43 resultados para Source relative location

em Instituto Politécnico do Porto, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distributed generation unlike centralized electrical generation aims to generate electrical energy on small scale as near as possible to load centers, interchanging electric power with the network. This work presents a probabilistic methodology conceived to assist the electric system planning engineers in the selection of the distributed generation location, taking into account the hourly load changes or the daily load cycle. The hourly load centers, for each of the different hourly load scenarios, are calculated deterministically. These location points, properly weighted according to their load magnitude, are used to calculate the best fit probability distribution. This distribution is used to determine the maximum likelihood perimeter of the area where each source distributed generation point should preferably be located by the planning engineers. This takes into account, for example, the availability and the cost of the land lots, which are factors of special relevance in urban areas, as well as several obstacles important for the final selection of the candidates of the distributed generation points. The proposed methodology has been applied to a real case, assuming three different bivariate probability distributions: the Gaussian distribution, a bivariate version of Freund’s exponential distribution and the Weibull probability distribution. The methodology algorithm has been programmed in MATLAB. Results are presented and discussed for the application of the methodology to a realistic case and demonstrate the ability of the proposed methodology for efficiently handling the determination of the best location of the distributed generation and their corresponding distribution networks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eruca sativa (rocket salad) has been intensely consumed all over the world, insomuch as, this work was undertaken to evaluate the antioxidant status and the environmental contamination (positive and negative nutritional contribution) of leaves and stems from this vegetable. Antioxidant capacity of rocket salad was assessed by mean of optical methods, such as the total phenolic content (TPC), reducing power assay and DPPH radical scavenging activity. The extent of the environmental contamination was reached through the quantification of thirteen organochlorine pesticides (OCP) by using gas chromatography coupled with electron-capture detector (GC-ECD) and compound confirmations employing gas chromatography tandem mass-spectrometry (GC-MS/MS). The OCP residues were extracted by using Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) methodology.The extent of the environmental contamination was reached through the quantification of thirteen OCP by using gas chromatography coupled with electron-capture detector (GC-ECD) and compound confirmations employing GC-MS/MS. The OCP residues were extracted by using Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) methodology. This demonstrated that leaves presented more antioxidant activity than stems, emphasizing that leaves contained six times more polyphenolic compounds than stems. In what concerns the OCP occurrence, the average recoveries obtained at the three levels tested (40, 60 and 80 µg kg−1) ranged from 55% to 149% with a relative standard deviation of 11%, (except hexachrorobenzene). Three vegetables samples were collected from supermarkets and analysed following this study. According to data, only one sample achieved 16.21 of β-hexachlorocyclohexane, confirmed by GC-MS/MS. About OCP quantification, the data indicated that only one sample achieved 16.21 µg kg−1 of β-hexachlorocyclohexane, confirmed by GC-MS/MS, being the QuEChERS a good choice for the of OCPs extraction. Furthermore, the leaves consumption guaranty higher levels of antioxidants than stems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

É possível assistir nos dias de hoje, a um processo tecnológico evolutivo acentuado por toda a parte do globo. No caso das empresas, quer as pequenas, médias ou de grandes dimensões, estão cada vez mais dependentes dos sistemas informatizados para realizar os seus processos de negócio, e consequentemente à geração de informação referente aos negócios e onde, muitas das vezes, os dados não têm qualquer relacionamento entre si. A maioria dos sistemas convencionais informáticos não são projetados para gerir e armazenar informações estratégicas, impossibilitando assim que esta sirva de apoio como recurso estratégico. Portanto, as decisões são tomadas com base na experiência dos administradores, quando poderiam serem baseadas em factos históricos armazenados pelos diversos sistemas. Genericamente, as organizações possuem muitos dados, mas na maioria dos casos extraem pouca informação, o que é um problema em termos de mercados competitivos. Como as organizações procuram evoluir e superar a concorrência nas tomadas de decisão, surge neste contexto o termo Business Intelligence(BI). A GisGeo Information Systems é uma empresa que desenvolve software baseado em SIG (sistemas de informação geográfica) recorrendo a uma filosofia de ferramentas open-source. O seu principal produto baseia-se na localização geográfica dos vários tipos de viaturas, na recolha de dados, e consequentemente a sua análise (quilómetros percorridos, duração de uma viagem entre dois pontos definidos, consumo de combustível, etc.). Neste âmbito surge o tema deste projeto que tem objetivo de dar uma perspetiva diferente aos dados existentes, cruzando os conceitos BI com o sistema implementado na empresa de acordo com a sua filosofia. Neste projeto são abordados alguns dos conceitos mais importantes adjacentes a BI como, por exemplo, modelo dimensional, data Warehouse, o processo ETL e OLAP, seguindo a metodologia de Ralph Kimball. São também estudadas algumas das principais ferramentas open-source existentes no mercado, assim como quais as suas vantagens/desvantagens relativamente entre elas. Em conclusão, é então apresentada a solução desenvolvida de acordo com os critérios enumerados pela empresa como prova de conceito da aplicabilidade da área Business Intelligence ao ramo de Sistemas de informação Geográfica (SIG), recorrendo a uma ferramenta open-source que suporte visualização dos dados através de dashboards.