131 resultados para technologic limit
Resumo:
Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.
Resumo:
Silica based nanostructured composite materials doped with luminol and cobalt(II) ion were synthesized and characterized, resulting in a highly chemiluminescent material in the presence of hydrogen peroxide. A detection system with the CL light guided from the reaction tube to the photomultiplier tube using a one millimeter glass optical fiber was developed and assessed. A linear response was observed using a semi-logarithm calibration between 50–2000 µM hydrogen peroxide with 1 µM as the limit of detection.
Resumo:
A novel biomimetic sensor for the potentiometric transduction of oxytetracycline is presented. The artificial host was imprinted in methacrylic acid and/or acrylamide based polymers. Different amounts of molecularly imprinted and non-imprinted polymers were dispersed in different plasticizing solvents and entrapped in a poly(vinyl chloride) matrix. Only molecularly imprinted based sensors allowed a potentiometric transduction, suggesting the existence of host–guest interactions. These sensors exhibited a near-Nernstian response in steady state evaluations; slopes and detection limits ranged 42–63 mV/decade and 2.5–31.3 µg/mL, respectively. Sensors were independent from the pH of test solutions within 2–5. Good selectivity was observed towards glycine, ciprofloxacin, creatinine, acid nalidixic, sulfadiazine, cysteine, hydroxylamine and lactose. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (65 mV/decade), wide linear range (5.0×10−5 to 1.0×10−2 mol/L), low detection limit (19.8 µg/mL), and a stable baseline for a 5×10−3M citrate buffer (pH 2.5) carrier. The sensors were successfully applied to the analysis of drugs and urine. This work confirms the possibility of using molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.
Resumo:
A presente dissertação consiste em verificar a tendência do coeficiente de segurança quando se varia certos parâmetros (ângulo de atrito interno do terreno, inclinação do terrapleno no tardoz do muro e o ângulo que a massa de solo faz quando se comporta como parte integrante do muro numa situação limite) considerados no cálculo. Para atingir os objectivos anteriormente referidos, dividiu-se o trabalho em duas fases, a primeira fase teve como objectivo verificar qual a tendência do coeficiente de segurança quando sujeito à variação de dois parâmetros, o ângulo de atrito interno do terreno e a inclinação do terrapleno no tardoz do muro que varia de 5° até ao valr do ângulo de atrito interno do terreno. A segunda fase consiste em analisar qual a tendência do coeficiente de segurança quando sujeito à variação de três parâmetros, o ângulo de atrito interno do terreno, de 20° a 45°, a inclinação do terrapleno no tardoz do muro, de 10° até ao valor do ângulo de atrito interno do terreno, e o ângulo que a massa de solo faz quando se comporta como parte integrante do muro numa situação limite. Para ambas as situações efectuaram-se os respectivos cálculos quer pela Teoria de Rankine e quer pela Teoria de Mohr – Coulomb, havendo casos em que foi necessário conjugar estas duas Teorias.
