9 resultados para Antenna miniaturization
em Instituto Politécnico do Porto, Portugal
Resumo:
4th International Conference on Future Generation Communication Technologies (FGCT 2015), Luton, United Kingdom.
Resumo:
With progressing CMOS technology miniaturization, the leakage power consumption starts to dominate the dynamic power consumption. The recent technology trends have equipped the modern embedded processors with the several sleep states and reduced their overhead (energy/time) of the sleep transition. The dynamic voltage frequency scaling (DVFS) potential to save energy is diminishing due to efficient (low overhead) sleep states and increased static (leakage) power consumption. The state-of-the-art research on static power reduction at system level is based on assumptions that cannot easily be integrated into practical systems. We propose a novel enhanced race-to-halt approach (ERTH) to reduce the overall system energy consumption. The exhaustive simulations demonstrate the effectiveness of our approach showing an improvement of up to 8 % over an existing work.
Resumo:
Nos últimos anos, o avanço da tecnologia e a miniaturização de diversos componentes de electrónica associados a novos conceitos têm permitido nascer novas ideias e projectos, que até há alguns anos não passariam de ficção científica. Talvez o exemplo mais acabado seja actualmente o smartphone, um pequeno bloco de hardware e software, com capacidade de processamento que ultrapassa várias vezes o dos computadores com uma dúzia de anos. Estas capacidades têm sido utilizadas em comunicações, blocos de notas, agendas e até entretenimento. No entanto, podem ser reutilizadas para ajudar a resolver algumas limitações/constrangimentos da actualidade. Dentro destes destacam-se a gestão de recursos escassos. Com efeito, o consumo de energia eléctrica tem aumentado como consequência directa do desenvolvimento global e aumento do número de aparelhos eléctricos. Uma percentagem significativa de energia eléctrica tem sido produzida através de recursos não-renováveis de energia. No entanto, a dependência energética, associada à subida de preços e a redução das emissões de gases do efeito estufa, estimula o desenvolvimento de novas soluções que permitam lidar com esta situação. O desempenho energético por sua vez depende não só das características da estrutura, mas também do comportamento do utilizador. O desempenho energético dos edifícios é muito importante, uma vez que os respectivos consumos são responsáveis por mais de metade do total da energia produzida. Desta forma, a fim de alcançar um melhor desempenho é importante não só considerar o desempenho de estrutura, mas também monitorizar o comportamento do utilizador. Esta última questão coloca várias limitações, uma vez que depende muito do tipo de utilizador. Um dos conceitos actuais emergentes são as chamadas redes de sensores sem fio. Com esta tecnologia, pequenos módulos podem ser desenvolvidos com muitas possibilidades de conectividade, com elevado poder de processamento e com grande autonomia, sem serem excessivamente caros. Isto proporciona os meios para implementar vários dispositivos em toda a instalação, para recolher uma variedade de dados, sendo posteriormente armazenados num servidor. Os blocos fundamentais da infra-estrutura de sensores do projecto foram concebidos na Evoleo Technologies em simultâneo com o decorrer do estágio. Estes blocos recolhem dados específicos na instalação, e periodicamente enviam para o servidor central os valores recolhidos, onde são armazenados e colocados à disposição do utilizador. Os dados recolhidos podem então ser apresentados ao utilizador, proporcionando um registo de consumo de energia associado a um dado período de tempo. Uma vez que todos os dados são armazenados no servidor, podem ser efectuados estudos para determinar o uso típico, possíveis problemas em aparelhos, a qualidade da energia eléctrica, etc., permitindo determinar onde a energia está a ser eventualmente desperdiçada e fornecendo dados ao utilizador para que este possa proceder a alterações, tendo por base dados recolhidos num dado período. O objectivo principal deste trabalho passa por estabelecer a ligação entre o nível máquina e o nível de utilizador, isto é, uma plataforma de interacção entre dispositivos e administrador da instalação. Fornecer os dados de uma forma fácil e sem necessidade de instalação de software específico em cada dispositivo que se pretenda utilizar para monitorizar foi uma das principais preocupações das fases de concepção do projecto.
