26 resultados para Compact cars
em Instituto Politécnico do Porto, Portugal
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
With the introduction of the electrics cars into the market new technologies regarding the battery are being developed and new problems to be solved, one of them the battery management system because each type of cell requires a specific way of handling. This research is done using the active research method to find out the actual problem on this subject and features a BMS should have, understand how they work and how to develop them applied to the purpose on this work. Once the features the BMS should have are clarified, it’s possible to develop a BMS for an electric racing car. The decisions are made taking into consideration the nature of the vehicle being developed. After the project done it’s clear to see that what was developed was not only the BMS itself but all the other factors around it, such as CAN communication, safety control, diagnostics and so on.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
Este trabalho surgiu no âmbito da Tese de Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química, aliando a necessidade da Empresa Monteiro Ribas – Indústrias, S.A. em resolver alguns problemas relacionados com as estufas da unidade J da fábrica de revestimentos. Outro dos objectivos era propor melhorias de eficiência energética neste sector da empresa. Para tal, foi necessário fazer um levantamento energético de toda a unidade, o que permitiu verificar que as estufas de secagem (Recobrimento 1 e 2) seriam o principal objecto de estudo. O levantamento energético da empresa permitiu conhecer o seu consumo anual de energia de 697,9 tep, o que a classifica, segundo o Decreto-lei nº 71 de 15 de Abril de 2008, como Consumidora Intensiva de Energia (CIE). Além disso, as situações que devem ser alvo de melhoria são: a rede de termofluido, que apresenta válvulas sem isolamento, o sistema de iluminação, que não é o mais eficiente e a rede de distribuição de ar comprimido, que não tem a estrutura mais adequada. Desta forma sugere-se que a rede de distribuição de termofluido passe a ter válvulas isoladas com lã de rocha, o investimento total é de 2.481,56 €, mas a poupança pode ser de 21.145,14 €/ano, com o período de retorno de 0,12 anos. No sistema de iluminação propõe-se a substituição dos balastros normais por electrónicos, o investimento total é de 13.873,74 €, mas a poupança é de 2.620,26 €/ano, com período de retorno de 5 anos. No processo de secagem das linhas de recobrimento mediram-se temperaturas de todos os seus componentes, velocidades de ar o que permitiu conhecer a distribuição do calor fornecido pelo termofluido. No Recobrimento 1, o ar recebe entre 39 a 51% do calor total, a tela recebe cerca de 25% e na terceira estufa este é apenas de 6%. Nesta linha as perdas de calor por radiação oscilam entre 6 e 11% enquanto as perdas por convecção representam cerca de 17 a 44%. Como o calor que a tela recebe é muito inferior ao calor recebido pelo ar no Recobrimento 1, propõe-se uma redução do caudal de ar que entra na estufa, o que conduzirá certamente à poupança de energia térmica. No Recobrimento 2 o calor fornecido ao ar representa cerca de 51 a 77% do calor total e o cedido à tela oscila entre 2 e 3%. As perdas de calor por convecção oscilam entre 12 e 26%, enquanto que as perdas por radiação têm valores entre 4 e 8%. No que diz respeito ao calor necessário para evaporar os solventes este oscila entre os 4 e 13%. Os balanços de massa e energia realizados ao processo de secagem permitiram ainda determinar o rendimento das 3 estufas do Recobrimento 1, com 36, 47 e 24% paras as estufa 1, 2 e 3, respectivamente. No Recobrimento 2 os valores de rendimento foram superiores, tendo-se obtido valores próximos dos 41, 81 e 88%, para as estufas 1, 2 e 3, respectivamente. Face aos resultados obtidos propõem-se a reengenharia do processo introduzindo permutadores compactos para aquecer o ar antes de este entrar nas estufas. O estudo desta alteração foi apenas realizado para a estufa 1 do Recobrimento 1, tendo-se obtido uma área de transferência de calor de 6,80 m2, um investimento associado de 8.867,81 €. e uma poupança de 708,88 €/ano, com um período de retorno do investimento de 13 anos. Outra sugestão consiste na recirculação de parte do ar de saída (5%), que conduz à poupança de 158,02 €/ano. Estes valores, pouco significativos, não estimulam a adopção das referidas sugestões.
