28 resultados para Laboratory waste
em Instituto Politécnico do Porto, Portugal
Resumo:
Education towards sustainability in Chemical Engineering (CEng) gave birth to awaste management program (WMP) at Instituto Superior de Engenharia do Porto, in Portugal. It involves students, teachers, and laboratory technicians. It aims to enhance the conscientiousness of the decision-maker next generation for saving resources, managing wastes, and at same time to develop applied chemistry understanding. This program was implemented in 1999 and is responsible for management and fate of all inorganic wastewater providing from training experimental activities of the CEng degree. An immediate reduction of wastes at their source was first defined. Wastes were collected separately and were reused, recycled or chemically treated, and after analytically controlled as legally imposed. Solids formed after this program were recycled, purified or followed suitable elimination. Global results point out environmental, pedagogical, and social benefits. Active participants are aware, in agreement, and publicly committed to the WMP.
Resumo:
β-lactamases are hydrolytic enzymes that inactivate the β-lactam ring of antibiotics such as penicillins and cephalosporins. The major diversity of studies carried out until now have mainly focused on the characterization of β-lactamases recovered among clinical isolates of Gram-positive staphylococci and Gram-negative enterobacteria, amongst others. However, only some studies refer to the detection and development of β-lactamases carriers in healthy humans, sick animals, or even in strains isolated from environmental stocks such as food, water, or soils. Considering this, we proposed a 10-week laboratory programme for the Biochemistry and Molecular Biology laboratory for majors in the health, environmental, and agronomical sciences. During those weeks, students would be dealing with some basic techniques such as DNA extraction, bacterial transformation, polymerase chain reaction (PCR), gel electrophoresis, and the use of several bioinformatics tools. These laboratory exercises would be conducted as a mini research project in which all the classes would be connected with the previous ones. This curriculum was compared in an experiment involving two groups of students from two different majors. The new curriculum, with classes linked together as a mini research project, was taught to a major in Pharmacy and an old curriculum was taught to students from environmental health. The results showed that students who were enrolled in the new curriculum obtained better results in the final exam than the students who were enrolled in the former curriculum. Likewise, these students were found to be more enthusiastic during the laboratory classes than those from the former curriculum.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
O presente trabalho teve como principais objectivos, estudar e optimizar o processo de tratamento do efluente proveniente das máquinas da unidade Cold-press da linha de produção da Empresa Swedwood, caracterizar a solução límpida obtida no tratamento e estudar a sua integração no processo, e por fim caracterizar o resíduo de pasta de cola obtido no tratamento e estudar a possível valorização energética deste resíduo. Após caracterização inicial do efluente e de acordo com os resultados de um estudo prévio solicitado pela Empresa Swedwood a uma empresa externa, decidiu-se iniciar o estudo de tratabilidade do efluente pelo processo físico-químico a coagulação/floculação. No processo de coagulação/floculação estudou-se a aplicabilidade, através de ensaios Jar-test, dos diferentes agentes de coagulação/floculação: a soda cáustica, a cal, o cloreto férrico e o sulfato de alumínio. Os melhores resultados neste processo foram obtidos com a adição de uma dose de cal de 500 mg/Lefluente, seguida da adição de 400 mg/Lefluente de sulfato de alumínio. Contudo, após este tratamento o clarificado obtido não possuía as características necessárias para a sua reintrodução no processo fabril nem para a sua descarga em meio hídrico. Deste modo procedeu-se ao estudo de tratamentos complementares. Nesta segunda fases de estudo testaram-se os seguintes os tratamentos: a oxidação química por Reagente de Fenton, o tratamento biológico por SBR (sequencing batch reactor) e o leito percolador. Da análise dos resultados obtidos nos diferentes tratamentos conclui-se que o tratamento mais eficaz foi o tratamento biológico por SBR com adição de carvão activado. Prevê-se que no final do processo de tratamento o clarificado obtido possa ser descarregado em meio hídrico ou reintroduzido no processo. Como o estudo apenas foi desenvolvido à escala laboratorial, seria útil poder validar os resultados numa escala piloto antes da sua implementação industrial. A partir dos resultados do estudo experimental, procedeu-se ao dimensionamento de uma unidade de tratamento físico-químico e biológico à escala industrial para o tratamento de 20 m3 de efluente produzido na fábrica, numa semana. Dimensionou-se ainda a unidade (leito de secagem) para tratamento das lamas produzidas. Na unidade de tratamento físico-químico (coagulação/floculação) os decantadores estáticos devem possuir o volume útil de 4,8 m3. Sendo necessários semanalmente 36 L da suspensão de cal (Neutrolac 300) e 12,3 L da solução de sulfato de alumínio a 8,3%. Os tanques de armazenamento destes compostos devem possuir 43,2 litros e 96 litros, respectivamente. Nesta unidade estimou-se que são produzidos diariamente 1,4 m3 de lamas. Na unidade de tratamento biológico o reactor biológico deve possuir um volume útil de 6 m3. Para que este processo seja eficaz é necessário fornecer diariamente 2,1 kg de oxigénio. Estima-se que neste processo será necessário efectuar a purga de 325 litros de lamas semanalmente. No final da purga repõe-se o carvão activado, que poderá ser arrastado juntamente com as lamas, adicionando-se 100 mg de carvão por litro de licor misto. De acordo com o volume de lamas produzidos em ambos os tratamentos a área mínima necessária para o leito de secagem é de cerca de 27 m2. A análise económica efectuada mostra que a aquisição do equipamento tem o custo de 22.079,50 euros, o custo dos reagentes necessários neste processo para um ano de funcionamento tem um custo total de 508,50 euros e as necessidades energéticas de 2.008,45 euros.
