6 resultados para Plantar pressure measurement

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the ground reaction forces (GRF) and plantar pressures between unloaded and occasional loaded gait. The GRF and plantar pressures of 60 participants were recorded during unloaded gait and occasional loaded gait (wearing a backpack that raised their body mass index to 30); this load criterion was adopted because is considered potentially harmful in permanent loaded gait (obese people). The results indicate an overall increase (absolute values) of GRF and plantar pressures during occasional loaded gait (p < 0.05); also, higher normalized (by total weight) values in the medial midfoot and toes, and lower values in the lateral rearfoot region were observed. During loaded gait the magnitude of the vertical GRF (impact and thrust maximum) decreased and the shear forces increased more than did the proportion of the load (normalized values). These data suggest a different pattern of GRF and plantar pressure distribution during occasional loaded compared to unloaded gait.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: O Acidente Vascular Encefálico (AVE) consiste numa das primeiras causas de mortalidade e morbilidade em Portugal. Esta lesão do Sistema Nervoso Central (SNC) desencadeia alterações ao nível do controlo postural (CP), que interferem com a recuperação funcional dos indivíduos. Objetivo: Deste modo, torna-se premente descrever as alterações do CP do tronco através da análise dos alinhamentos dos segmentos corporais do tronco no grupo de indivíduos selecionados, face à aplicação de um programa de intervenção baseado nos princípios do Conceito de Bobath. Metodologia: Estudo de série de casos, em seis indivíduos com alterações neuromotoras decorrentes de AVE, os quais foram avaliados antes e após o plano de intervenção segundo a abordagem baseada nos princípios do Conceito de Bobath, através do registo observacional, da Classificação Internacional de Funcionalidade Incapacidade e Saúde (CIF), da utilização do Software de Avaliação Postural (SAPO) e da Plataforma de Pressões da Emed (PPE), modelo AT. Os dados recolhidos foram trabalhados em função do valor médio através do software Excel. Resultados: A análise do SAPO, na posição ortostática observam-se mudanças quer na vista posterior quer nas laterais, indicando uma maior simetria entre hemitroncos, e mudanças nos alinhamentos verticais indicando uma maior aproximação dos 180º. Na PPE observam-se os valores da área plantar, da pressão plantar média e do centro de pressão, tendem globalmente a uma maior semelhança e simetria. Quanto à CIF também se verificou uma diminuição da restrição na participação e limitação na atividade. Conclusão: A intervenção baseada no processo de raciocínio clínico aparenta introduzir os estímulos necessários à reorganização funcional do SNC lesado, produzindo melhorias ao nível dos alinhamentos dos segmentos corporais e desta forma melhorar a atividade muscular.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A Obesidade é considerada um grave problema de saúde pública, com consequências negativas para os indivíduos obesos, nomeadamente dificuldades no desempenho de atividades de vida diária, na locomoção e na prática de exercício físico, o que pode restringir a participação em atividades sociais e de lazer. Esta investigação consiste num estudo quantitativo descritivo e tem como objetivo principal descrever de que forma os indivíduos adultos obesos classificam a sua adaptação ocupacional, a partir dos conceitos de identidade e competência ocupacional. Com este estudo, pretende-se ainda verificar se os indivíduos obesos apresentam níveis de atividade física mais baixos e valores mais elevados de pressão plantar, em relação a indivíduos com peso normal. A amostra é constituída por dez indivíduos adultos, de ambos os sexos, com índice de massa corporal igual (IMC) ou superior a 30 Kg/m2, e os instrumentos de avaliação utilizados são o Questionário Ocupacional (adaptado por N. Riopel com assistência de G. Kielhofner e J. Hawkins Watts – 1986), o IPAQ – Versão Curta e o Sistema de Palmilhas Pedar. A partir dos resultados, pode-se verificar que os indivíduos obesos apresentam uma rotina diária em que a maioria das atividades realizadas está relacionada com a casa, o trabalho e o descanso e que a percentagem de atividades de lazer em que participam é reduzida. No entanto, parecem satisfeitos com o seu desempenho na maior parte das atividades, consideram que muitas delas são importantes para si e estão motivados para as realizar. Dos resultados obtidos, podemos sugerir que os indivíduos obesos apresentam boa adaptação ocupacional. Pode-se ainda dizer que os indivíduos obesos apresentam um baixo nível de intensidade de atividade física, não se observando diferenças significativas relativamente aos indivíduos com peso normativo e que os seus valores máximos de pressão plantar normalizados são inferiores quando comparados com a população de peso normal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Biomechanical gait parameters—ground reaction forces (GRFs) and plantar pressures—during load carriage of young adults were compared at a low gait cadence and a high gait cadence. Differences between load carriage and normal walking during both gait cadences were also assessed. A force plate and an in-shoe plantar pressure system were used to assess 60 adults while they were walking either normally (unloaded condition) or wearing a backpack (loaded condition) at low (70 steps per minute) and high gait cadences (120 steps per minute). GRF and plantar pressure peaks were scaled to body weight (or body weight plus backpack weight). With medium to high effect sizes we found greater anterior-posterior and vertical GRFs and greater plantar pressure peaks in the rearfoot, forefoot and hallux when the participants walked carrying a backpack at high gait cadences compared to walking at low gait cadences. Differences between loaded and unloaded conditions in both gait cadences were also observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Because walking is highly recommended for prevention and treatment of obesity and some of its biomechanical aspects are not clearly understood for overweight people, we compared the absolute and normalized ground reaction forces (GRF), plantar pressures, and temporal parameters of normal-weight and overweight participants during overground walking. Method: A force plate and an in-shoe pressure system were used to record GRF, plantar pressures (foot divided in 10 regions), and temporal parameters of 17 overweight adults and 17 gender-matched normal-weight adults while walking. Results: With high effect sizes, the overweight participants showed higher absolute medial-lateral and vertical GRF and pressure peaks in the central rearfoot, lateral midfoot, and lateral and central forefoot. However, analyzing normalized (scaled to body weight) data, the overweight participants showed lower vertical and anterior-posterior GRF and lower pressure peaks in the medial rearfoot and hallux, but the lateral forefoot peaks continued to be greater compared with normal-weight participants. Time of occurrence of medial-lateral GRF and pressure peaks in the midfoot occurred later in overweight individuals. Conclusions: The overweight participants adapted their gait pattern to minimize the consequences of the higher vertical and propulsive GRF in their musculoskeletal system. However, they were not able to improve their balance as indicated by medial-lateral GRF. The overweight participants showed higher absolute pressure peaks in 4 out of 10 foot regions. Furthermore, the normalized data suggest that the lateral forefoot in overweight adults was loaded more than the proportion of their extra weight, while the hallux and medial rearfoot were seemingly protected.