3 resultados para dual-energy X-ray absorptometry
em Instituto Politécnico do Porto, Portugal
Resumo:
A osteoporose é uma doença crónica e progressiva. O diagnóstico baseia-se na avaliação de densidade mineral óssea (DMO), por absorciometria bifotónica por RX (DXA) e no conceito operacional da Organização Mundial de Saúde (OMS) indicando que a doença acontece para valores de DMO inferiores a 2,5 desvios-padrão do valor médio máximo para mulheres jovens, saudáveis de etnia caucasóide. Existe variabilidade nos valores de pico de massa óssea entre diferentes populações. Este estudo pretende avaliar a prevalência de osteoporose quando utilizada a base de referência do equipamento e quando utilizada a base de dados para score-T construída a partir da amostra.
Resumo:
Development of Dual Source Computed Tomography (Definition, Siemens Medical Solutions, Erlanger, Germany) allowed advances in temporal resolution, with the addition of a second X-ray source and an array of detectors to the TCM 64 slices. The ability to run exams on Dual Energy, allows greater differentiation of tissues, showing differences between closer attenuation coefficients. In terms of renal applications, the distinction of kidney stones and masses become one of the main advantages of the use of dual-energy technology. This article pretends to demonstrate operating principles of this equipment, as its main renal applications.
Resumo:
New arguments proving that successive (repeated) measurements have a memory and actually remember each other are presented. The recognition of this peculiarity can change essentially the existing paradigm associated with conventional observation in behavior of different complex systems and lead towards the application of an intermediate model (IM). This IM can provide a very accurate fit of the measured data in terms of the Prony's decomposition. This decomposition, in turn, contains a small set of the fitting parameters relatively to the number of initial data points and allows comparing the measured data in cases where the “best fit” model based on some specific physical principles is absent. As an example, we consider two X-ray diffractometers (defined in paper as A- (“cheap”) and B- (“expensive”) that are used after their proper calibration for the measuring of the same substance (corundum a-Al2O3). The amplitude-frequency response (AFR) obtained in the frame of the Prony's decomposition can be used for comparison of the spectra recorded from (A) and (B) - X-ray diffractometers (XRDs) for calibration and other practical purposes. We prove also that the Fourier decomposition can be adapted to “ideal” experiment without memory while the Prony's decomposition corresponds to real measurement and can be fitted in the frame of the IM in this case. New statistical parameters describing the properties of experimental equipment (irrespective to their internal “filling”) are found. The suggested approach is rather general and can be used for calibration and comparison of different complex dynamical systems in practical purposes.