Resumo:
A indústria automóvel é um dos setores mais exigentes do mercado global, por este motivo empresas como a Continental Mabor S.A, líderes de mercado, necessitam estar na linha da frente no que toca a programas de melhoria contínua e de uma gestão orientada para um crescimento rentável e sustentado. Nesta perspetiva, este estudo de dissertação tem como objetivo encontrar uma solução para a gestão de stock e FiFo (First in First out) de pneus em verde na supracitada empresa, situada em Lousado, Vila Nova de Famalicão. Este projeto de dissertação iniciou-se com uma análise e diagnóstico do processo produtivo do pneu, entre a Construção e a Vulcanização. Nesta análise, foi possível identificar vários problemas, sendo o mais crítico associado à logística interna de transporte do pneu “em curso”, de fabrico entre as fases do mesmo, Construção e Vulcanização. Devido a condicionantes estruturais e de organização, a logística interna de transporte entre estes dois sectores enfrenta estrangulamentos nos fluxos, a falta de espaço para acomodar o material em curso, problemas organizacionais de controlo e monitorização do processo produtivo, dificuldades de regulação do fluxo e localização dos carros de transporte dos pneus em verde. Face aos problemas detetados ao longo do estudo, foram analisadas várias soluções para a resolução ou minimização dos mesmos. Entre as soluções propostas salientam-se: o alargamento do sistema de transporte por tapetes rolantes GTC (Green Tire Conveying) a todos os módulos de construção. Esta solução diminui o fluxo de carros para a área da construção, descongestionando a zona próxima do sistema de carregamento automático GTAL (Green Tire Automatic Loading) na vulcanização. A implementação dum sistema Wi-Fi RFID, que permite identificar e localizar artigos em curso utilizando etiquetas inteligentes numa rede wireless, conseguindo melhorar a programação de produção e o respetivo sequenciamento. Sabendo também que a Continental se encontra numa fase de expansão, designada Projeto Route 17/20, as soluções propostas tomaram em consideração essa nova realidade futura. Assim, foram estudados e propostos novos layouts para esse atual processo. Nestes novos layouts, procurou-se uma reorganização dos processos de fabrico, bem como um redimensionamento dos espaços de parqueamento de carros de pneus verdes adequado aos volumes produtivos. De igual forma, adequou-se os espaços físicos à possível implementação de um sistema de FiFo de pneus em verde na planta fabril, quando concluída a expansão. Este trabalho de dissertação apresenta como vantagens diretas da sua implementação: gerar a menor perturbação no atual método de trabalho seguido na empresa; previsivelmente aumentar a eficiência do processo produtivo; potenciar o crescimento tecnológico programado pela empresa; e oferecer uma boa relação custo/benefício no investimento necessário. Como apreciação final, pode-se concluir que este estudo foi finalizado com sucesso, visto que as soluções propostas foram apreciadas positivamente pela Administração da Continental Mabor S.A. e estão correntemente a ser avaliadas pelo grupo.
Resumo:
O presente relatório descreve o trabalho de estágio efectuado na empresa Curtumes Aveneda, Lda com o objectivo de optimizar recursos como a água e energia. Foi realizado um diagnóstico energético que permitiu concluir que o consumo de energia na empresa é de 300 tep/ano, pelo que a empresa não é obrigada a adoptar as medidas de Regulamento de Gestão do Consumo de Energia (RGCE). O mesmo diagnóstico aponta para a existência de ineficiências, nomeadamente na tinturaria. Assim, foi projectado um sistema de controlo para adição de água na tinturaria com o intuito de reduzir o consumo de energia e água, e também melhorar a qualidade dos processos de tinturaria, dado que a adição de água é feita manualmente sem controlo de quantidade. Após consulta de fornecedor, o investimento em equipamento para tal sistema é de 10.012,00€ Foi desenvolvido um processo de recurtume compacto no sentido de promover a redução do consumo de água e de energia. Tal processo, quando comparado com um processo normal da empresa, gera uma redução de energia eléctrica no valor de 6.157,05 €/ano, uma redução no consumo de energia térmica da ordem de 904,00 €/ano, e ainda uma redução do consumo de água na ordem de 962 m3/ano correspondente a uma redução de 2.998,76 €/ano no tratamento de efluentes. Outras medidas foram sugeridas, mas sem uma fundamentação técnica e científica suficiente pelo que carecem de um estudo pormenorizado, como a instalação de arrancadores progressivos nos motores dos fulões, a optimização do aquecimento do ar de secagem na estufa com eventual recurso a painéis solares, e a optimização do funcionamento da caldeira dado o seu baixo rendimento.