Resumo:
Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.
Resumo:
Com o desenvolvimento económico das últimas décadas, a gestão de recursos energéticos é um desafio que a sociedade moderna enfrenta. Assim, actualmente há a necessidade da procura de novas fontes de energia, fontes de energia renováveis. Sendo o biodiesel uma fonte de energia renovável, a sua crescente produção irá trazer um aumento da produção de resíduos, como o glicerol e ácidos gordos. É pois importante reduzir/valorizar estes resíduos de forma a impedir a sua acumulação ao longo do tempo. A valorização destes resíduos é o objectivo principal deste trabalho. A primeira parte consistiu na esterificação de ácidos gordos livres com glicerol, na presença de um catalisador ácido, para a produção de monoglicerídeos. Foram utilizados diferentes tipos de matérias-primas: glicerol (76,3%) e resíduo de ácidos gordos (20,8%), fornecidos pela empresa SOCIPOLE SA, glicerol puro (92,2%) e ácido oleico puro (93,1%). Os catalisadores usados foram o cloreto de zinco comercial e o ácido p-tolueonossulfónico comercial. Não foram efectuadas análises específicas aos monoglicerídeos, o produto foi caracterizado pelo índice de acidez. Aparentemente, a maior conversão de ácidos gordos foi obtida no ensaio de esterificação de ácidos gordos com glicerol, ambos da SOCIPOLE SA. No entanto, este não serviu como termo de comparação com os outros devido à formação de uma fase sólida (polímero). Relativamente aos outros ensaios, com razão molar glicerol/ácidos gordos de 1:3, o melhor resultado foi obtido na reacção de glicerol da SOCIPOLE SA com ácido oleico puro, na presença do catalisador ácido p-toluenossulfónico, à temperatura de 106,3ºC e tempo de reacção de 4h30min, sendo a conversão final de ácido oleico 80,7%. Na segunda parte foi feito o estudo da esterificação de ácidos gordos livres com metanol, na presença de ácido sulfúrico, para a produção de biodiesel utilizando ácidos gordos fornecidos pela empresa SOCIPOLE SA, ácidos gordos derivados dos sabões de um resíduo de glicerol fornecido pelo Laboratório de Tecnologia Química, Professora Doutora Lídia Vasconcelos do ISEP e ácidos gordos derivados dos sabões do glicerol bruto, fornecido pela empresa SOCIPOLE SA. Os ensaios foram efectuados a 65ºC, com uma agitação de 120rpm e uma razão molar ácidos gordos/metanol de 1:3. Verificou-se que o índice de acidez do produto, depois de lavado e seco, diminuía com o tempo de reacção e na generalidade a percentagem de ésteres aumentava, observando-se que a partir das seis horas, a reacção se tornava muito lenta. O estudo da razão ácidos gordos/metanol, não permitiu tirar conclusões. O melhor resultado obtido correspondeu a um produto com 96,2% de ésteres metílicos e 8,54mgKOH/gamostra de índice de acidez, pelo que não pode ainda ser designado de biodiesel.
