56 resultados para eficiência de remoção

em Instituto Politécnico do Porto, Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The goal of this work was the treatment of polluted waste gases in a bubble column reactor (BCR), in order to determinate the maximum value of reactor’s efficiency (RE), varying the inlet concentration (C in) of the pollutants. The gaseous mixtures studied were: (i) air with styrene and (ii) air with styrene and acetone. The liquid phase used to contain the biomass in the reactor was a basal salt medium (BSM), fundamental for the microorganisms’ development. The reactor used in this project consists of a glass column of 620mm height and inside diameter 75mm. In all essays there were continually measured: pH, dissolved oxygen and liquid’s temperature. Temperature and pH were controlled (T=24ºC, 7.0 ≤ pH ≤ 7.7). In all experiments the liquid volume (including the biomass) used in the reactor was kept constant (1.5L) as well as the total gas flowrate (1 L/min). Concerning the goal of the work, some parameters were calculated: the organic load (OL), removal efficiency (RE), elimination capacity (EC), biomass concentration (xf) and dry biomass concentration (Xdw). In a first series of experiments, the gas mixture used was air with styrene, varying its concentration from 191 mg.m-3 to 6500 mg.m-3.It was concluded that the RE maximum value (97%) was obtained for C in Sty = 4200 mg.m-3. For the maximum tested value of C in Sty, RE obtained was 20%. In a second step, the gaseous mixture included acetone, varying C in Sty between 225 mg.m-3 and 2659 mg.m-3 and C in Ac between 153mg.m-3 and 1389 mg.m-3. The aim of these tests was the determination of C in Ac for which RE was maximum, obtaining C in Ac = 750 mg.m-3. A third series of experiments was performed, in which C in Ac was maintained equal to that value and C in Sty was varied until higher values (5422 mg.m-3). RE maximum values obtained in this last series were 100% for styrene and 40% for acetone. One important conclusion is the fact that the microorganisms available degrade better styrene than acetone. On the ambit of this study, it was possible to identify the species available in biomass: Xanthobacter antotrophicus py2, Enterobacter aerogenes, Nocardia, Corynebacterium Spp., Rhodococcus rhodochrous e Pseudomonas Sp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo deste trabalho é a análise da eficiência produtiva e dos efeitos da concentração sobre os custos bancários, tendo por base a indústria bancária portuguesa. O carácter multiproduto da empresa bancária sugere a necessidade de se adoptar formas multiproduto da função custo (tipo Fourier). Introduzimos variáveis de homogeneidade e de estrutura que permitem o recurso a formas funcionais uniproduto (Cobb-Douglas) à banca. A amostra corresponde a 22 bancos que operavam em Portugal entre 1995-2001, base não consolidada e dados em painel. Para o estudo da ineficiência recorreu-se ao modelo estocástico da curva fronteira (SFA), para as duas especificações. Na análise da concentração, introduziram-se variáveis binárias que pretendem captar os efeitos durante quatro anos após a concentração. Tanto no caso da SFA como no da concentração, os resultados encontrados são sensíveis à especificação funcional adoptada. Concluindo, o processo de concentração bancário parece justificar-se pela possibilidade da diminuição da ineficiência-X. This study addresses the productive efficiency and the effects of concentration over the banking costs, stressing its focus on the Portuguese banking market. The multiproduct character of the banking firm suggests the use of functional forms as Fourier. The introduction of variables of structure and of homogeneity allows the association of the banking activity (multiproduct) with a single product function (Cobb-Douglas type). The sample covers 22 banks which operated in Portugal from 1995-2001, non consolidated base with a panel data structure. The study about inefficiency is elaborated through the stochastic frontier model (SFA), for the two specifications selected. As a methodology to analyze the concentration, we introduced binary variables, which intend to catch the effects through four years after the concentration process. The results obtained, through SFA and concentration approach, are influenced by the kind of specifications selected. Summing up, the concentration process of the Banking Industry sounds to be justified by the possibility of the X-inefficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo