11 resultados para Image quality perception

em Instituto Politécnico do Porto, Portugal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Developmental Dysplasia of the Hip (DDH), also know as Congenital Dislocation of the Hip, is common in infants and children and may persist into adulthood. The radiographic interpretation is highly conditioned by appropriate patient positioning and image quality criteria. The main goal of this study is to demonstrate the value of radiographic evaluation of DDH. Through the retrospective analysis of 65 radiographs of the hips, only 2 (3.1%) female patients with 1-2 years of age presented radiographic findings of DDH. The inappropriate field size and the improper placement and size of the gonadal shields, were the most common errors observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Considering that ionizing radiation effects are cumulative and the gonads are particularly sensitive to these effects, and also the clinical importance of pelvic radiographs in children, the excess of radiation exposure to the gonads must be avoided. The purpose of this study is to demonstrate the relevance of the correct use of gonad protection shields and to evaluate their use on the hip radiographs performed in a reference clinical institution, through the retrospective analysis of pelvic radiographic images performed in children. According the image quality assessment, 20 (40%) patients were unprotected and gonads shields were incorrectly placed in 24 (80%) patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Refluxo Vesico – Ureteral (RVU) é uma patologia frequente na idade pediátrica. A detecção precoce de RVU é fundamental na orientação terapêutica, de modo a permitir um crescimento renal adequado e prevenir infecções urinárias recorrentes. A investigação radiológica de RVU baseia-se na ecografia e cistouretrografia miccional seriada (CUMS), sendo este último procedimento, o método de eleição, efectuado sob controlo fluoroscópico. Este trabalho tem como objectivo dar a conhecer o papel CUMS na avaliação de RVU e abordar os parâmetros técnicos de aquisição, posicionamento e critérios de qualidade de imagem.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Virtual Reality (VR) has grown to become state-of-theart technology in many business- and consumer oriented E-Commerce applications. One of the major design challenges of VR environments is the placement of the rendering process. The rendering process converts the abstract description of a scene as contained in an object database to an image. This process is usually done at the client side like in VRML [1] a technology that requires the client’s computational power for smooth rendering. The vision of VR is also strongly connected to the issue of Quality of Service (QoS) as the perceived realism is subject to an interactive frame rate ranging from 10 to 30 frames-per-second (fps), real-time feedback mechanisms and realistic image quality. These requirements overwhelm traditional home computers or even high sophisticated graphical workstations over their limits. Our work therefore introduces an approach for a distributed rendering architecture that gracefully balances the workload between the client and a clusterbased server. We believe that a distributed rendering approach as described in this paper has three major benefits: It reduces the clients workload, it decreases the network traffic and it allows to re-use already rendered scenes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste trabalho foi desenvolvido um estudo detalhado dos equipamentos de imagiologia médica, que recorrem ao uso de radiação-X, bem como da ressonância magnética. No seguimento deste estudo foram realizadas diversas atividades com equipamentos reais, desde instalações, reparações, manutenções, até ao seu desmantelamento. Este tipo de atividade permitiu ter uma melhor perceção do funcionamento de cada equipamento e o tipo de trabalho que é realizado por um engenheiro eletrotécnico na PHILIPS no sector healthcare. Durante estas atividades foi possível fazer um estudo da qualidade de imagem, em termos de fatores geométricos, em que foi estudada a distorção, a ampliação e a penumbra de uma imagem. Todos estes parâmetros foram alvos de estudo de forma a poder obter imagens com grande qualidade, mas sem que seja comprometida a saúde do doente, devido à elevada exposição de radiação que corpo humano pode absorver. Este estudo tem como intuito perceber como é que a variação de certos parâmetros irá alterar a qualidade da imagem. Desta forma pretende-se perceber como podem ser calibrados os equipamentos de diagnóstico por imagem, para que o técnico de diagnóstico e terapêutica apenas tenha de indicar qual a parte do corpo humano a radiografar, sendo que a máquina se coloca automaticamente nos parâmetros pré-definidos sem qualquer intervenção humana.