120 resultados para IOL power calculation
Resumo:
Cloud computing is increasingly being adopted in different scenarios, like social networking, business applications, scientific experiments, etc. Relying in virtualization technology, the construction of these computing environments targets improvements in the infrastructure, such as power-efficiency and fulfillment of users’ SLA specifications. The methodology usually applied is packing all the virtual machines on the proper physical servers. However, failure occurrences in these networked computing systems can induce substantial negative impact on system performance, deviating the system from ours initial objectives. In this work, we propose adapted algorithms to dynamically map virtual machines to physical hosts, in order to improve cloud infrastructure power-efficiency, with low impact on users’ required performance. Our decision making algorithms leverage proactive fault-tolerance techniques to deal with systems failures, allied with virtual machine technology to share nodes resources in an accurately and controlled manner. The results indicate that our algorithms perform better targeting power-efficiency and SLA fulfillment, in face of cloud infrastructure failures.
Resumo:
Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia
Resumo:
A quinoxalina e seus derivativos são uma importante classe de compostos heterocíclicos, onde os elementos N, S e O substituem átomos de carbono no anel. A fórmula molecular da quinoxalina é C8H6N2, formada por dois anéis aromáticos, benzeno e pirazina. É rara em estado natural, mas a sua síntese é de fácil execução. Modificações na estrutura da quinoxalina proporcionam uma grande variedade de compostos e actividades, tais como actividades antimicrobiana, antiparasitária, antidiabética, antiproliferativa, anti-inflamatória, anticancerígena, antiglaucoma, antidepressiva apresentando antagonismo do receptor AMPA. Estes compostos também são importantes no campo industrial devido, por exemplo, ao seu poder na inibição da corrosão do metal. A química computacional, ramo natural da química teórica é um método bem desenvolvido, utilizado para representar estruturas moleculares, simulando o seu comportamento com as equações da física quântica e clássica. Existe no mercado uma grande variedade de ferramentas informaticas utilizadas na química computacional, que permitem o cálculo de energias, geometrias, frequências vibracionais, estados de transição, vias de reação, estados excitados e uma variedade de propriedades baseadas em várias funções de onda não correlacionadas e correlacionadas. Nesta medida, a sua aplicação ao estudo das quinoxalinas é importante para a determinação das suas características químicas, permitindo uma análise mais completa, em menos tempo, e com menos custos.
Resumo:
Actualmente, a sociedade depara-se com um enorme desafio: a gestão dos resíduos sólidos urbanos. A sua produção tem vindo a aumentar devido à intensificação das actividades humanas nas últimas décadas. A criação de um sistema de gestão dos resíduos é fundamental para definir prioridades nas acções e metas para que haja uma prevenção na produção de resíduos. Os resíduos sólidos urbanos quando dispostos de forma inadequada podem provocar graves impactos ambientais, tendo sido neste trabalho demonstrado que através de uma gestão eficiente destes é possível aproveitar o potencial energético do biogás e consequentemente diminuir o consumo de combustíveis fósseis reduzindo o impacto ambiental. Os aterros sanitários devem funcionar como a ultima etapa do sistema de tratamento dos resíduos sólidos urbanos e são uma alternativa a ter em conta se forem tomadas todas as medidas necessárias. Estima-se que os aterros sejam responsáveis pela produção de 6-20% do metano existente e que contribuam com 3-4% da produção anual de gases efeito de estufa provenientes de actividades antropogénicas1. É, portanto, fundamental proceder a uma impermeabilização do solo e à criação de condições para recolha do biogás produzido durante a decomposição dos resíduos. Foi estimada a produção de biogás, de acordo com o modelo “LandGEM”, no entanto comparando esta produção com a produção medida pelo explorador, constatou-se uma diferença significativa que pode ser justificada pelo: modo de funcionamento do aterro (longos períodos de paragem); desvio dos resíduos rapidamente biodegradáveis para valorização; a existência de uma percentagem superior