29 resultados para stripping injection

em Instituto Politécnico do Porto, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology for the determination of the pesticide chlorfenvinphos by microwave-assisted solvent extraction and square-wave cathodic stripping voltammetry at a mercury film ultramicroelectrode in soil samples is proposed. Optimization of microwave solvent extraction performed with two soils, selected for having significantly different properties, indicated that the optimum solvent for extracting chlorfenvinphos is hexane-acetone (1:1, v/v). The voltammetric procedure is based on controlled adsorptive accumulation of the insecticide at the potential of -0.60 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 6.2). The detection limit obtained for a 10 s collection time was 3.0 x 10-8 mol l-1. The validity of the developed methodology was assessed by recovery experiments at the 0.100 µg g-1 level. The average recoveries and standard deviations for the global procedure reached byMASE-square-wave voltammetry were 90.2±2.8% and 92.1±3.4% for type I (soil rich in organic matter) and type II (sandy soil) samples, respectively. These results are in accordance to the expected values which show that the method has a good accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An adsorptive stripping voltammetric procedure for the determination of the antidepressant venlafaxine in urine using a mercury film microelectrode wasdeveloped. The method is based on controlled adsorptive accumulation of the drug at the potential of 1.00V (vs. Ag/AgCl) in the presence of 1.25 x10 -2 molL- 1 borate buffer (pH 8.7). Urine samples were analyzed directly after performing a ten-fold dilution with the supporting electrolyte but without other pretreatment. The limit of detection obtained for a 30 s collection time was 0.693x 10- 6 mol L -1. Recovery experimentsgave good results at the 10 -6 mol L- 1 level (bias less 5% were obtained).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave-assisted solvent extraction was combined with anodic adsorptive stripping voltammetry at a gold microelectrode to extract and quantify the herbicide atrazine in spiked soil samples. A systematic study of the experimental parameters affecting the stripping response was carried out by square-wave voltammetry. The voltammetric procedure is based on controlled adsorptive accumulation of atrazine at the potential of 0.35V (versus Ag/AgCl) in the presence of Britton–Robinson buffer pH (2.0). The limit of detection obtained for a 30 sec collection time was 4.3x10-7 mol L-1. Recovery experiments, at the 1µgg-1 level of spiking, gave good results for the global procedure, and the values found were comparable to those obtained by HPLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few analytical methods are currently available for determination of apomorphine, the active substance of a new oral formulation used in the treatment of erectile dysfunction. In this way a flow injection electrochemical method (FIA-EC) was developed for its quantification and applied to pharmaceutical dosage forms. Based in previous findings regarding the stability of apomorphine in borate buffer and after optimization of several analytical parameters a single channel flow injection manifold was set up that enables the determination of this drug over the concentration range of 3 to 16 µmol L-1 with a detection limit of 0.5 µmol L-1 at a sampling rateof 90 h-1. The simplicity and rapidity of the FIA-EC method used, its reproducibility and sensitivity make it suitable for quality control of pharmaceutical preparations of apomorphine intended for clinical use and research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction- coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L–1, and with a sensitivity of 344 L mol–1 cm–1 and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h–1. Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin–Ciocalteu method, <5.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New chlorpromazine selective electrodes with a tubular arrangement and no internal reference solution are proposed. Selective membranes are of poly(vinyl chloride) (PVC) with the tetraphenylborate•chlorpromazine (TPB•CPZ) ion-exchanger dissolved in o-nitrophenyl octyl ether (oNPOE). Analytical features of the electrodes were evaluated on a single-channel flow assembly having 500 µl injection volumes and flow-rates of 4.5 ml min−1. For a carrier solution of 3.3×10−3Min sodium sulphate, Nernstian responsewas observed over the concentration range 1.0×10−5 to 1.0×10−2 M. Average slopes were about 59mVdecade−1 and squared correlation coefficients were >0.9984. Slight hiper-Nernstian behaviour was observed in buffer solutions of 4.4 pH; average slopes were of 62.06mVdecade−1. The electrode displayed a good selectivity for CPZ, with respect to, several foreign inorganic and organic species. The selective electrodes were successfully applied to the analysis of pure solutions and pharmaceutical preparations. Proposed method allows the analysis of 84 samples h−1, producing wastewaters of low toxicity. The proposed method offers the advantage of simplicity, accuracy, applicability to coloured and turbid samples, and automation feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On-chip debug (OCD) features are frequently available in modern microprocessors. Their contribution to shorten the time-to-market justifies the industry investment in this area, where a number of competing or complementary proposals are available or under development, e.g. NEXUS, CJTAG, IJTAG. The controllability and observability features provided by OCD infrastructures provide a valuable toolbox that can be used well beyond the debugging arena, improving the return on investment rate by diluting its cost across a wider spectrum of application areas. This paper discusses the use of OCD features for validating fault tolerant architectures, and in particular the efficiency of various fault injection methods provided by enhanced OCD infrastructures. The reference data for our comparative study was captured on a workbench comprising the 32-bit Freescale MPC-565 microprocessor, an iSYSTEM IC3000 debugger (iTracePro version) and the Winidea 2005 debugging package. All enhanced OCD infrastructures were implemented in VHDL and the results were obtained by simulation within the same fault injection environment. The focus of this paper is on the comparative analysis of the experimental results obtained for various OCD configurations and debugging scenarios.