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flow rates of drying and nebulizing gas, heat block and desolvation line temperatures and interface voltage are potential electrospray ionization parameters as they may enhance sensitivity of the mass spectrometer. The conditions that give higher sensitivity of 13 pharmaceuticals were explored. First, Plackett-Burman design was implemented to screen significant factors, and it was concluded that interface voltage and nebulizing gas flow were the only factors that influence the intensity signal for all pharmaceuticals. This fractionated factorial design was projected to set a full 2(2) factorial design with center points. The lack-of-fit test proved to be significant. Then, a central composite face-centered design was conducted. Finally, a stepwise multiple linear regression and subsequently an optimization problem solving were carried out. Two main drug clusters were found concerning the signal intensities of all runs of the augmented factorial design. p-Aminophenol, salicylic acid, and nimesulide constitute one cluster as a result of showing much higher sensitivity than the remaining drugs. The other cluster is more homogeneous with some sub-clusters comprising one pharmaceutical and its respective metabolite. It was observed that instrumental signal increased when both significant factors increased with maximum signal occurring when both codified factors are set at level +1. It was also found that, for most of the pharmaceuticals, interface voltage influences the intensity of the instrument more than the nebulizing gas flowrate. The only exceptions refer to nimesulide where the relative importance of the factors is reversed and still salicylic acid where both factors equally influence the instrumental signal. Graphical Abstract ᅟ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As espécies reativas de oxigénio (ROS) estão envolvidas no desenvolvimento de dor neuropática. No entanto, a aplicação clínica de moléculas antioxidantes no tratamento desta patologia tem demonstrado pouca eficácia. A inibição da NADPH oxidase (NOX), uma das principais fontes de ROS, poderá ser uma boa estratégia terapêutica. O nosso grupo verificou que a apocinina (inibidor da NOX) melhora parcialmente os sintomas de dor neuropática e a disfunção redox espinhal no modelo SNI (spared nerve injury). De forma a melhorar este efeito terapêutico, o presente estudo insere-se num projeto maior, que visa identificar as isoformas da NOX envolvidas na fisiopatologia da doença e avaliar o efeito da administração de inibidores específicos para essas isoformas. Assim, propusemo-nos a avaliar a disfunção redox espinhal em fases precoces dador neuropática periférica induzida pelo modelo SNI no Rato, relacionando-a com os comportamentos de dor demonstrados pelos animais. Foram constituídos três grupos experimentais: SNI, sham e naïve, com subgrupos testados e sacrificados aos dias 1, 3, 7 e 14 após a cirurgia. Avaliou-se a sensibilidade mecânica (vonFrey e pinprick) e ao frio (acetona) dos animais, sacrificaram-se e recolheram-se as medulas espinhais para análise imunohistoquímica, com marcadores de dano oxidativo no DNA e de dano nitrosativo. Ao contrário dos animais sham, que demonstraram um comportamento muito próximo dos naïve, os animais SNI desenvolveram alodínia mecânica e ao frio e hiperalgesia mecânica na pata ipsilateral. No entanto, o dano oxidativo no corno dorsal ipsilateral da medula espinhal apresentou-se idêntico nos grupos SNI e sham ao longo dos 14 dias de estudo, não havendo também diferenças entre os cornos ipsi e contralateral à lesão nervosa. É possível que o desenvolvimento de dor neuropática nos animais SNI não se faça acompanhar de disfunção redox espinhal, pelo menos até aos 14 dias pós indução. O facto de a lesão nervosa no modelo SNI se localizar numa porção distal do ciático, ao contrário de outros modelos em que o stresse oxidativo espinhal foi já descrito, poderia explicar essas diferenças. Em todo o caso, considerando que os resultados comportamentais obtidos indicam que as cirurgias SNI e sham causam diferentes níveis de sensibilização nos animais, parece-nos fulcral prolongar os tempos de neuropatia, e executar uma avaliação do estado redox com outros marcadores, de forma a elucidar se, de facto, existem ROS envolvidas nesta sensibilização e, em caso positivo, poder identificar essas espécies, bem como as suas fontes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best places to locate the Gas Supply Units (GSUs) on a natural gas systems and their optimal allocation to loads are the key factors to organize an efficient upstream gas infrastructure. The number of GSUs and their optimal location in a gas network is a decision problem that can be formulated as a linear programming problem. Our emphasis is on the formulation and use of a suitable location model, reflecting real-world operations and constraints of a natural gas system. This paper presents a heuristic model, based on lagrangean approach, developed for finding the optimal GSUs location on a natural gas network, minimizing expenses and maximizing