87 resultados para Electronic Educational Materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the quality of a b-learning environment is critical to determine the success of a b-learning course. There are a lot of materials related to the quality process, namely different approaches and perspectives but none of them is specific of the product of a b-learning context. In this paper we identify the indicators that should be analyzed in order to determine the quality of a b-learning course, since its success reflect not only the student’s perception, but also what should be taken into account. B-Learning environments are relatively new and combine educational characteristics with technological elements that support the learning process and the training delivery. Our main objective is to know what a high quality b-learning environment is in students’’ perception and what are the main quality dimensions of these courses, in the perspective of the products and services offered. After a literature review concerning the quality process and in particular the b-learning quality field, a structure that provides the main elements that should be evaluated by students when we are measuring the quality and the success of b-learning product/services was created. The structure obtained was applied to a case study of the Polytechnic Institute of Oporto. Results presented will help institutions to deliver services with more quality and improve their long-term competitiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass fibre-reinforced plastics (GFRP) have been considered inherently difficult to recycle due to both: crosslinked nature of thermoset resins, which cannot be remoulded, and complex composition of the composite itself. Presently, most of the GFRP waste is landfilled leading to negative environmental impacts and supplementary added costs. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. In this study, efforts were made in order to recycle grinded GFRP waste, proceeding from pultrusion production scrap, into new and sustainable composite materials. For this purpose, GFRP waste recyclates, were incorporated into polyester based mortars as fine aggregate and filler replacements at different load contents and particle size distributions. Potential recycling solution was assessed by mechanical behaviour of resultant GFRP waste modified polymer mortars. Results revealed that GFRP waste filled polymer mortars present improved flexural and compressive behaviour over unmodified polyester based mortars, thus indicating the feasibility of the GFRP industrial waste reuse into concrete-polymer composite materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the past few years we have witnessed the fast development of distance learning tools such as Open Educational Resources (OER) and Massive Open Online Courses (MOOCs). This paper presents the “Mathematics without STRESS” MOOC Project, which is a cooperation between four schools from the Polytechnic Institute of Oporto (IPP). The concepts of MOOC and their quickly growing popularity are presented and complemented by a discussion of some MOOC definitions. The process of the project development is demonstrated by focusing on used MOOC structure, as well as the several types of course materials produced. At last, is presented a short discussion about problems and challenges met throughout the project. It is also our goal to contribute for a change in the way as teaching and learning Mathematics is seen and practiced nowadays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nos últimos anos, o processo de ensino e aprendizagem tem sofrido significativas alterações graças ao aparecimento da Internet. Novas ferramentas para apoio ao ensino têm surgido, nas quais se destacam os laboratórios remotos. Atualmente, muitas instituições de ensino disponibilizam laboratórios remotos nos seus cursos, que permitem, a professores e alunos, a realização de experiências reais através da Internet. Estes são implementados por diferentes arquiteturas e infraestruturas, suportados por vários módulos de laboratório acessíveis remotamente (e.g. instrumentos de medição). No entanto, a sua inclusão no ensino é ainda deficitária, devido: i) à falta de meios e competências técnicas das instituições de ensino para os desenvolverem, ii) à dificuldade na partilha dos módulos de laboratório por diferentes infraestruturas e, iii) à reduzida capacidade de os reconfigurar com esses módulos. Para ultrapassar estas limitações, foi idealizado e desenvolvido no âmbito de um trabalho de doutoramento [1] um protótipo, cuja arquitetura é baseada na norma IEEE 1451.0 e na tecnologia de FPGAs. Para além de garantir o desenvolvimento e o acesso de forma normalizada a um laboratório remoto, este protótipo promove ainda a partilha de módulos de laboratório por diferentes infraestruturas. Nesse trabalho explorou-se a capacidade de reconfiguração de FPGAs para embutir na infraestrutura do laboratório vários módulos, todos descritos em ficheiros, utilizando linguagens de descrição de hardware estruturados de acordo com a norma IEEE 1451.0. A definição desses módulos obriga à criação de estruturas de dados binárias (Transducer Electronic Data Sheets, TEDSs), bem como de outros ficheiros que possibilitam a sua interligação com a infraestrutura do laboratório. No entanto, a criação destes ficheiros é bastante complexa, uma vez que exige a realização de vários cálculos e conversões. Tendo em consideração essa mesma complexidade, esta dissertação descreve o desenvolvimento de uma aplicação Web para leitura e escrita dos TEDSs. Para além de um estudo sobre os laboratórios remotos, é efetuada uma descrição da norma IEEE 1451.0, com particular atenção para a sua arquitetura e para a estrutura dos diferentes TEDSs. Com o objetivo de enquadrar a aplicação desenvolvida, efetua-se ainda uma breve apresentação de um protótipo de um laboratório remoto reconfigurável, cuja reconfiguração é apoiada por esta aplicação. Por fim, é descrita a verificação da aplicação Web, de forma a tirar conclusões sobre o seu contributo para a simplificação dessa reconfiguração.