52 resultados para Graphical processing unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: Tobacco use remains the most significant modifiable cause of disability, death and illness1. In Portugal, 19,6% of the population aged ten years or more smoke3. A Cochrane review of 20087 concluded that a brief advice intervention (compared to usual care) can increase the likelihood of a smoker to quit and remain nonsmoker 12 months later by a further 1 to 3 %. Several studies have shown that Primary Care Physicians can play a key role in these interventions8,9,10. However we did not find studies about the effectiveness of brief interventions in routine consultations of Family Doctors in Portugal. For this reason we designed a Cohort Study to make an exploratory study about the effectiveness of brief interventions of less than three minutes in comparison with usual care in routine consultations. The study will be implemented in a Family Healthcare Unit in Beja, during six months. Family Doctors of the intervention group should be submitted for an educational and training program before the study begin. Quit smoking sustained rates will be estimated one year after the first intervention in each smoker. If, as we expect, quit smoking rates will be higher in the intervention group than in the control group, this may change Portuguese Family Doctors attitudes and increase the provision of brief interventions in routine consultations in Primary Healthcare Centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: A Medicina Transfusional está a mudar rapidamente em resposta a um número de diferentes catástrofes, patologias e novas técnicas da ciência. Por detrás de uma transfusão de sangue existe todo um conjunto de procedimentos, técnicas e atuações que salvaguardam o rigor e segurança científicas resultando numa maior eficiência na diminuição da morbilidade/mortalidade humana. Todo o processo de colheita, análise, processamento e distribuição de concentrados de eritrócitos comporta um capital elevado em termos da economia para a saúde e os requisitos básicos de uma gestão de qualidade, na área da saúde em geral e da hemoterapia em particular, tem de compreender, com rigor, estas condições de gestão parceria de forma a evitar um aumento nos custos da saúde. Para identificar as discrepâncias nos pedidos efetuados pelos Hospitais Públicos e Privados ao Centro de Sangue e Transplantação de Lisboa, no que diz respeito ao Sistema AB0 dos concentrados de Eritrócitos, foi feito um estudo quantitativo, com fins descritivos simples, aos 95 984 concentrados de eritrócitos enviados às 32 Instituições de Saúde da abrangência do CST de Lisboa. Tendo em conta o Sistema AB0 RhD, confirma-se que o grupo sanguíneo prevalente, tanto na população portuguesa como nos dadores de sangue que efetuaram a sua dádiva de sangue em 2011, é o grupo A Rh+. Observou-se no entanto que o grupo sanguíneo mais pedido e enviado pertence ao grupo 0 Rh positivo. Assim, apurou-se que existe uma disparidade, mesmo que pouco acentuada, nos pedidos efetuados pelos Hospitais Públicos e Privados ao Centro de Sangue e Transplantação de Lisboa no que configura ao Sistema AB0 dos concentrados de eritrócitos. Os Hospitais Públicos Sem Serviço de Colheita de Sangue e os Hospitais Privados são responsáveis por este desencontro de valores. No que se refere às inutilizações por prazo de validade ressalva-se que os desaproveitamentos de CE’s não são tão acentuados como se esperaria numa primeira fase de estudo. No entanto, e em termos económicos, se existem inutilizações por prazo de validade, existe igualmente despojo financeiro. Por detrás de cada unidade inutilizada existe um alto investimento que será desperdiçado por carência de solicitação. De forma a minimizar gastos e a salvaguardar um Banco de Sangue capaz de suportar qualquer eventualidade de rutura de stock estão patentes propostas de estratégias capazes de impedir constrangimentos diários e futuros no que diz respeito à disponibilidade de sangue e componentes sanguíneos.--------------ABSTRACT: The Transfusion Medicine it is changing fast in response to a number of different catastrophes, disease and new techniques of science. From behind a blood transfusion there is a whole set of procedures, techniques and actions that safeguard the safety and scientific rigor resulting in greater efficiency in reducing morbidity / mortality human. The entire process of procurement, testing, processing and distribution of concentrated erythrocytes involves a high capital in terms of the economy to health and the basic requirements of a quality management in healthcare in general and hemotherapy in particular has to understand with rigor, this partnership in order to avoid an increase in health costs. In order to identify discrepancies in the orders placed by the Government and Private Hospitals Center Blood and Transplant Lisbon regarding the AB0 system of concentrated erythrocytes was made a quantitative study with simple descriptive purposes to 95,984 erythrocytes concentrates sent to 32 Health Institutions of the scope of CST Lisbon. Having regard to the system AB0 blood group RhD prevalent both in