Resumo:
The evaluation of benzene in different environments such as indoor (with and without tobacco smoke), a city area, countryside, gas stations and near exhaust pipes from cars running on different types of fuels was performed. The samples were analyzed using gas chromatography (GC) with flame ionization detection (FID) and tandem mass spectrometric detection (MS/MS) (to confirm the identification of benzene in the air samples). Operating conditions for the GC-MS analysis were optimized as well as the sampling and sample preparation. The results obtained in this work indicate that i) the type of fuel directly influences the benzene concentration in the air. Gasoline with additives provided the highest amount of benzene followed by unleaded gasoline and diesel; ii) the benzene concentration in the gas station was always higher than the advisable limit established by law (5 μg m−3) and during the unloading of gasoline the achieved concentration was 8371 μg m−3; iii) the data from the countryside (Taliscas) and the urban city (Matosinhos) were below 5 μg m−3 except 5 days after a fire on a petroleum refinery plant located near the city; iv) it was proven that in coffee shops where smoking is allowed the benzene concentration is higher (6 μg m−3) than in coffee shops where this is forbidden (4 μg m−3). This method may also be helpful for environmental analytical chemists who use GC-MS/MS for the confirmation or/and quantification of benzene.
Resumo:
In recent years several countries have set up policies that allow exchange of kidneys between two or more incompatible patient–donor pairs. These policies lead to what is commonly known as kidney exchange programs. The underlying optimization problems can be formulated as integer programming models. Previously proposed models for kidney exchange programs have exponential numbers of constraints or variables, which makes them fairly difficult to solve when the problem size is large. In this work we propose two compact formulations for the problem, explain how these formulations can be adapted to address some problem variants, and provide results on the dominance of some models over others. Finally we present a systematic comparison between our models and two previously proposed ones via thorough computational analysis. Results show that compact formulations have advantages over non-compact ones when the problem size is large.
Resumo:
O tratamento das águas residuais é uma matéria de extrema importância para o município da Póvoa de Varzim, não só por uma questão de saúde pública e conservação do meio ambiente como também pela vertente turística deste concelho, que tem na sua orla costeira seis praias às quais foram atribuídas bandeiras azuis pela sua qualidade. O concelho da Póvoa de Varzim engloba doze freguesias e possui quinze estações de tratamento de águas residuais (ETARs), sendo catorze delas compactas. O seu controlo é assegurado pela divisão de saneamento básico da câmara municipal da Póvoa de Varzim. O objetivo deste trabalho foi o diagnóstico de funcionamento das ETARs do município tendo em vista a identificação dos problemas existentes e a sua resolução/otimização. De forma a poder identificar o princípio de funcionamento e a presença de anomalias nas estações de tratamento, foram realizadas várias visitas a cada uma delas ao longo do período de estágio. A recolha de amostras para análises dos diferentes parâmetros foi feita por um funcionário e estas foram enviadas para o laboratório com parceria com a Câmara Municipal. Após uma extensa recolha de informação no local e de um estudo exaustivo de toda a documentação associada a cada ETAR concluiu-se que apenas quatro delas apresentavam problemas revelantes. As ETARs do parque industrial de Laúndos e do centro histórico de Rates apresentam caudais de admissão bastante elevados devido à descarga pontual de camiões cisterna o que faz com que o tratamento não seja eficaz. Como solução sugeriu-se a construção de um tanque de equalização em ambas as ETARs, com agitador e regulador de caudal, de forma a garantir, respetivamente, a mistura e uniformização das águas residuais domésticas e industriais e que apenas será bombeado o caudal adequado para tratamento. As ETARs da Incondave e das Fontaínhas apresentam sobretudo anomalias a nível do equipamento, o que leva a um mau desempenho da instalação. Aconselhou-se o conserto dos equipamentos danificados e uma inspeção mais frequente das instalações para que mal ocorra uma avaria, esta seja reparada o mais depressa possível. O estágio na câmara municipal da Póvoa de Varzim (CMPV) teve a duração de 10 meses, entre Outubro e Julho de 2012 e foi realizado no âmbito da disciplina de dissertação/ estágio do mestrado de tecnologias de proteção ambiental no Instituto Superior de Engenharia do Porto. Este estágio foi uma mais-valia para mim na medida em que pude consolidar os conhecimentos adquiridos ao longo de todo o meu percurso académico e conhecer a realidade do mercado de trabalho.
