17 resultados para Temperature to digital converter

em Instituto Polit


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a linguistically rule-based grapheme-to-phone (G2P) transcription algorithm is described for European Portuguese. A complete set of phonological and phonetic transcription rules regarding the European Portuguese standard variety is presented. This algorithm was implemented and tested by using online newspaper articles. The obtained experimental results gave rise to 98.80% of accuracy rate. Future developments in order to increase this value are foreseen. Our purpose with this work is to develop a module/ tool that can improve synthetic speech naturalness in European Portuguese. Other applications of this system can be expected like language teaching/learning. These results, together with our perspectives of future improvements, have proved the dramatic importance of linguistic knowledge on the development of Text-to-Speech systems (TTS).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O estudo das curvas características de um transístor permite conhecer um conjunto de parâmetros essenciais à sua utilização tanto no domínio da amplificação de sinais como em circuitos de comutação. Deste estudo é possível obter dados em condições que muitas vezes não constam na documentação fornecida pelos fabricantes. O trabalho que aqui se apresenta consiste no desenvolvimento de um sistema que permite de forma simples, eficiente e económica obter as curvas características de um transístor (bipolar de junção, efeito de campo de junção e efeito de campo de metal-óxido semicondutor), podendo ainda ser utilizado como instrumento pedagógico na introdução ao estudo dos dispositivos semicondutores ou no projecto de amplificadores transistorizados. O sistema é constituído por uma unidade de condicionamento de sinal, uma unidade de processamento de dados (hardware) e por um programa informático que permite o processamento gráfico dos dados obtidos, isto é, traçar as curvas características do transístor. O seu princípio de funcionamento consiste na utilização de um conversor Digital-Analógico (DAC) como fonte de tensão variável, alimentando a base (TBJ) ou a porta (JFET e MOSFET) do dispositivo a testar. Um segundo conversor fornece a variação da tensão VCE ou VDS necessária à obtenção de cada uma das curvas. O controlo do processo é garantido por uma unidade de processamento local, baseada num microcontrolador da família 8051, responsável pela leitura dos valores em corrente e em tensão recorrendo a conversores Analógico-Digital (ADC). Depois de processados, os dados são transmitidos através de uma ligação USB para um computador no qual um programa procede à representação gráfica, das curvas características de saída e à determinação de outros parâmetros característicos do dispositivo semicondutor em teste. A utilização de componentes convencionais e a simplicidade construtiva do projecto tornam este sistema económico, de fácil utilização e flexível, pois permite com pequenas alterações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atualmente, as radiações ionizantes desempenham um papel fundamental nas áreas de diagnóstico e terapia, estando omnipresentes em ambientes hospitalares. Contudo, devido aos efeitos biológicos adversos da radiação, torna-se essencial a protecção dos profissionais de saúde e pacientes. Consequentemente, um array de detetores capazes de produzir um sinal acústico, aquando da presença de radiação ionizante excedendo determinados valores limite e transmissão via wireless das leituras para um sistema central _e de grande interesse prático. Nesta dissertação, foi implementado um sistema capaz de alimentar um array de sensores de radiação para monitorização de diferentes espaços e transmissão das leituras efetuadas via wireless. A aquisição de dados foi realizada, recorrendo à utilização de um conversor analógico-digital. Vários testes de validação foram realizados, através de vários passos para alcançar a concretização do sistema final, nomeadamente testes relativos ao circuito de detecção, módulos de comunicação wireless, bem como o uso de diferentes ambientes de desenvolvimento integrados (IDE). Os resultados destes testes mostram a visualização e gravação adequadas dos dados relativos aos níveis de radiação, bem como a transmissão de dados de forma viável, permitindo a monitorização de espaços sujeitos à presença de radiação ionizante. Desta forma, um array de contadores Geiger-Müller, ligados a módulos wireless XBee open-source e uma placa Arduino, possibilitou a implementação de um sistema viável e de baixo custo para monitorização de radiação ionizante e registar esses mesmos dados para posterior análise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To analyze and compare the Ground Reaction Forces (GRF), during the stance phase of walking in pregnant women in the 3rd trimester of pregnancy, and non pregnant women. METHODS: 20 women, 10 pregnant and 10 non pregnant, voluntarily took part in this study. GRF were measured (1000 Hz) using a force platform (BERTEC 4060-15), an amplifier (BERTEC AM 6300) and an analogical-digital converter of 16 Bits (Biopac). RESULTS: The study showed that there were significant differences among the two groups concerning absolute values of time of the stance phase. In what concerns to the normalized values the most significant differences were verified in the maximums values of vertical force (Fz3, Fz1) and in the impulse of the antero-posterior force (Fy2), taxes of growth of the vertical force, and in the period of time for the antero-posterior force (Fy) be null. CONCLUSIONS: It is easier for the pregnant to continue forward movement (push-off phase). O smaller growth rates in what concerns to the maximum of the vertical force (Fz1) for the pregnant, can be associated with a slower speed of gait, as an adaptation strategy to maintain the balance, to compensate the alterations in the position of her center of gravity due to the load increase. The data related to the antero-posterior component of the force (Fy), shows that there is a significant difference between the pregnant woman’s left foot and right foot, which accuses a different functional behavior in each one of the feet, during the propulsion phase (TS).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado Apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Marketing Digital, sob orientação de Professor Doutor Freitas Santos

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smart Cities are designed to be living systems and turn urban dwellers life more comfortable and interactive by keeping them aware of what surrounds them, while leaving a greener footprint. The Future Cities Project [1] aims to create infrastructures for research in smart cities including a vehicular network, the BusNet, and an environmental sensor platform, the Urban Sense. Vehicles within the BusNet are equipped with On Board Units (OBUs) that offer free Wi-Fi to passengers and devices near the street. The Urban Sense platform is composed by a set of Data Collection Units (DCUs) that include a set of sensors measuring environmental parameters such as air pollution, meteorology and noise. The Urban Sense platform is expanding and receptive to add new sensors to the platform. The parnership with companies like TNL were made and the need to monitor garbage street containers emerged as air pollution prevention. If refuse collection companies know prior to the refuse collection which route is the best to collect the maximum amount of garbage with the shortest path, they can reduce costs and pollution levels are lower, leaving behind a greener footprint. This dissertation work arises in the need to monitor the garbage street containers and integrate these sensors into an Urban Sense DCU. Due to the remote locations of the garbage street containers, a network extension to the vehicular network had to be created. This dissertation work also focus on the Multi-hop network designed to extend the vehicular network coverage area to the remote garbage street containers. In locations where garbage street containers have access to the vehicular network, Roadside Units (RSUs) or Access Points (APs), the Multi-hop network serves has a redundant path to send the data collected from DCUs to the Urban Sense cloud database. To plan this highly dynamic network, the Wi-Fi Planner Tool was developed. This tool allowed taking measurements on the field that led to an optimized location of the Multi-hop network nodes with the use of radio propagation models. This tool also allowed rendering a temperature-map style overlay for Google Earth [2] application. For the DCU for garbage street containers the parner company provided the access to a HUB (device that communicates with the sensor inside the garbage containers). The Future Cities use the Raspberry pi as a platform for the DCUs. To collect the data from the HUB a RS485 to RS232 converter was used at the physical level and the Modbus protocol at the application level. To determine the location and status of the vehicles whinin the vehicular network a TCP Server was developed. This application was developed for the OBUs providing the vehicle Global Positioning System (GPS) location as well as information of when the vehicle is stopped, moving, on idle or even its slope. To implement the Multi-hop network on the field some scripts were developed such as pingLED and “shark”. These scripts helped upon node deployment on the field as well as to perform all the tests on the network. Two setups were implemented on the field, an urban setup was implemented for a Multi-hop network coverage survey and a sub-urban setup was implemented to test the Multi-hop network routing protocols, Optimized Link State Routing Protocol (OLSR) and Babel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Indústria Têxtil do Ave S.A. (ITA) dedica-se, desde 1948, à produção de componentes têxteis para pneus em forma de fio torcido (corda) e tela. Estes componentes são quimicamente activados e impregnados em estufas, possibilitando assim a posterior adesão ao pneu. A máquina de impregnar corda Single End é composta pelos grupos de estiragem, por um recipiente contendo a solução química e por 4 estufas em série. A máquina de impregnar tela Zell é composta pelos grupos de estiragem, pelos