Resumo:
The Quinone outside Inhibitors (QoI) are one of the most important and recent fungicide groups used in viticulture and also allowed by Integrated Pest Management. Azoxystrobin, kresoxim-methyl and trifloxystrobin are the main active ingredients for treating downy and powdery mildews that can be present in grapes and wines. In this paper, a method is reported for the analysis of these three QoI-fungicides in grapes and wine. After liquid–liquid extraction and a clean-up on commercial silica cartridges, analysis was by isocratic HPLC with diode array detection (DAD) with a run time of 13 min. Confirmation was by solid-phase micro-extraction (SPME), followed by GC/MS determination. The main validation parameters for the three compounds in grapes and wine were a limit of detection up to 0.073mg kg-1, a precision not exceeding 10.0% and an average recovery of 93% ±38.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação de Mestre Armindo Licínio da Silva Macedo
Resumo:
Dissertação para a obtenção do Grau de Mestre em Contabilidade e Finanças Orientador: Mestre Adalmiro Álvaro Malheiro de Castro Andrade Pereira
Resumo:
Dissertação apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria Orientada por: Mestre Carlos Martins
Resumo:
A presente dissertação endereça o desenvolvimento de um sistema de visão stereo ativo para os robôs de futebol robótico da equipa ISePorto do ISEP, de modo a que estes tirem o máximo partido das câmaras rotativas neles existentes. Este trabalho surge da necessidade de melhorar a capacidade de perceção do ambiente por parte dos robôs, principalmente da perceção da bola quando não está no plano do campo e dos robôs adversários. Esta necessidade surge devido ao aumento da dinâmica que se tem vindo a veri car ultimamente nas competições. Para tal, foram estudados algumas trabalhos relacionados no que diz respeito a sistemas de visão stereo com baselines variáveis e eixos de rotação em ambas as câmaras, bem como fundamentos de visão stereo. Foi proposta uma arquitetura para o sistema de visão ativo de modo a ser aplicado em qualquer robô da equipa MSL (Middle Size League). Para tornar possível a implementação desta arquitetura foi desenvolvido um procedimento para a calibração e determinação em tempo real dos parâmetros extrínsecos do par stereo em função da posição angular dos eixos rotativos do robô. O sistema de visão foi também dotado de capacidade de sincronismo e foram implementadas funcionalidades ao nível de software que possibilitam a deteção de objetos na imagem, a correspondência de objetos presentes nas imagens de ambas as câmaras e consequentemente a determinação das posições tridimensionais desses objetos relativamente ao robô. O sistema desenvolvido foi testado e validado em cenário MSL ao nível de perceção da bola, robôs adversários e linhas do campo. Os resultados obtidos apresentam uma melhoria signi cativa, face à implementação atual dos robôs, na perceção tridimensional da bola quando não está no plano do campo, e dos robôs adversários.
Resumo:
This study focused on the occurrence of several EDCs including bisphenol A, estrone (E1), the 17b-estradiol (E2) and 17a- thinylestradiol (EE2) in fourteen rivers of Portugal. Samples analysis revealed a widespread contamination of BPA especially in Ave, Cávado, Douro, Ferro, Sousa and Vizela Rivers. Achieving 98.4 ng/L for the highest concentration. The estrogens achieved above the method quantification limit (MQL) were E1 in Águeda River and E2 in Ave, Lima and Tâmega Rivers. The maximum concentration detected for E1 was 26.9 ng/L. EE2 was detected only below MQL.
Resumo:
This study focused on the development of a sensitive enzymatic biosensor for the determination of pirimicarb pesticide based on the immobilization of laccase on composite carbon paste electrodes. Multi- walled carbon nanotubes(MWCNTs)paste electrode modified by dispersion of laccase(3%,w/w) within the optimum composite matrix(60:40%,w/w,MWCNTs and paraffin binder)showed the best performance, with excellent electron transfer kinetic and catalytic effects related to the redox process of the substrate4- aminophenol. No metal or anti-interference membrane was added. Based on the inhibition of laccase activity, pirimicarb can be determined in the range 9.90 ×10- 7 to 1.15 ×10- 5 molL 1 using 4- aminophenol as substrate at the optimum pH of 5.0, with acceptable repeatability and reproducibility (relative standard deviations lower than 5%).The limit of detection obtained was 1.8 × 10-7 molL 1 (0.04 mgkg 1 on a fresh weight vegetable basis).The high activity and catalytic properties of the laccase- based biosensor are retained during ca. one month. The optimized electroanalytical protocol coupled to the QuEChERS methodology were applied to tomato and lettuce samples spiked at three levels; recoveries ranging from 91.0±0.1% to 101.0 ± 0.3% were attained. No significant effects in the pirimicarb electro- analysis were observed by the presence of pro-vitamin A, vitamins B1 and C,and glucose in the vegetable extracts. The proposed biosensor- based pesticide residue methodology fulfills all requisites to be used in implementation of food safety programs.
