24 resultados para Field Calibration

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a growing interest in research on performance measurement and management practices, which seems to reflect researchers’ response to calls for the need to increase the relevance of management accounting research. However, despite the development of the new public management literature, studies involving public sector organizations are relatively small compared to those involving business organizations and extremely limited when it comes to public primary health care organizations. Yet, the economic significance of public health care organizations in the economy of developed countries and the criticisms these organizations regularly face from the public suggests there is a need for research. This is particularly true in the case of research that may lead to improvement in performance measurement and management practices and ultimately to improvements in the way health care organizations use their limited resources in the provision of services to the communities. This study reports on a field study involving three public primary health care organisations. The evidence obtained from interviews and archival data suggests a performance management practices in these institutions lacked consistency and coherence, potentially leading to decreased performance. Hierarchical controls seemed to be very weak and accountability limited, leading to a lack of direction, low motivation and, in some circumstances to insufficient managerial abilities and skills. Also, the performance management systems revealed a number of weaknesses, which suggests that there are various opportunities for improvement in performance in the studied organisations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this paper is to promote qualitative methodology within the scientific community of management. The specific objective is oriented to propose an empirical research process based on case study method. This is to ensure rigor in the empirical research process, that future research may follow a similar procedure to that is proposed. Design/methodology/approach: Following a qualitative methodological approach, we propose a research process that develops according to four phases, each with several stages. This study analyses the preparatory and field work phases and their stages. Findings: The paper shows the influence that case studies have on qualitative empirical research process in management. Originality/value:. Case study method assumes an important role within qualitative research by allowing for the study and analysis of certain types of phenomena that occur inside organisations, and in respect of which quantitative studies cannot provide an answer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho insere-se no domínio da calibração energética dos equipamentos SPT, dando seguimento ao disposto na norma EN ISO 22476-3, de aplicação obrigatória em Portugal. Para tal foi utilizada uma vara instrumentada, cuja instrumentação consiste em strain-gauges e acelerómetros piezoeléctricos. Esta instrumentação encontra-se fixa a um trecho de vara com comprimento de 60 cm e para a aquisição dos dados foi utilizado o sistema SPT Analyzer® comercializado pela firma PDI. O sistema permite registar os dados provenientes da instrumentação: sinais de um par de strain-gauges, transformados em registos de força (F1 e F2) e sinais de um par de acelerómetros, convertidos em registos de velocidade (V1 e V2) ao longo do tempo. O equipamento permite a avaliação, em tempo real, da qualidade dos registos e da energia máxima transmitida à vara em cada golpe e o conhecimento do deslocamento vertical do trem de varas ocorrido em cada golpe do martelo. Por outro lado, baseando-se no tema acima referido, pretende-se ainda desenvolver esforços no sentido de melhorar o novo método interpretativo dos resultados dos ensaios SPT e sua aplicação ao dimensionamento de estacas, dado que a previsão da capacidade de carga de estacas constitui um dos desafios da engenharia de fundações por requerer a estimativa de propriedades do solo, alterações pela execução da fundação e conhecimento do mecanismo de interacção solo-estaca. Este novo procedimento baseia-se nos princípios da dinâmica, rompendo com as metodologias até aqui consagradas, de natureza essencialmente empírica. A nova forma de interpretar os ensaios SPT, consubstanciada nos princípios de conservação de energia na cravação do amostrador SPT, irá permitir converter analiticamente o valor Nspt numa força dinâmica de reacção à penetração. A decomposição desta força dinâmica permite efectuar análises comparativas entre as resistências unitárias mobilizadas no amostrador SPT (modelo) e as mobilizadas na estaca (protótipo).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O telemóvel tem-se transformado numa ferramenta essencial no nosso dia-a-dia, constantemente são lançadas novas tecnologias que potenciam o uso do telemóvel nas tarefas do nosso quotidiano. Atualmente a grande tendência passa por fazer o download de aplicações com o objetivo de obter mais e diferentes tipos de informação, existe o desejo de ler de forma simples e intuitiva o mundo que nos rodeia, como se cada elemento fosse um objeto sobre o qual conseguiremos obter informação através do telemóvel. A tecnologia Near Field Communication (NFC) ajuda a transformar este desejo ou necessidade numa realidade de simples alcance. Podemos anexar “identificadores” nos objetos e “ver” estes identificadores através do telemóvel recorrendo a aplicações que fazem a ponte com os sistemas que nos permitem obter mais informação, por exemplo, internet. O NFC especifica um padrão de comunicação de redes sem fios, que permite a transferência de dados entre dois dispositivos separados por uma distância máxima de 10cm. NFC foi desenhado para ser integrado em telemóveis, que podem comunicar com outros telemóveis equipados com NFC ou ler informação de cartões