acumuladores de saída e entrada, pelos recipientes com as soluções químicas e por um grupo de 7 estufas em série. O aquecimento das estufas é feito através da queima de gás natural. O presente trabalho teve como objectivo a realização de uma auditoria energética à ITA com um especial destaque às máquinas de impregnar corda (Single End) e tela (Zell). As correntes de entrada que contribuem para a potência térmica de impregnação são a combustão do gás natural, o ar de combustão, o ar fresco, o artigo em verde e as soluções químicas. As correntes de saída correspondem aos gases de combustão e exaustão, ao artigo impregnado e às perdas térmicas. A auditoria à máquina Single End mostrou que a potência térmica de impregnação é de 413,1 kW. Dessa potência térmica, 77,2% correspondem à combustão do gás natural, 6,7% ao ar de combustão, 15% ao ar fresco, 0,7% às cordas em verde e 0,4% à solução química. Da potência térmica de saída, 88,4% correspondem aos gases de combustão e exaustão, 3,2% às cordas impregnadas e 8,4% às perdas térmicas. Da auditoria à máquina Zell observou-se que a potência térmica de impregnação é de 5630,7 kW. Dessa potência, 73,3% corresponde à combustão do gás natural, 1,6% ao ar de combustão, 24,5% ao ar fresco, 0,3% à tela em verde e 0,3% às soluções químicas. Da potência térmica de saída, 65,2% correspondem aos gases de combustão e exaustão, 3,1% à tela impregnada e 31,7% às perdas térmicas. Foram sugeridas como medidas de optimização a redução dos caudais de exaustão das estufas e o aumento de temperatura do ar fresco. O aumento da temperatura do ar fresco da máquina de impregnar Single End para 50 ºC, usando ar quente dos torcedores, leva a uma poupança de 0,22 €/h, com um período de retorno do investimento de 13 anos e 4 meses enquanto o aumento para 120 ºC, usando o calor dos gases de combustão e exaustão, reduz os custos em 0,88 €/h, sendo o período de retorno para esse investimento de 2 anos e 6 meses. Na máquina de impregnar Zell, uma redução de 15% no caudal de exaustão numa das estufas leva a ganhos de 3,43 €/h. O aumento de temperatura do ar fresco para 45 ºC, usando o calor de gases de combustão e exaustão, leva a uma poupança de 9,93 €/h sendo o período de retorno para cada uma das duas sugestões de investimento de 5 meses e 9 meses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho surgiu do âmbito da Tese de Dissertação do Mestrado em Energias Sustentáveis do Instituto Superior de Engenharia do Porto, tendo o acompanhamento dos orientadores da empresa Laboratório Ecotermolab do Instituto de Soldadura e Qualidade e do Instituto Superior de Engenharia do Porto, de forma a garantir a linha traçada indo de acordo aos objectivos propostos. A presente tese abordou o estudo do impacto da influência do ar novo na climatização de edifícios, tendo como base de apoio à análise a simulação dinâmica do edifício em condições reais num programa adequado, acreditado pela norma ASHRAE 140-2004. Este trabalho pretendeu evidenciar qual o impacto da influência do ar novo na climatização de um edifício com a conjugação de vários factores, tais como, ocupação, actividades e padrões de utilização (horários), iluminação e equipamentos, estudando ainda a possibilidade do sistema funcionar em regime de “Free-Cooling”. O princípio partiu fundamentalmente por determinar até que ponto se pode climatizar recorrendo único e exclusivamente à introdução de ar novo em regime de “Free-Cooling”, através de um sistema tudo-ar de Volume de Ar Variável - VAV, sem o apoio de qualquer outro sistema de climatização auxiliar localizado no espaço, respeitando os caudais mínimos impostos pelo RSECE (Decreto-Lei 79/2006). Numa primeira fase foram identificados todos os dados relativos à determinação das cargas térmicas do edifício, tendo em conta todos os factores e contributos alusivos ao valor da carga térmica, tais como a transmissão de calor e seus constituintes, a iluminação, a ventilação, o uso de equipamentos e os níveis de ocupação. Consequentemente foram elaboradas diversas simulações dinâmicas com o recurso ao programa EnergyPlus integrado no DesignBuilder, conjugando variáveis desde as envolventes à própria arquitectura, perfis de utilização ocupacional, equipamentos e taxas de renovação de ar nos diferentes espaços do edifício em estudo. Obtiveram-se vários modelos de forma a promover um estudo comparativo e aprofundado que permitisse determinar o impacto do ar novo na climatização do edifício, perspectivando a capacidade funcional do sistema funcionar em regime de “Free-Cooling”. Deste modo, a análise e comparação dos dados obtidos permitiram chegar às seguintes conclusões: Tendo em consideração que para necessidades de arrefecimento bastante elevadas, o “Free-Cooling” diurno revelou-se pouco eficaz ou quase nulo, para o tipo de clima verificado em Portugal, pois o diferencial de temperatura existente entre o exterior e o interior não é suficiente de modo a tornar possível a remoção das cargas de forma a baixar a temperatura interior para o intervalo de conforto. Em relação ao “Free-Cooling” em horário nocturno ou pós-laboral, este revelou-se bem mais eficiente. Obtiveram-se prestações