26 resultados para calibrated cameras


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two-part tariffs, when used at the retail level, increase efficiency by lowering the price of marginal units. The same potential for higher efficiency exists for two-part tariffs at wholesale level for a given market structure, but the fixed part of the wholesale tariff can negatively affect the latter. In a simulated competition model of next-generation telecommunications access networks that has been calibrated with engineering cost data, we show that the latter effects strongly outweigh the former. That is, substituting a cost-based linear wholesale access tariff with revenue-equivalent two-part tariffs reduces the number of access seekers and therefore leads to higher prices and lower welfare and consumer surplus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a calibrated model of the UK mobile telephony market with four mobile networks; calls to and from the fixed network; network-based price discrimination; and call externalities. Our results show that reducing mobile termination rates broadly in line with the recent European Commission Recommendation to either pure long-run incremental cost ; reciprocal termination charges with fixed networks; or Bill & Keep (i.e. zero termination rates), increases social welfare, consumer surplus and networks profits. Depending on the strength of call externalities, social welfare may increase by as much as £ 990 million to £ 4.5 billion per year, with Bill & Keep leading to the highest increase in welfare. We also apply the model to estimate the welfare effects of the 2010 merger between Orange and T-Mobile under different scenarios concerning MTRs, and predict that consumer surplus decreases strongly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Geológica (Georrecursos)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eradication of code smells is often pointed out as a way to improve readability, extensibility and design in existing software. However, code smell detection remains time consuming and error-prone, partly due to the inherent subjectivity of the detection processes presently available. In view of mitigating the subjectivity problem, this dissertation presents a tool that automates a technique for the detection and assessment of code smells in Java source code, developed as an Eclipse plugin. The technique is based upon a Binary Logistic Regression model that uses complexity metrics as independent variables and is calibrated by expert‟s knowledge. An overview of the technique is provided, the tool is described and validated by an example case study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation to obtain the degree of Master in Chemical and Biochemical Engineering

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The widespread use of mobile devices has made known to the general public new areas that were hitherto confined to specialized devices. In general, the smartphone came to give all users the ability to execute multiple tasks, and among them, take photographs using the integrated cameras. Although these devices are continuously receiving improved cameras, their manufacturers do not take advantage of their full potential, since the operating systems normally offer simple APIs and applications for shooting. Therefore, taking advantage of this environment for mobile devices, we find ourselves in the best scenario to develop applications that help the user obtaining a good result when shooting. In an attempt to provide a set of techniques and tools more applied to the task, this dissertation presents, as a contribution, a set of tools for mobile devices that provides information in real-time on the composition of the scene before capturing an image. Thus, the proposed solution gives support to a user while capturing a scene with a mobile device. The user will be able to receive multiple suggestions on the composition of the scene, which will be based on rules of photography or other useful tools for photographers. The tools include horizon detection and graphical visualization of the color palette presented on the scenario being photographed. These tools were evaluated regarding the mobile device implementation and how users assess their usefulness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of the present dissertation is the simulation of the response of fibre grout strengthened RC panels when subjected to blast effects using the Applied Element Method, in order to validate and verify its applicability. Therefore, four experimental models, three of which were strengthened with a cement-based grout, each reinforced by one type of steel reinforcement, were tested against blast effects. After the calibration of the experimental set-up, it was possible to obtain and compare the response to the blast effects of the model without strengthening (reference model), and a fibre grout strengthened RC panel (strengthened model). Afterwards, a numerical model of the reference model was created in the commercial software Extreme Loading for Structures, which is based on the Applied Element Method, and calibrated to the obtained experimental results, namely to the residual displacement obtained by the experimental monitoring system. With the calibration verified, it is possible to assume that the numerical model correctly predicts the response of fibre grout RC panels when subjected to blast effects. In order to verify this assumption, the strengthened model was modelled and subjected to the blast effects of the corresponding experimental set-up. The comparison between the residual and maximum displacements and the bottom surface’s cracking obtained in the experimental and the numerical tests yields a difference of 4 % for the maximum displacements of the reference model, and a difference of 4 and 10 % for the residual and maximum displacements of the strengthened model, respectively. Additionally, the cracking on the bottom surface of the models was similar in both methods. Therefore, one can conclude that the Applied ElementMethod can correctly predict and simulate the response of fibre grout strengthened RC panels when subjected to blast effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spinning rotor gauge (SRG) is one of the most interesting vacuum gauges ever made, covering a pressure range of over seven orders of magnitude, with minimal gas interference (no pumping, ionization or heating of the measured gas), and a great stability of less than 1% drift per year. But despite its remarkable properties, apparently the SRG has not been further developed since the eighties, when it gained commercial interest. In this context, this dissertation aims at providing a starting point for a new line of investigation regarding this instrument, focused on the rotor itself. A brief study of different rotor geometries is provided, including a comparison between a cylindrical rotor and a spherical one. A cylindrical spinning rotor gauge (CSRG) is then proposed, based on the original SRG, but requiring a completely new lateral damping system. A prototype was built and tested against a non calibrated reference gauge.