ao normal de oxigénio no biogás; a utilização de escórias e cinzas, e a correspondente redução da humidade devido ao compactamento exercido sobre os resíduos durante a sua deposição. Visto tratar-se de um estudo de viabilidade económica da valorização do biogás, foram propostos três cenários para a valorização do biogás. O 1º cenário contempla a instalação de um sistema gerador de energia para comercialização junto da Rede Eléctrica Nacional. O 2º Cenário contempla a instalação de um sistema alternativo de alimentação à caldeira da central de valorização energética de forma a substituir o combustível utilizado actualmente. E o 3º Cenário vem de encontro com os resultados observados actualmente onde se verifica uma reduzida produção/recolha de biogás no aterro. Assim é proposto um sistema gerador de energia que garanta o auto-consumo da exploração do aterro (26 MWh/ano). Qualquer um dos cenários apresenta uma VAL negativa o que leva a concluir que não são viáveis. No entanto, através da análise de sensibilidade, verificamos que estes são claramente afectados por factores como o benefício e o investimento anual, concluindo-se que com alterações nos factores de cálculo, como por exemplo, um aumento no consumo de combustível auxiliar da caldeira (2º cenário), ou com um aumento da factura eléctrica (3º cenário), ou com o aumento do tempo de retorno do investimento inicial(1º cenário), os projectos podem-se tornar viáveis. Por fim importa referir que independentemente da valorização é fundamental continuar a eliminar a máxima quantidade de metano produzida para tentar diminuir o impacto que este tem sobre o ambiente.
Resumo:
A rede de transporte ferroviária é um meio de transporte seguro, rápido e bastante utilizado pela população. Este facto fez com que os sistemas elétricos de tração tivessem uma grande evolução ao longo dos últimos anos nomeadamente, ao nível da alta velocidade. Por essa razão, é pertinente uma análise cuidada do impacto destes sistemas na rede de transporte. Neste trabalho é efetuado um pequeno resumo sobre os sistemas elétricos de tração desde as subestações até à alimentação das locomotivas. Aborda-se também a rede de transporte que se encontra a montante do sistema de tração que sofre perturbações provocadas pelos sistemas de tração. Por último realizou-se uma análise do impacto do sistema de tração na rede de transporte recorrendo à simulação no MATLABTM/Simulink. Analisou-se um conjunto de grandezas elétricas para diversos cenários, considerando a alimentação da catenária a 1x25 kV e 2x25 kV.
Resumo:
This thesis presents the Fuzzy Monte Carlo Model for Transmission Power Systems Reliability based studies (FMC-TRel) methodology, which is based on statistical failure and repair data of the transmission power system components and uses fuzzyprobabilistic modeling for system component outage parameters. Using statistical records allows developing the fuzzy membership functions of system component outage parameters. The proposed hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models allows catching both randomness and fuzziness of component outage parameters. A network contingency analysis to identify any overloading or voltage violation in the network is performed once obtained the system states. This is followed by a remedial action algorithm, based on Optimal Power Flow, to reschedule generations and alleviate constraint violations and, at the same time, to avoid any load curtailment, if possible, or, otherwise, to minimize the total load curtailment, for the states identified by the contingency analysis. For the system states that cause load curtailment, an optimization approach is applied to reduce the probability of occurrence of these states while minimizing the costs to achieve that reduction. This methodology is of most importance for supporting the transmission system operator decision making, namely in the identification of critical components and in the planning of future investments in the transmission power system. A case study based on Reliability Test System (RTS) 1996 IEEE 24 Bus is presented to illustrate with detail the application of the proposed methodology.
Resumo:
In this paper, we characterize two power indices introduced in [1] using two different modifications of the monotonicity property first stated by [2]. The sets of properties are easily comparable among them and with previous characterizations of other power indices.