the Portuguese population as blood donors, who made his blood donation in 2011, confirms that belong to group A Rh +. It was found that blood group most requested and sent belongs to group 0 Rh positive. Thus, it was found that there is a disparity, even a little sharp, requests made by the Government and Private Hospitals Blood Center and Transplantation in Lisbon that configures the system AB0 erythrocyte concentrates. The Public Hospitals without Blood Harvest and Private Hospitals are responsible for this clash of values. With regard the expiry date by disables proviso that the wastes of CE's are not as sharp as one would expect in a first phase of the study. However, in economic terms, if there is disables by expiry date, there is also financial squandering. Behind every unused unit is a high investment to be wasted by shortage of request. To minimize costs and safeguarding a Blood Bank can support any event of rupture of stock patents are proposed strategies to prevent future and diaries constraints with regard to the availability of blood and blood components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutora em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The EM3E Master is an Education Programme supported by the European Commission, the European Membrane Society (EMS), the European Membrane House (EMH), and a large international network of industrial companies, research centers and universities

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a volumetric unit previously assembled by the research group was upgraded. This unit revamping was necessary due to the malfunction of the solenoid valves employed in the original experimental setup, which were not sealing the gas properly leading to erroneous adsorption equilibrium measurements. Therefore, the solenoid valves were substituted by manual ball valves. After the volumetric unit improvement its operation was validated. For this purpose, the adsorption equilibrium of carbon dioxide (CO2) at 323K and 0 - 20 bar was measured on two different activated carbon samples, in the of extrudates (ANG6) and of a honeycomb monolith (ACHM). The adsorption equilibrium results were compared with data previously measured by the research group, using a high-pressure microbalance from Rubotherm GmbH (Germany) – gravimetric. The results obtained using both apparatuses are coincident thus validating the good operation of the volumetric unit upgraded in this work. Furthermore, the adsorption equilibrium of CO2 at 303K and 0 - 10 bar on Metal-Organic Frameworks (MOFs) Cu-BTC and Fe-BTC was also studied. The CO2 adsorption equilibrium results for both MOFs were compared with the literature results showing good agreement, which confirms the good quality of the experimental results obtained in the new volumetric unit. Cu-BTC sample showed significantly higher CO2 adsorption capacity when compared with the Fe-BTC sample. The revamping of the volumetric unit included a new valve configuration in order to allow testing an alternative method for the measurement of adsorption equilibrium. This new method was employed to measure the adsorption equilibrium of CO2 on ANG6 and ACHM at 303, 323 and 353K within 0-10 bar. The good quality of the obtained experimental data was testified by comparison with data previously obtained by the research group in a gravimetric apparatus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is devoted to study the pre-treatment of lignocellulosic biomass, especially wheat straw, by the application of the acidic ionic liquid (IL) such as 1-butyl-3-methylimidazolium hydrogen sulphate. The ability of this IL to hydrolysis and conversion of biomass was scrutinised. The pre-treatment with hydrogen sulphate-based IL allowed to obtain a liquor rich in hemicellulosic sugars, furans and organic acids, and a solid fraction mainly constituted by cellulose and lignin. Quantitative and qualitative analyses of the produced liquors were made by capillary electrophoresis and high-performance liquid chromatography. Pre-treatment conditions were set to produce xylose or furfural. Specific range of temperatures from 70 to 175 °C and residence times from 20.0 to 163.3 min were studied by fixing parameters such as biomass/IL ratio (10 % (w/w)) and water content (1.25 % (w/w)) in the pre-treatment process. Statistical modelling was applied to maximise the xylose and furfural concentrations. For the purpose of reaction condition comparison the severity factor for studied ionic liquid was proposed and applied in this work. Optimum conditions for xylose production were identified to be at 125 °C and 82.1 min, at which 16.7 % (w/w) xylose yield was attained. Furfural was preferably formed at higher pre-treatment temperatures and longer reaction time (161 °C and 104.5 min) reaching 30.7 % (w/w) maximum yield. The influence of water content on the optimum xylose formation was also studied. Pre-treatments with 5 and 10 % (w/w) water content were performed and an increase of 100 % and 140 % of xylose yield was observed, respectively, while the conversion into furfural maintained unchanged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.