3 resultados para auscultation

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Acute respiratory infections are usual in children under three years old occurring in upper respiratory tract, having an impact on child and caregiver’s quality of life predisposing to otitis media or bronchiolitis. There are few valid and reliable measures to determine the child’s respiratory condition and to guide the physiotherapy intervention. Aim: To assess the intra and inter rater reliability of nasal auscultation, to analyze the relation between sounds’ classification and middle ear’s pressure and compliance as well as with the Clinical Severity Score. Methods: A cross-sectional observational study was composed by 125 nursery children aged up to three years old. Tympanometry, pulmonary and nasal auscultation and application of Clinical Severity Score were performed to each child. Nasal auscultation sounds’ were recorded and sent to 3 blinded experts, that classified, as “obstructed” and “unobstructed”, with a 48 hours interval, in order to analyze inter and intra rater reliability. Results: Nasal auscultation revealed a substantial inter and intra rater reliability (=0,749 and evaluator A - K= 0,691; evaluator B - K= 0,605 and evaluator C - K= 0,724, respectively). Both ears’ pressure was significantly lower in children with an "unobstructed" nasal sound when compared with an “obstructed” nasal sound (t=-3,599, p<0,001 in left ear; t=-2,258, p=0,026 in right ear). Compliance in both ears was significantly lower in children with an "obstructed" nasal sound when compared with “unobstructed” nasal sound (t=-2,728, p=0,007 in left ear; t=-3,830, p<0,001 in right ear). There was a statistically significant association between sounds’ classification and tympanograms types in both ear’s (=11,437, p=0,003 in left ear; =13,535, p=0,001 in right ear). There was a trend to children with an "unobstructed" nasal sound that had a lower clinical severity score when compared with “obstructed” children. Conclusion: It was observed a good intra and substantial inter reliability for nasal auscultation. Nasal auscultation sounds’ classification was related to middle ears’ pressure and compliance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Lower Respiratory Tract Infections (LRTIs) are highly prevalent in institutionalised people with dementia, constituting an important cause of morbidity and mortality. Computerised auscultation of Adventitious Lung Sounds (ALS) has shown to be objective and reliable to assess and monitor respiratory diseases, however its application in people with dementia is unknown. Aim: This study characterised ALS (crackles and wheezes) in institutionalised people with dementia. Methods: An exploratory descriptive study, including 6 long-term care institutions was conducted. The sample included a dementia group (DG) of 30 people with dementia and a match healthy group (HG) of 30 elderly people. Socio-demographic and anthropometric data, cognition, type and severity of dementia, cardio-respiratory parameters, balance, mobility and activities and participation were collected. Lung sounds were recorded with a digital stethoscope following Computerised Respiratory Sound Analysis (CORSA) guidelines. Crackles’ location, number (N), frequency (F), two-cycle duration (2CD), initial deflection width (IDW) and largest deflection width (LDW) and wheezes’ number (N), ratio (R) and frequency (F) were analysed per breathing phase. Statistical analyses were performed using PASW Statistics(v.19). Results: There were no significant differences between the two groups in relation to the mean N of crackles during inspiration and expiration in both trachea and thorax. DG trachea crackles had significant higher F during inspiration and lower IDW, 2CD and LDW during expiration when compared with HG. At the thorax, the LDW during inspiration was also significantly lower in the DG. A significant higher N of inspiratory wheezes was found in the HG. Both groups had a low ratio of high frequency wheezes. Conclusion: Computerised analyses of ALS informed on the respiratory system and function of people with dementia and elderly people. Hence, this could be the step towards prevention, early diagnosis and continuous monitoring of respiratory diseases in people with cognitive impairment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.