26 resultados para chromatographic fingerprinting
em Instituto Politécnico do Porto, Portugal
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Two chromatographic methods, gas chromatography with flow ionization detection (GC–FID) and liquid chromatography with ultraviolet detection (LC–UV), were used to determine furfuryl alcohol in several kinds of foundry resins, after application of an optimised extraction procedure. The GC method developed gave feasibility that did not depend on resin kind. Analysis by LC was suitable just for furanic resins. The presence of interference in the phenolic resins did not allow an appropriate quantification by LC. Both methods gave accurate and precise results. Recoveries were >94%; relative standard deviations were ≤7 and ≤0.3%, respectively for GC and LC methods. Good relative deviations between the two methods were found (≤3%).
Resumo:
Phenol is a toxic compound present in a wide variety of foundry resins. Its quantification is important for the characterization of the resins as well as for the evaluation of free contaminants present in foundry wastes. Two chromatographic methods, liquid chromatography with ultraviolet detection (LC-UV) and gas chromatography with flame ionization detection (GC-FID), for the analysis of free phenol in several foundry resins, after a simple extraction procedure (30 min), were developed. Both chromatographic methods were suitable for the determination of phenol in the studied furanic and phenolic resins, showing good selectivity, accuracy (recovery 99–100%; relative deviations <5%), and precision (coefficients of variation <6%). The used ASTM reference method was only found to be useful in the analysis of phenolic resins, while the LC and GC methods were applicable for all the studied resins. The developed methods reduce the time of analysis from 3.5 hours to about 30 min and can readily be used in routine quality control laboratories.
Resumo:
In order to combat a variety of pests, pesticides are widely used in fruits. Several extraction procedures (liquid extraction, single drop microextraction, microwave-assisted extraction, pressurized liquid extraction, supercritical fluid extraction, solid-phase extraction, solid-phase microextraction, matrix solid-phase dispersion, and stir bar sorptive extraction) have been reported to determine pesticide residues in fruits and fruit juices. The significant change in recent years is the introduction of the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods in these matrices analysis. A combination of techniques reported the use of new extraction methods and chromatography to provide better quantitative recoveries at low levels. The use of mass spectrometric detectors in combination with liquid and gas chromatography has played a vital role to solve many problems related to food safety. The main attention in this review is on the achievements that have been possible because of the progress in extraction methods and the latest advances and novelties in mass spectrometry, and how these progresses have influenced the best control of food, allowing for an increase in the food safety and quality standards.
Resumo:
Indoor location systems cannot rely on technologies such as GPS (Global Positioning System) to determine the position of a mobile terminal, because its signals are blocked by obstacles such as walls, ceilings, roofs, etc. In such environments. The use of alternative techniques, such as the use of wireless networks, should be considered. The location estimation is made by measuring and analysing one of the parameters of the wireless signal, usually the received power. One of the techniques used to estimate the locations using wireless networks is fingerprinting. This technique comprises two phases: in the first phase data is collected from the scenario and stored in a database; the second phase consists in determining the location of the mobile node by comparing the data collected from the wireless transceiver with the data previously stored in the database. In this paper an approach for localisation using fingerprinting based on Fuzzy Logic and pattern searching is presented. The performance of the proposed approach is compared with the performance of classic methods, and it presents an improvement between 10.24% and 49.43%, depending on the mobile node and the Fuzzy Logic parameters.ł
Resumo:
Fingerprinting is an indoor location technique, based on wireless networks, where data stored during the offline phase is compared with data collected by the mobile device during the online phase. In most of the real-life scenarios, the mobile node used throughout the offline phase is different from the mobile nodes that will be used during the online phase. This means that there might be very significant differences between the Received Signal Strength values acquired by the mobile node and the ones stored in the Fingerprinting Map. As a consequence, this difference between RSS values might contribute to increase the location estimation error. One possible solution to minimize these differences is to adapt the RSS values, acquired during the online phase, before sending them to the Location Estimation Algorithm. Also the internal parameters of the Location Estimation Algorithms, for example the weights of the Weighted k-Nearest Neighbour, might need to be tuned for every type of terminal. This paper focuses both approaches, using Direct Search optimization methods to adapt the Received Signal Strength and to tune the Location Estimation Algorithm parameters. As a result it was possible to decrease the location estimation error originally obtained without any calibration procedure.
