9 resultados para Elisabeth, Countess Palatine, 1618-1680
em Instituto Politécnico do Porto, Portugal
Resumo:
In the last ten years, teen noir movies and series — such as Donnie Darko (2001), Brick (2005), or Veronica Mars (2004-2007) — have become increasingly popular among audiences, both in the USA and in Europe, and aroused the curiosity of critics. These teen noir adventures present darker themes and technical features that distinguish them from numerous productions aiming at young adults. Their narrative and aesthetic characteristics reinvent and subvert the tradition of classic noir movies of the forties and fifties, thus generating a sense of novelty. In this article, I focus my attention on Veronica Mars, a famous teen noir series, created by Rob Thomas, to examine: a) the teen noir themes; b) the new profile and role of the private investigator; c) the empowerment of girls/young women; d) razor-sharp dialogues; e) intertextual references to old- school noir movies. In order to do so, resort to the research of specialists in the field of neo noir, such as Mark Conrad, Foster Hirsch, or Roz Kaveney. My main goal is to prove that a new (sub)genre is slowly emerging and revivifying teen cinema.
Resumo:
This paper reports a novel application of microwave-assisted extraction (MAE) of polyphenols from brewer’s spent grains (BSG). A 24 orthogonal composite design was used to obtain the optimal conditions of MAE. The influence of the MAE operational parameters (extraction time, temperature, solvent volume and stirring speed) on the extraction yield of ferulic acid was investigated through response surface methodology. The results showed that the optimal conditions were 15 min extraction time, 100 °C extraction temperature, 20 mL of solvent, and maximum stirring speed. Under these conditions, the yield of ferulic acid was 1.31±0.04% (w/w), which was fivefold higher than that obtained with conventional solid–liquid extraction techniques. The developed new extraction method considerably reduces extraction time, energy and solvent consumption, while generating fewer wastes. HPLC-DADMS analysis indicated that other hydroxycinnamic acids and several ferulic acid dehydrodimers, as well as one dehydrotrimer were also present, confirming that BSG is a valuable source of antioxidant compounds.
Resumo:
O rio Febros é um pequeno curso de água, situado no concelho de Vila Nova de Gaia, com cerca de 15 km de extensão, cuja bacia hidrográfica ocupa uma área de aproximadamente 35,4 km2. Nasce em Seixezelo e desagua na margem esquerda do Rio Douro no Cais do Esteiro, em Avintes. Em Maio de 2008, um acidente de viação teve como consequência o derrame de cerca de quatro toneladas de ácido clorídrico que rapidamente convergiu às águas do rio. Apenas um dia depois, o pH desceu para três e muitos foram os peixes que morreram. A solução adoptada para evitar o desaire foi introduzir milhares de litros de água de modo a diluir o ácido presente, ao longo de todo o curso de água. Tal facto não evitou a destruição de parte de um ecossistema, que ainda nos dias de hoje se encontra em recuperação. De forma a avaliar-se o impacto destas possíveis perturbações sejam estas de origem antropogénica ou natural é necessário possuir conhecimentos dos processos químicos tais como a advecção, a mistura devida à dispersão e a transferência de massa ar/água. Estes processos irão determinar o movimento e destino das substâncias que poderão ser descarregadas no rio. Para tal, recorrer-se-á ao estudo hidrogeométrico do curso de água assim como ao estudo do comportamento de um marcador, simulando uma possível descarga. A rodamina WT será o marcador a ser utilizado devido à panóplia de características ambientalmente favoráveis. Os estudos de campo com este corante, realizados em sequência de descarga previamente estudada, fornecem uma das melhores fontes de informação para verificação e validação de modelos hidráulicos utilizados em estudos de qualidade de águas e protecção ambiental. Escolheram-se dois pontos de descarga no Febros, um em Casal Drijo e outro no Parque Biológico de Gaia, possuindo cada um deles, a jusante, duas estações de monitorização. Pelo modelo ADE os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,3622; 0,5468; 1,6832 e 1,7504 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0633; 0,0684; 0,1548 e 0,1645 m/s. Quanto ao modelo TS, os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,2339; 0,1618; 0,5057e 1,1320 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0652; 0,0775; 0,1891 e 0,1676 m/s. Os resultados foram ajustados por um método directo, o método dos momentos, e por dois métodos indirectos, os modelos ADE e TS. O melhor ajuste corresponde ao modelo TS onde os valores do coeficiente de dispersão longitudinal e da velocidade de escoamento são aqueles que melhor se aproximam da realidade. Quanto ao método dos momentos, o valor estimado para a velocidade é de 0,162 m/s e para o coeficiente de dispersão longitudinal de 9,769 m2/s. Não obstante, a compreensão da hidrodinâmica do rio e das suas características, bem como a adequação de modelos matemáticos no tratamento de resultados formam uma estratégia de protecção ambiental inerente a futuros impactos que possam suceder.