optimização energética na indústria química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A avaliação das organizações e a deterntinação da performance obtida pelo exercício da gestão, tem sido uma preocupação constante de gestores e accionistas, embora com objectivos diversos. Nos dias de hoje, a questão coloca-se com maior acuidade quer pela competitividade acrescida quer pela dimensão e complexidade actual das empresas. Pretendemos com este trabalho fazer uma descrição da metodologia DEA - Data Envelopment Analysis - nas suas formulações iniciais mais simples. A metodologia do DEA, pretende obter uma medida única e simples de avaliação da eficiência, combinando um conjunto de outputs e de inputs relativos às diferentes unidades homogéneas que se pretendem avaliar. O método DEA é um método não paramétrico que pelas suas características é particularmente adequado à avaliação de unidades homogéneas não necessariamente lucrativas. Concluímos, em geral, que são úteis e constituem um avanço importante, as informações obtidas através do DEA mas que outros métodos, designadamente rácios e análises de regressão, podem dar um contributo importante para complementar aquela análise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química.Ramo optimização energética na indústria química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na Fábrica de Papel da Ponte Redonda fabricam-se sacos de papel multi-folhas e papel reciclado do tipo Kraft. Tendo em consideração a primeira actividade, é de grande interesse optimizar o processo de fabrico de papel com vista a incorporara a máxima taxa de papel produzido internamente nas diferentes camadas dos sacos de papel. Os papéis de maior interesse são os do tipo Fluting e Liners, tendo sido produzidos em 2010 um total de 4,9 mil toneladas, ou seja 90% de todo o papel fabricado em 2010, correspondendo a a 4 mil toneladas de papéis do tipo Liners e 0,9 mil toneladas para os papéis do tipo Fluting. Nos papéis do tipo Liners incluem-se os papéis do tipo Test-Liner e Kraft-Liner, representando em termos produtivos valores idênticos. No âmbito deste trabalho, em que se pretendeu controlar as águas do processo e optimizar a produção de papel, foram introduzidos uma unidade de flutuação e um sistema que permitisse regular a consistência da suspensão fibrosa à entrada da máquina do papel, e foram ainda estudadas as possibilidades de adição de produtos químicos para melhorar as características da pasta assim como um tratamento microbiológico mais eficaz para todo o processo. Para se avaliar se as medidas implementadas teriam um impacto positivo na qualidade desses dois tipos de papéis, desenvolveu-se o trabalho em duas fases: a primeira envolve a introdução de um sistema de flutuação e de um sistema de controlo de consistência da pasta, assim como a selecção de produtos químicos a adicionar ao processo. A segunda fase consistiu na avaliação do efeito destas medidas nas características do papel fabricado. Para o efeito foram escolhidos dois tipos de papel e de diferentes gramagens, nomeadamente Test-Liner de 80 g/m2 e Fluting de 110 g/m2. Introduziu-se um flutuador com o objectivo de tratar parte das águas do processo de fabrico com vista a serem reutilizadas em determinadas aplicações possíveis para a qualidade da água obtida (lavagens e água do processo), de modo a conseguir-se uma poupança de água, assim como aproveitar-se as lamas resultantes, ricas em fibra de celulose, para utilizá-las como matéria-prima. Foi introduzido um regulador de consistência no processo da Ponte Redonda com o objectivo de alimentar de uma forma constante a consistência da pasta à entrada da máquina do papel proporcionando uma melhor formação da folha, devido à ligação entre fibras, na direcção máquina e direcção transversal. Esse sistema inovador é um Regulador de Consistência que vem proporcionar à máquina do papel uma alimentação em fibra mais constante. O fabrico de papel apenas a partir de fibras de celulose não permitirá obter um papel com as características desejadas para a sua utilização. Para corrigir estas deficiências, são adicionados produtos químicos para atribuir ou melhorar as propriedades dos papéis. Desta forma considerou-se interessante introduzir no processo um agente de retenção numa fase posterior à preparação da pasta e antes da chegada à máquina de papel, de forma a melhorar as características da suspensão fibrosa. Assim foi implementado um sistema cuja eficácia foi avaliada. Concluiu-se que com a sua implementação a máquina de