ou tags. A dissertação avalia as oportunidades que a tecnologia NFC oferece ao mundo das telecomunicações móveis, nomeadamente na realidade do operador Vodafone Portugal, principalmente numa relação Empresa - Cliente. Esta tecnologia reúne o interesse dos fabricantes dos telemóveis, dos operadores e de parceiros críticos que vão ajudar a potenciar o negócio, nomeadamente entidades bancárias e interbancárias. A tecnologia NFC permite utilizar o telemóvel como um cartão de crédito/debito, ticketing, ler informação de posters (Smart Poster) que despoletem navegação contextualizada para outras aplicações ou para a internet para obter mais informação ou concretizar compras, estes são alguns cenários identificados que mais valor o NFC consegue oferecer. A dissertação foca-se na avaliação técnica do NFC na área de Smart Posters e resulta na identificação num conjunto de novos cenários de utilização, que são especificados e complementados com o desenvolvimento de um protótipo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A glutathione-S-transferase (GST)based biosensor was developed to quantify the thiocarbamate herbicide molinate in environmental water.The biosensor construction was based on GST immobilization onto a glassy carbon electrode via aminosilane–glutaraldehyde covalent attachment. The principle supporting the use of this biosensor consists of the GST inhibition process promoted by molinate. Differential pulse voltammetry was used to obtain a calibration curve for molinate concentration, ranging from 0.19 to 7.9 mgL -1 and presenting a detection limit of 0.064 mgL- 1. The developed biosensor is stable,and reusable during 15 days.The GST-based biosensor was successfully applied to quantify molinate in rice paddy field floodwater samples. The results achieved with the developed biosensor were in accordance with those obtained by high performance liquid chromatography. The proposed device is suitable for screening environmental water analysis and, since no sample preparation is required, it can be used in situ and in real-time measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes the development of an analytical method for the determination of methiocarb and its degradation products (methiocarb sulfoxide and methiocarb sulfone) in banana samples, using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure followed by liquid chromatography coupled to photodiode array detector (LCPAD). Calibration curves were linear in the range of 0.5−10 mg L−1 for all compounds studied. The average recoveries, measured at 0.1 mg kg−1 wet weight, were 92.0 (RSD = 1.8%, n = 3), 84.0 (RSD = 3.9%, n = 3), and 95.2% (RSD = 1.9%, n = 3) for methiocarb sulfoxide, methiocarb sulfone, and methiocarb, respectively. Banana samples treated with methiocarb were collected from an experimental field. The developed method was applied to the analysis of 24 samples (peel and pulp) and to 5 banana pulp samples. Generally, the highest levels were found for methiocarb sulfoxide and methiocarb. Methiocarb sulfone levels were below the limit of quantification, except in one sample (not detected).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the European project R-Fieldbus (http://www.hurray.isep.ipp.pt/activities/rfieldbus/), an industrial manufacturing field trial was developed. This field trial was conceived as a demonstration test bed for the technologies developed during the project. Because the R-Fieldbus field trial included prototype hardware devices, the purpose of this equipment changed and since the conclusion of the project, several new technologies also emerged, therefore an update of the field trial was required. This document describes an update of the manufacturing field trial. The purpose of this update, the changes and improvements introduced are described in the document. Additionally, this document also provides a reliable source of documentation for the equipment, configuration and software components of the manufacturing field trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale and Objectives Computer-aided detection and diagnosis (CAD) systems have been developed in the past two decades to assist radiologists in the detection and diagnosis of lesions seen on breast imaging exams, thus providing a second opinion. Mammographic databases play an important role in the development of algorithms aiming at the detection and diagnosis of mammary lesions. However, available databases often do not take into consideration all the requirements needed for research and study purposes. This article aims to present and detail a new mammographic database. Materials and Methods Images were acquired at a breast center located in a university hospital (Centro Hospitalar de S. João [CHSJ], Breast Centre, Porto) with the permission of the Portuguese National Committee of Data Protection and Hospital's Ethics Committee. MammoNovation Siemens full-field digital mammography, with a solid-state detector of amorphous selenium was used. Results The new database—INbreast—has a total of 115 cases (410 images) from which 90 cases are from women with both breasts affected (four images per case) and 25 cases are from mastectomy patients (two images per case). Several types of lesions (masses, calcifications, asymmetries, and distortions) were included. Accurate contours made by specialists are also provided in XML format. Conclusion The strengths of the actually presented database—INbreast—relies on the fact that it was built with full-field digital mammograms (in opposition to digitized mammograms), it presents a wide variability of cases, and is made publicly available together with precise annotations. We believe that this database can be a reference for future works centered or related to breast cancer imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os métodos clínicos que são realizados com recurso a tecnologias de imagiologia têm registado um aumento de popularidade nas últimas duas décadas. Os