16 resultados para evaporation crystallization
em Instituto Politécnico do Porto, Portugal
Resumo:
In the last but one census of the population in the US, I had to respond as a foreigner resident, and when I was asked about my race, I chose to answer the ways I had heard the activists of the civil rights movement used to do in the US, when color blindness was an important thing to fight for – to “RACE” I added “HUMAN”...
Resumo:
In recent years ionic liquids (ILs) have been increasing the popularity and the number of applications. Ionic liquids were used mainly as solvent in organic synthesis, but in recent years they are also used in analytical chemistry, separation chemistry and material science. Additional to significant developments in their chemical properties and applications, ionic liquids are now bringing unexpected opportunities at the interface of chemistry with the life sciences. Ionic liquids (ILs) are currently defined as salts that are composed solely of cations and anions which melt below 100ºC. Our goal in this work is to explore the dual activity of the ionic liquids, due to the presence of two different ions, an anion with bacterial activity as β-lactam antibiotics and different kinds of cations. In this work the anions of ILs and salts were derived from three different antibiotics: ampicillin, penicillin and amoxicillin. The cations were derived from substituted ammonium, phosphonium pyridinium and methylimidazolium salts, such as: tetraethyl ammonium, trihexiltetradecilphosphonium, cetylpyridinium, choline (an essential nutrient), 1-ethyl-3-methylimidazolium, and 1-ethanol-3-methyl imidazolium structures. Commercial ammonium and phosponium halogen salts were first transformed into hydroxides on ionic exchange column (Amberlite IRA-400) in methanol. The prepared hydroxides were then neutralized with β-lactam antibiotics. After crystallization we obtained pure ILs and salts containing β-lactam antibiotics. This work presents a novel method for preparation of new salts of antibiotics with low melting point and their chemistry and microbiological characterization.
Resumo:
With the increase of bacterial resistance a large number of therapeutic strategies have been used to fight different kind of infections. In recent years ionic liquids (ILs) have been increasing the popularity and the number of applications. First ionic liquids were used mainly as solvent in organic synthesis, but now they are used in analytical chemistry, separation chemistry and material science among others. Additional to significant developments in their chemical properties and applications, ionic liquids are now bringing unexpected opportunities at the interface of chemistry with the life sciences Ionic liquids (ILs) are currently defined as salts that are composed solely of cations and anions which melt below 100ºC. Our goal in this work is to explore the dual activity of the ionic liquids, due to the presence of two different ions, an ion with bacterial activity as a beta-lactam antibiotic and different kinds of cations. In this work the anions of ILs and salts were derived from three different antibiotics: ampicillin, penicillin and amoxicillin. The cations were derived from substituted ammonium, phosphonium pyridinium and methylimidazolium salts, such as: tetraethyl ammonium, trihexiltetradecilphosphonium, cetylpyridinium, choline (an essential nutrient), 1-ethyl-3-methylimidazolium, and 1-ethanol-3-methyl imidazolium structures. Commercial ammonium and phosponium halogen salts were first transformed into hydroxides. on ionic exchange column (Amberlite IRA-400) in methanol. The prepared hydroxides were then neutralized with beta-lactam antibiotics. After crystallization we obtained pure ILs and salts containing beta-lactam antibiotics. This work presents a novel method for preparation of new salts of antibiotics with low melting point and their characterization.