muito interessantes sobretudo durante as estações de aquecimento e meia-estação, tendo em consideração o facto de existir necessidades de arrefecimento mesmo durante a estação de aquecimento. Referente à ventilação nocturna, isto é, em períodos de madrugada e fecho do edifício, concluiu-se que tal contribui para um abaixamento do calor acumulado durante o dia nos materiais construtivos do edifício e que é libertado ou restituído posteriormente para os espaços em períodos mais tardios. De entre as seguintes variáveis, aumento de caudal de ar novo insuflado e o diferencial de temperatura existente entre o ar exterior e interior, ficou demonstrado que este último teria maior peso contributivo na remoção do calor. Por fim, é ponto assente que de um modo geral, um sistema de climatização será sempre indispensável devido a cargas internas elevadas, requisitos interiores de temperatura e humidade, sendo no entanto aconselhado o “Free- Cooling” como um opção viável a incorporar na solução de climatização, de forma a promover o arrefecimento natural, a redução do consumo energético e a introdução activa de ar novo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to determine, for Newtonian and non-Newtonian fluids, the friction factor (fc) with simultaneous heat transfer, at constant wall temperature as boundary condition, in fully developed laminar flow inside a vertical helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w). The non-Newtonian fluids were aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations of 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations of 0.1% and 0.2% (w/w). According to the rheological study done, the polymer solutions had shear-thinning behavior and different values of viscoelasticity. The helical coil used has an internal diameter, curvature ratio, length and pitch, respectively: 0.00483 m, 0.0263, 5.0 m and 11.34 mm. It was concluded that the friction factors, with simultaneous heat transfer, for Newtonian fluids can be calculated using expressions from literature for isothermal flows. The friction factors for CMC and XG solutions are similar to those for Newtonian fluids when the Dean number, based in a generalized Reynolds number, is less than 80. For Dean numbers higher than 80, the friction factors of the CMC solutions are lower those of the XG solutions and of the Newtonian fluids. In this range the friction factors decrease with the increase of the viscometric component of the solution and increase for increasing elastic component. The change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, is in accordance with the study of Ali [4]. There is a change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, which is in according to previous studies. The data also showed that the use of the bulk temperature or of the film temperature to calculate the physical properties of the fluid has a residual effect in the friction factor values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O projeto tem como objetivo desenvolver e avaliar um modelo que facilita o acesso para pessoas surdas ou com deficiência auditiva, o acesso ao conteúdo digital - em particular o conteúdo educacional e objetos de aprendizagem – a criação de condições para uma maior inclusão social de surdos e deficientes auditivos. Pretende-se criar um modelo bidirecional, em que permite a pessoas com deficiências auditivas, possam se comunicar com outras pessoas, com a tradução da Língua Gestual Portuguesa (LGP) para a Língua Portuguesa (LP) e que outras pessoas não portadoras de qualquer deficiência auditiva possam por sua vez comunicar com os surdos ou deficientes auditivos através da tradução da LP para a LGP. Há um conjunto de técnicas que poderíamos nos apoiar para desenvolver o modelo e implementar a API de tradução da LGP em LP. Muitos estudos são feitos com base nos modelos escondidos de Markov (HMM) para efetuar o reconhecimento. Recentemente os estudos estão a caminhar para o uso de técnicas como o “Dynamic Time Warping” (DTW), que tem tido mais sucesso do que outras técnicas em termos de performance e de precisão. Neste projeto optamos por desenvolver a API e o Modelo, com base na técnica de aprendizagem Support Vector Machines (SVM) por ser uma técnica simples de implementar e com bons resultados demonstrados em reconhecimento de padrões. Os resultados obtidos utilizando esta técnica de aprendizagem foram bastante ótimos, como iremos descrever no decorrer do capítulo 4, mesmo sabendo que utilizamos dois dispositivos para capturar dados de descrição de cada gesto. Toda esta tese integra-se no âmbito do projeto científico/ investigação a decorrer no grupo de investigação GILT, sob a coordenação da professora Paula Escudeiro e suportado pela Fundação para Ciência e Tecnologia (FCT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O projeto realizado teve como tema a aplicação das derivadas e integrais fraccionários para a implementação de filtros digitais numa perspetiva de processamento digital de sinais. Numa primeira fase do trabalho, é efetuado uma abordagem teórica sobre os filtros digitais e o cálculo fraccionário. Estes conceitos teóricos são utilizados posteriormente para o desenvolvimento do presente projeto. Numa segunda fase, é desenvolvida uma interface gráfica em ambiente MatLab, utilizando a ferramenta GUIDE. Esta interface gráfica tem como objetivo a implementação de filtros digitais fraccionários. Na terceira fase deste projeto são implementados os filtros desenvolvidos experimentalmente através do ADSP-2181, onde será possível analisar e comparar os resultados experimentais com os resultados obtidos por simulação no MatLab. Como quarta e última fase deste projeto é efetuado uma reflexão sobre todo o desenvolvimento da Tese e o que esta me proporcionou. Com este relatório pretendo apresentar todo o esforço aplicado na realização deste trabalho, bem como alguns dos conhecimentos adquiridos ao longo do curso.