throughput and security of supply.The location model is applied to the Iberian high pressure natural gas network, a system modelised with 65 demand nodes. These nodes are linked by physical and virtual pipelines – road trucks with gas in liquefied form. The location model result shows the best places to locate, with the optimal demand allocation and the most economical gas transport mode: by pipeline or by road truck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major determinant of the level of effective natural gas supply is the ease to feed customers, minimizing system total costs. The aim of this work is the study of the right number of Gas Supply Units – GSUs - and their optimal location in a gas network. This paper suggests a GSU location heuristic, based on Lagrangean relaxation techniques. The heuristic is tested on the Iberian natural gas network, a system modelized with 65 demand nodes, linked by physical and virtual pipelines. Lagrangean heuristic results along with the allocation of loads to gas sources are presented, using a 2015 forecast gas demand scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural gas industry has been confronted with big challenges: great growth in demand, investments on new GSUs – gas supply units, and efficient technical system management. The right number of GSUs, their best location on networks and the optimal allocation to loads is a decision problem that can be formulated as a combinatorial programming problem, with the objective of minimizing system expenses. Our emphasis is on the formulation, interpretation and development of a solution algorithm that will analyze the trade-off between infrastructure investment expenditure and operating system costs. The location model was applied to a 12 node natural gas network, and its effectiveness was tested in five different operating scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a computationally efficient methodology for the optimal location and sizing of static and switched shunt capacitors in large distribution systems. The problem is formulated as the maximization of the savings produced by the reduction in energy losses and the avoided costs due to investment deferral in the expansion of the network. The proposed method selects the nodes to be compensated, as well as the optimal capacitor ratings and their operational characteristics, i.e. fixed or switched. After an appropriate linearization, the optimization problem was formulated as a large-scale mixed-integer linear problem, suitable for being solved by means of a widespread commercial package. Results of the proposed optimizing method are compared with another recent methodology reported in the literature using two test cases: a 15-bus and a 33-bus distribution network. For the both cases tested, the proposed methodology delivers better solutions indicated by higher loss savings, which are achieved with lower amounts of capacitive compensation. The proposed method has also been applied for compensating to an actual large distribution network served by AES-Venezuela in the metropolitan area of Caracas. A convergence time of about 4 seconds after 22298 iterations demonstrates the ability of the proposed methodology for efficiently handling large-scale compensation problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To comply with natural gas demand growth patterns and Europe´s import dependency, the gas industry needs to organize an efficient upstream infrastructure. The best location of Gas Supply Units – GSUs and the alternative transportation mode – by phisical or virtual pipelines, are the key of a successful industry. In this work we study the optimal location of GSUs, as well as determining the most efficient allocation from gas loads to sources, selecting the best transportation mode, observing specific technical restrictions and minimizing system total costs. For the location of GSUs on system we use the P-median problem, for assigning gas demands nodes to source facilities we use the classical transportation problem. The developed model is an optimisation-based approach, based on a Lagrangean heuristic, using Lagrangean relaxation for P-median problems – Simple Lagrangean Heuristic. The solution of this heuristic can be improved by adding a local search procedure - the Lagrangean Reallocation Heuristic. These two heuristics, Simple Lagrangean and Lagrangean Reallocation, were tested on a realistic network - the primary Iberian natural gas network, organized with 65 nodes, connected by physical and virtual pipelines. Computational results are presented for both approaches, showing the location gas sources and allocation loads arrangement, system total costs and gas transportation mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of Dual Source Computed Tomography (Definition, Siemens Medical Solutions, Erlanger, Germany) allowed advances in temporal resolution, with the addition of a second X-ray source and an array of detectors to the TCM 64 slices. The ability to run exams on Dual Energy, allows greater differentiation of tissues, showing differences between closer attenuation coefficients. In terms of renal applications, the distinction of kidney stones and masses become one of the main advantages of the use of dual-energy technology. This article pretends to demonstrate operating principles of this equipment, as its main renal applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to locate an individual is an essential part of many applications, specially the mobile ones. Obtaining this location in an open environment is relatively simple through GPS (Global Positioning System), but indoors or even in dense environments this type of location system doesn't provide a good accuracy. There are