3 resultados para Laminated tapes
em Instituto Politécnico do Porto, Portugal
Resumo:
The influence of uncertainties of input parameters on output response of composite structures is investigated in this paper. In particular, the effects of deviations in mechanical properties, ply angles, ply thickness and on applied loads are studied. The uncertainty propagation and the importance measure of input parameters are analysed using three different approaches: a first-order local method, a Global Sensitivity Analysis (GSA) supported by a variance-based method and an extension of local variance to estimate the global variance over the domain of inputs. Sample results are shown for a shell composite laminated structure built with different composite systems including multi-materials. The importance measures of input parameters on structural response based on numerical results are established and discussed as a function of the anisotropy of composite materials. Needs for global variance methods are discussed by comparing the results obtained from different proposed methodologies. The objective of this paper is to contribute for the use of GSA techniques together with low expensive local importance measures.
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
O presente projeto foi realizado no âmbito da unidade curricular Dissertação/Estágio/Projeto, e desenvolve um estudo sobre as estruturas porticadas de sinalização vertical em Autoestradas, ao nível da estrutura metálica e das fundações, com o objetivo de analisar três casos diferentes com características distintas. Dois dos casos em estudo são modelos comuns que se encontram facilmente nas autoestradas. O terceiro tem uma configuração diferente, mais gravoso que o habitual. Com estes três casos obtém-se um estudo completo e abrangente deste tipo de estrutura porticada. Ao longo do projeto é seguida a norma EC3 (Eurocódigo 3 – Projeto de estruturas de aço). Dimensionaram-se as estruturas utilizando secções tubulares, mas é também realizado o dimensionamento de uma solução estrutural alternativa recorrendo a perfis laminados I ou H. As estruturas foram modeladas com recurso ao software de cálculo Autodesk Robot Structural Analysis Professional, obtendo-se os esforços e deformações nos vários pontos da estrutura, que permitem realizar o dimensionamento manual das secções dos perfis estruturais, chumbadouros, chapas de fundação e fundações propriamente ditas. Na parte final do projeto apresenta-se uma apreciação global do mesmo, conclusões gerais sobre os resultados obtidos e possíveis desenvolvimentos futuros.