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Electromyography (EMG) is an important tool for gait analyzes and disorders diagnoses. Traditional methods involve equipment that can disturb the analyses, being gradually substituted by different approaches, like wearable and wireless systems. The cable replacement for autonomous systems demands for technologies capable of meeting the power constraints. This work presents the development of an EMG and kinematic data capture wireless module, designed taking into account power consumption issues. This module captures and converts the analog myoeletric signal to digital, synchronously with the capture of kinetic information. Both data are time multiplexed and sent to a PC via Bluetooth link. The work carried out comprised the development of the hardware, the firmware and a graphical interface running in an external PC. The hardware was developed using the PIC18F14K22, a low power family of microcontrollers. The link was established via Bluetooth, a protocol designed for low power communication. An application was also developed to recover and trace the signal to a Graphic User Interface (GUI), coordinating the message exchange with the firmware. Results were obtained which allowed validating the conceived system in static and with the subject performing short movements. Although it was not possible to perform the tests within more dynamic movements, it is shown that it is possible to capture, transmit and display the captured data as expected. Some suggestions to improve the system performance also were made.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In an increasingly competitive and globalized world, companies need effective training methodologies and tools for their employees. However, selecting the most suitable ones is not an easy task. It depends on the requirements of the target group (namely time restrictions), on the specificities of the contents, etc. This is typically the case for training in Lean, the waste elimination manufacturing philosophy. This paper presents and compares two different approaches to lean training methodologies and tools: a simulation game based on a single realistic manufacturing platform, involving production and assembly operations that allows learning by playing; and a digital game that helps understand lean tools. This paper shows that both tools have advantages in terms of trainee motivation and knowledge acquisition. Furthermore, they can be used in a complementary way, reinforcing the acquired knowledge.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Hoje em dia as fontes de alimentação possuem correção do fator de potência, devido às diversas normas regulamentares existentes, que introduziram grandes restrições no que respeita à distorção harmónica (THD) e fator de potência (FP). Este trabalho trata da análise, desenvolvimento e implementação de um Pré-Regulador de fator de potência com controlo digital. O controlo digital de conversores com recurso a processamento digital de sinal tem vindo a ser ao longo dos últimos anos, objeto de investigação e desenvolvimento, estando constantemente a surgirem modificações nas topologias existentes. Esta dissertação tem como objetivo estudar e implementar um Pré-Regulador Retificador Boost e o respetivo controlo digital. O controlo do conversor é feito através da técnica dos valores médios instantâneos da corrente de entrada, desenvolvido através da linguagem de descrição de hardware VHDL (VHSIC HDL – Very High Speed Integrated Circuit Hardware Description Language) e implementado num dispositivo FPGA (Field Programmable Gate Array) Spartan-3E. Neste trabalho são apresentadas análises matemáticas, para a obtenção das funções de transferência pertinentes ao projeto dos controladores. Para efetuar este controlo é necessário adquirir os sinais da corrente de entrada, tensão de entrada e tensão de saída. O sinal resultante do módulo de controlo é um sinal de PWM com valor de fator de ciclo variável ao longo do tempo. O projeto é simulado e validado através da plataforma MatLab/Simulink e PSIM, onde são apresentados resultados para o regime permanente e para transitórios da carga e da tensão de alimentação. Finalmente, o Pré-Regulador Retificador Boost controlado de forma digital é implementado em laboratório. Os resultados experimentais são apresentados para validar a metodologia e o projeto desenvolvidos.