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the past few years we have witnessed astonishing developments on distance learning tools, in particular on Open Educational Resources (OER) such as Massive Open Online Courses (MOOC). In this paper we present the “Mathematics without STRESS”, a MOOC Project, which has been a collaborative volunteer effort that brought together professors, from four schools of the Polytechnic Institute of Oporto (IPP), in Portugal. Some concepts directly associated with MOOC and their quickly growing popularity are complemented with a discussion of some particular MOOC characterizations. The design process of this project is revealed by focusing on the MOOC structure we used, as well as on the several types of course materials that were produced. At last, we undertake a short discussion about some of the problems, achievements and challenges met throughout this project development, giving a special attention to the motivational aim of this work - hoping to contribute to a change in the way of teaching and learning Mathematics is seen and practiced nowadays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A aplicação do material compósito é neste momento bastante vasta, graças à combinação das suas características específicas, tais como, maior resistência específica e módulos específicos e melhor resistência à fadiga, quando comparados com os metais convencionais. Tais características, quando requeridas, tornam este material ideal para aplicações estruturais. Esta caminhada de sucesso iniciou desde muito cedo, quando o material compósito já era utilizado para fabrico de armas pelos mongóis e na construção civil pelos hebreus e egípcios, contudo, só a partir dos meados do século XX é que despertou interesses para aplicações mais modernas. Atualmente os materiais compósitos são utilizados em equipamentos domésticos, componentes elétricos e eletrónicos, passando por materiais desportivos, pela indústria automóvel e construção civil, até indústrias de grande exigência e visibilidade tecnológica como a aeronáutica, espacial e de defesa. Apesar das boas características apresentadas pelos materiais compósitos, no entanto, estes materiais têm tendência a perderem as suas propriedades quando submetidas a algumas operações de acabamento como a furação. A furação surge da necessidade de ligação de peças de um mesmo mecanismo. Os furos obtidos por este processo devem ser precisos e sem danos para garantir ligações de alta resistência e também precisas. A furação nos materiais compósitos é bastante complexa devido à sua heterogeneidade, anisotropia, sensibilidade ao calor e pelo facto de os reforços serem extremamente abrasivos. A operação de furação pode causar grandes danos na peça, como a delaminação a entrada, defeitos de circularidade do furo, danos de origem térmica e a delaminação à saída que se apresenta como o mais frequente e indesejável. Com base nesses pressupostos é que este trabalho foi desenvolvido de forma a tentar obter processos simples para determinação e previsão de danos em polímeros reforçados com fibras (de carbono neste caso) de forma a precavê-los. De forma a conseguir estes objetivos, foram realizados ensaios de início de delaminação segundo a proposta de Lachaud et al. e ensaios de pin-bearing segundo a proposta de Khashaba et al. Foram também examinadas extensões de danos de acordo com o modelo de Fator de delaminação ajustado apresentado por Davim et al. A partir dos ensaios, de pin-bearing, realizados foram analisadas influências do material e geometria da broca, do avanço utilizado na furação e de diferentes orientações de empilhamentos de placas na delaminação de laminados compósitos e ainda a influências dessas variáveis na força de rutura por pin-bearing. As principais conclusões tiradas daqui são que a delaminação aumenta com o aumento do avanço, o que já era esperado, as brocas em carboneto de tungsténio são as mais recomendas para a furação do material em causa e que a delaminação é superior para a placa cross-ply quando comparada com placas unidirecionais. Para a situação de ensaios de início de delaminação foram analisadas as influências da variação da espessura não cortada por baixo da broca/punção, de diferentes geometrias de brocas, da alteração de velocidade de ensaio e diferentes orientações de empilhamentos de placas na força de início de delaminação. Deste ensaio as principais conclusões são que a força de início de delaminação aumenta com o aumenta da espessura não cortada e a influência da velocidade de ensaio altera com a variação das orientações de empilhamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this EPS@ISEP project proposed in the Spring of 2014 was to develop a flapping wing flying robot. The project was embraced by a multinational team composed of four students from different countries and fields of study. The team designed and implemented a robot inspired by a biplane design, constructed from lightweight materials and battery powered. The prototype, called MyBird, was built with a 250 € budget, reuse existing materials as well as low cost solutions. Although the team's initial idea was to build a light radio controlled robot, time limitations along with setbacks involving the required electrical components led to a light but not radio controlled prototype. The team, from the experience gathered, made a number of future