procedimentos tradicionais usados em cirurgia têm sido substituídos por métodos minimamente invasivos de forma a conseguir diminuir os custos associados e aperfeiçoar factores relacionados com a produtividade. Procedimentos clínicos modernos como a broncoscopia e a cardiologia são caracterizados por se focarem na minimização de acções invasivas, com os arcos em ‘C’ a adoptarem um papel relevante nesta área. Apesar de o arco em ‘C’ ser uma tecnologia amplamente utilizada no auxílio da navegação em intervenções minimamente invasivas, este falha na qualidade da informação fornecida ao cirurgião. A informação obtida em duas dimensões não é suficiente para proporcionar uma compreensão total da localização tridimensional da região de interesse, revelando-se como uma tarefa essencial o estabelecimento de um método que permita a aquisição de informação tridimensional. O primeiro passo para alcançar este objectivo foi dado ao definir um método que permite a estimativa da posição e orientação de um objecto em relação ao arco em ‘C’. De forma a realizar os testes com o arco em ‘C’, a geometria deste teve que ser inicialmente definida e a calibração do sistema feita. O trabalho desenvolvido e apresentado nesta tese foca-se num método que provou ser suficientemente sustentável e eficiente para se estabelecer como um ponto de partida no caminho para alcançar o objectivo principal: o desenvolvimento de uma técnica que permita o aperfeiçoamento da qualidade da informação adquirida com o arco em ‘C’ durante uma intervenção clínica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m−3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m−3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Tecnologias de Protecção Ambiental

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No decorrer dos últimos anos tem-se verificado um acréscimo do número de sistemas de videovigilância presentes nos mais diversos ambientes, sendo que estes se encontram cada vez mais sofisticados. Os casinos são um exemplo bastante popular da utilização destes sistemas sofisticados, sendo que vários casinos, hoje em dia, utilizam câmeras para controlo automático das suas operações de jogo. No entanto, atualmente existem vários tipos de jogos em que o controlo automático ainda não se encontra disponível, sendo um destes, o jogo Banca Francesa. A presente dissertação tem como objetivo propor um conjunto de algoritmos idealizados para um sistema de controlo e gestão do jogo de casino Banca Francesa através do auxílio de componentes pertencentes à área da computação visual, tendo em conta os contributos mais relevantes e existentes na área, elaborados por investigadores e entidades relacionadas. No decorrer desta dissertação são apresentados quatro módulos distintos, os quais têm como objetivo auxiliar os casinos a prevenir o acontecimento de fraudes durante o decorrer das suas operações, assim como auxiliar na recolha automática de resultados de jogo. Os quatro módulos apresentados são os seguintes: Dice Sample Generator – Módulo proposto para criação de casos de teste em grande escala; Dice Sample Analyzer – Módulo proposto para a deteção de resultados de jogo; Dice Calibration – Módulo proposto para calibração automática do sistema; Motion Detection – Módulo proposto para a deteção de fraude no jogo. Por fim, para cada um dos módulos, é apresentado um conjunto de testes e análises de modo a verificar se é possível provar o conceito para cada uma das propostas apresentadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Salmonella é um microrganismo responsável por grande parte das doenças alimentares, podendo por em causa a saúde pública da área contaminada. Uma deteção rápida, eficiente e altamente sensível e extremamente importante, sendo um campo em franco desenvolvimento e alvo de variados e múltiplos estudos na comunidade cientifica atual. Foi desenvolvido um método potenciométrico para a deteção de Salmonellas, com elétrodos seletivos de iões, construídos em laboratório com pontas de micropipetas, fios de prata e sensores com composição otimizada. O elétrodo indicador escolhido foi um ESI seletivo a cadmio, para redução da probabilidade de interferências no método, devido a pouca abundancia do cadmio em amostras alimentares. Elétrodos seletivos a sódio, elétrodos de Ag/AgCl de simples e de dupla juncão foram também construídos e caracterizados para serem aplicados como elétrodos de referência. Adicionalmente otimizaram-se as condições operacionais para a analise potenciométrica, nomeadamente o elétrodo de referencia utilizado, condicionamento dos elétrodos, efeito do pH e volume da solução amostra. A capacidade de realizar leituras em volumes muito pequenos com limites de deteção na ordem dos micromolares por parte dos ESI de membrana polimérica, foi integrada num ensaio com um formato nao competitivo ELISA tipo sanduiche, utilizando um anticorpo primário ligado a nanopartículas de Fe@Au, permitindo a separação dos complexos anticorpo-antigénio formados dos restantes componentes em cada etapa do ensaio, pela simples aplicação de um campo magnético. O anticorpo secundário foi marcado com nanocristais de CdS, que são bastante estáveis e é fácil a transformação em Cd2+ livre, permitindo a leitura potenciométrica. Foram testadas várias concentrações de peroxido de hidrogénio e o efeito da luz para otimizar a dissolução de CdS. O método desenvolvido permitiu traçar curvas de calibração com soluções de Salmonellas incubadas em PBS (pH 4,4) em que o limite de deteção foi de 1100 CFU/mL e de 20 CFU/mL, utilizando volumes de amostra de 10 ƒÊL e 100 ƒÊL, respetivamente para o intervalo de linearidade de 10 a 108 CFU/mL. O método foi aplicado a uma amostra de leite bovino. A taxa de recuperação media obtida foi de 93,7% } 2,8 (media } desvio padrão), tendo em conta dois ensaios de recuperação efetuados (com duas replicas cada), utilizando um volume de amostra de 100 ƒÊL e concentrações de 100 e 1000 CFU/mL de Salmonella incubada.