Resumo:
Dissertação apresentada ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Logística Orientada por: Professora Doutora Patrícia Alexandra Gregório Ramos
Resumo:
The intent of this dissertation is to review relevant existing management systems and chemical industry initiatives to identify synergies, overlaps and gaps with Sustainability best practices, to map the barriers to the incorporation of Sustainability and formulate recommendations to facilitate execution of Sustainability practices within existing management systems. A chemical industry Sustainability survey was conducted through APEQ, the Portuguese association of chemical companies, which constitutes the first baseline on the topic for this national industry association. The commonly used international standards and the Responsible Care® (RC) initiative were cross-referenced against the United Nations Global Compact Assessment Tool. Guidance on how to incorporate Sustainability into a company‘s modus operandi was collapsed into Sustainability Playbooks. The survey revealed that 73% of the APEQ member companies that participated in the survey have a Sustainability Plan. Both large and small/medium APEQ member companies see the market not willing to pay extra for ‗greener‘ products as one of the main barriers. APEQ large enterprise see complexity of implementation and low return on investment as the other most significant barriers while small/medium enterprise respond that the difficulty to predict customer sustainability needs is the other most significant barrier. Amongst many other insights from this survey reported to APEQ, Life Cycle Assessment practices were found to have a low level of implementation and were also considered of low importance, thus identifying a very important opportunity in Sustainability practices to be addressed by APEQ. Two hundred and seventy three assessment points from United Nations Global Compact Assessment Tool plus five additional items were cross-referenced with international standard requirements. With the authorization of the intellectual property owners, the United Nations Global Compact Assessment Tool was modified to introduce actionable recommendations for each gap identified by management standard. This tool was automated to output specific recommendations for 63 possible combinations after simply selecting from a list of commonly used management standards and the RC initiative. Finally this modified tool was introduced into Playbooks for Incorporation of Sustainability at two levels: a ―Get Started Playbook‖ for beginners or small/medium size enterprise and an ―Advanced Playbook‖ as a second advancement stage or for large enterprise.
Resumo:
The paper presents a study on business micro-location behaviour as well as corresponding factors of influence, conducted in two metropolitan areas, Bucharest-Ilfov (Romania) and Greater Porto (Portugal). By business micro-location we refer to a specific site such as a building or facility, accommodating a business within a small, compact geographical area (e.g. metropolitan area). At this geographical scale, the macroeconomic layer factors were excluded, applicable when discern between regions or countries. The factors derived from location theory and previous empirical studies were surveyed, completing a cross-sectional analysis in order to find out the specific weights of the location factors and preferences, by region and by industry. Based on already established firms’ feedback on location, the specific weights were granted by each industry to the main location factors, types of areas, and types of accommodation facilities. The authors also suggested a model to integrate these results into a Geographical Information System (GIS).
Resumo:
Portugal é um país dependente da energia do exterior, devido à elevada percentagem de consumo de energia a partir de fontes primárias, como por exemplo o gasóleo. Para colmatar este cenário, têm vindo a criar-se incentivos para o uso de energias renováveis e para intensificação de medidas de eficiência energética, como os sistemas de cogeração, de forma a tornar os processos industriais nacionais mais autónomos e mais competitivos. O presente trabalho, centra-se na determinação do potencial térmico disponível na central de trigeração da empresa Monteiro, Ribas-Indústria, SA, com a finalidade de identificar a quantidade de energia não utilizada, com vista ao aproveitamento dessa mesma energia nos processos mais problemáticos da empresa. Verificou-se que a água líquida era a fonte de maior energia não aproveitada, representando cerca de 30%, relativamente à energia disponível na água de refrigeração que é de 1890 kW. Assim, perante este facto, fez-se um estudo em dois setores autónomos da empresa, o setor dos revestimentos e o setor dos componentes técnicos da borracha. Pretendeu-se propor medidas para melhorar os seus processos produtivos, aproveitando essa energia. Para o efeito foi projetado um permutador de calor de placas com necessidade energética de 131,4 MWh, no setor dos revestimentos e um permutador compacto no setor de produção de placas de borracha, necessitando de uma energia de 335,2 MWh. Face à energia disponível na central de trigeração, de 161,9 MWh, verifica-se que esta apenas poderá ser aproveitada no setor dos revestimentos. Para tornar este objetivo real, a empresa Monteiro, Ribas- Indústria, SA necessitaria de efetuar um investimento no total de 49.390€. Além disso, foi contabilizado o rendimento das caldeiras da central térmica e da cogeração, ambas pelo método direto, apresentando estas os valores de 72% e 42%, respectivamente.
Resumo:
Mestrado em Engenharia Mecânica - Especialização em Gestão Industrial
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.