14 resultados para Membranmechanik, AFM, porenüberspannende Membranen, nano-BLM

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless Sensor Networks (WSN) are being used for a number of applications involving infrastructure monitoring, building energy monitoring and industrial sensing. The difficulty of programming individual sensor nodes and the associated overhead have encouraged researchers to design macro-programming systems which can help program the network as a whole or as a combination of subnets. Most of the current macro-programming schemes do not support multiple users seamlessly deploying diverse applications on the same shared sensor network. As WSNs are becoming more common, it is important to provide such support, since it enables higher-level optimizations such as code reuse, energy savings, and traffic reduction. In this paper, we propose a macro-programming framework called Nano-CF, which, in addition to supporting in-network programming, allows multiple applications written by different programmers to be executed simultaneously on a sensor networking infrastructure. This framework enables the use of a common sensing infrastructure for a number of applications without the users having to worrying about the applications already deployed on the network. The framework also supports timing constraints and resource reservations using the Nano-RK operating system. Nano- CF is efficient at improving WSN performance by (a) combining multiple user programs, (b) aggregating packets for data delivery, and (c) satisfying timing and energy specifications using Rate- Harmonized Scheduling. Using representative applications, we demonstrate that Nano-CF achieves 90% reduction in Source Lines-of-Code (SLoC) and 50% energy savings from aggregated data delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the Pseudo phase plane (PPP) method for detecting the existence of a nanofilm on the nitroazobenzene-modified glassy carbon electrode (NAB-GC) system. This modified electrode systems and nitroazobenze-nanofilm were prepared by the electrochemical reduction of diazonium salt of NAB at the glassy carbon electrodes (GCE) in nonaqueous media. The IR spectra of the bare glassy carbon electrodes (GCE), the NAB-GC electrode system and the organic NAB film were recorded. The IR data of the bare GC, NAB-GC and NAB film were categorized into five series consisting of FILM1, GC-NAB1, GC1; FILM2, GC-NAB2, GC2; FILM3, GC-NAB3, GC3 and FILM4, GC-NAB4, GC4 respectively. The PPP approach was applied to each group of the data of unmodified and modified electrode systems with nanofilm. The results provided by PPP method show the existence of the NAB film on the modified GC electrode.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZnO films doped with vanadium (ZnO:V) have been prepared by dc reactive magnetron sputtering technique at different substrate temperatures (RT–500 C). The effects of the substrate temperature on ZnO:V films properties have been studied. XRD measurements show that only ZnO polycrystalline structure has been obtained, no V2O5 or VO2 crystal phase can be observed. It has been found that the film prepared at low substrate temperature has a preferred orientation along the (002) direction. As the substrate temperature is increased, the (002) peak intensity decreases. When the substrate temperature reaches the 500 C, the film shows a random orientation. SEM measurements show a clear formation of the nano-grains in the sample surface when the substrate temperature is higher than 400 C. The optical properties of the films have been studied by measuring the specular transmittance. The refractive index has been calculated by fitting the transmittance spectra using OJL model combined with harmonic oscillator.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we show a set of growth conditions, for the two step process, with which the growth of CZTSe is successful and reproducible. The properties of the best CTZSe thin films grown by this method were examined by SEM/EDS, XRD, Raman scattering, AFM/EFM, transmittance and reflectance measurements, photoluminescence (PL) measurements and hot point probe. A broad emission band was observed in the photoluminescence spectrum of the CZTSe thin film. The band gap energy was estimated to be around 1.05 eV at room temperature, using the transmittance and reflectance data, and CZTSe samples show p-type conductivity with the hot point probe. The different characterization techniques show that we could grow single phase CZTSe thin films with our optimized process conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last decades TiAlN coatings deposited by PVD techniques have been extensively investigated but, nowadays, their potential development for tribological applications is relatively low. However, new coatings are emerging based on them, trying to improve wear behavior. TiAlSiN thin coatings are now investigated, analyzing if Si introduction increases the wear resistance of PVD films. Attending to the application, several wear test configurations has been recently used by some researchers. In this work, TiAlSiN thin coatings were produced by PVD Unbalanced Magnetron Sputtering technique and they were conveniently characterized using Scanning Electron Microscopy (SEM) provided with Energy Dispersive