34 resultados para Solid Phase Extraction

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

QuEChERS original method was modified into a new version for pesticides determination in soils. The QuEChERS method is based on liquid–liquid portioning with ACN and was followed by cleanup step using dispersive SPE and disposable pipette tips. Gas chromatographic separation with MS detection was carried out for pesticides quantification. The method was validated using recovery experiments for 36 multiclass pesticides. Mean recoveries of pesticides at each of the four spiking levels between 10–300 µg/kg of soil ranged from 70–120% for 26 pesticides with RSD values less than 15%. The method achieved low limit of detection less than 7.6 µ g/kg. Matrix effects were observed for 13 pesticides. Matrix effects were compensated by using matrix-matched calibration. The method was applied successfully using d-SPE or DPX in the analysis of the pesticides in soils from organic farming and integrated pest management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we sought to assess the applicability of GC–MS/MS for the identification and quantification of 36 pesticides in strawberry from integrated pest management (IPM) and organic farming (OF). Citrate versions of QuEChERS (quick, easy, cheap, effective, rugged and safe) using dispersive solid-phase extraction (d-SPE) and disposable pipette extraction (DPX) for cleanup were compared for pesticide extraction. For cleanup, a combination of MgSO4, primary secondary amine and C18 was used for both the versions. Significant differences were observed in recovery results between the two sample preparation versions (DPX and d-SPE). Overall, 86% of the pesticides achieved recoveries (three spiking levels 10, 50 and 200 µg/kg) in the range of 70–120%, with <13% RSD. The matrix effects were also evaluated in both the versions and in strawberries from different crop types. Although not evidencing significant differences between the two methodologies were observed, however, the DPX cleanup proved to be a faster technique and easy to execute. The results indicate that QuEChERS with d-SPE and DPX and GC–MS/MS analysis achieved reliable quantification and identification of 36 pesticide residues in strawberries from OF and IPM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A SPME-GC-MS/MS method for the determination of eight organophosphorus pesticides (azinphos-methyl, chlorpyriphos, chlorpyriphos-methyl, diazinon, fenitrothion, fenthion, malathion, and methidathion) in still and fortified wine was developed. The extraction procedure is simple, solvent free, and without any sample pretreatment. Limits of detection (LOD) and quantitation (LOQ) values in the range 0.1–14.3 lg/L and 0.2–43.3 lg/L, respectively, were obtained. The LOQ values are below the maximum residue levels (MRLs) established by European Regulation for grapes, with the exception of methidathion. Coefficients of correlation (R2) higher than 0.99 were obtained for the majority of the pesticides, in all different wines analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work describes a solid-phase microextraction (SPME) gas chromatography_tandem mass spectrometry (MS/MS) method to quantify 24 pesticides in fortified white wine and fortified red wine. In this study “fortified wine” refers to a wine in which fermentation is arrested before completion by alcohol distillate addition, allowing sugar and alcoholic contents to be higher (around 80-100 g/L total sugars and 19-22% alcohol strength (v/v)). The analytical method showed good linearity, presenting correlation coefficients (R2) ≥ 0.989 for all compounds. Limits of detection (LOD) and quantitation (LOQ) in the ranges of 0.05-72.35 and 0.16-219.23 μg/L, respectively, were obtained. LOQs are below the maximum residue levels (MRL) set by European Regulation for grapes. The proposed method was applied to 17 commercial fortified wines. The analyzed pesticides were not detected in the wines tested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid-phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18-E), benzenesulfonic acid modified silica cation exchanger (SA), poly (styrene-divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18-E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries>70% with standard deviations (SD)<15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′-DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