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Computação gráfica um campo que tem vindo a crescer bastante nos últimos anos, desde áreas como cinematográficas, dos videojogos, da animação, o avanço tem sido tão grande que a semelhança com a realidade é cada vez maior. Praticamente hoje em dia todos os filmes têm efeitos gerados através de computação gráfica, até simples anúncios de televisão para não falar do realismo dos videojogos de hoje. Este estudo tem como objectivo mostrar duas alternativas no mundo da computação gráfica, como tal, vão ser usados dois programas, Blender e Unreal Engine. O cenário em questão será todo modelado de raiz e será o mesmo nos dois programas. Serão feitos vários renders ao cenário, em ambos os programas usando diferentes materiais, diferentes tipos de iluminação, em tempo real e não de forma a mostrar as várias alternativas possíveis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knowledge is central to the modern economy and society. Indeed, the knowledge society has transformed the concept of knowledge and is more and more aware of the need to overcome the lack of knowledge when has to make options or address its problems and dilemmas. One’s knowledge is less based on exact facts and more on hypotheses, perceptions or indications. Even when we use new computational artefacts and novel methodologies for problem solving, like the use of Group Decision Support Systems (GDSSs), the question of incomplete information is in most of the situations marginalized. On the other hand, common sense tells us that when a decision is made it is impossible to have a perception of all the information involved and the nature of its intrinsic quality. Therefore, something has to be made in terms of the information available and the process of its evaluation. It is under this framework that a Multi-valued Extended Logic Programming language will be used for knowledge representation and reasoning, leading to a model that embodies the Quality-of-Information (QoI) and its quantification, along the several stages of the decision-making process. In this way, it is possible to provide a measure of the value of the QoI that supports the decision itself. This model will be here presented in the context of a GDSS for VirtualECare, a system aimed at sustaining online healthcare services.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Image resizing is a normal feature incorporated into the Nuclear Medicine digital imaging. Upsampling is done by manufacturers to adequately fit more the acquired images on the display screen and it is applied when there is a need to increase - or decrease - the total number of pixels. This paper pretends to compare the “hqnx” and the “nxSaI” magnification algorithms with two interpolation algorithms – “nearest neighbor” and “bicubic interpolation” – in the image upsampling operations. Material and Methods: Three distinct Nuclear Medicine images were enlarged 2 and 4 times with the different digital image resizing algorithms (nearest neighbor, bicubic interpolation nxSaI and hqnx). To evaluate the pixel’s changes between the different output images, 3D whole image plot profiles and surface plots were used as an addition to the visual approach in the 4x upsampled images. Results: In the 2x enlarged images the visual differences were not so noteworthy. Although, it was clearly noticed that bicubic interpolation presented the best results. In the 4x enlarged images the differences were significant, with the bicubic interpolated images presenting the best results. Hqnx resized images presented better quality than 4xSaI and nearest neighbor interpolated images, however, its intense “halo effect” affects greatly the definition and boundaries of the image contents. Conclusion: The hqnx and the nxSaI algorithms were designed for images with clear edges and so its use in Nuclear Medicine images is obviously inadequate. Bicubic interpolation seems, from the algorithms studied, the most suitable and its each day wider applications seem to show it, being assumed as a multi-image type efficient algorithm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measuring the quality of a b-learning environment is critical to determine the success of a b-learning course. There are a lot of materials related to the quality process, namely different approaches and perspectives but none of them is specific of the product of a b-learning context. In this paper we identify the indicators that should be analyzed in order to determine the quality of a b-learning course, since its success reflect not only the student’s perception, but also what should be taken into account. B-Learning environments are relatively new and combine educational characteristics with technological elements that support the learning process and the training delivery. Our main objective is to know what a high quality b-learning environment is in students’’ perception and what are the main quality dimensions of these courses, in the perspective of the products and services offered. After a literature review concerning the quality process and in particular the b-learning quality field, a structure that provides the main elements that should be evaluated by students when we are measuring the quality and the success of b-learning product/services was created. The structure obtained was applied to a case study of the Polytechnic Institute of Oporto. Results presented will help institutions to deliver services with more quality and improve their long-term competitiveness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The process of visually exploring underwater environments is still a complex problem. Underwater vision systems require complementary means of sensor information to help overcome water disturbances. This work proposes the development of calibration methods for a structured light based system consisting on a camera and a laser with a line beam. Two different calibration procedures that require only two images from different viewpoints were developed and tested in dry and underwater environments. Results obtained show, an accurate calibration for the camera/projector pair with errors close to 1 mm even in the presence of a small stereos baseline.