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
O objectivo do presente trabalho foi caracterizar os condensados produzidos numa fábrica de pasta para papel para identificar e localizar pontos da sua contaminação. Para o efeito, foram recolhidas amostras de condensado e caracterizados os parâmetros condutividade, pH, sódio e sílica. A amostragem decorreu no período entre 15 de Setembro a 6 de Novembro de 2008. Através da análise dos resultados obtidos para as concentrações de sílica e de sódio de cada uma das correntes, foram identificadas como contaminadas as correntes de condensado provenientes do condensador do Turbogerador 4, da área dos Digestores Descontínuos, da Evaporação e do Aquecedor de Água Quente para o Branqueamento. A realização de um balanço pontual à sílica no tanque de condensados da Central permitiu concluir que a maior contribuição advém do condensador do Turbogerador 4. Na Evaporação ocorre contaminação do condensado quando as secções do Concentrador 1 são colocadas em serviço após lavagem. Durante o acompanhamento do arranque da Evaporação, uma das secções (1/B) registou um valor máximo na concentração de sódio no condensado de 135 mg/L Na. Do estudo resulta, enquanto não for reparado e/ou substituído o equipamento responsável pelas contaminações, a necessidade de admitir requisitos para controlo da qualidade da água da caldeira menos restritivos, nomeadamente para a razão sódio/fosfato. É necessário, contudo, o rigoroso acompanhamento da qualidade da água da caldeira (pH, sobretudo) para prevenir afastamentos inesperados dos limites de controlo. Durante a realização deste trabalho foram identificadas algumas situações a melhorar, tais como a uniformização dos valores de desvio para esgoto dos condensados e das unidades utilizadas, a adequação das escalas dos aparelhos de medida para as gamas de leitura de interesse, a verificação e calibração periódica do equipamento instalado em linha, a adopção do parâmetro “Sódio” para controlo da qualidade dos condensados, a instalação de sistemas de amostragem com arrefecimento em todas as correntes de condensados e a reparação ou substituição de algum equipamento instalado em linha que se encontra em muito mau estado e ainda a manutenção do equipamento mantendo-o em boas condições de limpeza.
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
Neste trabalho estudou-se um compósito de gesso FGD reforçado com fibras vegetais. As fibras utilizadas neste estudo são provenientes de bambu da espécie Phyllostachys edulis e foram trituradas até se obter uma granulometria apropriada à composição de uma pasta de gesso que permitisse a execução de placas de gesso laminado. As placas produzidas foram ensaiadas à flexão e posteriormente submetidas à análise de humidade para aferir a percentagem de água de cristalização nas amostras. Foram ainda produzidos provetes cúbicos com 7cm de aresta para permitira a execução de ensaio à compressão. Foram produzidos dois tipos de pastas, uma sem a adição de partículas de bambu (controlo) e outra com adição de 15% de partículas de bambu.
Resumo:
In this work we employed a hybrid method, combining RF-magnetron sputtering with evaporation, for the deposition of tailor made metallic precursors, with varying number of Zn/Sn/Cu (ZTC) periods and compared two approaches to sulphurization. Two series of samples with 1×, 2× and 4× ZTC periods have been prepared. One series of precursors was sulphurized in a tubular furnace directly exposed to a sulphur vapour and N2+5% H2 flux at a pressure of 5.0×10+4 Pa. A second series of identical precursors was sulphurized in the same furnace but inside a graphite box where sulphur pellets have been evaporated again in the presence of N2+5% H2 and at the same pressure as for the sulphur flux experiments. The morphological and chemical analyses revealed a small grain structure but good average composition for all three films sulphurized in the graphite box. As for the three films sulphurized in sulphur flux grain growth was seen with the increase of the number of ZTC periods whilst, in terms of composition, they were slightly Zn poor. The films' crystal structure showed that Cu2ZnSnS4 is the dominant phase. However, in the case of the sulphur flux films SnS2 was also detected. Photoluminescence spectroscopy studies showed an asymmetric broad band emission whichoccurs in the range of 1–1.5 eV. Clearly the radiative recombination efficiency is higher in the series of samples sulphurized in sulphur flux. We have found that sulphurization in sulphur flux leads to better film morphology than when the process is carried out in a graphite box in similar thermodynamic conditions. Solar cells have been prepared and characterized showing a correlation between improved film morphology and cell performance. The best cells achieved an efficiency of 2.4%.