Resumo:
On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 µL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min–1. Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10–6 to 5.0x10–5 mol L–1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h–1. The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.
Resumo:
A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.
Resumo:
The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.
Resumo:
Celiac disease (CD) is an autoimmune enteropathy, characterized by an inappropriate T-cell-mediated immune response to the ingestion of certain dietary cereal proteins in genetically susceptible individuals. This disorder presents environmental, genetic, and immunological components. CD presents a prevalence of up to 1% in populations of European ancestry, yet a high percentage of cases remain underdiagnosed. The diagnosis and treatment should be made early since untreated disease causes growth retardation and atypical symptoms, like infertility or neurological disorders. The diagnostic criteria for CD, which requires endoscopy with small bowel biopsy, have been changing over the last few decades, especially due to the advent of serological tests with higher sensitivity and specificity. The use of serological markers can be very useful to rule out clinical suspicious cases and also to help monitor the patients, after adherence to a gluten-free diet. Since the current treatment consists of a life-long glutenfree diet, which leads to significant clinical and histological improvement, the standardization of an assay to assess in an unequivocal way gluten in gluten-free foodstuff is of major importance.
Resumo:
This work evaluates the possibility of using spent coffee grounds (SCG) for biodiesel production and other applications. An experimental study was conducted with different solvents showing that lipid content up to 6 wt% can be obtained from SCG. Results also show that besides biodiesel production, SCG can be used as fertilizer as it is rich in nitrogen, and as solid fuel with higher heating value (HHV) equivalent to some agriculture and wood residues. The extracted lipids were characterized for their properties of acid value, density at 15 °C, viscosity at 40 °C, iodine number, and HHV, which are negatively influenced by water content and solvents used in lipid extraction. Results suggest that for lipids with high free fatty acids (FFA), the best procedure for conversion to biodiesel would be a two-step process of acid esterification followed by alkaline transesterification, instead of a sole step of direct transesterification with acid catalyst. Biodiesel was characterized for its properties of iodine number, acid value, and ester content. Although these quality parameters were not within the limits of NP EN 14214:2009 standard, SCG lipids can be used for biodiesel, blended with higher-quality vegetable oils before transesterification, or the biodiesel produced from SCG can be blended with higher-quality biodiesel or even with fossil diesel, in order to meet the standard requirements.
Resumo:
A voltammetric biosensor for Ara h 6 (a peanut allergen) detection in food samples was developed. Gold nanoparticle-modified screen-printed carbon electrodes were used to develop a sandwich-type immunoassay using two-monoclonal antibodies. The antibody-antigen interaction was detected through the electrochemical detection of enzymatically deposited silver. The immunosensor presented a linear range between 1 and 100 ng/ml, as well as high precision (inter-day RSD ≤9.8 %) and accuracy (recoveries ≥96.7 %). The detection and quantification limits were 0.27 and 0.88 ng/ml, respectively. It was possible to detect small levels of Ara h 6 in complex food matrices.