Resumo:
Nos últimos anos, o avanço da tecnologia e a miniaturização de diversos componentes têm permitido o aparecimento de novos conceitos, ideias e projetos, que até aqui não passariam de filmes de ficção científica. Com a tecnologia atual, podem ser desenvolvidos pequenos dispositivos wearable com diversas interfaces, múltiplas conectividades, poder de processamento e autonomia. Permitindo desta forma, dar resposta à crescente necessidade de interação com os mais diversos equipamentos eletrónicos do dia-a-dia, melhorando o acesso e o fornecimento de informação. O principal objetivo deste trabalho passa assim por demonstrar e implementar um conceito que permita estreitar e facilitar a interação entre o utilizador e o mundo que o rodeia, quer em ambientes domésticos quer industriais. Para isso foi projetado e implementado um dispositivo wearable (para utilização no pulso) baseado numa arquitetura de hardware e software capaz de correr diferentes aplicações, tais como extensão de alertas de um smartphone, crowdsourcing de informações meteorológicas, manutenção e inspeção industrial e monitorização remota de forças de segurança. Os resultados obtidos demonstram que este conceito é viável tanto do ponto de vista técnico como funcional, evidenciando boas hipóteses para que estes conceitos, métodos e tecnologias possam ser integradas em plataformas robóticas desenvolvidas no âmbito de projetos do Laboratório de Sistemas Autónomos (LSA) bem como nos contextos industrial e de lazer.
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
RTUWO Advances in Wireless and Optical Communications 2015 (RTUWO 2015). 5-6 Nov Riga, Latvia.
Resumo:
A evolução tecnológica atingiu um ritmo que muitas empresas têm dificuldade de acompanhar, existem diversas opções no mercado, para um mesmo objectivo, e tornasse determinante o processo de tomada de decisão sobre qual tecnologia adoptar para determinado objectivo. O alvo de estudo desta dissertação de mestrado, é uma das tecnologias, que últimamente tem ganho especial relevo, quando aplicada ao ambiente industrial, o RFID (Radio Frequency Identification Devices). Na presente dissertação, foi efectuado um levantamento do estado da arte, na área da identificação automática, com especial foco no RFID. Esta revisão bibliográfica teve como principal objectivo perceber quais as tecnologias concorrentes do RFID, e explorar quais as suas principais características tecnológicas e funcionais, bem como as vantagens no uso desta tecnologia de forma a sustentar a implementação de um sistema protótipo de gestão de armazém. O contributo final da dissertação, consiste numa aplicação que tem como principal objectvo simular os fluxos de infomação resultantes dos fluxos fisícos de materiais em ambiente de armazém. Foi também tido em conta no desenvolvimento da aplicação, a demonstração de algumas das mais valias que esta tecnologia pode trazer para a gestão de armazéns. Para implementação da aplicação destaca-se a utilização da arquitectura MVC (Model-view-controlador), em ambiente web, para permitir uma descentalização do software no ambiente indoor do armazém.
Resumo:
A indústria de semicondutores é um sector em permanente evolução tecnológica. A tendência de miniaturização e de otimização do espaço, a necessidade de produzir circuitos cada vez mais complexos, a tendência para o incremento do número de camadas em cada circuito integrado, são as condições necessárias para que a evolução tecnológica nesta área seja uma constante. Os processos ligados à produção de semicondutores estão também em permanente evolução, dada a pressão efetuada pelas necessidades acima expostas. Os equipamentos necessitam de uma crescente precisão, a qual tem que ser acompanhada de procedimentos rigorosos para que a qualidade atingida tenha sempre o patamar desejado. No entanto, a constante evolução nem sempre permite um adequado levantamento de todas as causas que estão na origem de alguns problemas detetados na fabricação de semicondutores. Este trabalho teve por objetivo efetuar um levantamento dos processos ligados ao fabrico de semicondutores a partir de uma pastilha de silício (wafer) previamente realizada, identificando para cada processo os possíveis defeitos introduzidos pelo mesmo, procurando inventariar as causas possíveis que possam estar na origem desse defeito e realizar procedimentos que permitam criar regras e procedimentos perfeitamente estabelecidos que permitam aprender com os erros e evitar que os mesmos problemas se possam vir a repetir em situações análogas em outros produtos de uma mesma família.