improvement suggestions, namely, the addition of radio control and a camera and the adoption of articulated monoplane design instead of the current biplane design for the wings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a novel surface Smart Polymer Antibody Material (SPAM) for Carnitine (CRT, a potential biomarker of ovarian cancer), tested for the first time as ionophore in potentiometric electrodes of unconventional configuration. The SPAM material consisted of a 3D polymeric network created by surface imprinting on graphene layers. The polymer was obtained by radical polymerization of (vinylbenzyl) trimethylammonium chloride and 4-styrenesulfonic acid (signaling the binding sites), and vinyl pivalate and ethylene glycol dimethacrylate (surroundings). Non-imprinted material (NIM) was prepared as control, by excluding the template from the procedure. These materials were then used to produce several plasticized PVC membranes, testing the relevance of including the SPAM as ionophore, and the need for a charged lipophilic additive. The membranes were casted over solid conductive supports of graphite or ITO/FTO. The effect of pH upon the potentiometric response was evaluated for different pHs (2-9) with different buffer compositions. Overall, the best performance was achieved for membranes with SPAM ionophore, having a cationic lipophilic additive and tested in HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) buffer, pH 5.1. Better slopes were achieved when the membrane was casted on conductive glass (-57.4 mV/decade), while the best detection limits were obtained for graphite-based conductive supports (3.6 × 10−5mol/L). Good selectivity was observed against BSA, ascorbic acid, glucose, creatinine and urea, tested for concentrations up to their normal physiologic levels in urine. The application of the devices to the analysis of spiked samples showed recoveries ranging from 91% (± 6.8%) to 118% (± 11.2%). Overall, the combination of the SPAM sensory material with a suitable selective membrane composition and electrode design has lead to a promising tool for point-of-care applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myoglobin (Mb) is among the cardiac biomarkers playing a major role in urgent diagnosis of cardiovascular diseases. Its monitoring in point-of-care is therefore fundamental. Pursuing this goal, a novel biomimetic ionophore for the potentiometric transduction of Mb is presented. It was synthesized by surface molecular imprinting (SMI) with the purpose of developing highly efficient sensor layers for near-stereochemical recognition of Mb. The template (Mb) was imprinted on a silane surface that was covalently attached to silica beads by means of self-assembled monolayers. First the silica was modified with an external layer of aldehyde groups. Then, Mb was attached by reaction with its amine groups (on the external surface) and subsequent formation of imine bonds. The vacant places surrounding Mb were filled by polymerization of the silane monomers 3-aminopropyltrimethoxysilane (APTMS) and propyltrimethoxysilane (PTMS). Finally, the template was removed by imine cleavage after treatment with oxalic acid. The results materials were finely dispersed in plasticized PVC selective membranes and used as ionophores in potentiometric transduction. The best analytical features were found in HEPES buffer of pH 4. Under this condition, the limits of detection were of 1.3 × 10−6 mol/L for a linear response after 8.0 × 10−7 mol/L with an anionic slope of −65.9 mV/decade. The imprinting effect was tested by preparing non-imprinted (NI) particles and employing these materials as ionophores. The resulting membranes showed no ability to detect Mb. Good selectivity was observed towards creatinine, sacarose, fructose, galactose, sodium glutamate, and alanine. The analytical application was conducted successfully and showed accurate and precise results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes different kind of solid-contact graphite-based electrodes for the selective determination of sulphonamides (SPHs) in pharmaceuticals, biological fluids and aquaculture waters. Sulfadiazine (SDZ) and sulfamethoxazole (SMX) were selected for this purpose for being the most representative compounds of this group. The template molecules were imprinted in sol–gel (ISG) and the resulting material was used as detecting element. This was made by employing it as either a sensing layer or an ionophore of PVC-based membranes and subsequent potentiometric transduction, a strategy never reported before. The corresponding non-imprinted sol–gel (NISG) membranes were used as blank. The effect of plasticizer and kind/charge of ionic lipophilic additive was also studied. The best performance in terms of slope, linearity ranges and signal reproducibility and repeatability was achieved by PVC membranes including a high dielectric constant plasticizer and 15 mg of ISG particles. The corresponding average slope was −51.4 and −52.4 mV/decade, linear responses were 9.0 × 10−6 and 1.7 × 10−5 M, and limits of detection were 0.74 and 1.3 μg/mL for SDZ and for SMX, respectively. Good selectivity with log Kpot < −0.3 was observed for carbonate, chloride, fluoride, hydrogenocarbonate, nitrate, nitrite, phosphate, cyanide, sulfate, borate, persulphate, citrate, tartrate, salicylate, tetracycline, ciprofloxacin, sulphamerazine, sulphatiazole, dopamine, glucose, galactose, cysteine and creatinine. The best sensors were successfully applied to the analysis of real samples with relative errors ranging from −6.8 to + 3.7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μg mL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μg mL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products.