papel apresentou melhores resultados na drenagem e na turbidez da água removida, significando uma água com menor teor de matéria suspensa e dissolvida, devido à melhor agregação das fibras dispersas na suspensão fibrosa, levando a um aumento da drenagem e consequentemente melhor eficiência das prensas e secaria. Foi também elaborado um estudo para introdução de um sistema de tratamento microbiológico em todo o processo de fabrico de papel, devido à existência de microorganismos prejudiciais ao seu fabrico. Concluiu-se que a água clarificada proveniente do flutuador apresentou qualidade aceitável para os objectivos pretendidos. No entanto, considerando a eficiência de 26,5% na remoção de sólidos suspensos será necessário mais algum tempo de utilização da água clarificada, cerca de um ano, para avaliar se esta terá algum efeito prejudicial nos equipamentos. Verificou-se que devido à existência de microrganismos em todo o processo de fabrico de papel será necessário efectuar lavagens aos tinões, tanques e circuitos com alguma regularidade, aproveitando-se as paragens do processo assim como implementar um sistema de tratamento microbiológico mais eficaz. Em resultado das medidas implementadas concluiu-se que os papéis produzidos apresentaram melhorias, tendo-se obtido melhores resultados em todos os ensaios de resistência. No papel do tipo Test-Liner destacam-se os bons resultados nos ensaios de superfície, Cobb60 e rebentamento. No caso do parâmetro do Cobb60, foi um resultado surpreendente visto que por norma este tipo de papéis reciclados não suportam este ensaio. Concluiu-se também que as medidas implementadas proporcionaram uma melhor agregação e ligação entre fibras, e melhor formação da folha na máquina do papel proporcionando aos papéis propriedades físico-mecânicas mais interessantes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho, elaborado entre Fevereiro e Julho de 2011, pretendeu analisar o impacto de algumas estratégias de optimização, adoptadas no âmbito da gestão de processo. As soluções estudadas tiveram como objectivo fazer face a alguns problemas de funcionamento da estação de tratamento de águas residuais (ETAR) de Crestuma, com recurso aos meios existentes. Para esse efeito foi realizada uma análise ao histórico dos registos de exploração referentes ao período de Janeiro de 2008 a Julho de 2011, pois foi considerado que este seria o período necessário para a análise e apuramento de resultados conclusivos. A ETAR fica situada na freguesia de Crestuma, actualmente com 2619 habitantes, localizada na confluência do regato de Vessadas com o rio Douro. Destina-se a tratar as águas residuais provenientes do sistema de drenagem de três localidades, S. Fioso, S. Picoto e S. Vessada, contribuindo para a despoluição do rio Douro. Genericamente, a ETAR tem apresentado um desempenho bastante satisfatório, respeitando os valores limites de emissão previstos na legislação actual (Decreto-Lei 152/97). A permanência de grandes quantidades de lama no processo, associada a uma elevada idade das lamas, está na origem da sua má sedimentabilidade, dificultando, por sua vez, a sua remoção do sistema. Com objectivo de se conseguir remover as lamas biológicas de uma forma mais eficiente, foi adoptada uma estratégia que compreendeu duas etapas. Com a finalidade de melhorar a sedimentabilidade, numa primeira etapa foi introduzido no processo um produto biológico, composto essencialmente por fungos, comercialmente conhecido por Optibiom 7450L. Com vista a obter-se uma maior eficiência na desidratação das lamas, a segunda etapa consistiu na substituição do polímero usado na lama espessada, por outro, de composição diferente, comercialmente conhecido por Easy 6040. Com as alterações introduzidas, foi possível obter um melhor controlo do processo e convergir para parâmetros de funcionamento mais próximos dos valores referidos na bibliografia. As alterações mais relevantes foram verificadas nos valores de sólidos suspensos totais (SST) no reactor biológico e na recirculação, tendo-se obtido valores médios de 3846 e 9716 mg/L, respectivamente (correspondendo a valores anteriores ao tratamento de 5301 e 7430 mg/L). Assim, a razão entre as concentrações de SST na corrente de recirculação e no reactor biológico passou de 1,4 para 2,6. A idade das lamas diminuiu de 42 para 36 dias com a adição do polímero Easy 6040 e o índice volumétrico de lamas apresentou uma redução, de 134 mL/g para 100 mL/g, o que se traduziu numa melhor sedimentabilidade das lamas. Desta forma, obteve-se uma