De forma a proteger o ambiente e a saúde humana, é imperativo evitar, prevenir ou reduzir as concentrações prejudiciais de poluentes nocivos na água subterrânea. A necessidade da obtenção de níveis de protecção da água subterrânea, encontra-se estabelecida em normas de qualidade e devem ser desenvolvidas metodologias que permitam a avaliação do estado químico da água subterrânea. Este trabalho experimental centrou-se no desenvolvimento de uma metodologia analítica de detecção e quantificação por cromatografia gasosa com detector de captura de electrões dos pesticidas atrazina e respectivos metabolitos (desetilatrazina e deisopropilatrazina), simazina, terbutilazina e o metabolito desetiterbutilazina, folpete, dimetoato, diazinão, malatião, cloropirifos e o azinfos-metilo em águas de poços. O estudo progressivo baseou-se na colheita de água a 20 poços agrícolas na zona de Esposende, área considerada pelo Ministério da Agricultura do Desenvolvimento Rural e Pescas como sendo uma zona vulnerável. O método utilizado para a validação da técnica cromatográfica baseou-se na norma ISO 8466-1:1990. Os parâmetros de validação considerados foram: especificidade/selectividade, capacidade de identificação, limites de detecção e quantificação, relação sinal/ruído, linearidade e curva de calibração, precisão (repetibilidade, precisão intermédia e reprodutibilidade), eficiência de extracção e arrastamento. O método demonstrou ser capaz de identificar e quantificar os analitos, sem interferência de outros compostos. Obteve-se um valor para os parâmetros da precisão inferior a 10%, enquanto os mais baixos limites de detecção e de quantificação foram, respectivamente, 0,014 e 0,047 μg L-1. Na preparação de amostras optou-se pelo método de extracção em fase sólida, tendo sido testadas cinco diferentes tipos de colunas extractivas; Lichrolut® EN/RP-18; Strata SDB-L e C18-E; Chromabond HR-P e HR-X, sendo que as colunas Lichrolut® EN/RP- 18 apresentaram melhores resultados para a globalidade dos pesticidas. Da análise efectuada aos 20 poços agrícolas verificou-se que apenas 3 não apresentavam qualquer vestígio dos pesticidas monitorizados, sendo que as restantes apresentavam valores entre 0,05 e 53,2 μg L-1, valores superiores aos impostos pela legislação em vigor (Decreto-Lei n.º 208/2008 de 28 de Outubro para água subterrânea e Decreto-Lei nº306/2007 referente a água para consumo). Verificou-se que os proprietários dos poços agrícolas, dos quais se procedeu à amostragem de água para análise não têm a consciência da falta de qualidade dessa água, nem dos malefícios que possam advir do seu consumo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A depressão é uma das doenças de foro psiquiátrico que mais prevalece na nossa sociedade, subsistindo evidências epidemiológicas que indicam um aumento substancial da sua incidência nos últimos anos. Esta evidência é consubstanciada pelo aumento significativo do consumo de antidepressivos em Portugal. Este cenário pressupõe a necessidade de uma metodologia que permita analisar, com rigor e numa perspectiva de rotina, os antidepressivos que podem ser encontrados em amostras de sangue. No contexto do Serviço de Toxicologia Forense do Instituto Nacional de Medicina Legal, Delegação do Norte, torna-se necessário o desenvolvimento de uma metodologia analítica para a determinação simultânea de 15 antidepressivos em sangue total e a sua validação relativamente a vários parâmetros analíticos. Os antidepressivos considerados foram Amitriptilina, Citalopram, Clomipramina, N-Desmetilclomipramina, Dotiepina, Fluoxetina, Imipramina, Maprotilina, Mianserina, Mirtazapina, Nortriptilina, Paroxetina, Sertralina, Trimipramina e Venlafaxina. A técnica utilizada para este efeito foi o GC/MS/MS, aplicando um procedimento extractivo prévio apropriado, baseado em procedimentos convencionais de extracção em fase sólida. A escolha desta técnica teve por base a possibilidade de identificar inequivocamente os compostos presentes na amostra, independentemente da complexidade da matriz, e de originar metodologias com uma sensibilidade elevada e com limites de detecção muito baixos. Os parâmetros analíticos considerados para validação da metodologia estabelecida foram selectividade/especificidade e capacidade de identificação; limites de detecção e de quantificação; linearidade e gama de trabalho; eficiência de extracção; arrastamento; exactidão (precisão, veracidade e incerteza de medição) e robustez. Com excepção da exactidão, um parâmetro que carece ainda de estudos complementares, todos os parâmetros estudados foram validados de acordo com os requisitos internos do Serviço. De uma forma geral, os resultados obtidos com o método desenvolvido revelaram-se selectivos e apresentaram respostas analíticas tanto para concentrações de antidepressivos em níveis terapêuticos como para níveis letais destas drogas. Os procedimentos extractivos revelaram-se eficazes e não foram verificados fenómenos de arrastamento em concentrações mais elevadas. O método foi ainda considerado robusto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seven pyrethroids (bifenthrin, fenpropathrin, k-cyhalothrin, permethrin, a-cypermethrin, fenvalerate, and deltamethrin) were extracted from water using C18 solid-phase extraction disks, followed by gas chromatography with