15 resultados para thermal degradation
em Instituto Politécnico do Porto, Portugal
Resumo:
Despite the fact that their physical properties make them an attractive family of materials, composites machining can cause several damage modes such as delamination, fibre pull-out, thermal degradation, and others. Minimization of axial thrust force during drilling reduces the probability of delamination onset, as it has been demonstrated by analytical models based on linear elastic fracture mechanics (LEFM). A finite element model considering solid elements of the ABAQUS® software library and interface elements including a cohesive damage model was developed in order to simulate thrust forces and delamination onset during drilling. Thrust force results for delamination onset are compared with existing analytical models.
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
Ao percorrermos as cidades portuguesas, deparámo-nos frequentemente com fachadas de edifícios muito degradadas, não só de edifícios antigos, mas também de edifícios recentes (construção edificada a partir do início da década de 70). A presença de anomalias nas fachadas, para além de ser esteticamente desagradável na paisagem urbana, pode também potenciar a degradação prematura da envolvente vertical dos edifícios, deixando estas de desempenhar satisfatoriamente as funções de impermeabilidade e eficiência térmica. Tem-se assistido nas últimas décadas em Portugal, não só a uma evolução das técnicas construtivas das fachadas face à crescente exigência da qualidade dos edifícios, mas também a uma crescente utilização de novos revestimentos, nomeadamente, o sistema de isolamento térmico pelo exterior, conhecido pela sigla inglesa ETICS (External Thermal Insulation Composite System) e designado por “revestimento delgado armado sobre isolante”. O principal objectivo da presente dissertação consiste no desenvolvimento e aplicação de uma proposta de metodologia para análise da patologia de fachadas de edifícios recentes com sistema ETICS, que gradualmente tem vindo a implantar-se em Portugal como uma das soluções de carácter inovador de isolamento térmico e de protecção higrométrica da envolvente vertical opaca dos edifícios.
Resumo:
Purpose Polycyclic aromatic hydrocarbons (PAHs) are a class of organic compounds commonly found as soil contaminants. Fungal degradation is considered as an environmentally friendly and cost-effective approach to remove PAHs from soil. Acenaphthylene (Ace) and Benzo[a]anthracene (BaA) are two PAHs that can coexist in soils; however, the influence of the presence of each other on their biodegradation has not been studied. The biodegradation of Ace and BaA, alone and in mixtures, by the white rot fungus Pleurotus ostreatus was studied in a sandy soil. Materials and methods Experimental microcosms containing soil spiked with different concentrations of Ace and BaAwere inoculated with P. ostreatus. Initial (t 0) and final (after 15 days of incubation) soil concentrations of Ace and BaA were determined after extraction of the PAHs. Results and discussion P. ostreatus was able to degrade 57.7% of the Ace in soil spiked at 30 mg kg−1 dry soil and 65.8% of Ace in soil spiked at 60 mg kg−1 dry soil. The degradation efficiency of BaA by P. ostreatus was 86.7 and 77.4% in soil spiked with Ace at 30 and 60 mg kg−1 dry soil, respectively. After 15 days of incubation, there were no significant differences in Ace concentration between soil spiked with Ace and soil spiked with Ace + BaA, irrespective of the initial soil concentration of both PAHs. There were also no differences in BaA concentration between soil spiked with BaA and soil spiked with BaA + Ace. Conclusions The results indicate that the fungal degradation of Ace and BaA was not influenced by the presence of each other’s PAH in sandy soil. Bioremediation of soils contaminated with Ace and BaA using P. ostreatus is a promising approach to eliminate these PAHs from the environment.