Resumo:
Cu2ZnSnSe4 (CZTSe) is a p-type semiconductor with a high absorption coefficient, 104 to 105 cm-1, and is being seen as a possible replacement for Cu(In,Ga)Se2 in thin film solar cells. Yet, there are some fundamental properties of CZTSe that are not well known, one of them is its band gap. In order to resolve its correct value it is necessary to improve the growth conditions to ensure that single phase crystalline thin films are obtained. One of the problems encountered when growing CZTSe is the loss of Sn through evaporation of SnSe. Stoichiometric films are then difficult to obtain and usually there are other phases present. One possible way to overcome this problem is to increase the pressure of growth of CZTSe. This can be done by introducing an atmosphere of an inert gas like Ar or N2. In this work we report the results of morphological, structural and optical studies of the properties of CZTSe thin films grown by selenization of DC magnetron sputtered metallic layers under different Ar pressures. The films are analysed by SEM/EDS, Raman scattering and XRD.
Resumo:
Mestrado em Engenharia Mecânica – Ramo Energia
Resumo:
A indústria de curtumes é fortemente geradora de resíduos sólidos e águas residuais pelo que a necessidade de criar alternativas para a sua valorização e minimização é premente e constante. Este trabalho teve, como principal objectivo, o aproveitamento da raspa tripa, resíduo da indústria de curtumes. Para tal, a raspa tripa foi sujeita a um processo de hidrólise térmica e/ou enzimática para obtenção de gordura e hidrolisado proteico. Na hidrólise da raspa tripa foi estudada a influência de vários factores como a quantidade de enzima e de água, a temperatura e o tempo. Constatou-se que foi para a temperatura de 60ºC, um tempo de quatro horas, uma quantidade de 2% de enzima e 100% de água, relativamente à massa de raspa utilizada, que se obteve o melhor resultado com um rendimento de extracção de 93%. A partir da gordura obtida foram produzidos óleos por sulfatação e sulfitação, designados por óleos sulfatados e sulfitados, respectivamente. O hidrolisado proteico obtido foi concentrado por evaporação para aumentar o seu teor de sólidos totais. Com este foram produzidos gluproteicos e fillers, por acção de glutaraldeído e do efeito sinérgico de outros produtos. Os óleos, o hidrolisado concentrado e seus derivados foram testados no processo de engorduramento e recurtume do couro. A avaliação dos resultados foi realizada por comparação dos resultados dos testes físico-mecânicos das amostras de pele obtidas com valores de referência e por comparação com um ensaio padrão em que se utilizaram produtos de referência do mercado. Os resultados foram muitos satisfatórios visto que foram superiores aos valores de referência e também superiores aos valores obtidos para o padrão salvo raras excepções. Reconheceu-se assim a aplicabilidade destes produtos no processo de recurtume e engorduramento que também corresponderam no que respeita a características importantes do couro como a firmeza de flor e o toque. No decorrer do trabalho constatou-se que as peles tratadas com hidrolisado proteico apresentavam uma cor mais intensa, pelo que se efectuou um estudo de colorimetria através do método CIELAB. Comprovou-se que o hidrolisado proteico e os gluproteicos quando utilizados no processo de recurtume, por substituição do Fortan A40, intensificam a cor da pele. A valorização da raspa tripa resulta numa dupla vantagem para a indústria dos curtumes. Se por um lado diminui o impacto ambiental que esta origina, por outro lado possibilita a produção de produtos que podem ser substitutos de outros produtos químicos que têm que ser adquiridos por esta indústria.