Resumo:
A glutathione-S-transferase (GST)based biosensor was developed to quantify the thiocarbamate herbicide molinate in environmental water.The biosensor construction was based on GST immobilization onto a glassy carbon electrode via aminosilane–glutaraldehyde covalent attachment. The principle supporting the use of this biosensor consists of the GST inhibition process promoted by molinate. Differential pulse voltammetry was used to obtain a calibration curve for molinate concentration, ranging from 0.19 to 7.9 mgL -1 and presenting a detection limit of 0.064 mgL- 1. The developed biosensor is stable,and reusable during 15 days.The GST-based biosensor was successfully applied to quantify molinate in rice paddy field floodwater samples. The results achieved with the developed biosensor were in accordance with those obtained by high performance liquid chromatography. The proposed device is suitable for screening environmental water analysis and, since no sample preparation is required, it can be used in situ and in real-time measurements.
Resumo:
The present work describes the development of an analytical method for the determination of methiocarb and its degradation products (methiocarb sulfoxide and methiocarb sulfone) in banana samples, using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure followed by liquid chromatography coupled to photodiode array detector (LCPAD). Calibration curves were linear in the range of 0.5−10 mg L−1 for all compounds studied. The average recoveries, measured at 0.1 mg kg−1 wet weight, were 92.0 (RSD = 1.8%, n = 3), 84.0 (RSD = 3.9%, n = 3), and 95.2% (RSD = 1.9%, n = 3) for methiocarb sulfoxide, methiocarb sulfone, and methiocarb, respectively. Banana samples treated with methiocarb were collected from an experimental field. The developed method was applied to the analysis of 24 samples (peel and pulp) and to 5 banana pulp samples. Generally, the highest levels were found for methiocarb sulfoxide and methiocarb. Methiocarb sulfone levels were below the limit of quantification, except in one sample (not detected).
Resumo:
QuEChERS original method was modified into a new version for pesticides determination in soils. The QuEChERS method is based on liquid–liquid portioning with ACN and was followed by cleanup step using dispersive SPE and disposable pipette tips. Gas chromatographic separation with MS detection was carried out for pesticides quantification. The method was validated using recovery experiments for 36 multiclass pesticides. Mean recoveries of pesticides at each of the four spiking levels between 10–300 µg/kg of soil ranged from 70–120% for 26 pesticides with RSD values less than 15%. The method achieved low limit of detection less than 7.6 µ g/kg. Matrix effects were observed for 13 pesticides. Matrix effects were compensated by using matrix-matched calibration. The method was applied successfully using d-SPE or DPX in the analysis of the pesticides in soils from organic farming and integrated pest management.
Resumo:
An optimised version of the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method for simultaneous determination of 14 organochlorine pesticides in carrots was developed using gas chromatography coupled with electron-capture detector (GC-ECD) and confirmation by gas chromatography tandem mass spectrometry (GC-MS/MS). A citrate-buffered version of QuEChERS was applied for the extraction of the organochlorine pesticides, and for the extract clean-up, primary secondary amine, octadecyl-bonded silica (C18), magnesium sulphate (MgSO4) and graphitized carbon black were used as sorbents. The GC-ECD determination of the target compounds was achieved in less than 20 min. The limits of detection were below the EUmaximum residue limits (MRLs) for carrots, 10–50 μg kg−1, while the limit of quantification did exceed 10 μg kg−1 for hexachlorobenzene (HCB). The introduction of a sonication step was shown to improve the recoveries. The overall average recoveries in carrots, at the four tested levels (60, 80, 100 and 140 μg kg−1), ranged from 66 to 111% with relative standard deviations in the range of 2– 15 % (n03) for all analytes, with the exception of HCB. The method has been applied to the analysis of 21 carrot samples from different Portuguese regions, and β-HCH was the pesticide most frequently found, with concentrations oscillating between less than the limit of quantification to 14.6 μg kg−1. Only one sample had a pesticide residue (β-HCH) above the MRL, 14.6 μg kg−1. This methodology combines the advantages of both QuEChERS and GC-ECD, producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.