Oxidative Leaching of metals from electronic waste with solutions based on quaternary ammonium salts
Resumo:
The treatment of electric and electronic waste (WEEE) is a problem which receives ever more attention. An inadequate treatment results in harmful products ending up in the environment. This project intends to investigate the possibilities of an alternative route for recycling of metals from printed circuit boards (PCBs) obtained from rejected computers. The process is based on aqueous solutions composed of an etchant, either 0.2 M CuCl2.2H2O or 0.2 M FeCl3.6H2O, and a quaternary ammonium salt (quat) such as choline chloride or chlormequat. These solutions are reminiscent of deep eutectic solvents (DES) based on quats. DES are quite similar to ionic liquids (ILs) and are used as well as alternative solvents with a great diversity of physical properties, making them attractive for replacement of hazardous, volatile solvents (e.g. VOCs). A remarkable difference between genuine DES and ILs with the solutions used in this project is the addition of rather large quantities of water. It is shown the presence of water has a lot of advantages on the leaching of metals, while the properties typical for DES still remain. The oxidizing capacities of Cu(II) stem from the existence of a stable Cu(I) component in quat based DES and thus the leaching stems from the activity of the Cu(II)/Cu(I) redox couple. The advantage of Fe(III) in combination with DES is the fact that the Fe(III)/Fe(II) redox couple becomes reversible, which is not true in pure water. This opens perspectives for regeneration of the etching solution. In this project the leaching of copper was studied as a function of gradual increasing water content from 0 - 100w% with the same concentration of copper chloride or iron(III) chloride at room temperature and 80ºC. The solutions were also tested on real PCBs. At room temperature a maximum leaching effect for copper was obtained with 30w% choline chloride with 0.2 M CuCl2.2H2O. The leaching effect is still stronger at 80°C, b ut of course these solutions are more energy consuming. For aluminium, tin, zinc and lead, the leaching was faster at 80ºC. Iron and nickel dissolved easily at room temperature. The solutions were not able to dissolve gold, silver, rhodium and platinum.
Resumo:
The industrial manufacturing of metallic objects results in a high level of foundry waste sands that may contain toxic compounds such as formaldehyde. The formaldehyde content of foundry waste sands was evaluated by liquid chromatography. Samples were collected during various steps of the industrial processes. Results showed that the phenolic alkaline process generated waste sands with higher formaldehyde content than the furanic process; the highest value was 7.6×10-3% (w/w). In this work, formaldehyde content decreased with time in all of the samples studied, revealing that most formaldehyde was released to the occupational environment.
Resumo:
The treatment efficiency of laboratory wastewaters was evaluated and ecotoxicity tests with Chlorella vulgaris were performed on them to assess the safety of their environmental discharge. For chemical oxygen demand wastewaters, chromium (VI), mercury (II) and silver were efficiently removedby chemical treatments.Areduction of ecotoxicitywas achieved; nevertheless, an EC50 (effective concentration that causes a 50% inhibition in the algae growth) of 1.5% (v/v) indicated still high level of ecotoxicity. For chloride determination wastewaters, an efficient reduction of chromium and silver was achieved after treatment. Regarding the reduction of ecotoxicity observed, EC50 increased from 0.059% to 0.5%, only a 0.02% concentration in the aquatic environment would guarantee no effects. Wastewaters containing phenanthroline/iron (II) complex were treated by chemical oxidation. Treatmentwas satisfactory concerning chemical parameters, although an increase in ecotoxicitywas observed (EC50 reduced from 0.31% to 0.21%). The wastes from the kinetic study of persulphate and iodide reaction were treated with sodium bisulphite until colour was removed. Although they did not reveal significant ecotoxicity, only over 1% of the untreated waste produced observable effects over algae. Therefore, ecotoxicity tests could be considered a useful tool not only in laboratory effluents treatment, as shown, but also in hazardous wastewaters management.
Resumo:
In this work three natural waste materials containing chitin were used as adsorbents for textile dyestuffs, namely the Anodonta (Anodonta cygnea) shell, the Sepia (Sepia officinalis) and the Squid (Loligo vulgaris) pens. The selected dyestuffs were the Cibacron green T3G-E (CI reactive green 12), and the Solophenyl green BLE 155% (CI direct green 26), both from CIBA, commonly used in cellulosic fibres dyeing, the most used fibres in the textile industry. Batch equilibrium studies showed that the materials’ adsorption capacities increase after a simple and inexpensive chemical treatment, which increases their porosity and chitin relative content. Kinetic studies suggested the existence of a high internal resistance in both systems. Fixed bed column experiments performed showed an improvement in adsorbents’ behaviour after chemical treatment. However, in the column experiments, the biodegradation was the main mechanism of dyestuff removal, allowing the materials’ bioregeneration. The adsorption was strongly reduced by the pore clogging effect of the biomass. The deproteinised Squid pen (grain size 0.500–1.41 mm) is the adsorbent with highest adsorption capacity (0.27 and 0.037 g/g, respectively, for the reactive and direct dyestuffs, at 20ºC), followed by the demineralised Sepia pen and Anodonta shell, behaving like pure chitin in all experiments, but showing inferior performances than the granular activated carbon tested in the column experiments.