Resumo:
As sequelas fisiopatológicas do stress oxidativo são difíceis de quantificar. Apesar dos obstáculos, a relevância médica do stress oxidativo tem vindo a ser cada vez mais reconhecida, sendo hoje em dia encarado como um componente chave de virtualmente todas as doenças. A disfunção erétil (DE) surge neste contexto como uma espécie de barómetro da função endotelial e do dano oxidativo. A quantificação de biomarcadores de stress oxidativo poderá apresentar um enorme impacto na avaliação de pacientes com DE. O rácio glutationa reduzida/oxidada (GSH/GSSG) e a nitrotirosina (3-NT) têm vindo a demonstrar relevância clínica. A consideração de polimorfismos genéticos constitui ainda uma abordagem promissora na avaliação destas relações no futuro. Um método altamente sensível de cromatografia líquida de alta performance (HPLC) foi desenvolvido para a determinação de 3-NT em plasma humano. As concentrações de 3-NT medidos em indivíduos com DE foram 6,6±2,1μM (média±S.D., n = 46). A medição da concentração plasmática de 3-NT poderá revelar-se útil como marcador de dano oxidativo dependente do óxido nítrico (NO). O nível de stress oxidativo pode também ser quantificado através da medição do decréscimo do rácio GSH/GSSG, que tem mostrado alterações numa miríade de patologias, como a DE e a diabetes mellitus. O método proposto para a quantificação do rácio GSH/GSSG em HPLC apresenta a vantagem de avaliação concomitante dos dois parâmetros em apenas uma corrida. O valor do rácio GSH/GSSG obtido a partir de sangue de indivíduos com DE foi 11,9±9,8 (média±S.D., n = 49). Os resultados estatísticos revelaram diferenças significativas (p<0,001) entre ambos a concentração plasmática de 3-NT e o rácio GSH/GSSG de sangue de indivíduos com DE e as respetivas medições em indivíduos saudáveis. Observaram-se ainda diferenças estatisticamente significativas (p≈0,027) entre o rácio GSH/GSSG do sangue de pacientes apenas com diagnóstico de DE e a medição respetiva em indivíduos com DE e comorbilidades cardiovasculares. Estes resultados enfatizam o papel do dano oxidativo na biopatologia da DE, elucidado com o auxílio destas duas metodologias, que poderão ter um amplo campo de aplicação no futuro, dado que se mostraram simples, não dispendiosas e rápidas, podendo eventualmente adequar-se a estudos de rastreio em larga escala.
Resumo:
A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.
Resumo:
Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.
Resumo:
De forma a proteger o ambiente e a saúde humana, é imperativo evitar, prevenir ou reduzir as concentrações prejudiciais de poluentes nocivos na água subterrânea. A necessidade da obtenção de níveis de protecção da água subterrânea, encontra-se estabelecida em normas de qualidade e devem ser desenvolvidas metodologias que permitam a avaliação do estado químico da água subterrânea. Este trabalho experimental centrou-se no desenvolvimento de uma metodologia analítica de detecção e quantificação por cromatografia gasosa com detector de captura de electrões dos pesticidas atrazina e respectivos metabolitos (desetilatrazina e deisopropilatrazina), simazina, terbutilazina e o metabolito desetiterbutilazina, folpete, dimetoato, diazinão, malatião, cloropirifos e o azinfos-metilo em águas de poços. O estudo progressivo baseou-se na colheita de água a 20 poços agrícolas na zona de Esposende, área considerada pelo Ministério da Agricultura do Desenvolvimento Rural e Pescas como sendo uma zona vulnerável. O método utilizado para a validação da técnica cromatográfica baseou-se na norma ISO 8466-1:1990. Os parâmetros de validação considerados foram: especificidade/selectividade, capacidade de identificação, limites de detecção e quantificação, relação sinal/ruído, linearidade e curva de calibração, precisão (repetibilidade, precisão intermédia e reprodutibilidade), eficiência de extracção e arrastamento. O método demonstrou ser capaz de identificar e quantificar os analitos, sem interferência de outros compostos. Obteve-se um valor para os parâmetros da precisão inferior a 10%, enquanto os mais baixos limites de detecção e de quantificação foram, respectivamente, 0,014 e 0,047 μg L-1. Na preparação de amostras optou-se pelo método de extracção em fase sólida, tendo sido testadas cinco diferentes tipos de colunas extractivas; Lichrolut® EN/RP-18; Strata SDB-L e C18-E; Chromabond HR-P e HR-X, sendo que as colunas Lichrolut® EN/RP- 18 apresentaram melhores resultados para a globalidade dos pesticidas. Da análise efectuada aos 20 poços agrícolas verificou-se que apenas 3 não apresentavam qualquer vestígio dos pesticidas monitorizados, sendo que as restantes apresentavam valores entre 0,05 e 53,2 μg L-1, valores superiores aos impostos pela legislação em vigor (Decreto-Lei n.º 208/2008 de 28 de Outubro para água subterrânea e Decreto-Lei nº306/2007 referente a água para consumo). Verificou-se que os proprietários dos poços agrícolas, dos quais se procedeu à amostragem de água para análise não têm a consciência da falta de qualidade dessa água, nem dos malefícios que possam advir do seu consumo.
Resumo:
Este trabalho teve como objectivo pesquisar os pesticidas que são mais usados em Portugal, os métodos de análise mais frequentemente utilizados na determinação de pesticidas, a contaminação ambiental por pesticidas e como minimizar o impacto ambiental provocado pelo uso indiscriminado de pesticidas. Os pesticidas usados variam de acordo com as diferentes características das regiões de Portugal e os grupos de pesticidas mais usados são: organofosforados, derivados de anilina, derivados triazinicos, tiocarbamatos, derivados do ácido fenoxiacético, derivados de acetamida, benzotiadiazole, derivados de ureia e azol. A determinação destes grupos é usualmente feita usando métodos cromatográficos, uma vez que estes métodos permitem a separação de misturas complexas. A contaminação ambiental por pesticidas pode ser provocada por diversos factores, contudo esta contaminação pode ser minimizada se estes forem usados de forma racional e de um modo sustentável conforme o descrito na directiva 2009/128/CE de 21 de Outubro.
Resumo:
A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.
Resumo:
Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.