diminuição de 33,3% no volume de lama produzida por m3 de afluente tratado, bem como uma redução de 27% no número de horas de funcionamento da centrífuga e um decréscimo ligeiro no consumo global de energia da ETAR (0,89%). Conclui-se que as alterações introduzidas no processo, adição de um produto biológico composto por fungos (Optibiom 7450L) e substituição do polímero usado na lama espessada por outro de composição diferente (Easy 6040), conduziram a uma melhoria no funcionamento do tratamento biológico da ETAR de Crestuma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devido à crescente preocupação com a racionalização energética, torna-se importante adequar os edifícios à sua utilização futura, procedendo à escolha acertada de materiais e técnicas a utilizar na construção e/ou na remodelação. Atualmente, com o desenvolvimento tecnológico, os serviços profissionais e os materiais existentes ao dispor dos projectistas e construtores permitem a implementação eficaz de soluções de elevado impacto a nível da eficiência energética dos edifícios de uma forma acessível e não muito dispendiosa. Nesta área, a regulamentação é essencial para controlar e catalogar energeticamente os sistemas, mitigando o seu sobredimensionamento e consequentes desperdícios, de forma a contribuir eficazmente para as melhorias ambientais e económicas pretendidas. Sem dúvida, que a preocupação consiste em tornar a médio/longo prazo o investimento numa poupança acrescida, proporcionando os mesmos níveis de conforto. As técnicas de climatização e todo o equipamento que está associado têm um peso importante nos custos e na exploração ao longo do tempo. Os sistemas de gestão técnica só poderão tirar partido de toda a estrutura, tornando-a confiável, se forem corretamente projetados. Com este trabalho, pretende-se sensibilizar o leitor sobre as questões práticas associadas ao correto dimensionamento de soluções que contribuam para a eficiência energética dos edifícios, exemplificando-se com um caso de estudo: um edifício de um centro escolar construído obedecendo aos requisitos listados no programa de renovação do parque escolar que o governo incentivou. A sensibilização passa por propostas objetivas de soluções alternativas que poderiam ter sido adotadas ainda na fase de projeto do caso de estudo, tendo em conta os custos e operacionalidade dos sistemas e o local em que se encontram, e que poderiam ter contribuído para melhorar a eficiência energética de todo o edifício, bem como por soluções transversais que se poderiam aplicar em outras situações. Todas as sugestões passam pela simplificação, com o objetivo de contribuir para uma melhor racionalização a curto e longo prazo dos recursos disponibilizados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A iluminação pública é responsável por 3% do consumo de energia elétrica, em Portugal, tendo havido um crescimento no consumo de energia elétrica neste setor, entre 2000 e 2011, de cerca de 55%, com uma taxa média de crescimento anual de cerca de 5,1%. No ano de 2011, os custos com a iluminação pública rondaram os 170 M€, sendo que grande parte foram assegurados pelos Municípios. Atendendo ao panorama financeiro delicado de grande parte das autarquias do País, e sabendo que a iluminação pública tem um peso considerável nas despesas anuais de energia, faz sentido que se concentre aqui um esforço para tornar mais eficientes estas instalações. A nível nacional, a Estratégia Nacional para a Energia 2020 (ENE 2020) define estratégias que visam o cumprimento das medidas impostas pela União Europeia no sentido de cumprir objetivos que respeitem a sustentabilidade A ENE 2020 define uma agenda para a competitividade, o crescimento e a independência energética e financeira do país através da aposta nas energias renováveis e da promoção integrada da eficiência energética, assegurando a segurança de abastecimento e a sustentabilidade económica e ambiental do modelo energético. Um dos eixos em que se divide a ENE 2020 visa diretamente a promoção da eficiência energética na Iluminação Pública (IP), com o objetivo de promover e apoiar projetos inovadores de iluminação pública com prioridade para os centros históricos. Existem no mercado diversas soluções e tecnologias que permitem melhorar a eficiência energética da IP, facilitando uma gestão mais eficiente. Estes sistemas podem também permitir economias diretas nos consumos de energia e/ou levar a um aumento da vida útil das lâmpadas, permitindo uma redução dos custos de manutenção das instalações de IP.