Resumo:
Neste trabalho é abordado o estágio efectuado por um período de sete meses na E.A. (Engenheiros Associados) e um estudo de caso sobre as tecnologias aplicadas no isolamento térmico de paredes exteriores. Na primeira parte deste relatório é efectuada uma breve caracterização da empresa e da sua actividade no mercado. A Engenheiros e Associados tem a sua estrutura assente nos seguintes sectores: Técnico-Comercial, de Aprovisionamento e de Gestão Administrativa; da qual foi efectuada uma descrição do trabalho desenvolvido em cada um desses sectores, nomeadamente a permanência na obra e as visitas e diligências às obras. A segunda parte deste relatório, que é a parte fulcral do trabalho desenvolvido, assenta sobre o sistema de ETICS (External Thermal Insulation Composite System), ou seja, o sistema de reboco delgado armado sobre isolamento térmico. Foi utilizado o sistema Cappotto na Obra de Requalificação da Urbanização de Vila d’Este – 1ª Fase. Após uma breve apresentação e evolução da história do ETICS ao longo do tempo, é exposta a caracterização da obra onde vai ser aplicado o sistema, que recai sobre a tipologia dos edifícios. Refira-se que, neste relatório, os edifícios por serem de construção túnel se dividem em três tipos: tipo plana ou corrente, tipo ângulo e tipo topo. Na Analise de Patologias efectuada evidenciam-se as fissuras e a humidade presentes em quase toda a extensão dos referidos edifícios antes do tratamento, tornando-as assim as principais anomalias destes edifícios. Foram elemento de foco as anomalias existentes nos edifícios, como: Deterioração do fibrocimento; Insuficiência das caleiras; Deficiências das impermeabilizações; Ausência de rufos; Deficiência das ligações; Degradação do revestimento e pintura; Fissuração do reboco; Degradação dos forros exteriores; Deterioração das padieiras; Deterioração dos peitoris; Deterioração das juntas de dilatação; Infiltrações e condensações; Ruptura das canalizações; Deslocamentos; Deficiências de ventilação; Deficiências de estanqueidade; Inexistência de Sistema de combate a incêndios. Para estas patologias são apresentadas as propostas de solução de forma a eliminar as mesmas. Sendo o ETICS escolhido por ser o sistema que elimina a maior parte destas patologias, tendo em conta uma relação de qualidade/preço, é abordada de uma forma detalhada e extensiva da aplicação do sistema antes, durante e depois da obra em si. Assim como, é feita uma descrição pormenorizada do material utilizado para a implementação do sistema. A análise dos pontos críticos refere-se a zonas sensíveis onde há a necessidade de reforço do sistema com vista a eliminar o aparecimento posterior de patologias, como por exemplo as características de suporte. Após a aplicação do sistema podem aparecer algumas patologias das quais se destaca o facto dos produtos serem preparados em obra, o erro humano nas dosagens do fabricante e no acrescento de água sem necessidade e a par das condições climatéricas, são as causas mais comuns do aparecimento de anomalias no sistema de ETICS, provocando fissurações e infiltrações, que são descritas neste relatório. É também abordada a manutenção e reparação do sistema, onde a manutenção refere-se à lavagem e à remoção de microorganismos das paredes e posterior pintura. A reparação dos danos divide-se em dois tipos, áreas até 2 cm2 e áreas maiores que 2 cm2. Por fim, são apresentados alguns rendimentos, que foram possíveis obter ao longo do desenvolvimento do trabalho, dos materiais e da mão-de-obra, dando origem aos custos directos. Sendo também abordadas as vantagens e desvantagens do sistema desde o seu início até à sua conclusão.
Resumo:
The present work describes the development of an analytical method for the determination of methiocarb and its degradation products (methiocarb sulfoxide and methiocarb sulfone) in banana samples, using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure followed by liquid chromatography coupled to photodiode array detector (LCPAD). Calibration curves were linear in the range of 0.5−10 mg L−1 for all compounds studied. The average recoveries, measured at 0.1 mg kg−1 wet weight, were 92.0 (RSD = 1.8%, n = 3), 84.0 (RSD = 3.9%, n = 3), and 95.2% (RSD = 1.9%, n = 3) for methiocarb sulfoxide, methiocarb sulfone, and methiocarb, respectively. Banana samples treated with methiocarb were collected from an experimental field. The developed method was applied to the analysis of 24 samples (peel and pulp) and to 5 banana pulp samples. Generally, the highest levels were found for methiocarb sulfoxide and methiocarb. Methiocarb sulfone levels were below the limit of quantification, except in one sample (not detected).