Resumo:
A presente dissertação tem dois objetivos, o primeiro é a realização de uma auditoria energética e avaliação da qualidade do ar às instalações de uma Piscina Municipal, permitindo a sua classificação energética, e o segundo é o estudo de propostas de melhoria que contribuam para uma melhor eficiência energética do edifício. Na análise à qualidade do ar interior os parâmetros avaliados encontravam-se todos dentro dos limites estabelecidos por lei, com exceção dos valores de COVs que em dois pontos de medição (ambos na nave) ultrapassaram os limites estabelecidos por lei. A auditoria ao edifício permitiu verificar que o caudal mínimo de água nova nas piscinas imposto por lei é cumprido pela instalação. No que diz respeito ao caudal de ar novo introduzido, este apenas é respeitado quando a unidade de tratamento de ar está a debitar 100% da sua capacidade. Quando a unidade opera a 50% da sua capacidade apresenta um défice de 5% do valor mínimo estabelecido. Relativamente às perdas energéticas associadas aos tanques de natação, estas apresentam um valor de 95,89 kW, em que 59,09 kW dizem respeito às perdas por evaporação. Foi também possível concluir que as perdas por evaporação representam cerca de 39% da energia calorifica produzida nas caldeiras. O edifício apresenta um consumo anual de eletricidade de 166 482 kWh em que 69% deste valor é provocado pelas unidades de tratamento de ar e a iluminação apresenta apenas um peso de 3%. Em relação ao gás natural consumido pelas caldeiras o seu valor anual é de 1 317 240 kWh. A simulação dinâmica do edifício permitiu concluir que este apresenta um IEE de 1 269,9 kWh/m2.ano. O rácio de classe energética (RIEE) é de 1,24 o que significa que o edifício pertence à classe energética C. As medidas estudadas para a melhoria da eficiência energética, nomeadamente integração energética com uma central de ciclo combinado, aplicação de cobertura isotérmica nas piscinas e substituição do telhado na zona da nave, mostraram-se viáveis. O estudo da possibilidade da realização de uma integração energética permitiu concluir que a poupança anual é de 9 374 € e o investimento é recuperado em menos de 1,5 anos. Relativamente à aplicação de cobertura isotérmica o investimento é de 14 000 € e é recuperado em 2 anos. A substituição do telhado na zona da nave tem um investimento de 20 500 € e a recuperação realiza-se num período de 3,5 anos.
Resumo:
The opto-electronic properties of copper zinc tin sulfide can be tuned to achieve better cell efficiencies by controlled incorporation of selenium. In this paper we report the growth of Cu2ZnSn(S,Se)4 (CZTSSe) using a hybrid process involving the sequential evaporation of Zn and sputtering of the sulfide precursors of Cu and Sn, followed by a selenization step. Two approaches for selenization were followed, one using a tubular furnace and the other using a rapid thermal processor. The effects of annealing conditions on the morphological and structural properties of the films were investigated. Scanning electron microscopy and energy dispersive spectroscopy were employed to investigate the morphology and composition of the films. Structural analyses were done using X-ray diffraction (XRD) and Raman spectroscopy. Structural analyses revealed the formation of CZTSSe. This study shows that regardless of the selenization method a temperature above 450 °C is required for conversion of precursors to a compact CZTSSe layer. XRD and Raman analysis suggests that the films selenized in the tubular furnace are selenium rich whereas the samples selenized in the rapid thermal processor have higher sulfur content.
Resumo:
Until this day, the most efficient Cu(In,Ga)Se2 thin film solar cells have been prepared using a rather complex growth process often referred to as three-stage or multistage. This family of processes is mainly characterized by a first step deposited with only In, Ga and Se flux to form a first layer. Cu is added in a second step until the film becomes slightly Cu-rich, where-after the film is converted to its final Cu-poor composition by a third stage, again with no or very little addition of Cu. In this paper, a comparison between solar cells prepared with the three-stage process and a one-stage/in-line process with the same composition, thickness, and solar cell stack is made. The one-stage process is easier to be used in an industrial scale and do not have Cu-rich transitions. The samples were analyzed using glow discharge optical emission spectroscopy, scanning electron microscopy, X-ray diffraction, current–voltage-temperature, capacitance-voltage, external quantum efficiency, transmission/reflection, and photoluminescence. It was concluded that in spite of differences in the texturing, morphology and Ga gradient, the electrical performance of the two types of samples is quite similar as demonstrated by the similar J–V behavior, quantum spectral response, and the estimated recombination losses.