Spectroscopy (EDS), Atomic Force Microscopy (AFM), Electron Probe Micro-Analyzer (EPMA), Micro Hardness (MH) and Scratch Test Analysis. Properties as morphology, thickness, roughness, chemical composition and structure, hardness and film adhesion to the substrate were investigated. Concerning to wear characterization, two very different ways were chosen: micro-abrasion with ball-on-flat configuration and industrial non-standardized tests based on samples inserted in a feed channel of a selected plastic injection mould working with 30% (wt.) glass fiber reinforced polypropylene. TiAlSiN coatings with a small amount of about 5% (wt.) Si showed a similar wear behavior when compared with TiAlN reported performances, denoting that Si addition does not improve the wear performance of the TiAlN coatings in these wear test conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium Diboride (TiB2) presents high mechanical and physical properties. Some wear studies were also carried out in order to evaluate its tribological properties. One of the most popular wear tests for thin films is the ball-cratering configuration. This work was focused on the study of the tribological properties of TiB2 thin films using micro-abrasion tests and following the BS EN 1071-6: 2007 standard. Due to high hardness usually patented by these films, diamond was selected as abrasive on micro-abrasion tests. Micro-abrasion wear tests were performed under five different durations, using the same normal load, speed rotation and ball. Films were deposited by unbalanced magnetron sputtering Physical Vapour Deposition (PVD) technique using TiB2 targets. TiB2 films were characterized using different methods as Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), Electron Probe Micro-Analyser (EPMA), Ultra Micro Hardness and Scratch-test Analysis, allowing to confirm that TiB2 presents adequate mechanical and physical properties. Ratio between hardness (coating and abrasive particles), wear resistance and wear coefficient were studied, showing that TiB2 films shows excellent properties for tribological applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the injection moulding of polypropylene reinforced with hard glass fibres, die materials are commonly subjected to severe abrasive wear. In order to improve its wear resistance, an unbalanced magnetron sputtering PVD compositional monolayered coating has been produced. The film was composed by a nanostructured TiB2 monolayer. Microstructure characterization and thickness evaluation were conducted by scanning electron microscopy (SEM). Film topography and roughness were accessed by SEM and Atomic Force Microscopy (AFM). The phase analyse was investigated by X-ray diffraction (XRD), using Cu Kalpha radiation. Scratch tests were conducted in order to study the film adhesion to the substrate. Load-Displacement curves (nanoindentation analysis) allowed measuring the film hardness and Young's modulus. A ball-cratering tribometer was used to determine the micro-abrasion laboratorial wear resistance, under different tests conditions, using SiC particles in distilled water slurry. At the end of these tests, the worn surfaces were analyzed by SEM and Energy Dispersive X-ray Spectroscopy (EDS) in order to compare these results with some other coatings already tested in the same conditions. To test the practical wear resistance, 135000 injection cycles were done in a plastic injection industrial mould. Coated samples were put on the plastic feed canal, after a turbulent zone. In these tests, a 30% (wt) glass fibres reinforced polypropylene was used. Worn sample surfaces were analyzed by SEM after 45.000 and 90.000 cycles. Image analyses were made in order to evaluate the damage increases and to observe the wear mechanisms involved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abrasion by glass fibers during injection molding of fiber reinforced plastics raises new challenges to the wear performance of the molds. In the last few decades, a large number of PVD and CVD coatings have been developed with the aim of minimizing abrasion problems. In this work, two different coatings were tested in order to increase the wear resistance of the surface of a mold used for glass fiber reinforced plastics: TiAlSiN and CrN/CrCN/DLC. TiAlSiN was deposited as a graded monolayer coating while CrN/CrCN/DLC was a nanostructured coating consisting of three distinct layers. Both coatings were produced by PVD unbalanced magnetron sputtering and were characterized using scanning electron microscopy (SEM) provided with energy dispersive spectroscopy (EDS), atomic force microscopy (AFM), micro hardness (MH) and scratch test analysis. Coating morphology, thickness, roughness, chemical composition and structure, hardness and adhesion to the substrate were investigated. Wear resistance was characterized through industrial tests with coated samples and an uncoated reference sample inserted in a feed channel of a plastic injection mold working with 30 wt.