Resumo:
Alheiras are a traditional, smoked, fermented meat sausage, produced in Portugal, with an undeniable cultural and gastronomic legacy. In this study, we assessed the nutritional value of this product, as well as the influence of different types of thermal processing. Alheiras from Mirandela were submitted to six different procedures: microwave, skillet, oven, charcoal grill, electric fryer and electric grill. Protein, fat, carbohydrate, minerals, NaCl, and cholesterol contents, as well as fatty acid profile were evaluated. The results show that alheiras are not hypercaloric but an unbalanced foodstuff (high levels of proteins and lipids) and the type of processing has a major impact on their nutritional value. Charcoal grill is the healthiest option: less fat (12.5 g/100 g) and cholesterol (29.3 mg/100 g), corresponding to a lower caloric intake (231.8 kcal, less 13% than the raw ones). Inversely, fried alheiras presented the worst nutritional profile, with the highest levels of fat (18.1 g/100 g) and cholesterol (76.0 g/100 g).
Resumo:
The main aims of the present study are simultaneously to relate the brazing parameters with: (i) the correspondent interfacial microstructure, (ii) the resultant mechanical properties and (iii) the electrochemical degradation behaviour of AISI 316 stainless steel/alumina brazed joints. Filler metals on such as Ag–26.5Cu–3Ti and Ag–34.5Cu–1.5Ti were used to produce the joints. Three different brazing temperatures (850, 900 and 950 °C), keeping a constant holding time of 20 min, were tested. The objective was to understand the influence of the brazing temperature on the final microstructure and properties of the joints. The mechanical properties of the metal/ceramic (M/C) joints were assessed from bond strength tests carried out using a shear solicitation loading scheme. The fracture surfaces were studied both morphologically and structurally using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction analysis (XRD). The degradation behaviour of the M/C joints was assessed by means of electrochemical techniques. It was found that using a Ag–26.5Cu–3Ti brazing alloy and a brazing temperature of 850 °C, produces the best results in terms of bond strength, 234 ± 18 MPa. The mechanical properties obtained could be explained on the basis of the different compounds identified on the fracture surfaces by XRD. On the other hand, the use of the Ag–34.5Cu–1.5Ti brazing alloy and a brazing temperature of 850 °C produces the best results in terms of corrosion rates (lower corrosion current density), 0.76 ± 0.21 μA cm−2. Nevertheless, the joints produced at 850 °C using a Ag–26.5Cu–3Ti brazing alloy present the best compromise between mechanical properties and degradation behaviour, 234 ± 18 MPa and 1.26 ± 0.58 μA cm−2, respectively. The role of Ti diffusion is fundamental in terms of the final value achieved for the M/C bond strength. On the contrary, the Ag and Cu distribution along the brazed interface seem to play the most relevant role in the metal/ceramic joints electrochemical performance.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
Thermally expandable particles (TEPs) are used in a wide variety of applications by industry mainly for weight reduction and appearance improvement for thermoplastics, inks, and coatings. In adhesive bonding, TEPs have been used for recycling purposes. However, TEPs might be used to modify structural adhesives for other new purposes, such as: to increase the joint strength by creating an adhesive functionally modified along the overlap of the joint by gradual heating and/or to heal the adhesive in case of damage. In this study, the behaviour of a structural polyurethane adhesive modified with TEPs was investigated as a preliminary study for further investigations on the potential of TEPs in adhesive joints. Tensile bulk tests were performed to get the tensile properties of the unmodified and TEPs-modified adhesive, while Double Cantilever Beam (DCB) test was performed in order to evaluate the resistance to mode I crack propagation of unmodified and TEPs-modified adhesive. In addition, in order to investigate the behaviour of the particles while encapsulated in adhesives, a thermal analysis was done. Scanning electron microscopy (SEM) was used to examine the fracture surface morphology of the specimens. The fracture toughness of the TEPs-modified adhesive was found to increase by addition of TEPs, while the adhesive tensile strength at yield decreased. The temperature where the particles show the maximum expansion varied with TEPs concentration, decreasing with increasing the TEPs content.
