36 resultados para biomimetic sensors

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

New potentiometric membrane sensors with cylindrical configuration for tetracycline (TC) are described based on the use of a newly designed molecularly imprinted polymer (MIP) material consisting of 2-vinylpyridine as a functional monomer in a plasticized PVC membrane. The sensor exhibited significantly enhanced response towards TC over the concentration range 1.59 10 5–1.0 10 3 mol L 1 at pH 3–5 with a lower detection limit of 1.29 10 5 mol L 1. The response was near-Nernstian, with average slopes of 63.9 mV decade 1. The effect of lipophilic salts and various foreign common ions were tested and were found to be negligible. The possibility of applying the proposed sensor to TC determination in spiked biological fluid samples was demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent fromthe pHof test solutionswithin 2.0–5.5.Good selectivitywas observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0×10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0×10−4 to 1.0×10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A novel biomimetic sensor for the potentiometric transduction of oxytetracycline is presented. The artificial host was imprinted in methacrylic acid and/or acrylamide based polymers. Different amounts of molecularly imprinted and non-imprinted polymers were dispersed in different plasticizing solvents and entrapped in a poly(vinyl chloride) matrix. Only molecularly imprinted based sensors allowed a potentiometric transduction, suggesting the existence of host–guest interactions. These sensors exhibited a near-Nernstian response in steady state evaluations; slopes and detection limits ranged 42–63 mV/decade and 2.5–31.3 µg/mL, respectively. Sensors were independent from the pH of test solutions within 2–5. Good selectivity was observed towards glycine, ciprofloxacin, creatinine, acid nalidixic, sulfadiazine, cysteine, hydroxylamine and lactose. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (65 mV/decade), wide linear range (5.0×10−5 to 1.0×10−2 mol/L), low detection limit (19.8 µg/mL), and a stable baseline for a 5×10−3M citrate buffer (pH 2.5) carrier. The sensors were successfully applied to the analysis of drugs and urine. This work confirms the possibility of using molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mVΔlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL 1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (47 mV/Dlog([ENR]/ M), wide linear range (1.0×10-5–1.0×10-3 M), low detection limit (0.9 µg mL-1), and a stable baseline for a 5×10-2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mV/Δlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL−1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ± 0.7%), fast response, good sensitivity (47 mV/Δlog([ENR]/M), wide linear range (1.0 × 10−5–1.0 × 10−3 M), low detection limit (0.9 µg mL−1), and a stable baseline for a 5 × 10−2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μgmL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μgmL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μg mL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μg mL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new biomimetic sensor for leucomalachite green host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted in methacrylic acid or acrylamido-2-methyl-1-propanesulfonic acid-based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and trapped in poly(vinyl chloride). The potentiometric sensors exhibited a near-Nernstian response in steady state evaluations, with slopes and detection limits ranging from 45.8 to 81.2 mV and 0.28 to 1.01 , respectively. They were independent from the pH of test solutions within 3 to 5. Good selectivity was observed towards drugs that may contaminate water near fish cultures, such as oxycycline, doxycycline, enrofloxacin, trimethoprim, creatinine, chloramphenicol, and dopamine. The sensors were successfully applied to field monitoring of leucomalachite green in river samples. The method offered the advantages of simplicity, accuracy, applicability to colored and turbid samples, and automation feasibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1st ASPIC International Congress

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New PVC membrane electrodes for the determination of sulfadiazine (SDZ) are presented. The electrodes are fabricated with conventional and tubular configurations with a graphite-based electrical contact, and no internal reference solution. The selective membranes consist of bis(triphenylphosphoranilidene)ammonium·SDZ (electrode A), tetraoctylammonium bromide (electrode B), or iron(II)-phthalocyanine (FePC) (electrode C) electroactive materials dispersed in a PVC matrix of o-nitrophenyl octyl ether (o-NPOE) plasticizer. The sensors A, B, and C displayed linear responses over the concentration ranges 1.0*10-2 – 1.0*10–5, 1.0*10–2 – 7.5*10–6, and 3.2*10–2 – 7.0* 10–6 mol l–1 (detection limits of 1.09, 2.04 and 0.87 mg ml–1) with anionic slopes of –57.3 ± 0.1, –46.7 ± 0.5, and –65.1 ± 0.2 mV decade–1, respectively. No effect from pH was observed within 4.0 – 5.5, 4.8 – 10, and 4.5 – 8, respectively, and good selectivity was found. The sensors were applied to the analysis of pharmaceuticals and biological fluids in steady state and in flow conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deterioration of water quality by Cyanobacteria cause outbreaks and epidemics associated with harmful diseases in Humans and animals because of the toxins that they release. Microcystin-LR is one of the hepatotoxins most widely studied and the World Health Organization, recommend a maximum value of 1mgL 1 in drinking water. Highly specific recognition molecules, such as molecular imprinted polymers are developed to quantify microcystins in waters for human use and shown to be of great potential in the analysis of these kinds of samples. The obtained results were auspicious, the detection limit found, 1.5mgL 1, being of the same order of magnitude as the guideline limit recommended by the WHO. This technology is very promising because the sensors are stable and specific, and the technology is inexpensive and allows for rapid on-site monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4-vinyl pyridine (4-VP) or methacrylic acid (MAA) monomers in the presence of a cross-linker. CMQwas used as template. Similar nonimprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4-VP exhibited the best performance, presenting fast near-Nernstian response for CMQover the concentration range 6.2×10-6 – 1.0×10-2 mol L-1 with detection limits of 4.1×10-6 mol L-1. The sensor was independent from the pH of test solutions in the range 5 – 10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQin commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.