Resumo:
Catastrophic events, such as wars and terrorist attacks, tornadoes and hurricanes, earthquakes, tsunamis, floods and landslides, are always accompanied by a large number of casualties. The size distribution of these casualties has separately been shown to follow approximate power law (PL) distributions. In this paper, we analyze the statistical distributions of the number of victims of catastrophic phenomena, in particular, terrorism, and find double PL behavior. This means that the data sets are better approximated by two PLs instead of a single one. We plot the PL parameters, corresponding to several events, and observe an interesting pattern in the charts, where the lines that connect each pair of points defining the double PLs are almost parallel to each other. A complementary data analysis is performed by means of the computation of the entropy. The results reveal relationships hidden in the data that may trigger a future comprehensive explanation of this type of phenomena.
Resumo:
This paper presents a complete, quadratic programming formulation of the standard thermal unit commitment problem in power generation planning, together with a novel iterative optimisation algorithm for its solution. The algorithm, based on a mixed-integer formulation of the problem, considers piecewise linear approximations of the quadratic fuel cost function that are dynamically updated in an iterative way, converging to the optimum; this avoids the requirement of resorting to quadratic programming, making the solution process much quicker. From extensive computational tests on a broad set of benchmark instances of this problem, the algorithm was found to be flexible and capable of easily incorporating different problem constraints. Indeed, it is able to tackle ramp constraints, which although very important in practice were rarely considered in previous publications. Most importantly, optimal solutions were obtained for several well-known benchmark instances, including instances of practical relevance, that are not yet known to have been solved to optimality. Computational experiments and their results showed that the method proposed is both simple and extremely effective.
Resumo:
Este trabalho é baseado no simulador de redes PST2200 do Laboratório de Sistemas de Energia (LSE) pois está avariado com vários problemas conhecidos, designadamente: - Defeito de isolamento (disparo de diferencial), - Desregulação da velocidade da máquina primária (motor DC), - Circuito de excitação da máquina síncrona inoperacional, - Inexistência de esquemas elétricos dos circuitos do simulador, - Medidas desreguladas e com canais de medida com circuito impresso queimado. O trabalho executado foi: - O levantamento e desenho de raiz (não existe qualquer manual) dos esquemas dos 10 módulos do simulador, designadamente naqueles com avaria ou com desempenho problemático a fim de que se possa ter uma visão mais pormenorizada dos circuitos e seus problemas, por forma a intervir para os minimizar e resolver, - Foi realizado o diagnóstico de avaria do simulador e foram propostas soluções para os mesmos, - Realizaram-se as intervenções propostas e aprovadas. Nas intervenções realizadas, os princípios orientadores foram: - Aumentar a robustez do equipamento por forma a garantir a sua integridade a utilizações menos apropriados e manobras 'exóticas' próprias de alunos, que pela sua condição, estão em fase de aprendizagem, - Atualizar o equipamento, colocando-o em sintonia com o 'estado da arte', - Como fator de valorização suplementar, foi concebida e aplicada a supervisão remota do funcionamento do simulador através da rede informática. Foram detetados inúmeros erros: - Má ligação do motor de corrente continua ao variador, resultando a falta de controlo da frequência da rede do sistema, - Ligações entre painéis trocadas resultando em avarias diversas das fontes de alimentação, - Cartas eletrónicas de medidas avariadas e que além de se reparar, foram também calibradas. Devido ao mecenato da empresa Schnitt + Sohn participando monetariamente, fez-se o projeto de alteração e respetiva execução de grande parte do simulador aumentando a fiabilidade do mesmo, diminuindo assim a frequência das avarias naturais mais as que acontecem involuntariamente devido a este ser um instrumento didático. Além do trabalho elétrico, foi feito muito trabalho de chaparia para alteração de estrutura e suporte do material com diferenças de posicionamento. Neste trabalho dá-se também alguns exemplos de cálculo e simulação das redes de transporte que se pode efetuar no simulador como estudo e simulação de avarias num sistema produtivo real. Realizou-se a monitorização de dois aparelhos indicadores de parâmetros de energia (Janitza UMG96S) através duma rede com dois protocolos ethernet e profibus utilizando o plc (Omron CJ2M) como valorização do trabalho.