Resumo:
Durante séculos a madeira foi dos materiais mais privilegiados e usados na construção. Ainda hoje, existem construções antigas em madeira em bom estado de conservação e que, desempenham as suas funções adequadamente. Com o aparecimento do betão e do aço, os projetistas deixaram de usar este tipo de estruturas. Isto provocou um desinteresse na indústria da madeira, adiando a criação de regulamentos e normas relativamente às exigências funcionais deste tipo de estruturas. Com a necessidade da reabilitação do património edificado, verifica-se uma inversão desta tendência, devido às edificações no centro histórico serem constituídas por estruturas de madeira, essencialmente os pavimentos e coberturas. Na maioria das vezes estas estruturas apresentam um elevado nível de degradação e a solução mais rentável é demolir. Os pavimentos de madeira são então substituídos por lajes aligeiradas ou de betão armado provocando alterações estruturais inadequadas nas fachadas a manter. Pretende-se com esta dissertação mostrar as potencialidades dos pavimentos de madeira e assim incentivar ao seu uso, principalmente nas áreas a reabilitar. São analisados todos os regulamentos e normas aplicáveis às exigências estruturais, térmicas, acústicas e contra incêndio dos pavimentos de madeira. A análise da normalização aplicável vai ser sintetizada, ou seja, só vão ser referidos os aspetos a ter em conta para a verificação das exigências funcionais em pavimentos de madeira. A aplicação dos conceitos e das verificações necessárias são aplicadas a um pavimento de madeira a ser construído na parcela C4 do Quarteirão das Cardosas. Os resultados obtidos neste caso de estudo são encorajadores, e abrem uma perspetiva das potencialidades que este sistema construtivo apresenta.
Resumo:
The purpose of this work was to develop a reliable alternative method for the determination of the dithiocarbamate pesticide mancozeb (MCZ) in formulations. Furthermore, a method for the analysis of MCZ's major degradation product, ethylenethiourea (ETU), was also proposed. Cyclic voltammetry was used to characterize the electrochemical behavior of MCZ and ETU, and square-wave adsorptive stripping voltammetry (SWAdSV) was employed for MCZ quantification in commercial formulations. It was found that both MCZ and ETU are irreversibly reduced (− 0.6 V and − 0.5 V vs Ag/AgCl, respectively) at the surface of a glassy carbon electrode in a mainly diffusion-controlled process, presenting maximum peak current intensities at pH 7.0 (in phosphate buffered saline electrolyte). Several parameters of the SWAdSV technique were optimized and linear relationships between concentration and peak current intensity were established between 10–90 μmol L− 1 and 10–110 μmol L− 1 for MCZ and ETU, respectively. The limits of detection were 7.0 μmol L− 1 for MCZ and 7.8 μmol L− 1 for ETU. The optimized method for MCZ was successfully applied to the quantification of this pesticide in two commercial formulations. The developed procedures provided accurate and precise results and could be interesting alternatives to the established methods for quality control of the studied products, as well as for analysis of MCZ and ETU in environmental samples.
Resumo:
Temporomandibular disorders (TMD) consist of a group of pathologies that affect the masticatory muscles, temporomandibular joints (TMJ), and/or related structures. String instrumentalists, like many orchestra musicians, can spend hours with head postures that may influence the biomechanical behavior of the TMJ and the muscles of the craniocervicomandibular complex (CCMC). The adoption of abnormal postures acquired during performance by musicians can lead to muscular hyperactivity of the head and cervical muscles, with the possible appearance of TMD. Medical infrared thermography is a non-invasive procedure that can monitor the changes in the superficial tissue related to blood circulation and may serve as a complement to the clinical examination. The objective of this study was to use infrared thermography to evaluate, in one subject, the cutaneous thermal changes adjacent to the CCMC that occur before, during, and after playing a string instrument.
Resumo:
This document presents particular description of work done during student’s internship in PR Metal company realized as ERASMUS PROJECT at ISEP. All information including company’s description and its structure, overview of the problems and analyzed cases, all stages of projects from concept to conclusion can be found here. Description of work done during the internship is divided here into two pieces. First part concerns one activities of the company which is robotic chefs (kitchen robot) production line. Work, that was done for development of this line involved several tasks, among them: creating a single-worker montage station for screwing robots housing’s parts, improve security system for laser welding chamber, what particularly consists in designing automatically closing door system with special surface, that protects against destructive action of laser beam, test station for examination of durability of heating connectors, solving problem with rotors vibrations. Second part tells about main task, realized in second half of internship and stands a complete description of machine development and design. The machine is a part of car handle latch cable production line and its tasks are: cutting cable to required length and hot-forming plastic cover for further assembly needs.