25 resultados para Commercial waters

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ascorbic acid is found in many food samples. Its clinical and technological importance demands an easyto- use, rapid, robust and inexpensive method of analysis. For this purpose, this work proposes a new flow procedure based on the oxidation of ascorbic acid by periodate. A new potentiometric periodate sensor was constructed to monitor this reaction. The selective membranes were of PVC with porphyrin-based sensing systems and a lipophilic cation as additive. The sensor displayed a near-Nernstian response for periodate over 1.0x10-2–6.0x10-6 M, with an anionic slope of 73.9 ± 0.9 mV decade-1. It was pH independent in acidic media and presented good selectivity features towards several inorganic anions. The flow set-up operated in double-channel, carrying a 5.0x10-4 M IO- 4 solution and a suitable buffer; these were mixed in a 50-cm reaction coil. The overall flow rate was 7 ml min-1 and the injection volume 70 µl. Under these conditions, a linear behaviour against concentration was observed for 17.7–194.0 µg ml-1, presenting slopes of 0.169 mV (mg/l)-1, a reproducibility of ±1.1 mV (n = 5), and a sampling rate of ~96 samples h-1. The proposed method was applied to the analysis of beverages and pharmaceuticals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports the amount and estimated daily mineral intake of nine elements (Ca, Mg, K, Na, P, Fe, Mn, Cr and Ni) in commercial instant coffees and coffee substitutes (n = 49). Elements were quantified by high-resolution continuum source flame (HR-CS-FAAS) and graphite furnace (HR-CS-GFAAS) atomic absorption spectrometry, while phosphorous was evaluated by a standard vanadomolybdophosphoric acid colorimetric method. Instant coffees and coffee substitutes are rich in K, Mg and P (>100 mg/100 g dw), contain Na, Ca and Fe in moderate amounts (>1 mg/100 g), and trace levels of Cr and Ni. Among the samples analysed, plain instant coffees are richer in minerals (p < 0.001), except for Na and Cr. Blends of coffee substitutes (barley, malt, chicory and rye) with coffee (20–66%) present intermediate amounts, while lower quantities are found in substitutes without coffee, particularly in barley. From a nutritional point of view the results indicate that the mean ingestion of two instant beverages per day (total of 4 g instant powder), either with or without coffee, cannot be regarded as important sources of minerals to the human diet, although providing a supplementation of some minerals, particularly Mg and Mn in instant coffees. Additionally, and for authentication purposes, the correlations observed between some elements and the coffee percentage in the blends, with particular significance for Mg amounts, provides a potential tool for the estimation of coffee in substitute blends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tecnologia de barreiras reactivas é uma alternativa possível de ser implementada para tratamento de águas contaminadas com compostos organoclorados, nomeadamente o tricloroetileno (TCE). O recurso a ferro zerovalente (Fe0) como meio reactivo tem na actualidade inúmeras aplicações, tratando-se de uma reacção de desalogenação por mecanismo de oxidação-redução. Neste trabalho fizeram-se estudos em batch da reacção entre o Fe0 e o TCE de forma a conhecer os parâmetros cinéticos. A natureza e a área da superfície do ferro provaram ser determinantes na velocidade da reacção. Foi possível verificar que para o sistema ferro comercial / TCE a ordem da reacção é inferior a um, e a constante cinética da ordem de 10-2 Lm-2h-1. Para simular uma barreira reactiva, projectaram-se e construíram-se colunas, as quais foram cheias com areia e ferro depois de devidamente misturados, uma vez que se tratou da disposição a que corresponderam melhores eficiências de redução do TCE. Não foi possível estabelecer o mecanismo da reacção, nem conhecer os parâmetros cinéticos, pelas dificuldades experimentais encontradas na análise do TCE e pelo facto de se tratar de uma reacção muito lenta. A cromatografia gasosa com detector de ionização de chama provou ser o método mais apropriado para doseamento do TCE em águas contaminadas, nas condições usadas neste estudo. A elevada volatilização do TCE e a baixa solubilidade em água contribuíram para as dificuldades operacionais encontradas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, rapid, and precise amperometric method for quantification of N-methylcarbamate pesticides in water samples and phytopharmaceuticals is presented. Carbofuran and fenobucarb are the target analytes. The method is developed in flow conditions providing the anodic oxidation of phenolic-based compounds formed after alkaline hydrolysis. Optimization of instrumental and chemical variables is presented. Under the optimal conditions, the amperometric signal is linear for carbofuran and fenobucarb concentrations over the range of 1.0*10-7 to 1.0*10-5 molL-1, with a detection limit of about 2 ngmL-1. The amperometric method is successfully applied to the analysis of spiked environmental waters and commercial formulations. The proposed method allows 90 samples to be analysed per hour, using 500 mL of sample, and producing wastewaters of low toxicity. The proposed method permits determinations at the mgL 1 level and offers advantages of simplicity, accuracy, precision, and applicability to coloured and turbid samples, and automation feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concentrations of eleven trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) were measured in 39 (natural and flavoured) water samples. Determinations were performed using graphite furnace electrothermetry for almost all elements (Al, As, Cd, Cr, Co, Mn, Ni, Pb, and Si). For Se determination hydride generation was used, and cold vapour generation for Hg. These techniques were coupled to atomic absorption spectrophotometry. The trace element content of still or sparkling natural waters changed from brand to brand. Significant differences between natural still and natural sparkling waters (p<0.001) were only apparent for Mn. The Mann–Whitney U-test was used to search for significant differences between flavoured and natural waters. The