% glass fiber reinforced polypropylene. Results after 45,000 injection cycles indicate that the wear resistance of the mold was increased by a factor of 25 and 58, by the TiAlSiN and CrN/CrCN/DLC coatings, respectively, over the uncoated mold steel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is based on a previous experimental work in which embedded cylindrical heaters were applied to a pultrusion machine die, and resultant energetic performance compared with that achieved with the former heating system based on planar resistances. The previous work allowed to conclude that the use of embedded resistances enhances significantly the energetic performance of pultrusion process, leading to 57% decrease of energy consumption. However, the aforementioned study was developed with basis on an existing pultrusion die, which only allowed a single relative position for the heaters. In the present work, new relative positions for the heaters were investigated in order to optimize heat distribution process and energy consumption. Finite Elements Analysis was applied as an efficient tool to identify the best relative position of the heaters into the die, taking into account the usual parameters involved in the process and the control system already tested in the previous study. The analysis was firstly developed with basis on eight cylindrical heaters located in four different location plans. In a second phase, in order to refine the results, a new approach was adopted using sixteen heaters with the same total power. Final results allow to conclude that the correct positioning of the heaters can contribute to about 10% of energy consumption reduction, decreasing the production costs and leading to a better eco-efficiency of pultrusion process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to design a synthetic construct that mimics the natural bone extracellular matrix through innovative approaches based on simultaneous type I collagen electrospinning and nanophased hydroxyapatite (nanoHA) electrospraying using non-denaturating conditions and non-toxic reagents. The morphological results, assessed using scanning electron microscopy and atomic force microscopy (AFM), showed a mesh of collagen nanofibers embedded with crystals of HA with fiber diameters within the nanometer range (30 nm), thus significantly lower than those reported in the literature, over 200 nm. The mechanical properties, assessed by nanoindentation using AFM, exhibited elastic moduli between 0.3 and 2 GPa. Fourier transformed infrared spectrometry confirmed the collagenous integrity as well as the presence of nanoHA in the composite. The network architecture allows cell access to both collagen nanofibers and HA crystals as in the natural bone environment. The inclusion of nanoHA agglomerates by electrospraying in type I collagen nanofibers improved the adhesion and metabolic activity of MC3T3-E1 osteoblasts. This new nanostructured collagen–nanoHA composite holds great potential for healing bone defects or as a functional membrane for guided bone tissue regeneration and in treating bone diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Salmonella é um microrganismo responsável por grande parte das doenças alimentares, podendo por em causa a saúde pública da área contaminada. Uma deteção rápida, eficiente e altamente sensível e extremamente importante, sendo um campo em franco desenvolvimento e alvo de variados e múltiplos estudos na comunidade cientifica atual. Foi desenvolvido um método potenciométrico para a deteção de Salmonellas, com elétrodos seletivos de iões, construídos em laboratório com pontas de micropipetas, fios de prata e sensores com composição otimizada. O elétrodo indicador escolhido foi um ESI seletivo a cadmio, para redução da probabilidade de interferências no método, devido a pouca abundancia do cadmio em amostras alimentares. Elétrodos seletivos a sódio, elétrodos de Ag/AgCl de simples e de dupla juncão foram também construídos e caracterizados para serem aplicados como elétrodos de referência. Adicionalmente otimizaram-se as condições operacionais para a analise potenciométrica, nomeadamente o elétrodo de referencia utilizado, condicionamento dos elétrodos, efeito do pH e volume da solução amostra. A capacidade de realizar leituras em volumes muito pequenos com limites de deteção na ordem dos micromolares por parte dos ESI de membrana polimérica, foi integrada num ensaio com um formato nao competitivo ELISA tipo sanduiche, utilizando um anticorpo primário ligado a nanopartículas de Fe@Au, permitindo a separação dos complexos anticorpo-antigénio formados dos restantes componentes em cada etapa do ensaio, pela simples aplicação de um campo magnético. O anticorpo secundário foi marcado com nanocristais de CdS, que são bastante estáveis e é fácil a transformação em Cd2+ livre, permitindo a leitura potenciométrica. Foram testadas várias concentrações de peroxido de hidrogénio e o efeito da luz para otimizar a dissolução de CdS. O método desenvolvido permitiu traçar curvas de calibração com soluções de Salmonellas incubadas em PBS (pH 4,4) em que o limite de deteção foi de 1100 CFU/mL e de 20 CFU/mL, utilizando volumes de amostra de 10 ƒÊL e 100 ƒÊL, respetivamente para o intervalo de linearidade de 10 a 108 CFU/mL. O método foi aplicado a uma amostra de leite bovino. A taxa de recuperação media obtida foi de 93,7% } 2,8 (media } desvio padrão), tendo em conta dois ensaios de recuperação efetuados (com duas replicas cada), utilizando um volume de amostra de 100 ƒÊL e concentrações de 100 e 1000 CFU/mL de Salmonella incubada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.