important tools to easily assess specific pathophysiological information about coronary microcirculation at bed side which would be difficult to get through other techniques. When compared with gold standard techniques, similar sensibility and specificity was found. Because of their better temporal and spatial resolution it was possible to analyse the importance of transmural perfusion gradients, both in basal and during vasodilatation, and their relation to ischemia, and mechanical wall kinetics, as wall thickening and motion. Coronary microcirculation dysfunction was found in systemic arterial hypertension early evolution stages, also related to different left ventricular geometric patterns. Different etiopathogenical explanations for aortic stenosis coronary microcirculation dysfunction were analysed and compared after aortic valve replacement. Transmural myocardial perfusion heterogeneity pattern was observed in hypertrophic cardiomyopathy which was aggravated during adenosine challenge. Coronary microcirculation dysfunction was diagnosed in type 2 diabetes both with coronary artery disease and with normal angiographic coronary arteries. Dynamic transitory subendocardial perfusion defects with adenosine vasodilatation were visualized in these patients.In patients with left branch block, transthoracic Doppler echocardiography was able to suggest a coronary reserve cut-off value for risk stratification. Also it was possible with this technique to calculate coronary flow reserve and predict restenosis after PTCA Again, in an experimental animal model, applying myocardial contrast echocardiography technique it was possible to study the consequences of an atherogenic diet and statins action on the coronary microcirculation function. Because these techniques are easily performed at bed side, are harmless, use no ionizing radiation and because of their repeatability, reproducibility and accuracythey are promissory tools to assess coronary microcirculation. Both in clinic and research areas these techniques will probably have a role in clinical diagnosis, prevention and therapeutically decision.
Resumo:
RESUMO - A exposição a radiações ionizantes em tomografia computorizada (TC) pode constituir-se como um risco para a saúde dos utentes. A TC é utilizada no diagnóstico e follow-up de doentes com Linfoma não-Hodgkin, subtipo Linfoma Difuso das Grandes Células B (LDGCB). O objetivo deste estudo foi determinar a dose efetiva acumulada e o risco de segundas neoplasias nestes doentes, diagnosticados em 2011 no IPOLFG e seguidos na consulta de hematologia até 2013. Foram avaliados retrospetivamente 70 doentes com base nos registos de dose do “Patient Protocol” das TC efetuadas. Em média cada doente fez 12 TC e a dose efetiva acumulada foi de 64,76 mSv (percentil 75). Três doentes foram expostos a doses de radiação superiores 90 mSv e um atingiu 111,72 mSv. Os resultados demonstram ser necessário rever os parâmetros e protocolos de exames de TC: (i) TC crânio (DLP= 777 mGycm) e TC abdominal-pélvico (DLP= 628 mGycm). O aumento do número de exames de TC efetuados e a consequente dose parece corresponder a um aumento do risco de segundas neoplasias e risco de morte por doenças neoplásicas durante a vida destes doentes. Os resultados são aparentemente mais significativos para as mulheres, que apresentam o dobro do risco de cancro do pulmão e risco de mortalidade superior em 14% para todas as doenças neoplásicas. O elevado número de exames de TC realizados por cada doente contribui para o aumento da probabilidade de efeitos deletérios e também para o aumento dos níveis de dose efetiva coletiva na população em geral.
Resumo:
RESUMO - A monitorização individual dos trabalhadores (dosimetria individual) é obrigatória (Decreto Regulamentar n.o 9/90, de 19 de Abril) para os profissionais de saúde que desempenham funções com risco de exposição à radiação X, quando classificados como categoria A. Apesar disso, a exposição a radiações ionizantes é frequentemente pouco, ou mesmo nada, valorizada pelos profissionais de saúde. O presente estudo, realizado no contexto de intervenções cirúrgicas de ortopedia, teve por objectivos: • avaliar a dose de radiação em diferentes zonas durante as cirurgias ortopédicas; • estimar a dose de exposição a radiações ionizantes dos profissionais de saúde, em função das suas posições, predominantemente adoptadas durante o acto cirúrgico; • sensibilizar os profissionais de saúde para a utilização correcta da dosimetria individual e para a adopção das medidas de protecção radiológica. A avaliação do risco foi efectuada através de: 1) medições preliminares com recurso a um fantoma colocado a 50 cm e a 100 cm do eixo central do feixe de radiação e em direcções de 45°, 90° e 135°; 2) medições durante uma cirurgia ortopédica em «localizações » correspondentes às gónadas, ao cristalino e às mãos dos profissionais de saúde intervenientes na cirurgia (ortopedistas, enfermeiros instrumentistas); 3) medições ao nível do topo da mesa (posição do anestesista) e ao nível do comando do equipamento emissor de raios X (técnico de radiologia); 4) determinação do tempo de utilização dos raios X durante as cirurgias ortopédicas; 5) cálculo da estimativa do número anual de cirurgias ortopédicas realizadas, com base nos registos existentes. Assumindo a não utilização de aventais plúmbeos os valores máximos medidos foram de 2,5 mSv/h (ao nível das gónadas), de 0,6 mSv/h ao nível do cristalino e de 1 mSv/ h ao nível das mãos dos ortopedistas e dos enfermeiros instrumentistas (que se situavam próximo do feixe de raios X, a 50 cm do feixe de radiação). A estimativa de exposição anual (dose equivalente) para os profissionais que operam junto ao feixe de radiação X foi de: • Ortopedistas — 20,63 a 68,75 mSv (gónadas), 4,95 a 16,50 mSv (cristalino) e 8,25 a 27,50 mSv (mãos); • Enfermeiros instrumentistas — 130,63 a 151,25 mSv (gónadas), 31,35 a 36,30 mSv (cristalino) e 52,25 a Os profissionais que ocupam posições mais afastadas do feixe (por exemplo: anestesistas) terão doses de radiação mais reduzidas, embora estas possam ainda ser importantes ao nível das gónadas na zona do topo da mesa (anestesista). Conclui-se que a exposição profissional em blocos operatórios pode implicar, em cirurgia ortopédica, a sujeição a níveis de exposição consideráveis, o que permite classificar estes profissionais de categoria A, justificando a utilização obrigatória (e correcta de acordo com as recomendações) da dosimetria individual e a adopção de medidas de protecção radiológica, tantas vezes negligenciadas.
Resumo:
Second International Workshop on Analog and Mixed Signal Integrated Circuits for Space Applications (AMICSA 2008), Sintra, Portugal, Setembro de 2008
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.