concentration of each element was compared with the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. It was shown that flavoured waters generally increase the trace element content. The addition of preservatives and acidifying regulators had a significant influence on Mn, Co, As and Si contents (p<0.05). Fruit juice can also be correlated to the increase of Co and As. Sweeteners did not provide any significant difference in Mn, Co, Se and Si content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The immobilization and electro-oxidation of guanine and adenine asDNA bases on glassy carbon electrode are evaluated by square wave voltammetric analysis. The influence of electrochemical pretreatments, nature of supporting electrolyte, pH, accumulation time and composition of DNA nucleotides on the immobilization effect and the electrochemical mechanism are discussed. Trace levels of either guanine or adenine can be readily detected following short accumulation time with detection limits of 35 and 40 ngmL−1 for guanine and adenine, respectively. The biosensors of guanine and adenine were employed for the voltammetric detection of antioxidant capacity in flavored water samples. The method relies on monitoring the changes of the intrinsic anodic response of the surface-confined guanine and adenine species, resulting from its interaction with free radicals from Fenton-type reaction in absence and presence of antioxidant. Ascorbic acid was used as standard to evaluate antioxidant capacities of samples. Analytical data was compared with that of FRAP method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Macro (Ca, Mg, K, Na) and micromineral (Fe, Zn, Cu) composition of 39 waters was analysed. Determinations were made by atomic flame spectrophotometry for macrominerals and electrothermic atomisation in graphite furnace for microminerals. Mineral contents of still or sparkling natural waters (without flavours) changed from brand to brand. Mann–Whitney test was used to search for significant differences between flavoured and natural waters. For that, the concentration of each mineral was compared to the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. The statistical study demonstrated that flavoured waters generally have increased contents of K, Na, Fe and Cu. The added preservatives also led to significant differences in the mineral composition. Acidifying agents and fruit juice can also be correlated to the increase of Mg, K, Na, Fe and Cu. Sweeteners do not provide any significant difference in Ca, Mg, Fe and Zn contents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 µL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min–1. Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10–6 to 5.0x10–5 mol L–1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h–1. The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a biosensor based on a glassy carbon electrode (GCE) was used for the evaluation of the total antioxidant capacity (TAC) of flavours and flavoured waters. This biosensor was constructed by immobilising purine bases, guanine and adenine, on a GCE. Square wave voltammetry (SWV) was selected for the development of this methodology. Damage caused by the reactive oxygen species (ROS), superoxide radical (O2·−), generated by the xanthine/xanthine oxidase (XOD) system on the DNA-biosensor was evaluated. DNA-biosensor encountered with oxidative lesion when it was in contact with the O2·−. There was less oxidative damage when reactive antioxidants were added. The antioxidants used in this work were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants are capable of scavenging the superoxide radical and therefore protect the purine bases immobilized on the GCE surface. The results demonstrated that the DNA-based biosensor is suitable for the rapid assess of TAC in beverages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antioxidant profiles of 39 water samples (29 flavored waters based on 10 natural waters) and 6 flavors used in their formulation (furnished by producers) were determined. Total phenol and flavonoid contents, reducing power, and DPPH radical scavenging activity were the optical techniques implemented and included in the referred profile. Flavor extracts were analyzed by HS-SPME/GC-MS to obtain the qualitative and quantitative profiles of the volatile fraction of essential oils. Results pointed out a higher reducing power (0.14 11.8 mg of gallic acid/L) and radical scavenging activity (0.29 211.5 mg Trolox/L) of flavored waters compared with the corresponding natural ones, an interesting fact concerning human health. Bioactive compounds, such as polyphenols, were present in all samples (0.5 359 mg of gallic acid/L), whereas flavonoids were not present either in flavored waters or in flavors. The major components of flavor extracts were monoterpenes, such as citral, R-limonene, carveol, and R-terpineol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of 18 polycyclic aromatic hydrocarbons (PAHs) were determined in five commercially valuable squid species from different geographical origins (Atlantic, Indic and Pacific Oceans). Out of the 18 quantified PAHs (the 16 PAHs considered by US EPA as priority pollutants, dibenzo(a,l)pyrene and benzo(j)fluoranthene) only dibenz(a,h)anthracene was not detected. The total concentrations of PAHs varied by a factor of more than 100-fold, from 0.22 (Loligo gahi) to 60.9 lg/kg ww (Loligo reynaudii). Intraand inter-specific variability of PAH levels was statistically assessed. Nine carcinogenic (probable/possible) PAHs accounted for 1% (L. reynaudii) to 26% (Loligo opalescens) of the total PAHs content being the main contributors naphthalene (in Loligo duvaucelii, L. reynaudii and Loligo vulgaris species), chrysene (in L. opalescens) and indeno(1,2,3-cd)pyrene (in L. gahi). PAHs source analysis indicated that four of the five zones of capture of the different squid species are significantly affected by both petrogenic and pyrolytic sources. Assessment of the target carcinogenic risks, established by the US EPA, suggested that L. gahi (Atlantic Ocean) and L. opalescens (from Pacific Ocean) may pose additional risks for consumers, if not eaten in moderation, derived from benzo(a)pyrene ingestion.