6 resultados para Eyes
em Instituto Politécnico do Porto, Portugal
Resumo:
This Is England is social realist film portraying racism and poverty in 1980s Britain through the eyes of Shaun, a 12 year old boy, who has lost his father in the Falklands war and as to come to terms with his own identity, the difficult transition from childhood to adolescence and the need to fit in a determined group/tribe/gang. The following article aims at analysing relevant aspects depicted from the film emphasizing the so much debated reality of life during 80s. In This is England Shane Meadows manages to rediscover his own self geography, by revisiting his adolescent years. It is a biographical film about the importance of peer pressure and the results of an excess of nationalism, at the same time it typifies some issues related to the 80s youth culture.
Resumo:
Tendo por referência a diretiva 2006/95/CE, o trabalho desenvolvido no contexto da disciplina de Dissertação/Projeto/Estágio do Mestrado de Engenharia de Instrumentação e Metrologia, decorreu nas instalações do IEP (Instituto Electrotécnico Português) e teve como objetivo principal o desenvolvimento de um procedimento de avaliação dos efeitos fotobiológicos no olho e pele provocados por fontes de emissão contínua (LED), doravante designado método alternativo ao de referência. Os dois métodos, alternativo e de referência, utilizam respectivamente um foto-radiómetro multicanal e um espetro-radiómetro. O procedimento desenvolvido (método alternativo) de acordo com a norma EN/IEC62471) consiste na aquisição dos valores de irradiância com recurso a um foto-radiómetro e posterior determinação dos valores da radiância, com os quais se faz a avaliação dos efeitos fotobiológicos, para fontes de luz LED (Light Emitting Diode) ou GLS (General Lighting Service). A consulta detalhada da norma EN/IEC62471 e a pesquisa sobre os conceitos, definições, equipamentos e metodologias relacionadas com o tema em causa, constituiu o primeiro passo deste projecto. Com recurso aos dois equipamentos, uma fonte de luz LED (módulo de 12 lâmpadas LED) é avaliada em relação aos perigos (ou riscos) actínico UV e UV-A, ao perigo da luz azul e ainda o perigo térmico na retina e térmico na pele, permitindo fazer uma análise comparativa dos resultados. O método alternativo revelou-se bastante flexível e eficaz, proporcionando bons resultados em termos da irradiância e radiância dos referidos efeitos fotobiológicos. A comparação destes resultados com os valores limites de exposição mencionados na norma EN/IEC6247 permitiu afirmar que a fonte de luz LED avaliada não representa perigo fotobiológico para a saúde humana e classifica-se no grupo de risco “isento”. Uma vez cumpridos os objectivos, entendeu-se que seria uma mais-valia para o trabalho já realizado, estudar outro caso prático. Sendo assim, fez-se a avaliação da radiação de apenas um dos LED´s que constituíam a fonte usada nos ensaios anteriores, com o espetro-radiómetro (método de referência) e com uma distância de 200 mm entre a fonte e o medidor. Neste caso verificaram-se diferenças significativas nas quantidades obtidas quando comparadas com os valores normativos. Concluiu-se que o efeito fotobiológico da luz azul insere-se no grupo de “isento”, sem perigo para a saúde. Contudo, o efeito térmico da retina apresenta um aumento considerável da quantidade de radiância, embora dentro do grupo de risco “isento”. Esta classificação de grupos de risco. Face aos resultados obtidos, pode confirmar-se que as lâmpadas LED apresentam segurança fotobiológica, atendendo aos baixos valores de irradiância e radiância dos efeitos fotobiológicos estudados. Pode ainda afirmar-se que a utilização do foto-radiómetro em alternativa ao espetro-radiómetro se revela mais eficaz do ponto de vista de metodologia prática. Este trabalho demonstra a robustez desses dois equipamentos de avaliação dos efeitos fotobiológicos, e procura estabelecer uma linha de orientação para a prevenção dos efeitos adversos na pele e olhos de todos os seres humanos sujeitos à radiação ótica artificial. Quanto às incertezas de medições, em relação ao processo de medição com foto-radiómetro, a sua estimação não se realizou, devido a não rastreabilidade entre as medições indicadas pelo fabricante, no certificado de calibração e as medidas realizadas por outras entidades. Contudo, é propõe-se a sua realização em trabalhos futuros dentro desse âmbito. As incertezas dos resultados de medições com espetro-radiómetro foram parcialmente estimadas. Atendendo às potencialidades do sistema de medição, propõe-se como trabalho futuro, a aplicação da norma IEC62478, que faz parte da aplicação da norma EN/IEC62471 na avaliação do efeito da luz azul, com base na determinação da temperatura de cor correlacionada (CCT) de lâmpadas ou sistemas de lâmpadas incluindo luminárias. Os valores de irradiância e radiância adquiridos nos processos de avaliação, tanto com foto-radiómetro como espectro-radiómetro foram gravados em ficheiro Excel para um CD e anexados a este trabalho.