Resumo:
Competitive electricity markets have arisen as a result of power-sector restructuration and power-system deregulation. The players participating in competitive electricity markets must define strategies and make decisions using all the available information and business opportunities.
Resumo:
Although power-line communication (PLC) is not a new technology, its use to support communication with timing requirements is still the focus of ongoing research. Recently, a new infrastructure was presented, intended for communication using power lines from a central location to geographically dispersed nodes using inexpensive devices. This new infrastructure uses a two-level hierarchical power-line system, together with an IP-based network. Within this infrastructure, in order to provide end-toend communication through the two levels of the powerline system, it is necessary to fully understand the behaviour of the underlying network layers. The masterslave behaviour of the PLC MAC, together with the inherent dynamic topology of power-line networks are important issues that must be fully characterised. Therefore, in this paper we present a simulation model which is being used to study and characterise the behaviour of power-line communication.
Resumo:
This paper describes the communication stack of the REMPLI system: a structure using power-lines and IPbased networks for communication, for data acquisition and control of energy distribution and consumption. It is furthermore prepared to use alternative communication media like GSM or analog modem connections. The REMPLI system provides communication service for existing applications, namely automated meter reading, energy billing and domotic applications. The communication stack, consisting of physical, network, transport, and application layer is described as well as the communication services provided by the system. We show how the peculiarities of the power-line communication influence the design of the communication stack, by introducing requirements to efficiently use the limited bandwidth, optimize traffic and implement fair use of the communication medium for the extensive communication partners.
Resumo:
Mal sabia o Italiano Antonio Santi Giuseppe Meucci na segunda metade do século XIX (1870-1876), que a sua invenção iria alcançar um êxito sem precedente e que mudaria por completo o estilo de vida das gerações vindouras: o “Telettrofono” (telégrafo falante). Porém, e por necessidade, acabou por vender o protótipo e seus respetivos direitos, a Alexander Graham Bell, o qual ficou historicamente conhecido como o inventor do telefone. Com efeito, o telefone quase que dispensa apresentação. É um dispositivo de telecomunicações que entrou paulatinamente nas vidas das pessoas, seja no lazer, no exercícios das suas profissões, em situações de emergência, em teatro de guerra, num infindável número de situações, e que foi simplesmente planeado para transmitir sons por meio de sinais elétricos em condutores próprios para o efeito (vias telefónicas). Por definição, é um aparelho eletroacústico que permite a transformação, no ponto emissor, de energia acústica em energia elétrica e, no ponto recetor, a transformação da energia elétrica em acústica, permitindo assim a troca de informações (falada e ouvida) entre dois ou mais assinantes. Ora, a ideia de Power over Ethernet (PoE) teve, forçosamente, seu marco nos finais do século XIX, quando Alexander Bell (“Bell Telephone Company”) teve de refletir/decidir se o telefone a instalar em cada residência, seria alimentado localmente por uma bateria (fonte de energia local), ou se deveria alimentar cada dispositivo telefónico remotamente através de fios condutores. Esta é a noção de Power over Ethernet na sua vanguarda de aplicação no início do século XXI, e objeto de uma breve apresentação, à qual o convido à leitura das restantes secções.
Resumo:
A large part of power dissipation in a system is generated by I/O devices. Increasingly these devices provide power saving mechanisms to inter alia enhance battery life. While I/O device scheduling has been studied in the past for realtime systems, the use of energy resources by these scheduling algorithms may be improved. These approaches are crafted considering a huge overhead of device transition. The technology enhancement has allowed the hardware vendors to reduce the device transition overhead and energy consumption. We propose an intra-task device scheduling algorithm for real time systems that allows to shut-down devices while ensuring the system schedulability. Our results show an energy gain of up to 90% in the best case when compared to the state-of-the-art.