Resumo:
This study uses the process simulator ASPEN Plus and Life Cycle Assessment (LCA) to compare three process design alternatives for biodiesel production from waste vegetable oils that are: the conventional alkali-catalyzed process including a free fatty acids (FFAs) pre-treatment, the acid-catalyzed process, and the supercritical methanol process using propane as co-solvent. Results show that the supercritical methanol process using propane as co-solvent is the most environmentally favorable alternative. Its smaller steam consumption in comparison with the other process design alternatives leads to a lower contribution to the potential environmental impacts (PEI’s). The acid-catalyzed process generally shows the highest PEI’s, in particular due to the high energy requirements associated with methanol recovery operations.
Resumo:
In this study, the effect of incorporation of recycled glass fibre reinforced plastics (GFRP) waste materials, obtained by means of shredding and milling processes, on mechanical behaviour of polyester polymer mortars (PM) was assessed. For this purpose, different contents of GFRP recyclates, between 4% up to 12% in weight, were incorporated into polyester PM materials as sand aggregates and filler replacements. The effect of the addition of a silane coupling agent to resin binder was also evaluated. Applied waste material was proceeding from the shredding of the leftovers resultant from the cutting and assembly processes of GFRP pultrusion profiles. Currently, these leftovers as well as non-conform products and scrap resulting from pultrusion manufacturing process are landfilled, with additional costs to producers and suppliers. Hence, besides the evident environmental benefits, a viable and feasible solution for these wastes would also conduct to significant economic advantages. Design of experiments and data treatment were accomplish by means of full factorial design approach and analysis of variance ANOVA. Experimental results were promising toward the recyclability of GFRP waste materials as partial replacement of aggregates and reinforcement for PM materials, with significant improvements on mechanical properties of resultant mortars with regards to waste-free formulations.
Resumo:
In this paper the adequacy and the benefit of incorporating glass fibre reinforced polymer (GFRP) waste materials into polyester based mortars, as sand aggregates and filler replacements, are assessed. Different weight contents of mechanically recycled GFRP wastes with two particle size grades are included in the formulation of new materials. In all formulations, a polyester resin matrix was modified with a silane coupling agent in order to improve binder-aggregates interfaces. The added value of the recycling solution was assessed by means of both flexural and compressive strengths of GFRP admixed mortars with regard to those of the unmodified polymer mortars. Planning of experiments and data treatment were performed by means of full factorial design and through appropriate statistical tools based on analyses of variance (ANOVA). Results show that the partial replacement of sand aggregates by either type of GFRP recyclates improves the mechanical performance of resultant polymer mortars. In the case of trial formulations modified with the coarser waste mix, the best results are achieved with 8% waste weight content, while for fine waste based polymer mortars, 4% in weight of waste content leads to the higher increases on mechanical strengths. This study clearly identifies a promising waste management solution for GFRP waste materials by developing a cost-effective end-use application for the recyclates, thus contributing to a more sustainable fibre-reinforced polymer composites industry.
Resumo:
Waste oil recycling companies play a very important role in our society. Competition among companies is tough and process optimization is essential for survival. By equipping oil containers with a level monitoring system that periodically reports the level and alerts when it reaches the preset threshold, the oil recycling companies are able to streamline the oil collection process and, thus, reduce the operation costs while maintaining the quality of service. This paper describes the development of this level monitoring system by a team of four students from different engineering backgrounds and nationalities. The team conducted a study of the state of the art, draw marketing and sustainable development plans and, finally, designed and implemented a prototype that continuously measures the container content level and sends an alert message as soon as it reaches the preset capacity.
Resumo:
The great majority of the courses on science and technology areas where lab work is a fundamental part of the apprenticeship was not until recently available to be taught at distance. This reality is changing with the dissemination of remote laboratories. Supported by resources based on new information and communication technologies, it is now possible to remotely control a wide variety of real laboratories. However, most of them are designed specifically to this purpose, are inflexible and only on its functionality they resemble the real ones. In this paper, an alternative remote lab infrastructure devoted to the study of electronics is presented. Its main characteristics are, from a teacher's perspective, reusability and simplicity of use, and from a students' point of view, an exact replication of the real lab, enabling them to complement or finish at home the work started at class. The remote laboratory is integrated in the Learning Management System in use at the school, and therefore, may be combined with other web experiments and e-learning strategies, while safeguarding security access issues.