Resumo:
This study aimed to examine the differences in standing balance between individuals with Parkinson's disease (PD) and subjects without PD (control group), under single and dual-task conditions. A cross-sectional study was designed using a non-probabilistic sample of 110 individuals (50 participants with PD and 60 controls) aged 50 years old and over. The individuals with PD were in the early or middle stages of the disease (characterized by Hoehn and Yahr as stages 1-3). The standing balance was assessed by measuring the centre of pressure (CoP) displacement in single-task (eyes-open/eyes-closed) and dual-task (while performing two different verbal fluency tasks). No significant differences were found between the groups regarding sociodemographic variables. In general, the standing balance of the individuals with PD was worse than the controls, as the CoP displacement across tasks was significantly higher for the individuals with PD (p<0.01), both in anteroposterior and mediolateral directions. Moreover, there were significant differences in the CoP displacement based parameters between the conditions, mainly between the eyes-open condition and the remaining conditions. However, there was no significant interaction found between group and condition, which suggests that changes in the CoP displacement between tasks were not influenced by having PD. In conclusion, this study shows that, although individuals with PD had a worse overall standing balance than individuals without the disease, the impact of performing an additional task on the CoP displacement is similar for both groups.
Resumo:
The aim of this study was to analyze the efficacy of cognitive-motor dual-task training compared with single-task training on balance and executive functions in individuals with Parkinson's disease. Fifteen subjects, aged between 39 and 75 years old, were randomly assigned to the dual-task training group (n = 8) and single-task training group (n = 7). The training was run twice a week for 6 weeks. The single-task group received balance training and the dual-task group performed cognitive tasks simultaneously with the balance training. There were no significant differences between the two groups at baseline. After the intervention, the results for mediolateral sway with eyes closed were significantly better for the dual-task group and anteroposterior sway with eyes closed was significantly better for the single-task group. The results suggest superior outcomes for the dual-task training compared to the single-task training for static postural control, except in anteroposterior sway with eyes closed.
Resumo:
Recent changes in regulatory requirements and social views on animal testing have incremented the development of reliable alternative tests for predicting skin and ocular irritation potential of products based on new raw materials. In this regard, botanical ingredients used in cosmetic products are among those materials, and should be carefully reviewed concerning the potential presence of irritant constituents. In particular, cosmetic products used on the face, in vicinity of the eyes or that may come in contact with mucous membranes, should avoid botanical ingredients that contain, or are suspected to contain, such ingredients. In this study, we aimed to evaluate the effect of a new cosmetic ingredient, namely, coffee silverskin (CS), with an in vitro skin and ocular irritation assay using reconstructed human epidermis, EpiSkin™, and human corneal epithelial model, SkinEthics™ HCE, and an in vivo assay. Three different extracts of CS were evaluated. The histology of the models after extracts applications was analysed. The in vitro results demonstrated that extracts were not classified as irritant and the histological analyses proved that extracts did not affect both models structure. The content of caffeine, 5-hydroxymethyl furfural and chlorogenic acid was quantified after the epidermal assay. The in vivo test carried out with the most promising extract (hydroalcoholic) showed that, with respect to irritant effects, these extracts can be regarded as safe for topical application.
Resumo:
A Sociedade Europeia de Pesquisa do Sono realizou muito recentemente um estudo, onde mostrou que a prevalência média de adormecimento ao volante nos últimos 2 anos foi de 17%. Além disto, tem sido provado por todo o mundo que a sonolência durante a condução é uma das principais causas de acidentes de trânsito. Torna-se assim conveniente, o desenvolvimento de sistemas que analisem a suscetibilidade de um determinado condutor para adormecer no trânsito, bem como de ferramentas que monitorem em tempo real o estado físico e mental do condutor, para alertarem nos momentos críticos. Apesar do estudo do sono se ter iniciado há vários anos, a maioria das investigações focaram-se no ciclo normal do sono, estudando os indivíduos de forma relaxada e de olhos fechados. Só mais recentemente, têm surgido os estudos que se focam nas situações de sonolência em atividade, como _e o caso da condução. Uma grande parte Dos estudos da sonolência em condução têm utilizado a eletroencefalografia (EEG), de forma a perceber se existem alterações nas diferentes bandas de frequência desta, que possam indicar o estado de sonolência do condutor. Além disso, a evolução da sonolência a partir de alterações no piscar dos olhos (que podem ser vistas nos sinais EEG) também tem sido alvo de grande pesquisa, tendo vindo a revelar resultados bastante promissores. Neste contexto e em parceria com a empresa HealthyRoad, esta tese está integrada no projeto HealthyDrive, que visa o desenvolvimento de um sistema de alerta e deteção de sinais de fadiga e sonolência nos condutores de veículos automóveis. A contribuição desta tese no projeto prendeu-se com o estudo da sonolência dos indivíduos em condução a partir de sinais EEG, para desta forma investigar possíveis indicadores dos diferentes níveis desta que possam ser utilizados pela empresa no projeto. Foram recolhidos e analisados 17 sinais EEG de indivíduos em simulação de condução. Além disso foram desenvolvidos dois métodos de análise destes sinais: O primeiro para a deteção e análise dos piscar de olhos a partir de EEG, o segundo para análise do espetro de potência. Ambos os métodos foram utilizados para analisar os sinais recolhidos e investigar que tipo de relação existe entre a sonolência do condutor e as alterações nos piscares dos olhos, bem como as alterações do espetro do EEG. Os resultados mostraram uma correlação entre a duração do piscar de olhos e a sonolência do condutor. Com o aumento da sonolência velicou-se um aumento da duração do piscar, desencadeado principalmente pelo aumento na duração de fecho, que chegou aos 51.2%. Em relação ao espectro de potência, os resultados sugerem que a potência relativa de todas as bandas analisadas fornecem informações relevantes sobre a sonolência do condutor. Além disso, o parâmetro (_+_)/_ demostrou estar relacionado com variações da sonolência, diminuindo com o seu avanço e aumentando significativamente (111%) no instante em que os condutores adormeceram.