an electron capture detector (GC-ECD) analysis. The limits of detection in water samples ranged from 0.5 ng L-1 (fenpropathrin) to 110 ng L- 1 (permethrin), applying the calibration graph. The effects of different numbers of (re)utilizations of the same disks (up to four times with several concentrations) on the recoveries of the pyrethroids were considered. The recoveries were all between 70 and 120% after four utilizations of the same disk. There was no difference between these recoveries at a confidence level of 95%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies were undertaken to determine the adsorption behavior of α-cypermethrin [R)-α-cyano-3-phenoxybenzyl(1S)-cis- 3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate, and (S)-α-cyano-3-phenoxybenzyl (1R)-cis-3-(2,2-dichlorovinyl)-2,2- dimethylcyclopropanecarboxylate] in solutions on granules of cork and activated carbon (GAC). The adsorption studies were carried out using a batch equilibrium technique. A gas chromatograph with an electron capture detector (GC-ECD) was used to analyze α-cypermethrin after solid phase extraction with C18 disks. Physical properties including real density, pore volume, surface area and pore diameter of cork were evaluated by mercury porosimetry. Characterization of cork particles showed variations thereby indicating the highly heterogeneous structure of the material. The average surface area of cork particles was lower than that of GAC. Kinetics adsorption studies allowed the determination of the equilibrium time—24 hours for both cork (1–2 mm and 3–4 mm) and GAC. For the studied α-cypermethrin concentration range, GAC revealed to be a better sorbent. However, adsorption parameters for equilibrium concentrations, obtained through the Langmuir and Freundlich models, showed that granulated cork 1–2 mm have the maximum amount of adsorbed α-cypermethrin (qm) (303 μg/g); followed by GAC (186 μg/g) and cork 3-4 mm (136 μg/g). The standard deviation (SD) values, demonstrate that Freundlich model better describes the α-cypermethrin adsorption phenomena on GAC, while α-cypermethrin adsorption on cork (1-2 mm and 3-4 mm) is better described by the Langmuir. In view of the adsorption results obtained in this study it appears that granulated cork may be a better and a cheaper alternative to GAC for removing α-cypermethrin from water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, specific, and sensitive method based on theQuick Easy Cheap Effective Rugged and Safe (QuEChERS) method and a cleanup using dispersive solid-phase extraction with MgSO4, PSA, and C18 sorbents has been developed for the routine analysis of 14 pesticides in strawberries. The analyses were performed by three different analytical methodologies: gas chromatography (GC) with electron capture detection (ECD), mass spectrometry (MS), and tandem mass spectrometry (MS/MS). The recoveries for all the pesticides studied were from 46 to 128%, with relative standard deviation of <15% in the concentration range of 0.005-0.250 mg/kg. The limit of detection (LOD) for all compoundsmetmaximumresidue limits (MRL) accepted in Portugal for organochlorine pesticides (OCP). A survey study of strawberries produced in Portugal in the years 2009-2010 obtained from organic farming (OF) and integrated pest management (IPM) was developed. Lindane and β-endosulfan were detected above the MRL in OF and IPM. Other OCP (aldrin, o,p0-DDT and their metabolites, and methoxychlor) were found below the MRL. The OCP residues detected decreased from 2009 to 2010. The QuEChERS method was successfully applied to the analysis of strawberry samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to combat a variety of pests, pesticides are widely used in fruits. Several extraction procedures (liquid extraction, single drop microextraction, microwave-assisted extraction, pressurized liquid extraction, supercritical fluid extraction, solid-phase extraction, solid-phase microextraction, matrix solid-phase dispersion, and stir bar sorptive extraction) have been reported to determine pesticide residues in fruits and fruit juices. The significant change in recent years is the introduction of the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods in these matrices analysis. A combination of techniques reported the use of new extraction methods and chromatography to provide better quantitative recoveries at low levels. The use of mass spectrometric detectors in combination with liquid and gas chromatography has played a vital role to solve many problems related to food safety. The main attention in this review is on the achievements that have been possible because of the progress in extraction methods and the latest advances and novelties in mass spectrometry, and how these progresses have influenced the best control of food, allowing for an increase in the food safety and quality standards.