already systems that try to suppress these limitations, but most of them need the existence of a structured environment to work. Since Inertial Navigation Systems (INS) try to suppress the need of a structured environment we propose an INS based on Micro Electrical Mechanical Systems (MEMS) that is capable of, in real time, compute the position of an individual everywhere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Espresso spent coffee grounds were chemically characterized to predict their potential, as a source of bioactive compounds, by comparison with the ones from the soluble coffee industry. Sampling included a total of 50 samples from 14 trademarks, collected in several coffee shops and prepared with distinct coffee machines. A high compositional variability was verified, particularly with regard to such water-soluble components as caffeine, total chlorogenic acids (CGA), and minerals, supported by strong positive correlations with total soluble solids retained. This is a direct consequence of the reduced extraction efficiency during espresso coffee preparation, leaving a significant pool of bioactivity retained in the extracted grounds. Besides the lipid (12.5%) and nitrogen (2.3%) contents, similar to those of industrial coffee residues, the CGA content (478.9 mg/100 g), for its antioxidant capacity, and its caffeine content (452.6 mg/100 g), due to its extensive use in the food and pharmaceutical industries, justify the selective assembly of this residue for subsequent use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Although relative uptake values aren’t the most important objective of a 99mTc-DMSA scan, they are important quantitative information. In most of the dynamic renal scintigraphies attenuation correction is essential if one wants to obtain a reliable result of the quantification process. Although in DMSA scans the absent of significant background and the lesser attenuation in pediatric patients, makes that this attenuation correction techniques are actually not applied. The geometric mean is the most common method, but that includes the acquisition of an anterior (extra) projection, which it is not acquired by a large number of NM departments. This method and the attenuation factors proposed by Tonnesen will be correlated with the absence of attenuation correction procedures. Material and Methods: Images from 20 individuals (aged 3 years +/- 2) were used and the two attenuation correction methods applied. The mean time of acquisition (time post DMSA administration) was 3.5 hours +/- 0.8h. Results: The absence of attenuation correction showed a good correlation with both attenuation methods (r=0.73 +/- 0.11) and the mean difference verified on the uptake values between the different methods were 4 +/- 3. The correlation was higher when the age was lower. The attenuation correction methods correlation was higher between them two than with the “no attenuation correction” method (r=0.82 +/- 0.8), and the mean differences of the uptake values were 2 +/- 2. Conclusion: The decision of not doing any kind of attenuation correction method can be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for an accurate value of the relative kidney uptake, then an attenuation correction method should be used. Attenuation correction factors proposed by Tonnesen can be easily implemented and so become a practical and easy to implement alternative, namely when the anterior projection - needed for the geometric mean methodology – is not acquired.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O desenvolvimento de sistemas de localização pedestre com recurso a técnicas de dead reckoning tem mostrado ser uma área em expansão no mundo académico e não só. Existem algumas soluções criadas, no entanto, nem todas as soluções serão facilmente implementadas no mercado, quer seja pelo hardware caro, ou pelo sistema em si, que é desenvolvido tendo em conta um cenário em particular. INPERLYS é um sistema que visa apresentar uma solução de localização pedestre, independentemente do cenário, utilizando recursos que poderão ser facilmente usados. Trata-se de um sistema que utiliza uma técnica de dead reckonig para dar a localização do utilizador. Em cenários outdoor, um receptor GPS fornece a posição do utilizador, fornecendo uma posição absoluta ao sistema. Quando não é possível utilizar o GPS, recorre-se a um sensor MEMS e a uma bússola para se obter posições relativas à última posição válida do GPS. Para interligar todos os sensores foi utilizado o protocolo de comunicações sem fios ZigBee™. A escolha recaiu neste protocolo devido a factores como os seus baixos consumos e o seu baixo custo. Assim o sistema torna-se de uso fácil e confortável para o utilizador, ao contrário de sistemas similares desenvolvidos, que utilizam cabos para interligarem os diferentes componentes do sistema. O sensor MEMS do tipo acelerómetro tem a função de ler a aceleração horizontal, ao nível do pé. Esta aceleração será usada por um algoritmo de reconhecimento do padrão das acelerações para se detectar os passos dados. Após a detecção do passo, a aceleração máxima registada nesse passo é fornecida ao coordenador, para se obter o deslocamento efectuado. Foram efectuados alguns testes para se perceber a eficiência do INPERLYS. Os testes decorreram num percurso plano, efectuados a uma velocidade normal e com passadas normais. Verificou-se que, neste momento, o desempenho do sistema poderá ser melhorado, quer seja a nível de gestão das comunicações, quer a nível do reconhecimento do padrão da aceleração horizontal, essencial para se detectar os passos. No entanto o sistema é capaz de fornecer a posição através do GPS, quando é possível a sua utilização, e é capaz de fornecer a orientação do movimento.