7 resultados para professional standard
em Instituto Politécnico do Porto, Portugal
Resumo:
Dissertação apresentada ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Gestão das Organizações, Ramo de Gestão de Empresas Orientada por Prof. Doutora Maria Alexandra Pacheco Ribeiro da Costa Esta dissertação inclui as críticas e sugestões feitas pelo júri.
Resumo:
The structural integrity of multi-component structures is usually determined by the strength and durability of their unions. Adhesive bonding is often chosen over welding, riveting and bolting, due to the reduction of stress concentrations, reduced weight penalty and easy manufacturing, amongst other issues. In the past decades, the Finite Element Method (FEM) has been used for the simulation and strength prediction of bonded structures, by strength of materials or fracture mechanics-based criteria. Cohesive-zone models (CZMs) have already proved to be an effective tool in modelling damage growth, surpassing a few limitations of the aforementioned techniques. Despite this fact, they still suffer from the restriction of damage growth only at predefined growth paths. The eXtended Finite Element Method (XFEM) is a recent improvement of the FEM, developed to allow the growth of discontinuities within bulk solids along an arbitrary path, by enriching degrees of freedom with special displacement functions, thus overcoming the main restriction of CZMs. These two techniques were tested to simulate adhesively bonded single- and double-lap joints. The comparative evaluation of the two methods showed their capabilities and/or limitations for this specific purpose.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria sob orientação da Doutora Alcina Portugal Dias
Resumo:
Para garantir que um equipamento opere com segurança e fiabilidade durante o seu ciclo de vida, desde a sua instalação ao desmantelamento, devem ser realizadas inspeções e/ou monitorizações que, dependendo dos dados recolhidos, podem implicar avaliações Fitness- For-Service (FFS) que definirão a necessidade de reparação ou alteração do equipamento ou das condições processuais. A combinação de inspeção ou monitorização com os melhores procedimentos e técnicas de avaliação atuais fazem sobressair insuficiências dos procedimentos mais antigos. Usando métodos mais avançados de avaliação, validados e suportados através de uma vasta experiência de campo, pode-se agora avaliar defeitos nos ativos (equipamentos) e determinar a adequação ao serviço com uma análise FFS. As análises FFS tornaram-se cada vez mais aceites em toda a indústria ao longo dos últimos anos. A norma API 579 - 1/ASME FFS-1: 2007 fornece diretrizes para avaliar os tipos de danos que afetam os equipamentos processuais e a norma API RP 571: 2011 descreve os mecanismos de degradação que afetam os equipamentos nas petroquímicas e refinarias, que incluem os danos por corrosão, desalinhamentos, deformações plásticas, laminações, fissuras, entre outros. Este trabalho consiste na análise de Integridade Estrutural de uma Flare Industrial que surgiu da necessidade real de análise do equipamento no âmbito da atividade profissional do candidato. O estudo realizado a nível profissional é de grande abrangência, incluindo a inspeção do equipamento, identificação da falha ou dano, recolha e registo de dados, definição de estratégia de atuação e seleção de técnicas de avaliação da condição para posterior alteração, reparação ou desmantelamento. Na presente dissertação de mestrado em Engenharia Mecânica, Ramo Construções Mecânicas, pretende-se efetuar o estudo aprofundado de uma das etapas de projeto, nomeadamente estudar a causa, avaliar a falha e implicações estruturais ou processuais devido à degradação interior do riser de uma flare, com base numa análise FFS, assumindo a operabilidade em segurança e garantindo resolutas condições de funcionamento. A presente análise FFS tem como finalidade validar ou não a integridade atual (avaliação técnica quantitativa) de modo a conhecer se o item em questão é seguro e confiável para continuar a operar em condições específicas durante um período de tempo determinado, tendo em consideração as condições verificadas no ato de inspeção e especificações de projeto, segundo os itens de verificação de segurança estabelecidos na norma EN 1990:2002/A1:2005/AC:2010 e com base na norma API 579-1/ASME FFS-1: 2007. No âmbito do presente trabalho foram realizadas as seguintes tarefas: - Identificar e analisar os mecanismos de degradação com base na norma API RP 571: 2011, face às condições processuais e geométricas que o equipamento em análise está sujeito de modo a perceber a evolução da degradação estrutural e quais as implicações na sua longevidade. - Avaliar e propor soluções de reparação e ou alterações processuais e ou geométricas do equipamento em análise de modo a permitir a continuidade em funcionamento sem afetar as condições de segurança e por conseguinte minimizar ou evitar o elevado custo económico associado a um novo equipamento e tempo de paragem processual. - Assumir limites estruturais face às condições processuais e ações externas ou adjacentes. - Garantir a segurança e qualidade da vida humana ou meio que o rodeia, do equipamento, das instalações, das infraestruturas envolventes e evitar o colapso económico, quer por motivos processuais, quer indeminizações ou agravamento do prémio do seguro. Verificou-se que os resultados serão a base para as alterações inerentes, tais como reforço estrutural, alteração da geometria do defletor, ajuste no tensionamento dos cabos e controlo da espessura mínima, de modo a alargar o período de vida útil da flare com segurança.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
Teaching robotics to students at the beginning of their studies has become a huge challenge. Simulation environments can be an effective solution to that challenge where students can interact with simulated robots and have the first contact with robotic constraints. From our previous experience with simulation environments it was possible to observe that students with lower background knowledge in robotics where able to deal with a limited number of constraints, implement a simulated robotic platform and study several sensors. The question is: after this first phase what should be the best approach? Should the student start developing their own hardware? Hardware development is a very important part of an engineer's education but it can also be a difficult phase that could lead to discouragement and loss of motivation in some students. Considering the previous constraints and first year engineering students’ high abandonment rate it is important to develop teaching strategies to deal with this problem in a feasible way. The solution that we propose is the integration of a low-cost standard robotic platform WowWee Rovio as an intermediate solution between the simulation phase and the stage where the students can develop their own robots. This approach will allow the students to keep working in robotic areas such as: cooperative behaviour, perception, navigation and data fusion. The propose approach proved to be a motivation step not only for the students but also for the teachers. Students and teachers were able to reach an agreement between the level of demand imposed by the teachers and satisfaction/motivation of the students.
Resumo:
Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.